• 제목/요약/키워드: Anterior teeth retraction

검색결과 52건 처리시간 0.025초

Laser 반사측정법을 이용한 상악전치부의 후방견인시 저항중심의 수직적 위치에 관한 실험적 연구 (EXPERIMENTAL STUDY OF THE VERTICAL LOCATION OF THE CENTERS OF RESISTANCE FOR MAXILLARY ANTERIOR TEETH DURING RETRACTION USING THE LASER REFLECTION TECHNIQUE)

  • 우재영;박영철
    • 대한치과교정학회지
    • /
    • 제23권3호
    • /
    • pp.375-389
    • /
    • 1993
  • The delivery of optimal orthodontic treatment is greatly influenced by a clinician's ability to predict and control tooth movement achieved by applying known force systems to the dentition. It is important to determine the location of the center of resistance of a tooth or group of teeth to better understand the nature of their displacement characteristics under the various force levels. The purpose of this study was to define the location of the centers of resistance of various units of the upper anterior segment for lingually directed 100gm and 200gm force in a dry human skull. The units investigated were composed of four incisors and six anterior teeth. In addition, the effect of change in force magnitude on the location of the center of resistance of these units was investigated. The laser reflection technique was used to measure the initial displacements of the consolidated teeth under loading. The results were as follows: 1. The instantaneous center of resistance for the four anterior teeth was located vertically between level 4 and level 5-that is, at $37.4\%$ apical to the cementoenamel junction level. 2. The instantaneous center of resistance for the six anterior teeth was located vertically just beneath level 5-that is, at $50.3\%$ apical to the cementoenamel junction level. 3. Increasing force levels had little effect on the location of the center of resistance of a given unit. 4. The location of the instantaneous center of resistance shifted apically as the number of dental units consolidated increased.

  • PDF

Bioprogressive Therapy에 의한 Angle II급 1류 부정교합의 교정치험예 (Case Reports of Angle's Class II, Division 1 malocclusions treated by Bioprogressive Therapy)

  • 정규림
    • 대한치과교정학회지
    • /
    • 제13권2호
    • /
    • pp.209-222
    • /
    • 1983
  • Three patients who had Angle's Class II Division 1 malocclusion were treated by Bioprogressive therapy. In spite of their occlusions, the 3 patients did not have any skeletal problems. Their skeletal patterns were within normal range. So headgear or functional appliance therapy were not considered. During the treatment procedure, the most noteworthy results of Bioprogressive therapy were the effect of the Utility arch to intrude 4 mandibular anterior teeth, the effect of the Cuspid retractor in cuspid retraction and the effect of the Double delta retraction arch in the retraction of 4 anterior teeth. The whole treatment results in these cases which were achieved by Bioprogressive therapy were very favorable and the efficiency of this therapy was very excellent.

  • PDF

구개측 미니플래이트를 이용한 양악 치아치조성 전돌환자에서의 설측 Biocreative therapy 적용 (Severe bidentoalveolar protrusion treated with lingual Biocreative therapy using palatal miniplate)

  • 정규림;정도민;박현정;김성훈
    • 대한치과교정학회지
    • /
    • 제40권4호
    • /
    • pp.276-287
    • /
    • 2010
  • 본 증례보고는 심한 양악 치아치조성 전돌과 전치부 치열밀집을 보이는 23세 8개월 여자 환자를 대상으로 한 변형된 형태의 설측 교정치료법인 설측 Biocreative therapy 치료를 소개하고자 한다. 양악 제1소구치 발치 후 구개천장에 식립된 C-플래이트에 lingual sheath가 달린 보조장치를 접착하여 상악구치부에 장치부착 없이 튜브역할을 대신하게 하였으며 상악 전치부의 decrowding과 견인을 위하여 설측 교정용 브라켓을 사용하지 않고 0.022 슬롯을 가진 순측 브라켓을 치아 설면에 부착한 후 납착된 설측 레버암을 이용하여 상악 전치부의 3차원적인 견인을 시행하였으며, 견인 후 finishing 기간동안 tooth positioner를 사용하였다. 상악 구치부의 장치부착 없이도 총 치료기간은 19개월 소요되었고, 안정적인 교합관계와 안모의 개선이 이루어졌다. 장치 제거 후 13개월 유지 후에도 양호한 결과가 유지되었다.

상악 전치부 견인 시 치아이동에 따른 전방 치조골개조량의 변화에 관한 연구 (THE LIMITATION OF ALVEOLAR BONE REMODELING DURING RETRACTION OF THE UPPER ANTERIOR TEETH)

  • 황충주;문정련
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.97-105
    • /
    • 2001
  • 교정 치료 시 많은 경우 상악 전치부를 상당량 견인하게 되며 이 때 치아의 이동량과 전방 피질골의 개조량이 동일하게 일어나지 않는다면 치주적인 문제가 발생할 수 있게 된다. 이에 본 연구에서는 상악 전치가 후방 견인될 때 치아의 이동량과 피질골의 개조량의 관계를 알아보기 위하여 성장이 완료된 만 18세 이상의 성인 여자환자 56명을 대상으로 치료 전후의 측모두부 방사선 사진을 계측하였다. 연구대상 56명은 전치의 후방견인 시 경사이동이 주로 일어난 환자(26명 )와 치체 이동이 동반된 환자(30명)로 나누었으며 치료 전후의 측모두부방사선 사진을 true horizontal plane 을 기준으로 하여 중첩하였다. Tip-Group(경사이동된 군)에서는 수평적인 bone remodeling/tooth movement ratio가 1:1.63, Torque-Group(치체 이동이 동반된 군)에서는 1:1.66이었다. 두 군 모두에서 치아의 이동량과 골의 개조량이 동일하지 않았기 때문에 경사 이동 시에는 치근첨이 구개측피질골판에서 멀어지고 순측피질골판에 가까워지며, 치체이동이 동반된 군에서는 치근이 순측피질골판에서는 멀어지고 구개측피질골판에 접근하게 된다. 따라서 상악의 전방 피질골의 두께가 매우 얇은 환자에서는 상악 전치의 후방견인량에 제한이 있게 되며 골격적 부조화가 심한 경우에는 악교정수술을 동반한 치료를 고려하고, 교정적 절충치료가 필요한 경우 술자는 그 치료한계를 명확히 인식해야할 것이다.

  • PDF

골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석 (Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage)

  • 김찬년;성재현;경희문
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.339-350
    • /
    • 2003
  • 본 연구에서는 활주법을 이용한 전치부 후방 견인시 micro-implant의 다양한 수직적 위치와 전치부에서 힘의 적용점에 따른 치아 이동 양상을 관찰하여 공간 폐쇄시 전치부의 설측 경사와 정출력을 방지할 수 있는 micro-implant의 위치와 전치부 힘의 적용점의 위치를 알아보고자 하였다. 유한 요소 모델을 이용하여 제1소구치가 발거된 상악 치열궁 형태를 제작하고 $.022"{\times}.028"$ 슬롯 브라켓을 모형화하여 치아에 부착시켰다. $.019"{\times}.025"$ stainless steel 선재를 3차원 beam모형으로 제작하고 상악 측절치와 견치 브라켓 사이의 선재 상에 $.032"{\times}.032"$ 크기의 stainless steel hook을 수직으로 8mm의 높이로 형성하였으며, 선재로부터 2mm높이에서 1mm간격으로 8mm까지 힘 적용점을 설정하였다. 지름 1.2mm,길이 6mm의 micro-implant를 제2소구치와 제1대구치 사이의 치조골에 선재로부터 4mm에서 10mm까지 2mm간격으로 4개를 위치시켰다 각각의 micro-implant와 전치부 hook에 150gm의 힘을 적용시켜 다양한 힘 적용점에 따른 치아의 초기 변위를 분석하여 다음의 결과를 얻을 수 있었다. 1. Micro-implant 높이가 4m일 경우 5mm이하의 전치부 hook 높이에서는 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6m이상 되었을 때 전치부 순측 경사 이동이 일어났다. 2. Micro-implant높이가 6mm일 경우 5mm이하의 전치부 hook높이에서 전치부 설측 경사 이동이 일어났으며 전치부 hook 높이가 6mm 이상 되었을 때 전치부 순측 경사 이동이 일어났다 이것은 4mm micro-implant에서의 실험결과와 유사한 이동 양상을 나타내었지만, micro-implant높이가 6mm일 때 전치부 설측 경사 이동이 좀더 감소하였다. 3. Micro-implant높이가 8m일 경우 전치부 hook높이가 2mm일 때 전치의 설측 경사 이동이 일어났으며 3mm이상의 전치부 hook 높이에서 순측 경사 이동이 비례적으로 증가하였다. 4. Micro-implant높이가 10mm일 경우 전치부 hook 높이가 2mm 이상에서 전치의 순측 경사 이동이 비례적ㅇ로 증가하였다. 5. 전치부 hook 높이가 증가할수록 전치의 순측 경사 이동이 증가되지만 선재의 뒤틀림에 의한 변형이 증가되므로 견치와 소구치 부위에서 정출력이 발생하는 바람직하지 못한 치아 이동 양상이 일어났다. 6. Micro-implant를 이용한 상악 5전치 후방 견인시 구치부의 이동은 선재와 브라켓 사이의 마찰력에 의해서 원심경사 이동이 발생하였다.

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제50권1호
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

상악 중절치 후방 이동시의 이동양상에 관한 유한요소법적 연구 (A STUDY ON THE PATTERN OF MOVEMENT DURING RETRACTION OF MAXILLARY CENTRAL INCISOR BY FINITE ELEMENT METHOD)

  • 장재완;손병화
    • 대한치과교정학회지
    • /
    • 제21권3호
    • /
    • pp.617-634
    • /
    • 1991
  • The retraction of anterior teeth is one of the fundamental methods in orthodontic treatment and a proper position and angulation of anterior teeth after the retraction are very important for esthetics, stability, and function of teeth. In this research we analyzed, by Finite Element Method, the stress distribution on the periodontal ligament according to the variation of force and moment applied on the crown and predict the pattern of movement of maxillary central incisor. At the same time, the amount of force and moment caused by activation of the loop which was used for retraction of maxillary central incisor was analyzed by Finite Element Method. We observed the following results: 1) We could control the stress distribution on the periodontal ligament by proper moment/force ratio on maxillary right central incisor and predict the pattern of movement of maxillary right central incisor. 2) The amount of stress on the periodontal ligament as well as the moment/force ratio demanded by each pattern of movement increased as the destruction of alveolar bone was worse. 3) The moment/force ratio demanded by each pattern of movement decreased as the angle between the maxillary central incisor and occlusal plane decreased. 4) The force with the open loop was shown to be large compared to that with the closed loop. Also, the force with the helix decreased by 30% compared to that without the helix. 5) Under the same conditions we observed a larger moment/force ratio when the open loop and/or the helix were used.

  • PDF

Cone-beam computed tomography-based diagnosis and treatment simulation for a patient with a protrusive profile and a gummy smile

  • Uesugi, Shunsuke;Imamura, Toshihiro;Kokai, Satoshi;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.189-199
    • /
    • 2018
  • For patients with bimaxillary protrusion, significant retraction and intrusion of the anterior teeth are sometimes essential to improve the facial profile. However, severe root resorption of the maxillary incisors occasionally occurs after treatment because of various factors. For instance, it has been reported that approximation or invasion of the incisive canal by the anterior tooth roots during retraction may cause apical root damage. Thus, determination of the position of the maxillary incisors is key for orthodontic diagnosis and treatment planning in such cases. Cone-beam computed tomography (CBCT) may be useful for simulating the post-treatment position of the maxillary incisors and surrounding structures in order to ensure safe teeth movement. Here, we present a case of Class II malocclusion with bimaxillary protrusion, wherein apical root damage due to treatment was minimized by pretreatment evaluation of the anatomical structures and simulation of the maxillary central incisor movement using CBCT. Considerable retraction and intrusion of the maxillary incisors, which resulted in a significant improvement in the facial profile and smile, were achieved without severe root resorption. Our findings suggest that CBCT-based diagnosis and treatment simulation may facilitate safe and dynamic orthodontic tooth movement, particularly in patients requiring maximum anterior tooth retraction.

En-masse retraction with a preformed nickel-titanium and stainless steel archwire assembly and temporary skeletal anchorage devices without posterior bonding

  • Jee, Jeong-Hyun;Ahn, Hyo-Won;Seo, Kyung-Won;Kim, Seong-Hun;Kook, Yoon-Ah;Chung, Kyu-Rhim;Nelson, Gerald
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.236-245
    • /
    • 2014
  • Objective: To evaluate the therapeutic effects of a preformed assembly of nickel-titanium (NiTi) and stainless steel (SS) archwires (preformed C-wire) combined with temporary skeletal anchorage devices (TSADs) as the sole source of anchorage and to compare these effects with those of a SS version of C-wire (conventional C-wire) for en-masse retraction. Methods: Thirty-one adult female patients with skeletal Class I or II dentoalveolar protrusion, mild-to-moderate anterior crowding (3.0-6.0 mm), and stable Class I posterior occlusion were divided into conventional (n = 15) and preformed (n = 16) C-wire groups. All subjects underwent first premolar extractions and en-masse retraction with preadjusted edgewise anterior brackets, the assigned C-wire, and maxillary C-tubes or C-implants; bonded mesh-tube appliances were used in the mandibular dentition. Differences in pretreatment and post-retraction measurements of skeletal, dental, and soft-tissue cephalometric variables were statistically analyzed. Results: Both groups showed full retraction of the maxillary anterior teeth by controlled tipping and space closure without altered posterior occlusion. However, the preformed C-wire group had a shorter retraction period (by 3.2 months). Furthermore, the maxillary molars in this group showed no significant mesialization, mesial tipping, or extrusion; some mesialization and mesial tipping occurred in the conventional C-wire group. Conclusions: Preformed C-wires combined with maxillary TSADs enable simultaneous leveling and space closure from the beginning of the treatment without maxillary posterior bonding. This allows for faster treatment of dentoalveolar protrusion without unwanted side effects, when compared with conventional C-wire, evidencing its clinical expediency.

Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구 (A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics)

  • 임강순;차경석;이진우
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.303-312
    • /
    • 2004
  • 전치의 후방 견인시 교정력은 치아의 저항중심에서 벗어난 브라켓을 통해 적용되기 때문에 바람직하지 못한 경사이동이 발생하게 되고 이를 방지하기 위한 여러 가지 방법 중 호선에 curve나 전치부 호선에 치근 설측 토그를 부여하는 방법이 많이 사용된다. 이에 본 연구는 combination loop archwire와 hook을 이용한 활주역 학을 이용하여 전치를 후방 견인 시, compensating curve를 0도, 15도, 30도 부여하고, 이 때 나타나는 효과를 광탄성법으로 비교 연구하기 위하여 치아와 치조골 모형을 광탄성 모형으로 대체시키고 와이어와 브라켓을 주어진 조건으로 위치시 킨 후 편광판을 이용하여 초기 응력 상태를 분석하여 다음과 같은 결과를 얻었다. 1. Combination loop archwire와 활주역학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 전치부 치근단 부위의 최대 무의차수가 감소하였다. 2. Combination loop archwire와 활주역 학으로 전치를 후방 견인 시 compensating curve가 0도, 15도, 30도로 증가할수록 견치와 소구치 부위의 최대 무의차수가 증가하였다. 3. Combination loop archwire로 전치를 견인할 때보다 동일한 힘을 사용하여 활주역 학으로 견인할 때 전치부 치근단 부위에서 다소 낮은 무의차수를 나타내었다. 이상의 결과에서 Combination loop archwire와 활주역학을 이용한 상악전치의 후방 견인시 견인방법에 큰 차이 없이 호선에 부여한 compensating curve는 전치의 설측 경사이동 양상을 어느 정도 감소시킬 수 있음을 확인하였다. 또한 힘의 적용위치가 저항중심에 더욱 가까운 hook을 이용한 활주 역학이 전치의 설측경사 방지에 더 효과적일 것으로 판단된다.가 높게 나타나는 현상을 부분적으로 설명하여 주는 것으로 사료된다.용한 정보를 제공할 수 있을 것으로 보인다.ing할 경우, arch perimeter의 증가량은 Curve of Spee의 최대 길이의 1/2보다 적게 나타났다.$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $61\%$ 수준이었으며, Non-etched Foil-Mesh base에서 최저 Peel 결합 강도$(_{60}PBS)$는 전단결합강도(SBS)의 $34\%$ 수준이었으며, 인장결합강도(TBS)에 대해서는 $55\%$ 수준이었다. 4. 단위 면적 당 결합강도에 있어서 전단결합강도(SBS)와 인장결합강도(TBS) 및 $75^{\circ}\;와\;90^{\circ}$ peel 결합강도는 Micro-Loc base와 Chessboard base에서 차이 가 없었으며 Non-etched Foil-Mesh base에서 가장 작았고(p<0.05), $0^{\circ},\;15^{\circ},\;30^{\circ},\;60^{\circ}$ peel응력을 적용한 결과 Chessboard base에서 가장 큰 Peel결합강도를, Non-etched Foil-Mesh base에서 가장 작은 결합강도를 보였다(p<0.05).았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적 매끄러운 표면을 보이고, Unitek사의 경우 압흔과 함께 pitting 이 관찰되며, Ormco Stainless Steel의 경우 불규칙한 pitting이 다수 존재했다