• 제목/요약/키워드: Anodized

검색결과 338건 처리시간 0.025초

Fabrication of Wafer-Scale Anodized Aluminum oxide(AAO)-Based capacitive biosensor

  • Kim, Bongjun;Oh, Jeseung;Yoo, Kyunghwa
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.372.2-372.2
    • /
    • 2016
  • Various nanobiosensors have been developed and extensively investigated. For their practical applications, however, the reproducibility and uniformity should be good enough and the mass-production should be possible. To fabricate anodized aluminium oxide (AAO)-based nanobiosesnor on wafer scale, we have designed and constructed a wafer-scale anodizing system. $1{\mu}m$-thick-aluminum is deposited on 4 inch SiO2/Si substrate and then anodized, resulting in uniform nanopores with an average pore diameter of about 65 nm. Furthermore, most AAO sensors constructed on this wafer provide capacitance values of 30 nF ~ 60 nF in PBS, demonstrating their uniformity.

  • PDF

Microfabrication of Vertical Carbon Nanotube Field-Effect Transistors on an Anodized Aluminum Oxide Template Using Atomic Layer Deposition

  • Jung, Sunghwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1169-1173
    • /
    • 2015
  • This paper presents vertical carbon nanotube (CNT) field effect transistors (FETs). For the first time, the author successfully fabricated vertical CNT-based FETs on an anodized aluminum oxide (AAO) template by using atomic layer deposition (ALD). Single walled CNTs were vertically grown and aligned with the vertical pores of an AAO template. By using ALD, a gate oxide material (Al2O3) and a gate metal (Au) were centrally located inside each pore, allowing the vertical CNTs grown in the pores to be individually gated. Characterizations of the gated/vertical CNTs were carried and the successful gate integration with the CNTs was confirmed.

Al장극산화법에 의한 반휴분이용 다공성 격영의 제조에 관한 연구 (A Study on the Manufacturing of Porous Membrane for Separation of Gas Mixture by Al Anodizing Method)

  • 윤은열;라경용
    • 한국표면공학회지
    • /
    • 제15권2호
    • /
    • pp.69-76
    • /
    • 1982
  • With a view to manufacturing membranes for separation of gas mixtures, Al foils were anodized in a 2% oxalic-acid electrolyte at 40V and 80V. When anodizing was completed and Barrier layer existed at the extreme back site of the foil, the anodized foil was made to react with only electrolyte, with switching off the electric power. When the size and density of pores were changed through voltage change, the membr-anes did not show large difference in the permeability. Reacting with electrolyte, the existing Barrier layer turns into porous layer. During this process, several small pores grow from one relatively large pore, getting to the back site. The number and size of the small pores getting to the back surface increase as time passing. This change of Barrier layer into porous layer is thought to be directly related to the permeability change of the membranes. The selectivity of an anodized Al membrane was not related to the voltage change, and was high, being similar to the theoretical selctivity of metallic membranes, according to my observation.

  • PDF

Al 6061 합금 양극산화피막의 성장과 부식특성에 미치는 혼합 전해용액의 영향 (Effect of the Mixed Electrolyte on the Film Growth and Corrosion Characteristics of Anodized Al 6061 Alloy)

  • 류한웅;김용환;정우창;정원섭
    • 한국재료학회지
    • /
    • 제17권5호
    • /
    • pp.244-249
    • /
    • 2007
  • The properties of anodized films on aluminum 6061 alloy in single electrolyte of sulfuric acid and mixed electrolyte of sulfuric-boric acid and sulfuric-boric-nitric acid have been studied. Polarization tests in NaC solution were used to investigate the corrosion performance. Characteristics of film formation and surface morphology were examined by optical microscopy, FE-SEM and EDS. The results obtained have indicated that oxide films growth have been promoted by nitric acid and anodized films in mixed electrolyte have superior corrosion resistance. In case of anodic films formed in mixed electrolyte, some grooves and numerous crazings were also observed at the surface.

후열처리에 의한 알루미늄 산화층의 특성 향상 (Enhanced Properties of Aluminum Oxide Layers with Post Heat Treatment)

  • 전윤남;김상준;박지현;정나겸
    • 한국표면공학회지
    • /
    • 제52권5호
    • /
    • pp.275-281
    • /
    • 2019
  • Anodization is widely used to enhance the properties of aluminum, such as hardness, electric resistance, abrasion resistance, corrosion resistance etc. But these properties can be enhanced with additional process. According to the partial crystallization of oxide layer with post heat treatment, enhanced hardness can be expected with partial crystallization. In this study, post heat treatments were applied to the anodized aluminum alloys of Al6061 to achieve the partial crystallization, and crystallizations were evaluated with the reduced breakdown voltages. Interestingly, remarkable enhanced hardness (21~29%), abrasion resistance (26~62%), and reduced breakdown voltage (24~44%) were observed for the sulfuric acid anodized samples when we annealed the anodized samples with 1hour post heat treatment at $360^{\circ}C$. For the Al5052 alloys, a lot of cracks were observed when we applied the post heat treatment.

알루미늄 6061 합금 양극산화 후 열처리에 따른 표면 특성 관찰 (Effects of Heat Treatment on Surface Properties of Aluminum 6061 Alloy After Anodization)

  • 이승민;정찬영
    • Corrosion Science and Technology
    • /
    • 제21권6호
    • /
    • pp.495-502
    • /
    • 2022
  • Anodization is a representative electrochemical surface treatment method that can improve both heat resistance and corrosion resistance by forming an anodization film on the surface of the aluminum. However, these properties can be changed after an additional heat treatment process. In this study, Al 6061 was subjected to an anodization process at 60 V for 1 hour, 5 hours, or 9 hours. An additional heat treatment process was performed at 500 ℃ for 30 minutes. Field emission scanning electron microscopy (FE-SEM) analysis revealed that the thickness of the anodized film was increased in proportion to the anodization time. Both pore size and pore diameter of the anodized film was also increased after anodization. After an additional heat treatment process, there were no significant changes in the thickness, pore size, or pore diameter of the anodized film. Heat resistance was confirmed through thermal analysis and chemical resistance was evaluated with a potentiodynamic polarization test.

In vivo와 in vitro 에서 양극산화 처리한 타이타늄 시편의 상대적인 생체적합성 평가 (Relative Biocompatibility Evaluation of Anodized Titanium Specimens in vivo and in vitro)

  • 이유미;이은정;염동선;김도순;이성태;김병일;조현욱
    • 생명과학회지
    • /
    • 제16권2호
    • /
    • pp.302-309
    • /
    • 2006
  • 처리하지 않은 타이타늄과 양극 산화 처리한 타이타늄 시편의 생체적합성을 평가하기 위해, 시편을 마우스의 복부 피하 조직에 이식하고 2주 동안 생존시켰다. 그 시편에 대한 복부 피하 결합조직의 반응을 조직학적으로 조사하였다. 시편 주위를 둘러싸는 섬유성 결합조직 막이 관찰되었으며 이 막은 섬유모세포, 섬유세포 및 기타 세포로서 중성호성백혈구, 대식세포, 거대다핵세포 등으로 이루어져 있었다. 시편을 둘러싸는 이 막에 새로이 형성된 혈관이 존재하기도 하였다. 임플란트와 접하는 섬유성 막에 거대다핵세포가 관찰되었다. 섬유성 막에 있는 세포 종류와 막의 두께를 조사하였다. 막에 있는 대부분의 세포는 섬유모세포와 섬유세포이었다. 양극 산화 처리를 하지 않은 타이타늄 시편에 비해 산화 처리를 한 시편을 둘러싸는 섬유성 막의 평균 두께가 더 얇았다. 또한 타이타늄 시편의 생체적합성을 세포 배양법으로 조사하였다. 산화 처리를 한 시편 위에서 배양한 MG-63 세포의 수가 유의하게 증가되었다. 이런 결과들은 in vivo 와 in vitro 실험에서 산화 처리를 한 타이타늄 시편이 생체적합성을 증가시키는데 효과적이라는 것을 말해준다.

타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구 (Wettability of titanium implants depending upon surface properties)

  • 한영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.12-20
    • /
    • 2009
  • 연구목적: 임플란트가 식립되어질 때 매식체는 조직액과 접촉하게 된다. 임플란트의 조직액 흡착은 표면처리에 따라 다양하게 나타난다. 이 때 임플란트 시편의 표면 거칠기와 젖음성과의 상관관계를 분석하고자 하였다. 연구재료 및 방법: 표면 거칠기와 젖음성의 상관관계를 측정하기 위해 네 종류의 임플란트 시편을 각각 5종류 만들었다. 각각의 그룹은 그룹 A: Machined Surface, 그룹 B: Anodized surface, 그룹 C: RBM (HA blasting) surface, 그룹 D: CMP (calcium methaphosphate) coating surface이다. 연구결과: 1. 표면의 거칠기는 RBM, CMP, Anodized, Machined 그룹 순서로 거칠었다. RBM과 CMP는 통계적으로 유의차가 없었다 (P<.05). 2. 젖음성은 Anodized, RBM, CMP, Machined 그룹 순서로 높았다. CMP와 Machined는 통계적으로 유의차가 없었다 (P<.05). 3. 표면 거칠기와 젖음성과의 상관관계는 없었다.

CELLULAR RESPONSES ON ANODIZED TITANIUM DISCS COATED WITH $1{\alpha}$,25-DIHYDROXYVITAMIN D3 INCORPORATED POLY (D,L-LACTIDE-CO-GLYCOLIDE) (PLGA) NANOPARTICLES

  • Cho, Young-Jin;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Joo-Hee
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.620-627
    • /
    • 2008
  • STATEMENT OF PROBLEM: A biochemical approach for surface modification has offered an alternative for physicochemical and morphological methods to obtain desirable bone-implant interfaces. PURPOSE: The purpose of the present study was to investigate cell responses to poly (D,L-lactide-co-glycolide) (PLGA)/$1{\alpha}$,25-(OH)$_2D_3$ coating with reference to cellular proliferation and differentiation in vitro. MATERIAL AND METHODS: 96 titanium discs were fabricated and divided into four groups. Group 1 was anodized under 300 V as control. Group 2, 3 and 4 were anodized then coated with 3 ml PLGA/$1{\alpha}$,25-(OH)$_2D_3$ solutions. Amount of the solutions were 2 ul, 20 ul and 200ul respectively. The osteoblast-like Human Osteogenic Sarcoma (HOS) cells were seeded and cultured for 1, 3 and 7 days. MTSbased cell proliferation assay and ALPase activity test were carried out. RESULTS: PLGA nanoparticles were observed as fine, smooth and round and HOS cells attached to the anodized surfaces through strand-like and sheet-like filopodia. After 3 days of culture, the dendritic filopodia were exaggerated and sheet-like cytoplasmic projections covered the coated titanium surfaces. After 3 days of culture, all of the groups showed increased cellular proliferation and the lowest proliferation rate was measured on group 2. Higher amount of incorporated $1{\alpha}$,25-(OH)$_2D_3$ (Group 3 and 4) improved cellular proliferation but the differences were not significant statistically (P > .05). But they increased the rate of ALP activities than the control group at day 3 (P < .05). CONCLUSION: Biodegradable PLGA nanoparticles incorporated with vitamin D metabolite positively affected proliferation and differentiation of cells on the anodized titanium surface.