• 제목/요약/키워드: Anodic Aluminum Oxide(AAO)

검색결과 129건 처리시간 0.028초

누름가공과 AAO 공정을 이용한 나노-마이크로 복합패턴 제작방법 연구 (A Study on Manufacturing Method of Nano-Micro Hybrid Pattern Using Indentation Machining Method and AAO Process)

  • 김한희;전은채;최대희;장웅기;박용민;제태진;최두선;김병희;서영호
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.63-68
    • /
    • 2015
  • Micro/nano patterns for optical concentration and diffusion have been studied in the various fields such as displays, optics, and sensors. Conventional micro patterns were continuous and linear shapes due to using linear-type light sources, however, recently non-continuous patterns have been applied as point sources are used for dot-type light sources such as LEDs and OLEDs. In this study, a hybrid machining technology combining an indentation machining method and an AAO process was developed for manufacturing the non-continuous micro patterns having nano patterns. First, mirror-like surfaces ($R_a<20nm$) of pure Aluminum substrates were obtained by optimizing cutting conditions. Then, The letter of 'K' consisting of the arrays of the micro patterns was manufactured by the indentation machining method which has a similar principle to indentation hardness testing. Finally, nano patterns were machined by AAO process on the micro patterns. Conclusively, a specific letter having nano-micro hybrid patterns was manufactured in this study.

Co계 자성합금 나노와이어의 특성에 영향을 미치는 전기화학적 변수 (Electrochemical Factors Affecting the Magnetic Properties of Co based Magnetic Nanowires)

  • 이종욱;박호동;이관희;김긍호;정원용
    • 전기화학회지
    • /
    • 제8권3호
    • /
    • pp.125-129
    • /
    • 2005
  • 본 연구에서는 고순도 알루미늄 호일$(t=300{\mu}m)$양극산화 공정을 통해 AAO 나노템플레이트를 자체 제조하였고, 이렇게 제조된 형틀을 가지고 교류 나노전주법에 의해 경자성 합금인 CoP와 연자성 합금인 CoFe를 나노와이어로 제조하였다. 대표적인 Co계 자성합금인 CoP와 CoFe나노와이어는 각기 독특한 자기적 성질을 나타내었다. 경자성 CoP 합금 나노와이어의 경우 교류 인가전압에 따라 hcp와 fcc가 혼재된 구조가 형성되어 자기적 특성에 영향을 미쳤다. 또한 높은 포화자화 값을 갖는 CoFe연자성 합금 나노와이어는 박막 도금 시와는 달리 이상합금도금현상이 거의 나타나지 않았으며 $Co_{30}Fe_{70}$에서 가장 좋은 238emu/g의 포화자화 값을 나타내었다.

호흡기를 통한 약액 전달을 위한 진세노사이드 초미세입자 분무장치 제작 (Fabrication of an ultra-fine ginsenoside particle atomizer for drug delivery through respiratory tract)

  • 이병철;박진수;양웅모
    • 대한융합한의학회지
    • /
    • 제2권1호
    • /
    • pp.5-12
    • /
    • 2021
  • Objectives: The purpose of this study is to fabricate an ultra-fine ginsenoside particle atomizer that can provide a new treatment method by delivering ginsenoside components that have a therapeutic effect on respiratory diseases directly to the lungs. Methods: We fabricated the AAO vibrating mesh by using the micromachining process. The starting substrate of an AAO wafer has a 350nm pore diameter with 50㎛ thickness. A photomask having several 5㎛ opening holes with a 100㎛ pitch was used to separate each nanopore nozzle. The photoresist structure was optimized to pattern the nozzle area during the lift-off process precisely. The commercial vibrating mesh was removed from OMRON's NE-U100 product, and the fabricated AAO vibrating mesh was installed. A diluted sample of 20mL with 30% red ginseng concentrate was prepared to atomize from the device. Results: As a result of liquid chromatography analysis before spraying the ginsenoside solution, ginsenoside components such as 20S-Rg3, 20R-Rg3, and Rg5 were detected. After spraying through the AAO vibrating mesh, ginsenosides of the same component could be detected. Conclusion: A nutrient solution containing ginsenosides was successfully sprayed through the AAO vibrating mesh with 350 nm selective pores. In particular, during the atomizing experiment of ginsenoside drug solution having excellent efficacy in respiratory diseases, it was confirmed that atomizing through the AAO vibrating mesh while maintaining most of the active ingredients was carried out.

양극산화 공정시간에 따른 알루미늄 5052 합금의 산화피막 성장 및 내식성 관찰 (Observation of Corrosion Behavior with Aluminum 5052 Alloy by Modulating Anodization Time)

  • Ji, HyeJeong;Choi, Dongjin;Jeong, Chanyoung
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.67-67
    • /
    • 2018
  • The 5xxx series aluminum alloys are recently used in not only marine system but also automotive area because of a low density material, good mechanical properties and better resistance to corrosion. However, Aluminum alloys are less resistant than the purest aluminum such as 1xxx aluminum alloy. Electrochemical anodization technique has attracted in the area of surface treatment because of a simple procedure, a low-cost efficiency than other techniques such as lithography and a large volume of productivity, and so on. Here, The relationship between the corrosion behavior and the thickness of aluminum anodic oxide have been studied. Prior to anodization, The 5052 aluminum sheets ($30{\times}20{\times}1mm$) were degreased by ultra-sonication in acetone and ethanol for 10 minutes and eletropolished in a mixture of perchloric acid and ethanol (1:4, volume ratio) under an applied potential of 20V for 60 seconds to obtain a regular surface. During anodization process, Aluminum alloy was used as a working electrode and a platinum was used as a counter electrode. The two electrodes were separated at a distance of 5cm. The applied voltage of anodization is conducted at 40V in a 0.3M oxalic acid solution at $0^{\circ}C$ with appropriate magnetic stirring. The surface morphology and the thickness of AAO films was observed with a Scanning Electron Microscopy (SEM). The corrosion behavior of all samples was evaluated by an open-circuit potential and potentio-dynamic polarization test in 3.5wt% NaCl solution. Thus, The corrosion resistance of 5052 aluminum alloy is improved by the formation of an anodized oxide film as function of increase anodization time which artificially develops on the metal surface. The detailed electrochemical behavior of aluminum 5052 alloy will be discussed in view of the surface structures modified by anodization conditions such as applied voltages, concentration of electrolyte, and temperature of electrolyte.

  • PDF

폐암 바이오마커 검출용 나노SPR 바이오센서 (Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker)

  • 장은윤;염세혁;엄년식;한정현;김형경;신용범;강신원
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.

Pd 촉매금속의 표면형상 변형에 의한 고감도 MEMS 형 마이크로 수소가스 센서 제조공정 (Highly Sensitive MEMS-Type Micro Sensor for Hydrogen Gas Detection by Modifying the Surface Morphology of Pd Catalytic Metal)

  • 김정식;김범준
    • 한국재료학회지
    • /
    • 제24권10호
    • /
    • pp.532-537
    • /
    • 2014
  • In this study, highly sensitive hydrogen micro gas sensors of the multi-layer and micro-heater type were designed and fabricated using the micro electro mechanical system (MEMS) process and palladium catalytic metal. The dimensions of the fabricated hydrogen gas sensor were about $5mm{\times}4mm$ and the sensing layer of palladium metal was deposited in the middle of the device. The sensing palladium films were modified to be nano-honeycomb and nano-hemisphere structures using an anodic aluminum oxide (AAO) template and nano-sized polystyrene beads, respectively. The sensitivities (Rs), which are the ratio of the relative resistance were significantly improved and reached levels of 0.783% and 1.045 % with 2,000 ppm H2 at $70^{\circ}C$ for nano-honeycomb and nano-hemisphere structured Pd films, respectively, on the other hand, the sensitivity was 0.638% for the plain Pd thin film. The improvement of sensitivities for the nano-honeycomb and nano-hemisphere structured Pd films with respect to the plain Pd-thin film was thought to be due to the nanoporous surface topographies of AAO and nano-sized polystyrene beads.

복합 박막 증착 공정을 이용한 중저온 고체산화물 연료전지용 전해질 증착 (Deposition of Electrolyte for Intermediate Temperature Solid Oxide Fuel Cells by Combined Thin Film Deposition Techniques)

  • 하승범;지상훈;와카스 하산 탄비르;이윤호;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.84.1-84.1
    • /
    • 2011
  • Typical solid oxide fuel cells (SOFCs) have limited applications because they operate at high temperature due to low ionic conductivity of electrolyte. Thin film solid oxide fuel cell with yttria stabilized zirconia (YSZ) electrolyte is developed to decrease operating temperature. Pt/YSZ/Pt thin film SOFC was fabricated on anodic aluminum oxide (AAO). The crystalline structure of YSZ electrolyte by sputter is heavily depends on the roughness of porous Pt layer, which results in pinholes. To deposit YSZ electrolyte without pinholes and electrical shortage, it is necessary to deposit smoother and denser layer between Pt anode layer and YSZ layer by sputter. Atomic Layer Deposition (ALD) technique is used to deposit pre-YSZ layer, and it improved electrolyte quality. 300nm thick Bi-layered YSZ electrolyte was successfully deposited without electrical shortage.

  • PDF

Electrodeposition법으로 제조한 Ni-Fe 나노박막 및 나노선의 특성에 미치는 용액 조성의 영향 (Effect of Solution Compositions on Properties of Ni-Fe Nano Thin Film and Wire Made by Electrodeposition Method)

  • 구본급
    • 한국표면공학회지
    • /
    • 제43권5호
    • /
    • pp.243-247
    • /
    • 2010
  • The micro Vickers hardness and internal stress of Ni-Fe metal thin film synthesized by electrodeposition method at $25^{\circ}C$ were studied as a function of bath composition, and surface microstructure and atomic compositions of thin films were investigated by SEM and EDS. And the shape change of $200\;{\AA}$ Ni-Fe nanowires made using anodic aluminum oxide(AAO) templates by electrodeposition method were observed by SEM as a function of ultrasonic treatment time and bath composition. The Fe deposition contents on the substrate non-linearly increased with Fe ion concentration over total metal ion concentration. In case of low Fe contents film, the grain size is smaller and denser than high Fe contents deposited films, and the micro Vickers hardness increased with Fe contents of electrodeposited films. These results affected the shape change of nanowire after ultrasonic treatments.

고감도 화학물질 검출을 위한 대면적 Ag 코팅 고분자 나노기둥 SERS 활성 기판 제작

  • 임하나;김안나;이호년;김현종
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.92.1-92.1
    • /
    • 2018
  • 표면증강 라만 산란(Surface Enhancement Raman Scattering, SERS) 기판의 경우, 규칙적인 배열을 갖는 나노구조 및 나노패턴 기판과 금속 나노구조의 고밀도 패킹이 고감도 화학물질 검출에 중요하다. 또한 폭넓은 응용 가능성에도 불구하고 기판 제작의 비용이 높고 재현성이 떨어져 상용화에 어려움을 겪고 있다. 본 연구에서는 다공성 알루미나(Anodic Aluminum Oxide, AAO)를 사용하여 Ag 나노입자가 코팅된 나노기둥 배열(Nanopillar array)을 갖는 고분자 필름의 SERS-active 기판을 제작하여 공정비용을 낮추고, 대면적화로 생산성을 높이고자 한다. 다단계 양극산화 공정과 복제 기술을 통해 다양한 지름과 높이를 갖는 맥주병 형상의 나노기둥 배열을 제조하였고, aspect ratio가 2.3인 나노기둥 배열에서 최대의 SERS 신호 강도와 높은 재현성을 확인하였다. SERS 신호의 세기는 Ag 나노입자가 코팅된 나노기둥 배열의 열처리 온도와 분석 물질의 농도에 따라 비례하며 이를 바탕으로 정량적인 고감도 진단, 바이오 화학 물질 센서에 매우 적합함을 알 수 있다.

  • PDF