• 제목/요약/키워드: Anti-icing performance test

검색결과 9건 처리시간 0.023초

내빙선박용 풍우밀 문의 결빙방지 기법 연구 (A Study on Anti-Icing Technique for Weather-Tight Door of Ice-Strengthened Vessels)

  • 정성엽;천은지;조성락;이춘주
    • 대한조선학회논문집
    • /
    • 제48권6호
    • /
    • pp.575-580
    • /
    • 2011
  • Icing problem of ice-strengthened vessels is an important issue when operating in low temperature environment and it can cause damage to deck machineries and emergency equipments. Many ice-strengthened vessels have since been constructed and operated in accordance with the ice class rules such as Det Norske Veritas (DNV), Russian Maritime Register of Shipping (RS), American Bureau of Shipping (ABS) and so on. Therefore winterization is defined as the preparation of a ship for safe operation. In this research, anti-icing performance tests of weather-tight door have been carried out at various temperature conditions($5^{\circ}C$, $-10^{\circ}C$, $-20^{\circ}C$, $-30^{\circ}C$, $-40^{\circ}C$) in the low temperature cold room facility and then, ambient temperature, specimen temperature, electric current and temperature of heating cable were measured during the test operations. This research describes the construction guidelines of weather-tight door based on anti-icing test results to apply to the full-scale vessels.

극지운항용 빙해선박의 밸러스트 수 결빙방지 기법 연구 (A Study on Anti-Icing Technique for Ballast Water of Icebreaking Vessels Operating in Ice-Covered Water)

  • 정성엽;이춘주;조성락
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.93-97
    • /
    • 2011
  • When freezing is present on ballast water, it can impose additional loads on the hull and effect on stabilization of ship. The anti-icing techniques of ballast water, therefore, are key criteria for ship safety. The existing anti-icing techniques of ballast tank are hull heating, water circulation and air bubble system etc. In this research, anti-icing performance tests for the ballast water using micro-bubble system and sea water circulation system have been carried out at two temperature conditions($-10^{\circ}C$ and $-25^{\circ}C$). Ambient temperature, sea water temperature and temperature of the inner parts of the ballast tank are measured and also ballast water conditions are checked during the model test. The applied anti-icing techniques of ballast water, such as micro-bubble system and sea water circulation system show good performance in the low temperature conditions.

얼음두께를 이용한 결빙시험조건의 간접 확인기법 (Indirect Verification of the Icing Test Condition Using Ice Thickness)

  • 김유경;박남은;최기오
    • 한국항공우주학회지
    • /
    • 제46권11호
    • /
    • pp.944-951
    • /
    • 2018
  • 회전익기의 결빙운용능력이 요구될 경우 자연결빙 비행시험전 풍동시험과 인공결빙시험을 선행하면 개발기간을 단축시킬수 있다. 한국형기동헬기의 경우 인공결빙 시험을 수행하여 각 시험조건에서 방 제빙기능의 정상작동을 확인 후 자연결빙시험을 수행하였다. 인공결빙시험에서 시험조건인 액적량(LWC)과 액적 평균직경(MVD)을 확인하기 위해 정밀센서인 구름기상정보관측기(CCP)를 사용하는데 시험환경, 장비오차등의 이유로 측정치의 불확실성이 존재할 수 있어 시험조건 확인이 다방면으로 필요하다. 동체에 착빙된 얼음두께로부터 LWC를 계산하여 측정값과 비교한 결과, 시험조건을 간접적으로 검증해 볼 수 있는 효과적인 방법임을 확인하였다.

회전익기 공기흡입구 주위 방빙장치 성능 해석 (Investigation of the Performance of Anti-Icing System of a Rotorcraft Engine Air Intake)

  • 안국빈;정기영;정성기;신훈범;명노신
    • 한국항공우주학회지
    • /
    • 제41권4호
    • /
    • pp.253-260
    • /
    • 2013
  • 회전익기의 공기흡입구 주위 표면에 발생한 결빙은 엔진의 성능을 저해하는 요인으로 비행 안전성에 심각한 영향을 끼칠 수 있다. 항공기 표면에 발생하는 결빙현상을 분석하는데 많은 비용이 소요되는 결빙 풍동 시험 및 비행시험에 비해 전산유체역학을 기반으로 한 결빙 시뮬레이션은 매우 효과적인 도구가 될 수 있다. 본 연구에서는 결빙조건에서 회전익기 공기흡입구 부근에 설치된 방빙장치의 작동 유무에 따른 결빙의 양과 발생 영역을 CFD 예측기법 및 결빙 풍동시험을 통해 분석하였다. 방빙장치를 작동시킨 경우 공기 흡입구 표면에서의 결빙의 질량과 최대 두께가 약 80% 이상 감소하는 것을 확인하였다.

액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법 (Icing Characteristics in Liquid-Phase Injection of LPG Fuel)

  • 이선엽;김창업;최교남;강건용
    • 한국분무공학회지
    • /
    • 제14권4호
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

빙해선박 상부갑판 열선의 열전달 특성에 따른 착빙방지 성능평가 및 설계기준에 관한연구 (A Study on the Anti-Icing Performance Evaluating and Design Guide by Heating Coil for Upper Deck of Icebreaking Vessels)

  • 이종찬;서영교;이춘주
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.541-549
    • /
    • 2012
  • The study adopted a freezing prevention method of the upper deck which used heating coil, and carried out numerical analysis by using ANSYS 13.0 CFD for design guide of the vessel operating in cold region. It is based on the experimental results of the anti-icing performance tests which were carried at cold room chamber in MOERI. Numerical analysis for the design guide was performed by considering S.S.T. (Shear Stress Transport) turbulent model for flow separation effects and the turbulence which occurred in interfaces of the numerical model in order to express appropriate heat transmission phenomenon. The numerical result shows average temperature of the upper deck surface appeared similarly compared with the indoor chamber test. The design guide for optimum freezing prevention presented through heat transmission capability and interval of the heat coil in various outdoor temperature($10^{\circ}C{\sim}-30^{\circ}C$) and wind speed(1m/s~7m/s).

LPG 액상분사식 인젝터에서 후적에 의한 아이싱 특성 연구 (Characteristics of Icing Phenomenon with Droplet of an Injector for Liquid Phase LPG Injection System)

  • 박철웅;김창업;최교남;강건용
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.9-16
    • /
    • 2007
  • Since the liquid phase LPG injection(LPLI) system has an advantage of higher power and lower emission characteristics than the mixer type fuel supply system, many studies and applications have been conducted. However, the heat extraction, due to the evaporation of liquid fuel, causes not only a dropping of LPG fuel but also icing phenomenon that is a frost of moisture in the air around the nozzle tip. Because both lead to a difficulty in the control of accurate air fuel ratio, it can result in poor engine performance and a large amount of HC emissions. The experimental investigation was carried out on the bench test rig in this study. It was found that n-butane, that has a relatively high boiling point($-0.5^{\circ}C$), was a main species of droplet composition and also found that the droplet problem was improved by the use of a large inner to outer bore ratio nozzle whose surface roughness is smooth. The icing phenomena were decreased when the an engine head temperature was increased, although a large amount of icing deposit was still observed in the case of $87^{\circ}C$. Also, it was observed that the icing phenomenon is improved by using anti-icing bushing.

국내 제설제 랩기반 성능평가 방법과 현장 시험방법 제안 (Proposal of Laboratory Test and Field Test for performance Qualification of Anti-icing Materials)

  • 장필성;최윤석;박찬
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2017년 정기학술대회
    • /
    • pp.127-128
    • /
    • 2017
  • 최근에는 발생되고 있는 염화물계 제설제의 도로 손상, 차량 부식 및 미끄럼으로 인한 교통사고 문제를 해결하기 위해 친환경 제설제의 사용이 권장되고 있다. 그러나, 현재 수행되고 있는 친환경 제설제의 성능 시험 방법은 실내에서 얼음을 이용하여 실시되고 있으나, 실제 현장 성능과의 상관 관계가 낮은 것으로 나타났다. 따라서 본 논문에서는 현재 수행되고 있는 제설제 성능평가 방법을 소개하고 국내 실정에 부합하는 제설제의 성능 검증을 위한 현장 시험 방법을 제안하고자 한다.

  • PDF

보도용 연성 샌드 아스팔트 포장의 충격흡수 특성 평가 (Evaluation of Impact Energy Absorption Characteristics of Flexible Sand Asphalt Pavement for Pedestrian Way)

  • 최창정;동배선;김광우;김성운
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.31-41
    • /
    • 2019
  • More than 90% of roadway in the world are paved as asphalt concrete pavement due to its excellent properties compared with other paving materials; excellent riding quality, flexibility, anti-icing property and easy maintenance-ability. In this study, to make best use of the softer property of the asphalt mixture, the flexible sand asphalt mixture (FSAM) was developed for pedestrian ways. The mix design was conducted to prepare FSAM using PG64-22 asphalt, screenings (sand) less than 5mm, crumb rubber, hydrated lime and limestone powder without coarse aggregate. The deformation strength ($S_D$), indirect tensile strength (ITS) and tensile strength ratio (TSR) tests were conducted to make sure durability of FSAM performance. The impact energy absorption and flexibility were measured by drop-boll test and the resilient modulus ($M_R$) test. The impact energy absorption of FSAM was compared with normal asphalt pavement, concrete pavement, stone and concrete block for pedestrian way. As a result of drop-boll test, FSAM showed higher impact energy absorption compared with other paving materials with the range of 18% to 43%. Impact energy absorption of FSAM increased with increasing test temperature from 5 to $40^{\circ}C$. The results of $M_R$ test at $5^{\circ}C$ showed that the flexibility of FSPA was increased further, because the $M_R$ value of the sand asphalt was measured to be 38% lower than normal dense-graded asphalt mixture (WC-1). Therefore, it was concluded that the FSAM could provide a high impact absorbing characteristics, which would improve walking quality of the pedestrian ways.