• Title/Summary/Keyword: Anisotropic Beam

Search Result 106, Processing Time 0.02 seconds

Structural Dynamic Analysis of Bearingless Rotor System with Cross-shaped Composite Flexbeam (십자형 복합재 유연보 장착 무베어링 로터 시스템 구조동역학 해석)

  • Kim Do-Hyung;Lim In-Gyu;Lee Myung-Kyu;Lee In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.108-111
    • /
    • 2004
  • Structural dynamic characteristics and aeroelastic stability of a small-scale bearingless rotor system have been investigated. A flexbeam is one of the most important component of bearingless hub system. It must have sufficient torsional flexibility as well as baseline stiffness in order to produce feathering motion. In the present paper, a cross-shaped composite flexbeam has been proposed for a guarantee of torsional flexibility and flapwise and lagwise bending stiffness. One dimensional elastic beam model was used for the construction of a structural model. Equivalent isotropic sectional stiffness was used in the blade model, and the flexbeam was regarded as anisotropic; which has ten independent stiffness quantities. CAMRAD II has been used for the analysis of structural dynamic characteristics of the bearingless rotor system. Rotational natural frequencies and aeroelastic stability at hovering have been investigated. Analysis result shows that the cross-shaped flexbeam has the rotational natural frequency tuning capacity.

  • PDF

A Study on Biomimetic Composite for Design of Artificial Hip Joint (인공 관절 설계를 위한 바이오미메틱 복합재료에 관한 연구)

  • 김명욱;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.234-238
    • /
    • 1999
  • This study suggests the design of the functionally gradient composite, [0/90/0/core]$_s$ cross-ply laminate, to prevent stress concentration induced from the difference of rigidity between the bone and the artificial hip joint and to reinforce the wear property of the surface and the expectation of their mechanical properties. First, the four-point bending test is done about wet bones and dry bones to know the mechanical properties of the cortical bones. In result, the wet bone shows the viscoelastic behavior and the dry bone shows the elastic behavior. Moreover, we expect the properties of the proposed gradient composites as a function of carbon fiber volume fraction in each layer to apply Halpin-Tsai equation, CLPT(classical laminate plate theory), and Bernoulli beam theory etc. and decide the thickness ratio of each lamina in order to match Young's modulus of the anisotropic cortical bone with the proposed gradient composites.

  • PDF

Passive Polarization Converter Fabricated by Controlling Optic Axis of Poled Polymer Waveguides (폴링된 폴리머 광도파로의 광축을 조절하여 제작한 수동형 편광 변환기)

  • 오민철;신상영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.166-172
    • /
    • 1995
  • A novel passive TE/TM polarization mode converter is fabricated by using poled polymer waveguides. The optic axis of the poling induced waveguide is slowly rotated by using a slowly varying structure of poling electrodes. Thus the polarization conversion is achieved as the guided mode propagates through the waveguide. The proposed device is simulated by a full vectorial beam propagation method (VBPM) for anisotropic medium. For the rotation length of 1 mm, the TE polarization of the guided mode is successfully converted to the TM polarization with negligible loss. Based on the simulation results, we fabricated the polarization converter which is tested by using 1.3 $\mu$m laser diode. TE to TM mode conversion is observed with a polarization extinction ratio higher than 30 dB, and the excess loss is less than 1 dB. The polarization conversion is relatively insensitive to wavelength since the device contains no periodic structures. These devices are easier to fabricate than others containing periodic structures.

  • PDF

An efficient high-order warping theory for laminated plates

  • Deng, Zhongmin;Huang, Chuanyue
    • Structural Engineering and Mechanics
    • /
    • v.22 no.5
    • /
    • pp.599-611
    • /
    • 2006
  • The theory with hierarchical warping functions had been used to analyze composite thin-walled structure, laminated beam and had good results. In the present paper, a series of hierarchical warping functions are developed to analyze the cylindrical bending problems of composite lamina. These warping functions which refine through-the-thickness variation of displacements were composed of basic and corrective functions by taking into account of anisotropic, material discontinues, and transverse shear and normal strain. Then the hierarchical finite element method was used to form a numerical algorithm. The distribution of the displacements, in-plane stresses, transverse shear stresses and transverse normal stress for composite laminate were analyzed with the present model. The results show that the present model has precise mechanical response compared with the first deformation transverse theory and the corrective order affects the accuracy of result.

Exchange Bias Coupling Depending on Uniaxial Deposition Field of Antiferromagnetic FeMn Layer

  • Lee, Sang-Suk;Hwang, Do-Guwn
    • Journal of Magnetics
    • /
    • v.15 no.1
    • /
    • pp.17-20
    • /
    • 2010
  • The relationship between ferromagnet anisotropic magnetization and the antiferromagnet atomic spin configuration was investigated for various angles of the uniaxial deposition magnetic field of the FeMn layer in the Corning glass/Ta(5nm)/NiFe(7nm)/FeMn(25nm)/Ta(5nm) multilayer that was prepared by the ion beam sputter deposition. The exchange bias field ($H_{ex}$) obtained from the measurement of the easy-axis MR loop decreased to 40 Oe at the deposition field angle of $45^{\circ}$, and to 0 Oe at the angle of $90^{\circ}$. When the difference between the uniaxial axis between the ferromagnet NiFe and the antiferromagnet FeMn was $90^{\circ}$, the strong antiferromagnetic dipole moment of FeMn caused the weak ferromagnetic dipole moment of NiFe to rotate in the interface.

A Study on the Determination of the Principal Coordinate System of Composite Rotor Blade having Arbitrary Cross Section (임의 단면을 갖는 복합재료 회전익의 주축계 결정에 관한 연구)

  • Yu, Yong-Seok;Choe, Myeong-Jin;O, Taek-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.981-987
    • /
    • 1997
  • Modern helicopter rotor blades with non-homogeneous cross section composed of anisotropic material rquire highly sophisticated structural analysis. Variation in cross section geometry makes this task of analysis more complicated. Since rotor blades generally are much longer than their lateral dimensions, one-dimensional models seem feasible, at least from a computational point of view. Therefore determination of the principal coordinate system is very important to remove the structural coupling for one-dimensional beam modelling. In this study, shear center, and principal direction. The method will be verified by comparing the results with confirmed experimental results.

Effect of Argon Ion Beam Incident Angle on Self-Organized Nanostructure on the Surface of Polyethylene Naphthalate Film (알곤 이온빔 입사각에 따른 Polyethylene Naphthalate 필름 표면의 자가나노구조화 분석)

  • Joe, Gyeonghwan;Yang, Junyeong;Byeon, Eun-Yeon;Park, Young-Bae;Jung, Sunghoon;Kim, Do-Geun;Lee, Seunghun
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.3
    • /
    • pp.116-123
    • /
    • 2020
  • Ion beam irradiation induces self-organization of nanostructure on the surface of polymer film. We show that the incident angle of Ar ions on polyethylene naphthalate(PEN) film changes self-organized nanostructure. PEN film was irradiated by argon ion beams with the ion incident angle of 0°, 30°, 45°, 60°, and 80°. Nanostructure was altered from dimple to ripple structure as the angle increases. The ripple structure changed to pillar structure after 60°due to that the shallow incident angle increased the ion energy transfer per depth up to 50 eV/Å, which value could induce excessive surface heating and oligomer formation reacting as a physical mask for anisotropic etching. And quantitative analysis of the nanostructures was adapted by using ABC model and fractal dimension theory.

History of the Photon Beam Dose Calculation Algorithm in Radiation Treatment Planning System

  • Kim, Dong Wook;Park, Kwangwoo;Kim, Hojin;Kim, Jinsung
    • Progress in Medical Physics
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Dose calculation algorithms play an important role in radiation therapy and are even the basis for optimizing treatment plans, an important feature in the development of complex treatment technologies such as intensity-modulated radiation therapy. We reviewed the past and current status of dose calculation algorithms used in the treatment planning system for radiation therapy. The radiation-calculating dose calculation algorithm can be broadly classified into three main groups based on the mechanisms used: (1) factor-based, (2) model-based, and (3) principle-based. Factor-based algorithms are a type of empirical dose calculation that interpolates or extrapolates the dose in some basic measurements. Model-based algorithms, represented by the pencil beam convolution, analytical anisotropic, and collapse cone convolution algorithms, use a simplified physical process by using a convolution equation that convolutes the primary photon energy fluence with a kernel. Model-based algorithms allowing side scattering when beams are transmitted to the heterogeneous media provide more precise dose calculation results than correction-based algorithms. Principle-based algorithms, represented by Monte Carlo dose calculations, simulate all real physical processes involving beam particles during transportation; therefore, dose calculations are accurate but time consuming. For approximately 70 years, through the development of dose calculation algorithms and computing technology, the accuracy of dose calculation seems close to our clinical needs. Next-generation dose calculation algorithms are expected to include biologically equivalent doses or biologically effective doses, and doctors expect to be able to use them to improve the quality of treatment in the near future.

Vibration Analysis of Symmetrically Laminated Composite Rectangular Plates (대칭 복합적층 직사각형 판의 진동해석)

  • T.Y. Chung;J.H. Chung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.3
    • /
    • pp.140-148
    • /
    • 1992
  • The free vibration problem of symmetrically laminated composite rectangular plates is formulated based on anisotropic thick plate theory including the effects of shear deformation and rotary inertia. Considering the difficulty of obtaining closed-form solutions, Rayleigh-Ritz analysis using polynomials having the property of Timoshenko beam functions as trial functions is adopted. The boundary conditions elastically restrained against rotation are accomodated as well as classical boundary conditions. From the results of numerical studies, the validity of the present method is verified. And it is also found that the adoption of thick plate theory for the vibration analysis of laminated composite plates is essential because of the relatively large shear deformation effect, and that the convergence of the Rayleigh quotient to the stationary value is less rapid in anisotropic composite plates than that in the orthotropic ones due to more complicated mode shapes of the former.

  • PDF

Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm (Analytical Anisotropic Algorithm을 사용한 폐암 치료 시 MU 검증 프로그램 적용에 관한 고찰)

  • Kim, Jong-Min;Kim, Dae-Sup;Hong, Dong-Ki;Back, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose: There was a problem with using MU verification programs for the reasons that there were errors of MU when using MU verification programs based on Pencil Beam Convolution (PBC) Algorithm with radiation treatment plans around lung using Analytical Anisotropic Algorithm (AAA). On this study, we studied the methods that can verify the calculated treatment plans using AAA. Materials and Methods: Using Eclipse treatment planning system (Version 8.9, Varian, USA), for each 57 fields of 7 cases of Lung Stereotactic Body Radiation Therapy (SBRT), we have calculated using PBC and AAA with dose calculation algorithm. By developing MU of established plans, we compared and analyzed with MU of manual calculation programs. We have analyzed relationship between errors and 4 variables such as field size, lung path distance of radiation, Tumor path distance of radiation, effective depth that can affect on errors created from PBC algorithm and AAA using commonly used programs. Results: Errors of PBC algorithm have showned $0.2{\pm}1.0%$ and errors of AAA have showned $3.5{\pm}2.8%$. Moreover, as a result of analyzing 4 variables that can affect on errors, relationship in errors between lung path distance and MU, connection coefficient 0.648 (P=0.000) has been increased and we could calculate MU correction factor that is A.E=L.P 0.00903+0.02048 and as a result of replying for manual calculation program, errors of $3.5{\pm}2.8%$ before the application has been decreased within $0.4{\pm}2.0%$. Conclusion: On this study, we have learned that errors from manual calculation program have been increased as lung path distance of radiation increases and we could verified MU of AAA with a simple method that is called MU correction factor.

  • PDF