• Title/Summary/Keyword: Anteroposterior diameter

Search Result 36, Processing Time 0.025 seconds

The Relationship between Thymic Size and Vesicoureteral Reflux in Infants with Febrile Urinary Tract Infection (발열성 요로감염 영아에서 방광요관역류와 연관된 흉선의 크기)

  • Jung, Seong-Kwan;Park, Kyu-Hee;Yim, Hyung-Eun;Yoo, Kee-Hwan;Hong, Young-Sook;Lee, Joo-Won
    • Childhood Kidney Diseases
    • /
    • v.13 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • Purpose : Thymus is a lymphoproliferative organ that changes size in various physiological states in addition to some pathological conditions. Thymus is susceptible to involution, and shows a dramatic response to severe stress. Thymic measurements may be helpful in various diseases. UTI (urinary tract infection) is most common bacterial infection in infants and VUR (vesicoureteral reflux) is a common abnormality associated with UTI. In our study, the size of thymus was compared on the premise that a greater stress is exerted on the body when UTI is accompanied by VUR, than when occurs on its own. Methods : Thymic size was measured on standard chest anteroposterior radiographs and expressed as the ratio between the transverse diameter of the cardiothymic image at the level of the carina and that of the thorax (CT/T). The medical records of 99 febrile urinary tract infection infants without other genitourinary anomalies except VUR were reviewed retrospectively. Results : Among 99 patients with febrile UTIs, 25 were febrile UTI without VUR and 74 with VUR. For the UTI with VUR group, there was a significant decrease in the thymic size compared to the those without VUR group ($0.382{\pm}0.048$ vs $0.439{\pm}0.079$, P<0.05). However, there were no differences in the duration of fever and WBC, CRP between the UTI with VUR and UTI without VUR. In addition, there were no differences in the cardiothymic/thoracic ratios between renal defects and renal scars in febrile UTI patients. Conclusion : The results of this study show that the shirinkage of thymus was more frequently found in the UTI patients with VUR. Therefore, awareness of the risks associated with thymic size is important for the appropriate work up and management of UTI patients.

The relationship between condyle position, morphology and chin deviation in skeletal Class III patients with facial asymmetry using cone-beam CT (안면비대칭을 동반한 골격성 III급 부정교합자에서 하악 과두의, 위치 형태와 이부 편위의 관계: cone-beam CT를 이용한 연구)

  • Lee, Bo-Ram;Kang, Dae-Keun;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il;Lee, Kyung-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.87-97
    • /
    • 2011
  • Objective: Facial asymmetry is usually evaluated from the difference in length and angulation of the maxilla and mandible. However, asymmetric position or shape of the condyle can also affect the expression of asymmetry. The purpose of this study was to evaluate the correlation between condylar asymmetry and chin point deviation in facial asymmetry. Methods: Cone-beam CT images of fifty adult skeletal Class III patients were studied. Thirty patients who had more than 4 mm menton deviation were categorized in the asymmetric group. Twenty patients with less than 4 mm menton deviation were assigned to the symmetric group. Anteroposterior and transverse condyle positions were evaluated from the cranial base. The greatest mediolateral diameter (GMD) of the condyle in the axial plane and angulation to the coronal plane were measured. The height and volume of the condyles were evaluated. Results: The symmetric group had no statistical difference between both condyles in position, angulation, GMD, height and volume. In the asymmetric group, the non-deviated side condyle was larger in GMD, height and volume than the deviated side. There was no statistical difference in condyle position and angulation. The GMD, height difference and condylar volume ratio (non-deviated/deviated) were positively correlated with chin deviation. From the linear regression analysis, condylar volume ratio was a significant factor affecting chin deviation. Conclusions: These findings suggests that the non-deviated side condyle is larger than the deviated side. In addition, condylar asymmetry can affect the expression of facial asymmetry.

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF

The significance of corpus callosal size in the estimation of neurologically abnormal infants (신경학적인 결함이 있었던 영아의 예후 판단에서 뇌량 크기의 중요성)

  • Yu, Seung Taek;Lee, Chang Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1205-1210
    • /
    • 2008
  • Purpose : The development of the corpus callosum occupies the entire period of cerebral formation. The myelination pattern on magnetic resonance imaging (MRI) is very useful to evaluate neurologic development and to predict neurologic outcome in high risk infants. The thickness of the corpus callosum is believed to depend on the myelination process. It is possible to calculate the length and thickness of the corpus callosum on MRI. Thus, we can quantitatively evaluate the development of the corpus callosum. We investigated the clinical significance of measuring various portions of the corpus callosum in neonate with neurologic disorders such as hypoxic brain damage and seizure disorder. Methods : Forty-two neonates were evaluated by brain MRI. We measured the size of the genu, body, transitional zone, splenium, and length of the corpus callosum. Each measurement was divided by the total length of the corpus callosum to obtain its corrected size. The ratio of corpus callosal length and the anteroposterior diameter of the brain was also measured. Results : There was no statistical significance in the sample size of each part of the corpus callosum. However, the corrected size or the ratio of body of the corpus callosum correlated with periventricular leukomalacia and hypoxic ischemic encephalopathy. Conclusion : The abnormal size of the corpus callosum showed a good correlation with periventricular leukomalacia and hypoxic ischemic encephalopathy in neonates. We can predict clinical neurological problems by estimation of the corpus callosum in the neonatal period.

The Measurement of Normal Talus in Korean Cadaver (한국인 사체에서의 정상 거골의 실측)

  • Ha, Dong-Jun;Gwak, Heui-Chul;Kim, Jeon-Gyo;Kim, Jung-Han;Lee, Chang-Rak;Kim, Young-Jun;Lee, Jeong-Han;Ha, Byung-Ho;Kim, Ui-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.163-169
    • /
    • 2016
  • Purpose: To investigate the measured values of the talus in Koreans. Materials and Methods: We measured 88 tali from 44 cadavers that have been donated between December 2012 and December 2015. Of the cadavers, 27 were male and 17 were female. Their mean age was 73 years. The length and width of the talus were measured using a digital goniometer and vernier caliper. Results: The values of cadaveric measurement, mean maximal width and length, width and length of the dome anterior, width and length of the posterior facet, height and length of the trochlear medial facet, and height and length of the trochlear lateral facet were $43.6{\pm}2.6mm$, $56.5{\pm}3.3mm$, $32.5{\pm}2.0mm$, $42.2{\pm}2.7mm$, $22.2{\pm}2.2mm$, $34.7{\pm}2.0mm$, $15.3{\pm}1.3mm$, $33.3{\pm}2.9mm$, $25.3{\pm}3.3mm$, and $30.8{\pm}2.4mm$ for men and $38.9{\pm}1.6mm$, $53.6{\pm}2.4mm$, $27.9{\pm}2.1mm$, $37.4{\pm}3.2mm$, $20.6{\pm}0.8mm$, $31.9{\pm}1.2mm$, $13.6{\pm}2.6mm$, $28.4{\pm}2.5mm$, $24.9{\pm}2.1mm$, and $28.9{\pm}1.4mm$ for women, respectively. The size of the talus showed an accuracy of 86% when anteroposterior diameter was greater than 59 mm. A difference in the size of the right and left talus was not observed. The mean inclination and declination angles were $24.4^{\circ}{\pm}4.2^{\circ}$ and $28.2^{\circ}{\pm}5.4^{\circ}$ for men, and $24.6^{\circ}{\pm}3.6^{\circ}$ and $24.7^{\circ}{\pm}6.7^{\circ}$ for women (p=0.980, p=0.018), respectively, at least $15^{\circ}$, which showed a big difference for every object up to $37^{\circ}$. Conclusion: This paper, to the best of our knowledge, is the first study to measure the talus in Koreans. There were differences by gender and ethnicity in the in measured talus values. The measurements were smaller than European-Americans and greater than Japanese.

Effect of location of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture (광중합형 레진에 함침시킨 유리섬유의 위치가 상악 총의치의 파절강도와 파절양상에 미치는 영향)

  • Yoo, Hyun-Sang;Sung, Su-Jin;Jo, Jae-Young;Lee, Do-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: This study evaluated the effect of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture. Materials and methods: Maxillary acrylic resin complete dentures reinforced with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheongun, Korea) and without reinforcement were tested. The reinforcing material was embedded in the denture base resin and placed different regions (Control, without reinforcement; Group A, center of anterior ridge; Group B, rugae area; Group C, center of palate; Group D, full coverage of denture base). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The data were analyzed with one-way ANOVA at the significance level of 0.05. Results: There were non-significant differences (P>.05) in the fracture strength among test groups. Group A showed anteroposterior fracture and posterior fracture mainly, group B, C and control group showed partial fracture on center area mostly. Most specimen of group D showed posterior fracture. Conclusion: The location and presence of the fiber reinforcement did not affect the fracture strength of maxillary complete denture. However, reinforcing acrylic resin denture with glass fiber has a tendency to suppress the crack.