• Title/Summary/Keyword: Annoying Noise

검색결과 53건 처리시간 0.028초

Certification of Noise in Medium Speed Diesel Engine Test Shop (중형 엔진 시운전장의 소음 원인 규명)

  • Cho, S.Y.;Oh, K.T.;Kim, H.W.;Ha, J.S.;Kim, K.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1693-1698
    • /
    • 2000
  • In operating test of medium speed diesel engine, the large noise over 110dBA would be occurred, and silencer should be needed to prevent the transmission of noise through exhaust duct. A near neighborhood of medium speed engine test shop, outbreak of low frequency noise was reported. From the result of noise measurement, it was found that the coupling of engine noise and air column between workshops was main cause of annoying low frequency noise. From this study, 3 ways of reformation methods were proposed; insertion of plenum chamber, placement of baffles, and alteration of direction of exhaust. As a result of these modification, low frequency noise was cancelled out.

  • PDF

A Study on the Noise Reduction of Axial Flow Fan (축류형 팬의 저소음화에 관한 연구)

  • Oh, J.E.;Yi, S.J.;Lee, S.H.;Lee, D.I.;Kim, C.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제7권1호
    • /
    • pp.142-149
    • /
    • 1995
  • Axial fans are very useful cooling devices being widely used in many electric and industrial machinery. However those are often accompanying annoying noise. Many efforts have been devoted in order to reduce the fan noise. In this study, the procedure was devided into two major parts in considering effects of design parameters of axial fan concerned with noise ; the fan theory and the Fukano's fan noise study. By using the fan theory we defined stagger angle, camber angle, blade inlet and outlet angle for studying low noise fan. Then the effects of such angles on the flow rate and static pressure were investigated. By using the Fukano's fan noise theory, the relations of the chord length, the rotational speed and the number of blades vs. fan noise are investigated.

  • PDF

Study on the annoyance response of subway station noise using jury evaluation test (청감실험을 통한 도시철도 승강장 소음의 성가심 반응에 대한 연구)

  • Kim, Dong-Jun;Kim, Deuk-Sung;Son, Jin-Hee;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.670-677
    • /
    • 2009
  • The purpose of this study is to reveal the quantitative dose-response relationship between the noise emitted in the platform of subway station and the public response. The noise measured in the platform of subway station was used for a jury test. In order to find the factors which influence annoyance response due to the platform noise, jurors were examined for the difference of the annoying response, interrelation of sound quality parameter and annoyance response. The platform noise level was 77.2$\sim$83.9 dBA and the most of passengers at the platform were highly annoyed. And screen door contributes to annoyance reduction of platform noise. The results from analyzing sound quality parameters shows that loudness and annoyance response have a high correlation coefficient.

  • PDF

Improvement of Interior Booming Noise in the Vehicle Using the Structural Dynamic Modification (구조물 동특성 변경을 이용한 실내 부밍 소음 개선)

  • Kim, Young-Ha;Lee, Jae-Woong;Kim, Sung-Gi
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.354-359
    • /
    • 2012
  • Improvement of structure-borne noises in the vehicle compartments has been one of the primary concerns in the development of vehicles. The booming is an annoying low frequency interior noise and vibration in vehicle. But it is difficult to reduce the structure-born booming noise in traditional method - trial and error within the shorten development schedule. So in present, the structure dynamic modification (SDM) method helpful to predict the effect of the local mass, stiffness, and damping is introduced. So in order to reduce the interior booming noise, the SDM was performed, and verified with modal test result. It was shown that the interior booming noise was reduced as predicted.

  • PDF

A Study on the Workplace Noise Environment of Office Areas in Power Plant (발전소 관리실의 작업환경 소음에 관한 연구)

  • 김병삼
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제7권4호
    • /
    • pp.35-41
    • /
    • 1998
  • The workplace noise environment is composed of three basic elements : manufacturing (in a generic sense) facilities, office areas, and the community around the facility. Work must be done by all employees , and this involves communication within a variety of locations within the facility ; areas may be extremely noisy, moderately noisy, or quiet, such as an office. At the same time, the facility should not be annoying to the community. In this paper, the workplace environmental noise of office areas in power plant are studied. Turbine generator in power plant generates the noise of 90∼95 dB(A) in the frequency range of 1 kHz, which may cause occupational hearing loss. By abatement method which are made of isolation material and distance damping effect, about 29.5 dB(A) reduction has been obtained in office areas of the Power Plant . But, the workplace environmental noise of office areas in the power plant is not suited to office's purpose.

An Experimental Study on the Selection of the Proper Vocabularies for Evaluation about the Noise Emission from Water Supply and Drain Installations in Apartment Bathroom (공동주택 욕실 급배수 설비소음 평가를 위한 적정어휘 선정에 관한 실험적 연구)

  • Song, Guk-Gon;Kim, Hang;Lee, Tai-Kang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.679-682
    • /
    • 2007
  • This study aims to select the proper vocabularies for evaluation about the noise emission from water supply and drain installations in apartment bathroom. As a result of surveying overlapping vocabularies and scores of them for each sound sources, 'annoying', 'noisy', 'dynamic' and 'strident' are main unpleasant vocabularies to the noise from water supply and drain installations in apartment bathroom. And vocabularies such as 'dynamic', 'sudden', 'loudness', 'noisy' are classified into the first factor by analysis.

  • PDF

Real Time RPWM Drive System by Carrier Frequency Modulation Technique (캐리어 주파수 변조에 의한 실시간 RPWM 구동장치)

  • Na, S.H.;Choi, C.R.;Yang, S.H.;Lim, Y.C.;Kim, K.H.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2058-2061
    • /
    • 1997
  • A main research topic in PWM inverter drive system is to reduce the generated acoustic noise. One method to reduce the acoustic noise is to cause the switching pattern to be random. This RPWM(Random Pulse Width Modulation) technique for voltage controlled inverters is a kind of good solutions for reduction of acoustic noise and suppression of vibration. This paper describes a carrier frequency modulated real-time RPWM inverter. Changing the carrier frequency randomly, the power spectrum of tile acoustic noise was spread over the wide-band area. And experimental results showed that emitted noise is much more comportable and less annoying

  • PDF

Characteristics of Interior Noise at University Reading Room and User's Consciousness on the Noise (대학 독서실에서 발생하는 소음의 특성과 사용자 의식 분석 - C 대학교의 독서실을 대상으로 -)

  • Park, Hyeon Ku;Jong, Hye-Ran;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.39-44
    • /
    • 2010
  • Reading room in the university is one of necessary facilities that university student must use. It is, therefore, very important to make reading room comfortable acoustically not only to minimize the annoyance to the users but also to provide efficiency in studying. Present study aims to investigate the current situation of reading room in terms of acoustics and moreover to find out the relationship between the indoor noise and users' satisfaction through questionnaire survey. As a result, the indoor noise level is quite higher than the 1st grade, 35 dB(A), that the Ministry of land, transport and maritime affairs suggests as certificate regulation for environment friendly building and there were lots of noise sources that can provoke users in studying or concentrating. Questionnaire survey illustrates that the sound when opening and closing door, and airborne sound from outdoor transmitted through window are most annoying, which affected users' dissatisfaction.

REDUCTION OF AUDIBLE SWITCHING NOISE IN INDUCTION MOTOR DRIVES USING RANDOM POSITION PWM

  • Na, Seok-Hwan;Wi, Seok-Oh;Lim, Young-Cheol;Yang, Seung-Hak
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.316-319
    • /
    • 1998
  • RPWM(Random Pulse Width Modulation) is a switching technique to spread the voltage and current harmonics on the wide frequency area. Using randomly changed switching frequency of the inverter, the power spectrum of the electromagnetic acoustic noise cab be spread to the wide-band area. The wide-band noise is much more comfortable and less annoying than the narrow-band one. So RPWM have been attracting an interest as an excellent method for the reduction of acoustic noise on the inverter drive system. In this paper a new RPPWM (Random Position PWM) is proposed and implemented. Each of three pulses is located randomly in each switching interval. Along with the randomization of PWM pulses, the space vector modulation is executed in the C167 microcontroller also. The experimental results show that the voltage and current harmonics were spread to wide band area and that the audible switching noise was reduced by proposed RPPWM method.

  • PDF

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • 제17권3호
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.