• 제목/요약/키워드: Annual exposure dose

검색결과 122건 처리시간 0.025초

Radiological safety assessment of lead shielded spent resin treatment facility with the treatment capacity of 1 ton/day

  • Byun, Jaehoon;Choi, Woo Nyun;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.273-281
    • /
    • 2021
  • The radiological safety of the spent resin treatment facility with a14C treatment capacity of 1 ton/day was evaluated in terms of the external and internal exposure of worker according to operation scenario. In terms of external dose, the annual dose for close work for 1 h/day at a distance of more than 1 m (19.8 mSv) satisfied the annual dose limit. For 8 h of close work per day, the annual dose exceeded the dose limit. For remote work of 2000 h/year, the annual dose was 14.4 mSv. Lead shielding was considered to reduce exposure dose, and the highest annual dose during close work for 1 h/day corresponded to 6.75 mSv. For close work of 2000 h/year and lead thickness exceeding 1.5 cm, the highest value of annual dose was derived as 13.2 mSv. In terms of internal exposure, the initial year dose was estimated to be 1.14E+03 mSv when conservatively 100% of the nuclides were assumed to leak. The allowable outflow rate was derived as 7.77E-02% and 2.00E-01% for the average limit of 20 mSv and the maximum limit of 50 mSv, respectively, where the annual replacement of the worker was required for 50 mSv.

Radiation Exposure from Nuclear Power Plants in Korea: 2011-2015

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.222-228
    • /
    • 2017
  • Background: On June 18, 2017, Korea's first commercial nuclear reactor, the Kori Nuclear Power Plant No. 1, was permanently suspended, and the capacity of nuclear power generation facilities will be adjusted according to the governments denuclearization policy. In these circumstances, it is necessary to assess the quality of radiation safety management in nuclear power plants in Korea by evaluating the radiation dose associated with them. Materials and Methods: The average annual radiation dose per unit, the annual radiation dose per person, and the annual dose distribution were analyzed using the radiation dose database of nuclear reactors for the last 5 years. The results of our analysis were compared to the specifications of the Nuclear Safety Act and Medical Law in Korea. Results and Discussion: The annual average per unit radiation dose of global major nuclear power generation was 720 man-mSv, while that of Korea's nuclear power plants was 374 manmSv. No workers exceeded 50 mSv per year or 100 mSv in 5 years. The individual radiation dose according to occupational exposure was 0.59 mSv for nuclear workers, 1.77 mSv for non-destructive workers, and 0.8 mSv for diagnostic radiologists. Conclusion: The radiation safety management of nuclear power plants in Korea has achieved the best outcomes worldwide, which is considered to be the result of the as-low-as-reasonably-achievable (ALARA) approach and strict radiation safety management. Moreover, the occupational exposures were also very low.

우리나라 응급의료센터 응급구조사의 직업적 방사선 노출 (Occupational Radiation Exposure of Emergency Medical Technicians in Emergency Medical Centers in Korea)

  • 이현경;박정임
    • 한국산업보건학회지
    • /
    • 제27권3호
    • /
    • pp.170-179
    • /
    • 2017
  • Objectives: This study aims to investigate the occupational radiation exposures of emergency medical technicians(EMTs) in emergency medical centers in Korea. The results will provide a basis for developing prevention programs to minimize adverse health effects relating to radiation exposure among emergency medical technicians working in this area. Methods: Radiation exposure doses were measured for twenty-two EMTs working in six emergency medical centers. Thermo Luminescent Dosimeters(TLD) were placed on three representative body parts, including chest, neck, and a finger. Measurements were conducted over the entire working hours of the participants for foor weeks. Dosimeters were analyzed according to a standard method by a KFDA-designated lab. Detection rate, annual radiation exposure dose, and relative levels to dose limit were derived based on the measured doses from the dosimeters. SPSS/Win 18.0 software(IBM, US) was used for statistical analysis. Results: Detection rates were 45.5%, 36.4%, and 45.5% for the dosimeters sampled from chest, neck, and a finger, respectively. The average annual doses were $2.39{\pm}3.44mSv/year$(range 0.38-10.0 mSv/year) for the chest, $2.72{\pm}3.05mSv/year$(2.00-11.34) for the neck, and $20.98{\pm}17.57mSv/year$(1.25-53.50) for the hand dose. The average annual eye dose was estimated to $3.61{\pm}2.37mSv/year$(1.50-8.34). The exposure dose levels of EMTs were comparable to those of radiologists, who showed relatively higher radiation dose among health care workers, as reported in another study. Conclusions: EMTs working in emergency medical centers are considered to be at risk of radiation exposure. Although the radiation exposure dose of EMTs does not exceed the dose limit, it is not negligible comparing to other professionals in health care sectors.

Preliminary Evaluation of Radiological Impact for Domestic On-road Transportation of Decommissioning Waste of Kori Unit 1

  • Dho, Ho-Seog;Seo, Myung-Hwan;Kim, Rin-Ah;Kim, Tae-Man;Cho, Chun-Hyung
    • 방사성폐기물학회지
    • /
    • 제18권4호
    • /
    • pp.537-548
    • /
    • 2020
  • Currently, radioactive waste for disposal has been restricted to low and intermediate level radioactive waste generated during operation of nuclear power plants, and these radioactive wastes were managed and disposed of the 200 L and 320 L of steel drums. However, it is expected that it will be difficult to manage a large amount of decommissioning waste of the Kori unit 1 with the existing drums and transportation containers. Accordingly, the KORAD is currently developing various and large-sized containers for packaging, transportation, and disposal of decommissioning waste. In this study, the radiation exposure doses of workers and the public were evaluated using RADTRAN computational analysis code in case of the domestic on-road transportation of new package and transportation containers under development. The results were compared with the domestic annual dose limit. In addition, the sensitivity of the expected exposure dose according to the change in the leakage rate of radionuclides in the waste packaging was evaluated. As a result of the evaluation, it was confirmed that the exposure dose under normal and accident condition was less than the domestic annual exposure dose limit. However, in the case of a number of loading and unloading operations, working systems should be prepared to reduce the exposure of workers.

선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로 (Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권6호
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

Recent Trend of Occupational Exposure to Ionizing Radiation in Korea, 2015-2019

  • Lim, Young Khi
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.213-217
    • /
    • 2021
  • Background: Radiation exposure can occur as a result of occupational activities utilizing sources of radiation. The average level of occupational exposure is generally similar to the global average, but some workers receive more than this. In this study, the occupational exposure data for workers in Korea to check the recent trend of radiation exposure. Materials and Methods: The data collection and analysis are carried out by two separate periods based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) survey. One is the year 2003 to 2014 for a recent survey, and the other is 2015 to 2019. All available data were collected by annual reports from radiation dose registry organizations. Results and Discussion: The annual dose over the record level to the total workers did not change much compared with the total increasing number of workers in this period. The dose to the nuclear fuel cycle field has a tendency to decrease. It resulted from the efforts of radiation dose reduction with high technology introduced to this area. Also, it is important result that the radiation dose to the workers in radiography is remarkably reduced. Conclusion: The number of radiation workers and average doses were analyzed for occupational categories in Korea. It still needs cooperative efforts between the dose registry organizations for the efficient dose management of Korean radiation workers.

라돈 노출 유효선량 평가를 위한 연간 평균 라돈 농도 예측모델 개발 (Development of Predictive Model for Annual Mean Radon Concentration for Assessment of Annual Effective dose of Radon Exposure)

  • 이철민;강대용;고상백;조용석;이다정;이슬비
    • 한국환경과학회지
    • /
    • 제25권8호
    • /
    • pp.1107-1114
    • /
    • 2016
  • This research, sponsored by the Korean Ministry of Environment in 2014, was the first epidemiological study in Korea that investigated the health impact assessment of radon exposure. Its purpose was to construct a model that calculated the annual mean cumulative radon exposure concentrations, so that reliable conclusions could be drawn from environment-control group research. Radon causes chronic lung cancer. Therefore, the long-term measurement of radon exposure concentration, over one year, is needed in order to develop a health impact assessment for radon. Hence, based on the seasonal correction model suggested by Pinel et al.(1995), a predictive model of annual mean radon concentration was developed using the year-long seasonal measurement data from the National Institute of Environmental Research, the Korea Institute of Nuclear Safety, the Hanyang University Outdoor Radon Concentration Observatory, and the results from a 3-month (one season) survey, which is the official test method for radon measurement designated by the Korean Ministry of Environment. In addition, a model for evaluating the effective annual dose for radon was developed, using dosimetric methods. The model took into account the predictive model for annual mean radon concentrations and the activity characteristics of the residents.

Analysis of Cosmic Radiation Exposure for Domestic Flight Crews in Korea

  • Ahn, Hee-Bok;Hwang, Junga;Kwak, Jaeyoung;Kim, Kyuwang
    • Journal of Astronomy and Space Sciences
    • /
    • 제39권2호
    • /
    • pp.51-57
    • /
    • 2022
  • Cosmic radiation exposure of the flight crews in Korea has been managed by Radiation Safety Management around Living Life Act under Nuclear Safety and Security Commission. However, the domestic flight crews are excluded from the Act because of relatively low route dose exposure compared to that of international flight crews. But we found that the accumulated total annual dose of domestic flight crews is far from negligible because of relatively long total flight time and too many flights. In this study, to suggest the necessity of management of domestic flight crews' radiation exposure, we statistically analyzed domestic flight crew's accumulative annual dose by using cosmic radiation estimation models of the Civil Aviation Research Institute (CARI)-6M, Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS), and Korean Radiation Exposure Assessment Model (KREAM) and compared with in-situ measurements of Liulin-6K LET spectrometer. As a result, the average exposure dose of domestic flight crews was found to be 0.5-0.8 mSv. We also expect that our result might provide the basis to include the domestic flight crews as radiation workers, not just international flight attendants.

High-radiation-exposure work in Korean pressurized water reactors

  • Changju Song;Tae Young Kong;Seongjun Kim;Jinho Son;Hwapyoung Kim;Jiung Kim;Jaeok Park;Hee Geun Kim;Yongkwon Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1874-1879
    • /
    • 2024
  • Owing to strict radiation safety management in Korean nuclear power plants (NPPs), most radiation workers receive very low radiation doses, even lower than the annual dose limit for the general public. However, the occupational dose distribution indicates that some Korean NPP workers receive a relatively higher dose than the average dose. This inequity in radiation exposure could be reduced by providing customized radiation protection measures, such as dose constraints, to workers receiving relatively higher doses. In this study, dose normalization was performed to identify the highest radiation exposure work in Korean pressurized water reactors (PWRs). The results show that most of the occupational exposure in Korean PWRs occurs during the planned maintenance period. Finally, the three highest radiation exposure tasks in Korean PWRs were identified: nozzle dam installation and removal, eddy current testing, and man-way opening and closing.

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석 (Analysis of Local Exposure Levels of Radiation Emitted from Soft X-ray Ionizers in LCD Manufacturing Processes)

  • 김준범;정은교;정기효
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.342-352
    • /
    • 2021
  • Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics. Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement. Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.