• Title/Summary/Keyword: Annular Fins

Search Result 13, Processing Time 0.02 seconds

EFFECTS OF FIN SPACING ON CONVECTIVE HEAT TRANSFER FOR A CIRCULAR CYLINDER WITH ANNULAR FINS (환상핀이 부착된 원봉에서 핀 간격에 따른 대류열전달 해석)

  • Park, Tae Seon;Kim, Chang Ha
    • Journal of computational fluids engineering
    • /
    • v.19 no.2
    • /
    • pp.1-7
    • /
    • 2014
  • This study is to analyze the local convective heat transfer for a circular cylinder with annular fins. The relation between wall heat transfer and three-dimensional flow is investigated for different distances of annular fins. Depending on the fin spacing, the flow structure is strongly changed by the variation of horseshoe vortices. As the fin spacing increases, the heat transfer rate is maximized at a certain condition. This is clearly obtained as the Reynolds number increases, and it is closely related to the development of horseshoe vortices.

Local Convective Mass Transfer and Flow Structure Around a Circular Cylinder with Annular Fins (환상핀이 부착된 원봉 주위의 3차원 박리 유동구조 및 물질전달 특성 해석)

  • 박태선;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2132-2146
    • /
    • 1991
  • Extensive experiments were carried out to investigate the mass transfer and flow structures around a circular cylinder with annular fins in crossflow. The naphthalene sublimation method was employed to measure the circumferential and longitudinal variations of mass transfer from the circular cylinder between annular fins and H is the height of the fin from the cylinder surface. A remarkable enhancement of mass transfer due to the horseshoe vortices was observed near the corner junction between the annular fin and circular cylinder. The present results indicate that the local circumferential Sherwood number shows the higher values on the front stagnation point. The maximum augmentation of mass transfer rate at the center of cylinder is found near L/H-0.15 due to the separation bubble along the annular fins. The secondary flows, which are the corner vortices V2 and V3 near the end wall of the annular fin, are fairly predicted from the distributions of local Sherwood number in the spanwise direction. The average Sherwood number of overall surface at L/H=0.15 is larger 2.0 times than that of without annualr fins. The correlations of total average mass transfer rate with L/H and Re$_{L}$ can also be obtained.d.

Heat transfer on annular fins with one-dimensional radiative and convective heat exchange (원형휜에서 열전달 특성분석)

  • 이금배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1621-1628
    • /
    • 1990
  • Numerical solutions are presented for the heat transfer from radiating and convecting fins. Consideration is given to thin, annular fins attached to a tube surface for which the temperature is constant. Fin to fin, fin to base, and fin to environment radiative interactions are considered. It is assumed that the radiating surface is diffuse-gray, the environment is black, and the surrounding fluid is transparent. The radiation terms are formulated by using Poljak's net-radiation methoad. The mathematical description of the simultaneously heat transport by conduction, convection, and radiation leads to a nonlinear integro-differential equation. This has been solved for a wide range of the pertinent physical parameters by using finite difference method and iteration method based on the Newton-Raphson technique. The temperature distributions, heat transfer rates, fin efficiencies, and fin effectivenesses are presented in dimensionless form. The results definitely indicate that the use of fins leads to a significant increase in heat transfer compared with the unfinned tube.

An experimental study on the effects of an inserted coil on flow patterns and heat transport performances for a horizontal rotating heat pipe (수평 회전 히트파이프에서 내부 삽입 코일이 유동 형태 및 열전달 성능에 미치는 영향에 대한 실험 연구)

  • 이진성;김철주;김선주;문석환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.763-772
    • /
    • 1998
  • The effects of an inserted coil on flow patterns and heat transport performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low RPM(less than 1,000 RPM), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing RPM. The pumping effects for RHP with an inserted coil resulted enhancement both in condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher RPM(above 1,000∼1,200) with the transition of flow regime to annular flow.

  • PDF

An Experimental Study on the Effects of ...an Inserted Coil on Flow Patterns pd. Beat Transport Performances for a Horizontal Rotating Heat Pipe

  • Lee, Jin-Sung;Kim, Chul-Ju;Kim, Bong-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.50-61
    • /
    • 2000
  • The effects of an inserted coil on flow . patterns and heat transfer performance for a horizontal rotating heat pipe have been studied experimentally. Especially, the present study is to see an internally inserted helical coil inside a RHP would lead to the same kind of results as internal fins. Visualization test conducted for an acryl tube, charged water with at a volumetric rate of 20%. When the flow kept pool regime at a low rpm(less than 1,000rpm), the movement of coil forced the water to flow in axial direction. But this pumping effect of coil disappeared, when the pool regime changed to annular one which could be created by increasing rpm. The pumping effects for RHP with an inserted coil resulted in the enhancement in both condensation heat transfer coefficient and heat transport limitation, as obtained in case of using internal fins. But all these effects became negligible in the range of higher rpm(above 1,000-1,200) with the transition of flow regime to annular flow.

  • PDF

Numerical Analysis on Combined Convection for a Vertical Cocentric Cylinder with External Fins (외부로 휜이 있는 수직이중관내의 조합대류 유동에 관한 수치적 연구)

  • Sohn, Sang-Suk;Lee, Chae-Moon;Yim, Jang-Soon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.2
    • /
    • pp.118-124
    • /
    • 1985
  • The motion of a fluid in the closed annular cavity formed by two concentric vertical cylinders with externally finned tube has been analysed by a numerical solutions of the equation of momentum and energy. For the calculation procedure, the fluid is assumed to have constant thermo-dynamic and transporties except for the density, which is temperature-dependent in the buoyancy term of the vertical momentum equation (Boussinesq approximation). The govern ins equations for velocity and temperature are solved by a finite difference technique which incoorporates a scheme for treating the coupled variables. Results are presented for a range of the Rayleigh number and for various values of the fin height and the number of fins.

  • PDF

Study on Transient Temperature Distribution in Annular Fin of Uniform Thickness (均一두께 의 원통핀 에서 過渡溫度 分布 에 관한 硏究)

  • 손병진;박희용;이흥주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.3
    • /
    • pp.247-255
    • /
    • 1982
  • The heat diffusion equation for an annular fin is analyzed by Laplace transformation. The fin has a uniform thickness, with its end insulated, and three different temperature profiles at the base such as step change, harmonic and exponential functions. The exact solutions for the temperature and heat flux of the fins are obtained with the infinite series. The series solutions converge rapidly for large values of dimensionless time, but slowly for small values. Therefore some approximate solutions are presented here to fine the temperature distribution and heat flux for small values of dimensionless time. Furthermore a simple approximate heat flux, .OMEGA.=1.13c.tau.$^{1}$2/ is found in the range of .tau. .leg. o.1/c for the exponential function at the base.

The Improvement of the Heat Exchanger Performance by Shape Modifieation(II) (형상변화 에 의한 열교환기 의 열전달 성능 향상 (II))

  • 노승탁;이택식;강신형;이은현;송명호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.202-212
    • /
    • 1985
  • Numerical and experimental studies are presented for turbulent flows and heat transfer in annular channel with circumferential fins on the inner tube in a double pipe heat exchanger. Flow and heat transfer characteristics are periodically fully developed, and complex flow patterns are shown. Numerical calculations are executed by using modified TEACH-2E computer program based on the standard k-.epsilon. turbulence model. Mean velocity, turbulent kinetic energy, and Reynolds stress distributions are measured with the hot wire anemometer. Static pressures on the outer wall of the pipe are measured for three pitch-height ratios and several Reynolds numbers. Numerical predictions generally show reasonable results in comparison with experimental results. When the pitch-height ratio is about 5.0 and other geometric parameters are fixed in this paper, maximum heat transfer is achieved. Reattaching flow patterns appeared in this region. As the pitch between fins is increased beyond 5.0, mean Nusselt numbers are decreased and the pressure drop through one pitch almost remains.

Forced Convection Heat Transfer for Two Circular Tube Arrays with Annular Fins (환형휜이 부착된 두 개의 원형관 배열에 대한 강제대류 열전달)

  • Kim, Seung-iI;Park, Sang-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1093-1101
    • /
    • 2020
  • This study was carried out numerically to investigate the air flow and thermal performance around single and parallel fin-tube heat exchangers and the cooling performance of the fluid inside the heat exchangers. In this study, the air velocity(1~7m/s), the pitch of fin(4, 6.1, 8, 11.3, 18.3, 44mm) and the diameter of fin(31, 33, 35, 37, 39mm) were varied. The flow rate of the water at the fin-tube heat exchanger inlet is 89cc/min and the water temperature is 353K. The air temperature at the upstream region of the heat exchanger is 300K. flow rate of the water at the fin-tube heat exchanger inlet is 80cc/min and the water temperature is 353K. It was found that the air pressure drop around single and parallel fin-tube heat exchangers was highly dependent on the air velocity and the fin pitch, but was independent of the fin diameter. Also, it was shown that pressure drop increased more the parallel arrangements than in single heat exchanger. The temperature difference of water at the inlet and outlet of the heat exchanger depended on the air velocity, the fin pitch and the fin diameter, and it was found that the parallel arrangement method further reduced the temperature of water. It was shown that the Nusselt number increased as the Reynolds number and the fin pitch increased, and decreased as the fin diameter increased.

Counter-Current Gas-Liquid Two-Phase Flow in Narrow Rectangular Channels with Offset Strip Fins (휜이 있는 협소 사각 유로에서 대향류 기/액 2상 유동)

  • Sohn, B.H.;Kim, B.J.;Jeong, S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.229-234
    • /
    • 2001
  • An adiabatic counter-current vertical two-phase flow of air and water in narrow rectangular channels with offset strip fm was investigated experimentally. Tests were systematically performed with downward liquid superficial velocities and upward gas velocities covering 0 to 0.06 m/s and 0 to 2.5 m/s ranges, respectively. Two-phase flow regimes were classified by examining the video images of flow patterns in transparent test sections of 760 mm long and 100 mm wide channel with gaps of 3.0 and 5.0 mm. The channel average void fraction was measured by the quick-closing valve method. Unlike the flow regimes in the channels without fin, where bubbly, slug, chum, and annular flow were identified, only bubbly and chum flow regimes were found for the channels with offset strip fin. However the existence of fin in the channels showed negligible effects on the void fraction. Instead counter-current flow limitations were found to happen at lower air superficial velocity once offset strip fin was introduced in narrow rectangular channels.

  • PDF