• Title/Summary/Keyword: Annual Failure Rate

Search Result 34, Processing Time 0.03 seconds

The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment (PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Lee, Min-Woo;Kwon, Soon-Mu
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.301-308
    • /
    • 2014
  • The mass storage of data and the importance of storage capacity lately has emerged. In this paper, we suggest the new method which estimate life cycle from acceleration life test about 2.5 inch hard disk driver as mass storage, which minimize the difference between real market annual failure rate and estimated failure rate. we obtain market transfer capacity per hours from returned 2.5inch hard disk drives about 309 numbers and accelerating transfer capacity per hours from acceleration life test. we calculate acceleration factor about duty cycle and estimate annual failure rate from failure rate and acceleration factors: temperature acceleration factor, duty cycle acceleration factor, the transfer capacity per hour represent the 93.4 % of user is 5.8 GB/hour, the transfer capacity per hour from acceleration life test is 81.4 GB/hour. the acceleration factor of duty cycle is 14.1. annual failure rate is stabilized at market one year after, annual failure rate is between 0.3 and 0.378. estimated annual failure rate is 0.4, so it is matched at 75~94 % between estimate annual failure rate and market annual failure rate. This study influence the estimate method of annual failure rate by the result of acceleration life cycle of manufacture.

The Effect of Usage and Storing Conditions on John Deere 3140 Tractor Failures in Khouzestan Province, Iran

  • Afsharnia, Fatemeh;Marzban, Afshin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.2
    • /
    • pp.75-79
    • /
    • 2017
  • The use of tractors to carry out agricultural work has played an important role in mechanizing the agricultural sector. A repairable mechanical system (such as an agricultural tractor) is subject to deterioration or failure. In this study, a regression model was used to predict the failure rate of a John Deere 3140 tractor. The machine failure pattern was carefully studied, and key factors affecting the failure rate were identified in five regions of the Khouzestan province. Through a questionnaire, data was obtained from farm records. This data was grouped into six sub-groups, according to the annual use hours (AUH) and the manner in which the tractors were stored. Results showed that AUH and storage policies affected failure rate slightly. With an increase in the age of the tractors, the failure rate in the tractors used for 1050-2000 hours annually and stored outdoors was higher than those used for 200-1000 hours annually and stored in sheds. When the tractors were of the same age, the slope of the curve in the 200-1000 annual use hours increased gradually and then rapidly, but failure rate in the 1050-2000 annual use hours was high from the beginning, and subsequent increase in this value was almost uniform. As a result, it can be said that with an increase in the annual use hours, the failure and breakdown rate in John Deere 3140 tractors rapidly increases, but maintenance conditions only slightly affect the failure and breakdown rate.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

A Study on the Failure Characteristics about Metropolitan Pipelines in Korea (국내(國內) 대도시(大都市) 수도관(水道管)의 파손특성(破損特性)에 관한 연구(硏究))

  • Lee, Hyun-Dong;An, Youn-Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.1
    • /
    • pp.96-111
    • /
    • 1996
  • The failure of water pipelines is progressed by several compound factors and the collection and analysis of data about pipeline failure are inevitable for effective pipeline rehabilitation. Data analysis of pipeline failure was already performed in USA and Europe. Based on such phenomena, failure characteristics about metropolitan pipelines in Korea were analyzed: The conclusions of this study are as followings. 1. The failure cause of pipelines can be classified into natural cause and artificial cause. Artificial cause is 32% of total causes, so artificial failure as several constructions happens frequently in Korea. Although the failure by old pipe is greatest of any other causes m classtfied cause, failure cause is not classified in detail now. 2. The damaged part of pipelines is affected by cities, distribution system inventory, bedding conditions, and so on. In this study, the failure of pipeline body(67%) is greater than the failure of pipeline joint(33%) in natural failure. 3. In regard to pipe materials, failure rate of DCIP(0.8456), PEP(0.7288), and GSP(0.6643) is greater than that of CIP(0.3985) and CWSP(0.2348). 4. Usually, faIlure rate is increased in proportion to diameter of pipeline. In this study, CIP, DCIP, and CWSP have clear trends. But the trends of PEP is reverse, the case of GSP, HP is obscure due to data shortage. 5. There are no direct relationships between burial age and failure rate of pipelines. 6. Annual breaks and winter(Nov.~Feb.) breaks of pipelines are investigated. As a result, WInter breaks to annual breaks of CIP is 51.3%(Seoul), 51.1%(Taegu),38.7%(Pusan). This phenomena have direct correlation with average winter temp. of cities.

  • PDF

Long-term Experience with the Bjork-Shiley Monostrut Valve (Bjork-Shiley monostrut 판막의 임상 치험)

  • 김영태
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1337-1345
    • /
    • 1992
  • One hundred and fourty-one Bjork-Shiley Monostrut valves were implanted in 105 consecutive patients from November 1983 to February 1990. There were 61 male and 44 female patients with a mean age of 33.6 years at the surgery. The cummurative follow-up was 370.3 patient-years with a mean of 44.0 months per patient. The operative mortality rate was 3.8%, and the linealized late mortality was 1.18%/patient-year. The incidence of major complications were 4.59%/patient-year, and the actuarial rate of freedom from valve-related morbidity was 80.2$\pm$4.4% at 7 years. The 7-year survival rate was 90.5$\pm$4.1%, and the actuarial rate of freedom from thromboembolism at 7 years was 93.3$\pm$2.3%. The linealized annual rates of complication were ; structural valve failure 0.27% /patient-year, non-structural valve failure 0.54% /patient-year, thromboembolism 1.62% /patient-year; bleeding 1.62% /patient-year; endocarditis 0.54% /patient-year. On the basis of our experience, we judged the Bjork-Shiley Monostrut valve reliable, with similar incidence of valve-related morbidity of other mechanical prosthetic valves.

  • PDF

Clinical evaluation of the Hancock porcine xenograft valve (Hancock 판막의 임상적 평가)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.281-288
    • /
    • 1987
  • A total and consecutive 163 patients underwent cardiac valve replacement using the Hancock porcine xenograft cardiac valves from 1 976 to 1984. Of 198 substitute valves, 177 were the Hancock valves. One hundred twenty-nine patients[79.1%] had single valve replacement: MVR 118, AVR 8 and TVR 3; 33[20.3%] had double valve replacement: MVR+AVR 27 and MVR+TVR 6; and a single case had triple valve replacement. Other surgical procedures were added in 34 patients. The operative mortality rate within 30 days of surgery was 6.1%, and it was, however, 4.2%, with single MVR. Late mortality rate was 6.7% or 1.95%/patient-year of a linealized mortality rate. Early survivors of 153 patients were followed up for a total of 565.1 patient-years [a mean of 44.3*27.1 months]. The linealized annual complication rates were: 1.95% emboli/patient-year, 0.89% bleeding/patient-year 1.24% endocarditis/patient-year, and 4.25% overall failure/patient-year. Primary tissue failure occurred at a rate of 1.59%/patient-year. The actuarial survival rates including operative mortality were 87.0*4.1% and 77.3*6.6% at 5 and 11 years after surgery respectively. The probability of freedom from thromboembolic complication of 89.2*3.4% at 5 years after surgery lasted unchanged upto 11 years. The probability of freedom from overall valve failure was 81.3*4.5% at postoperative 5 years, and it dropped down to 26.2*19.4% at 11 years, although the latter was statistically insignificant because of a small number of patients entering into the years approaching the follow-up end. However, the probability of freedom from the primary tissue failure was 81.3*10.6% at postoperative 9 years, which coincides closely with the speculated rate of tissue degeneration of about 20% in 10 years. These clinical results confirm the low thrombogenicity of the Hancock porcine valve and the reasonable failure rate of tissue degeneration.

  • PDF

Reliability Analysis Procedures for Repairable Systems and Related Case Studies (수리 가능 시스템의 신뢰성 분석 절차 및 사례 연구)

  • Lee, Sung-Hwan;Yum, Bong-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.51-59
    • /
    • 2006
  • The purpose of this paper is to present reliability analysis procedures for repairable systems and apply the procedures for assessing the reliabilities of two subsystems of a specific group of military equipment based on field failure data. The mean cumulative function, M(t), the average repair rate, ARR(t), and analytic test methods are used to determine whether a failure process follows a renewal or non-renewal process. For subsystem A, the failure process turns out to follow a homogeneous Poisson process, and subsequently, its mean time between failures, availability, and the necessary number of spares are estimated. For subsystem B, the corresponding M(t) plot shows an increasing trend, indicating that its failure process follows a non-renewal process. Therefore, its M(t) is modeled as a power function of t, and a preventive maintenance policy is proposed based on the annual mean repair cost.

Distribution System Reliability Evaluation Considering Protective System (보호시스템을 고려한 배전계통의 신뢰도 평가)

  • Kim, S.H.;Jwa, C.K.;Choi, B.Y.;Choi, S.H.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1003-1005
    • /
    • 1997
  • To evaluate the quality of a system or its ability to perform a required function, it is necessary to quantify the reliability of that system. The reliability techniques are based on the concept of expected failure rate and average-outage-duration method. For each load point, the expected failure rate, average outage duration and average annual outage time are evaluated. This paper deals with the reliability evaluation for distribution system including the protection relay system. In evaluating the reliability, it suggests a method for the analysis of protective system reliability, that provides a probabilistic measure of the success of the protective apparatus to perform its intended function. The analysis shows the dependency of success on the reliability of many components, and the way this reliability may be enhanced by redundancy.

  • PDF

Level Ice Loads on Various Arctic Structures (극지대 구조물 형태에 따른 빙력고찰)

  • 조철희
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.20-27
    • /
    • 1996
  • Ice loads can determined by many factors like ice properies and dimension, velocity and type of structures. The magnitude of ice load varies with the failure mode which can be predicted by failure maps if the aspect ratio and strain rate are known. To reduce the ice force, various types of structure have been investigated and it is now known that the identor shape plays an important role in reducing ice load on Arctic offshoe structures. The conical and wedge structures are good applied examples in the Arctic region. In this study, ice forces on single wedge indentors are investigated for crushing failure mode. The ice loads on wedged indentors are compared with those on cylindrical structures. Also the concept of "ice annual"is introduced to verify the ice loads to multi and single wedge structures.tructures.

  • PDF

Durability of the Low Profile Ionescu-Shiley Valve in Aortic Position (이오네스큐 단고형 대동맥판의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1041-1047
    • /
    • 1992
  • The consecutive 35 patients underwent isolated aortic valve replacement with the low-profile model of the Ionescu-Shiley pericardial xenograft valve from 1984 to 1991. Operative mortality was 2.9%, and early survivors were followed up for a total 136.1 patient-years[Mean$\pm$SD, 4.00$\pm$2.14 years]. The linearized late mortality was 2.204% /pt-yr. Three patients required rereplacement of the valve with overall valve failure rate of 2.204% /pt-yr: two for endocarditis and one for paravalvular leak. There was no case of primary tissue failure. The linearized annual rates of complication were: thromboembolism 0.735% /pt-yr, bleeding 0.735%pt-yr, and endocarditis 2.204% /pt-yr. The actuarial survival at 8 years of follow-up was 90.4$\pm$5.3%, and the probabilities of freedom from thromboembolism and from rereplacement were 95.6$\pm$4.4% and 88.2$\pm$6.7% at 8 years respectively. Although the low profile Ionescu-Shiley pericardial valve provided favorable clinical performance comparable with the standard model up to 8 years, it needs prolonged follow-up to assess the pattern of its durability.

  • PDF