• Title/Summary/Keyword: Annual concentration

Search Result 661, Processing Time 0.022 seconds

Airborne Suspended Particulates Concentration and Cancer Risk Assessment of Polycyclic organic matter in Seoul (서울시 대기부유분진의 농도와 다환방향족 유기물질에 의한 발암 위해성)

  • Park, Seoung-Eun;Chung, Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.247-256
    • /
    • 1992
  • Airborne suspended particulates were collected at Shinchon by a high volume cascade impactor from Sep. 1990 to Aug. 1991. Organic matter was extracted from particulates and fractionated by liquid-liquid extraction and thin layer chromatography. Substances in the PAHs and nitroarenes'subfraction of neutral fraction were determined by capillary gas chromatography. Based on unit risk estimates by multi-stage model of benzo[a]pyrene and the results of exposure estimates, cancer risk was assessed. The annual average concentration of total suspended particulates was 201.77g/$m^3$. The percentage of fine particulates was 57.40. The concentration of total suspended particulates showed seasonal variations and was high in winter and spring. The average concentration of extractable organic matter was 8.12g/$m^3$. In all, 21 PAHs were identified and quantified. The annual concentration of fluoranthene was 2.38ng/$m^3$, and that was the highest value of all PAHs. A carcinogenic compound, benzo[a]pyrene, was at a concentration of 1.84ng/$m^3$. All the 10 nitroarenes were also identified and quantified. The major nitroarene in the Shinchon area was 2,7-dinitrofluorene. The annual concentration of 1-nitropyrene was 1.56ng/$m^3$. Concentrations of PAHs and nitroarenes were high in winter and low in summer. The life time excess risk estimates of benzo[a]pyrene was calculated as 0.96 persons/a million population in this experiment. In the rank of relative potenties, carcinogenic effects of the other PAHs were calculated as 0.004-0.108 persons/a million population.

  • PDF

A Study of Radon Concentration in First Floor and Basement and Prediction of Annual Exposure Rate in Korea (국내 실내 라돈농도와 연간 피폭선량 예측에 관한 연구)

  • Lee, Jong-Dae;Kim, Yoon-Shin;Son, Bu-Soon;Kim, Dae-Seon
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.311-317
    • /
    • 2006
  • The purpose of this study was to investigate Rn concentration and annual radiation exposure level in the basement and first floor. The Rn Cup monitors were placed in different environments such as shopping stage, office building, Apartment, Hospital, house in Seoul from Match 1996 to April 1997 and CR-39 films were collected every two months. The mean radon concentration in the basement of house($88.6\;Bq/m^3$) showed the highest level among the areas, while radon concentration on the first floor of house($50.5\;Bq/m^3$) showed the higher than other areas. The annual radiation exposure dose that person on the floor / in the basement of differential place in the seoul can be exposed during living was estimated from 24.11 to 87.64 mRem/yr. This radiation dose is significantly lower than 130mRem maximum radiation dosage from the radon nuclide prescribed by the ICRP, with respect to the overall average exposure of the working adult. this study indicated that possible radon sources on the first floor / in the basement areas are radon intrusion from soil gas, construction materials, or ground water leaking. Further study is needed to quantitatively assess major contributions of radon-222 and health effect to radon exposure.

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

Seasonal Changes of Environmental Factors and Primary Productivity in the Jido Pond Ecosystem (지도못 生態系에 있어서의 1次 生産性과 環境要因의 계절적 變化)

  • Lyu, Seung-Won;Song, Seung-Dal
    • The Korean Journal of Ecology
    • /
    • v.7 no.2
    • /
    • pp.61-66
    • /
    • 1983
  • Seasonal changes of aquatic environmental factors, phytoplankton biomass and primary productivity were investigated in the Jido pond (a phytoplankton proliferating pond) from August 1982 to October 1983. Secchi disc transparency, pH, alkalinity and inorganic nitrogen concentration ranged 24~105cm, 7.5~10.6, 50~175mgCaCO3/l 0.1~4.0mgN/l, respectively. The minimum values of transparency, alkalinity and inorganic nitrogen concentration and the maximum value of pH were obtained during the phytoplankton proliferating season. The phytoplankton biomass changed in the range of 51~1146mgchl/m3 with considerable fluctuations but maintained fairly constant in winter. Themaximum and minimum rates of monthly carbon inflow (net primary production) of the phytoplankton community attained 1190gc/m2 in August 1982 and 68g/m2 in February 1983, respectively. The annual rates of inflow and outflow from August 1982 to July 1983 were 7.384 and 7.396kgc/m2, respectively. Turnover rate of phytoplankton carbon and efficiency of radiation of the phytoplankton community varied in the ranges of 60~130%/day (annual mean, 90%/day) and 0.9~11.2% (annual mean, 6.3%), respectively.

  • PDF

The Measures of Ozone Pollution: An Analysis of Ozone Concentration Data in USA

  • Kim, Hong-J.;Lovell, Sabrina J.;O'Farrell, John;Cho, Yong-Sung
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • In this study, we analyzed how ozone pollution could be differently measured and how these different measures varied year to year and across the ten most populated cities in the United States, from 1980 to 2000. Although peak values of ozone concentration have been significantly reduced in most polluted U.S. cities for the last 20 years, the annual average values of ozone concentration have not been lowered as much as peak values. Ozone concentration data for each city shows a unique pattern of distribution, central tendency, and also there is a wide variation among different ozone measures. Two different cities with the same annual mean concentration of ozone can experience very different distributions of ozone concentration within a year. Ozone measures also show a wide margin of variability as they are estimated from different ozone monitoring sites within each city. Ozone pollution statistics can be largely varied depending on the choice of measures, monitoring sites, and averaging time period. EPA's new ozone standard of 0.08 ppm averaged over an eight-hour appears to be more stringent than the current maximum ozone standard of 0.12 ppm averaged over one hour.

Air Quality Monitoring in Daejeon City with Long-Term NO2 and SO2 Passive Diffusive Samplers (장기 NO2 및 SO2 Passive Diffusive Sampler(PDS)를 이용한 대전시 대기질 모니터링)

  • Yim, Bong-Been;Kim, Sun-Tae;Jung, Jae-Ho;Lee, Bum-Jin
    • Journal of Environmental Science International
    • /
    • v.16 no.2
    • /
    • pp.187-195
    • /
    • 2007
  • Long-term passive diffusive samplers(PDS) have been used to measure $NO_2\;and\;SO_2$ concentrations at 21 sampling sites in Daejeon, Korea during the period of January 2000 - December 2002. The spatial distributions of annual $NO_2\;and\;SO_2$ concentrations were mapped. Average annual $NO_2$ concentration over the sampling period was $28.5{\pm}12.5\;ppb$, ranging from 1.2 to 81.7 ppb. Average annual $SO_2$ concentration over the sampling period was $7.7{\pm}4.8\;ppb$, ranging from 0.6 to 26.8 ppb. On average, $NO_2$ concentration was approximately 5.8%(1.6 ppb) larger in 2002. $SO_2$ concentration was decreased by 13%(1.1 ppb) during the sampling period. The seasonal variation of $NO_2\;and\;SO_2$ concentration was observed with a tendency to be higher in fall and winter. $NO_2\;and\;SO_2$, concentrations measured at different site types(patterns of land use) show significant difference. The observed difference in concentration was associated with difference in emissions of $NO_2$ from motor vehicles and $SO_2$ by non-traffic fuel consumption for heating.

Analysis of Air Pollution Concentrations at Cheju Baseline Measurement Station (제주도 고산 측정소에서의 대기오염 배경농도 측정 및 분석)

  • 박경윤;이호근;서명석;장광미;강창희;허철구;김영준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.252-259
    • /
    • 1994
  • A ground station has been established at Kosan, Cheju Island, since January of 1992 for the monitoring of background air Pollutant levels in Korea. Anthropogenic pollutant sources and meteorological conditions of Kosan were surveyed. Concentrations of SO$_2$, NO, NO$_{y}$ and $O_3$, were measured and analyzed for the period of February through December, 1992. The annual means of NO and SO$_2$, levels were very low in comparison to other urban's levels and similiar to other country's background levels. The annual mean of $O_3$, level was higher than urban's but comparable to other coastal region's. The NO concentration showed a distinct seasonal and diurnal variations. Summer peak was detected in the monthly means of NO and smooth peak around noon was found in the annual means of hourly data. Diurnal variation of the SO$_2$ concentration was barely detected but a slice increase in winter was detected. The $O_3$, concentration data, however, showed seasonal and diurnal variations similar to the urban's.an's.

  • PDF

Characteristics of Concentration Distribution of Coastal Urban Air Pollutants (연안 도시 대기오염 물질의 농도분포 특성)

  • 박종길;석경하;김지형;차주완
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1243-1252
    • /
    • 2002
  • This paper aims to find the characteristics of concentration distribution of coastal urban air pollutants. For this purpose, It was used the daily meteorological data and the hourly concentration data for $O_3$and NO$_2$ in Busan metropolitan city from 1994 to 1996. It was investigated the annual and monthly distribution of ozone and nitrogen dioxide concentration at each site in Busan, and also investigated the characteristics of concentration change of air pollutants with time under the sea breeze. As a results, the concentration of nitrogen dioxide and ozone tend to be increased every year and nitrogen dioxide concentration is higher than ozone concentration at all sites in Busan. The concentration of ozone is high in summer season and low in winter season, but the concentration of nitrogen dioxide have a reversed trend. The monthly peak concentration of ozone occurred in April and September, while the monthly minimum concentration of nitrogen dioxide occurred in August. Their trend were identified by sites near the coastline than sites stands apart from the coastline. The sea breeze occurred annual mean 81 day in Busan from 1994 to 1996. The main wind direction of sea breeze was classified into southwesterly and southeasterly. In case of southwesterly, It was pronounced the south wind and southwest wind. In case of southeasterly, the occurrence frequency of east wind was high. Especially, the concentrations of urban air pollutants, such as ozone and nitrogen dioxide, were high on time which the sea breeze flow, and the areas that ozone concentration was high moved from outside part to central part of city with time. In costal urban such as Busan, the wind direction of sea breeze is influenced the change of ozone and nitrogen dioxide concentration on time which the sea breeze flow at each site and also influenced the change of air pollutants concentration of sites on the pathway of sea breeze.

The distribution and annual variation of detergent-degrading bacteria in the Han river downstream (서울시역 한강수계의 합성세제 분해세균의 분포)

  • 배경숙;이혜주;하영칠;홍순우
    • Korean Journal of Microbiology
    • /
    • v.20 no.3
    • /
    • pp.113-118
    • /
    • 1982
  • The distribution and annual variation of detergent-degrading bacteria which were isolated from the Han River downstream running through the center of Seoul area were studied. The concentration of dissolved detergent was the lowest, 2.16 ppm at site 1 and it was gradually increased to downstream, the highest, 2.67 ppm at site 4. Population density of detergent degrading bacteria was about $10^2{\sim}10^3 cells/ml$. The density of LAS degrading bacteria was 1.1 - 1.8 times larger than that of SDBS-degrading bacteria. In annual variation the lowest density was appeared on January and the highest on July. In seasonal distribution of LAS-degrading bacteria, annual dominant group was genus Pseudomonas. There were few except genus Pseudomonas in winter and the subdomiannt group in spring and summer was genus Aeromonas and Enterobacteriaceae respectively. In autumn genus Pseudomonas, Aeromonas and Enterobacteriaceae were equally distributed. In SDBS-degrading bacteria, the annual dominant group was also genus Pseudomonas.

  • PDF

Runoff Characteristics of Pollutant Loads of the Lower Han River (한강하류 오염부하의 유출특성)

  • Yoo, Ho-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.479-486
    • /
    • 2012
  • Runoff characteristics of pollutant loads of the lower Han River was studied before full implementation of Total Pollution Load Management System(TPLMS). Magnitude of macroscopic(annual) fluctuation was in the order of Namhan River > Han River > Bukhan River, gross weight TP > gross weight TN > gross weight BOD, gross weight deviation > concentration deviation. Flux variation was higher than that of concentration. Microscopic(weekly) fluctuation showed similar pattern to macroscopic scale. TP showed the highest deviation resulting in the lowest reliability. 60% of annual flux passed during summer 3months resulting in 43-46% pass of gross weight at the lower Han River. Strong correlation was found between flux and gross weight especially in gross weight TN. Gross weight pollution increased as high as 400% while passing Seoul area due to the concentration. The deviation from moving average increased during summer season in the gross weight TP and BOD. Seasonal tendency was confirmed especially in gross weight TN and TP using autocorrelation function.