• 제목/요약/키워드: Ansoft Maxwell Program

검색결과 14건 처리시간 0.023초

무전극 형광램프를 위한 유도코일의 전자계 해석 (Electromagnetic Analysis of Induction Coil for Electrodeless Fluorescent lamps)

  • 김광수;이종찬;박대희;박성목
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.187-190
    • /
    • 2002
  • The Electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(Ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux B, H by changing the input current.

  • PDF

페라이트를 이용한 환형 무전극 램프의 전자계 특성 (Electromagnetic Properties of Ring -Shaped Electrodeless Fluorescent Lamps for Ferrite Core)

  • 조주웅;이성진;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.249-251
    • /
    • 2003
  • The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the line time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

환형 무전극 램프의 광학적, 전자계적 해석 (Analysis of Optical and Electromagnetic Distribution of Ring-shaped Electrodeless Fluorescent Lamps)

  • 조주웅;최용성;김용갑;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.460-464
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by D simulation software operated at 250KHz and some specific conditions. Photometric characteristic of the ring-shaped electrodeless fluorescent lamp were investigated using LS-100 lightmeter and TA-0510 thermometer respectively.

풍력터빈 적용을 위한 PMSG용 영구자석의 와전류손실에 관한 연구 (A Study on the Eddy Current Loss of the Permanent Magnet for PMSG for the Wind Turbine Application)

  • 최만수;문채주;쑨루이;장영학;박태식;정문선;곽승훈
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.8-15
    • /
    • 2014
  • The objective of this paper is to suggest a design topology of permanent magnet synchronous generator with 2,000kW capacities for wind turbine. The suggested topology is to provide 3 split magnet PMSG instead of single magnet, and performed an analysis of eddy current loss and iron loss for suggested type using ansoft maxwell commercial program. The simulation results of suggested magnet type show there duction of eddy current loss as 13.87kW with loadless conditions and23.48kW with rated conditions, but iron loss for rotor yoke show the in creasing trend as2.2kW with loadless conditions and 0.2kW with rated conditions. The suggested 3 split maget type is to identified as more useful for 2,000kW PMSG.

풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구 (A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine)

  • 최만수;장영학;박태식;정문선;문채주
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

환형 무전극 램프의 전자계 분포특성 (Electromagnetic distribution looped Electrodeless Fluorescent Lamps)

  • 조주웅;이성진;최용성;김용갑;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.312-315
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions.

  • PDF

환형 무전극 형광램프의 전자계특성 (Electromagnetic Properties of Ring-Shaped Electrodeless Fluorescent Lamps)

  • 조주웅;이성진;최용성;김용갑;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.521-524
    • /
    • 2003
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250kHz and some specific conditions.

  • PDF

환형 무전극 형광램프의 최적 설계를 위한 특성조건 분석 (A study on Properties Condition for the most suitable design of the Ring-shaped electrodeless fluorescent lamp)

  • 조주웅;이성진;남중희;최용성;김용갑;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.211-214
    • /
    • 2004
  • The advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours and is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[kHz] and some specific conditions

  • PDF

무전극 전구형 형광램프의 전자계 해석 (Electromagnetic Field Analyses of Electrodeless Fluorescent Lamp)

  • 김광수;이종찬;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.67-70
    • /
    • 2002
  • The electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. but Increasing awareness of electromagnetic compatibility(EMC) issues in lighting application, the problems of interference generation by electrodeless fluorescent lighting system have been highlighted. In this paper, Maxwell 2D finite element analysis program(ansoft) is used to obtain electromagnetic properties associated with the coil and nearby structures. and also evaluated Flux, B, H, by changing the input current.

  • PDF

환형 무전극 램프의 광학적, 전자계적 특성 (Optical and Electromagnetic Distribution of Ring-shaped Electrodeless Fluorescent Lamps)

  • 조주웅;이성진;최용성;김용갑;박대희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.161-163
    • /
    • 2003
  • Ring-shaped electrodeless fluorescent lamp is removed the internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficacy replacement for the incandescent reflector lamp in many applications. In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250[㎑]and some specific conditions. The optical measurement measured luminance and a temperature and an optical spectrum distribution for 10 minutes in a one minute interval at the same time.

  • PDF