• Title/Summary/Keyword: Anion-exchange Resin

Search Result 144, Processing Time 0.025 seconds

Improving Process Capability by 2-Way Classification (2원배치법(元配置法)을 이용한 공정능력(工程能力)의 향상(向上))

  • Gu, Bon-Cheol;Song, Seo-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.17 no.2
    • /
    • pp.64-69
    • /
    • 1989
  • This paper aims at analyzing the process capability and at determining an optimal condition by experimental designs using the 2-way classification with repitition in order to maintain lower Nacl content and to refine both of a very small quantity of fatty acid and various magnetic ions in the glycerin to use ion exchange resin treatment process. An optimal condition of each level combination in both of passing temperature of cation exchange resin($A_1$, $A_2$, $A_3$) and of anion exchange resin($B_1$, $B_2$, $B_3$) is $A_3B_3$. The process capability index is improved from 0.63 to 1.40 and is interpreted as a desirable state. This analysis of process capability by experimental designs will contribute to improving productivity and quality of products.

  • PDF

Characteristics of Heat Stable Salts Treatment Using Anion Exchange Resins in CO2 Absorption Process (음이온교환수지를 이용한 CO2 흡수 공정시 발생하는 열안정성염 처리 특성)

  • Park, Kyung-Bin;Cho, Jun-Hyoung;Jeon, Soo-Bin;Lim, You-Young;OH, Kwang-Joong
    • Clean Technology
    • /
    • v.21 no.1
    • /
    • pp.22-32
    • /
    • 2015
  • In this study, we studied the characteristics of ion exchange for treatment of HSS (heat stable salts) which cause performance reduction in CO2 gas capture amine solution using anion exchange resins. The optimum HSS removal efficiency, 96.1% was obtained when using strong base anion exchange resin SAR10 at dosage 0.05 g/mL, 316 K, pH 12 and the best resin regeneration efficiency, 78.8% was obtained using NaOH solution of 3 M at 316 K. The adsorption data were described well by the Freundlich model and the sorption intensity(n) was 2.0951 lying within the range of favorable adsorption. The adsorption selectivity coefficients were increased by increasing valences and size of ion and desorption selectivity coefficients showed a contradictory tendency to adsorption selectivity coefficients. By continuous HSS removal experiments, 13.3 BV of HSS contaminated solution was effectively treated and the optimum NaOH solution consumption was 5.2 BV to regenerate resins.

Decomposition of PVC and Ion Exchange Resin in Supercritical Water

  • Kim Jung-Sung;Lee Sang-Hwan;Park Yoon-Yul;Yasuyo Hoshikawa;Hiroshi Tomiyasu
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.919-928
    • /
    • 2005
  • This study introduces the development of new supercritical water oxidation(SCW)(multiple step oxidation) to destruct recalcitrant organic substances totally and safely by using sodium nitrate as an oxidant. This method has solved the problems of conventional SCW, such as precipitation of salt due to lowered permittivity, pressure increase following rapid rise of reaction temperature, and corrosion of reactor due to the generation of strong acid. Destruction condition and rate in the supercritical water were examined using Polyvinyl Chloride(PVC) and ion exchange resins as organic substances. The experiment was carried out at $450^{\circ}C$ for 30min, which is relatively lower than the temperature for supercritical water oxidation $(600-650^{\circ}C)$. The decomposition rates of various incombustible organic substances were very high [PVC$(87.5\%)$, Anion exchange resin$(98.6\%)$, Cationexchange resin$(98.0\%)$]. It was observed that hetero atoms existed in organic compounds and chlorine was neutralized by sodium (salt formation). However, relatively large amount of sodium nitrate (4 equivalent) was required to raise the decomposition ratio. For complete oxidation of PCB was intended, the amount of oxidizer was an important parameter.

The Preparation and its Properties of Heterogeneous Anion Exchange Membrane from Polyethylene Matrix with 4-Vinylpyridine-divinylbenzene (폴리에틸렌을 지지체로한 4-Vinylpyridine-divinylbenzene 불균질계 음이온교환막의 제조 및 그의 특성에 관한 연구)

  • Hwang, Taek-Sung;Choi, Jang-Rak
    • Korean Journal of Materials Research
    • /
    • v.8 no.11
    • /
    • pp.1061-1066
    • /
    • 1998
  • The synthesises of anion exchange resin from 4vinylpyridine-divinyIbenzene(4-VP-DVB) were intented to separate boron ion. The heterogeneous anion exchange membranes were prepared with polyethylene(PE) matrix bythe hot press method. The prepared exchange membranes were characterized by FT-IR, conductormeter and pH meter to confirm structural, mechanical and electrochemical properties. Their capacities were measured by changing floe rate and voltage. The best seperation capacity was appeared in the heterogeneous membrane which contains 50 wt % 4-VP-DVB resin within PE matrix. The heterogeneous membranes treated with acid were better than that treated with water. Results from this experiment were indicated that the optimal flow rate, voltage. and time in the seperation of boron ion were lOml/min, 18volts, and 4 hours respectively.

  • PDF

Separation of Goid, Palladium and Platinum in Chromite by Anion Exchange Chromatography for Inductively Coupled Plasma Atomic Emission Spectrometric Analysis

  • Choe, Gwang Sun;Lee, Chang Hyeon;Park, Yeong Jae;Jo, Gi Su;Kim, Won Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.801-806
    • /
    • 2001
  • A study has been carried out on the separation of gold, iridium, palladium, rhodium, ruthenium and platinum in chromite samples and their quantitative determination using inductively coupled plasma atomic emission spectrometry (ICP-AES). The dissolution condition of the minerals by fusion with sodium peroxide was optimized and chromatographic elution behaviour of the rare metals was investigated by anion exchange chromatography. Spectral interference of chromium, a matrix of the minerals, was investigated on determination of gold. Chromium interfered on determination of gold at the concentration of 500 mg/L and higher. Gold plus trace amounts of iridium, palladium, rhodium and ruthenium, which must be preconcentrated before ICP-AES was separated by anion exchange chromatography after reducing Cr(Ⅵ) to Cr(III) by H2O2. AuCl4- retained on the resin column was selectively eluted with acetone- HNO3-H2O as an eluent. In addition, iridium, palladium, rhodium and ruthenium remaining on the resin column were eluted as a group with concentrated HCl. However, platinum was eluted with concentrated HNO3. The recovery yield of gold with acetone-HNO3-H2O was 100.7 ${\pm}2.0%$, and the yields of palladium and platinum with concentrated HCl and HNO3 were 96.1 ${\pm}1.8%$ and 96.6 ${\pm}1.3%$, respectively. The contents of gold and platinum in a Mongolian chromite sample were 32.6 ${\pm}$ 2.2 ${\mu}g$/g and 1.6 $\pm$ 0.14 ${\mu}g$/g, respectively. Palladium was not detected.

Adsorption characterisctics of mixed resins for perchlorate ion (혼합수지를 이용한 과염소산 이온의 흡착 특성)

  • Park, Su-Min;Jeon, Byong-Hun;Jeong, Hyuk;Paeng, Ki-Jung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.429-436
    • /
    • 2010
  • The present research evaluates the efficiency of mixed resins between anion exchange resin and active carbon. We expected synergic effect from advantages of both adsorbents. Especially, this research focused on the removal of high cencentrated perchlorate ion from demilitarization solution. The total amount of the adsorbed perchlorate ion is increased considerably with mixed resins between mono functional anion exchange resin and granular active carbon from a single adsorbent. Results demonstated that this process not only improve the efficiency of adsorbing perchlorate, but save the time, space and cost for treating perchlotrate waste solution, because of reducing organic contaminant removing process. The interference effects from coexisting anions are not significant and can successfully applied to real demilitarization sample.

Synthesis of High Loading PONF-g-GMA Anion Exchange Fiber Containing Ion Exchange Resin and Their Adsorption Properties of Vanadium (이온교환 수지를 함유한 PONF-g-GMA High Loading 음이온교환 섬유의 합성 및 바나듐 흡착 특성)

  • Baek, Ki-Wan;Park, Seung-Wook;Nho, Young-Chang;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.315-321
    • /
    • 2007
  • Aminated PONF-9-GMA ion exchange fabrics were synthesized by radiation induced graft copolymerization. Hybrid ion exchange fabrics combined with aminated PONF-g-GMA fabrics and anionic ion exchange resin were also fabricated by hot melt adhesion method and then their adsorption properties were investigated. Ion exchange capacity of the hybrid ion exchange fabrics was higher than ion exchange fabric and was lower than bead resin. The maximum value was 4.18 meq/g. Adsorption breakthrough time for vanadium of the hybrid ion exchange fabric was 550 min, which was faster than bead resin but slower than fibrous ion exchanger. The Breakthrough time of the hybrid ion exchange fabrics gets longer with increasing pH. The initial breakthrough time occurred around 400 min with increasing vanadium concentration.

Separation and Purification for the Determination of Zirconium and Its Isotopes in PWR Spent Nuclear Fuels (PWR 사용후핵연료 중 Zr 및 Zr 동위원소 정량을 위한 분리 및 정제)

  • Kim, Jung Suk;Jeon, Young Shin;Park, Yong Joon;Lee, Chang Heon;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.421-428
    • /
    • 1998
  • A method has been studied to separate Zr from various fission products in PWR spent nuclear fuels. A solution containing metal ions in place of radioactive fission products was prepared. The Zr was separated with 5 M HCl followed by eluting metal ions such as Ce, Nd, Cs, Rb, Ba, Sr, Ru, Rh, Pd, Ag and Cd with 12 M HCl on Dowex $1{\times}8$, anion exchange resin. The recovery of Zr was more than 95%. The purification of Zr was carried out on anion exchange resin, Dowex $1{\times}8$, in 5 M HCl in order to remove Mo causing isobaric effect during mass spectrometry. The method was applied to separate Zr from a spent PWR fuel. From mass spectrometric measurement, the purified Zr portion was not showed the isobars from other elements such as Mo and Sr.

  • PDF

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension (금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량)

  • Han, Chul-Woo;In, Gyo;Choi, Jong-Moon;Kim, Sun Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.608-615
    • /
    • 2000
  • A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

  • PDF

Determination of Fission Products in Simulated Nuclear Spent Fuels by Cation.Anion Exchange Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometry (양.음이온교환 크로마토그래피와 유도결합플라스마 원자방출분광법을 이용한 모의 사용후핵연료 중 핵분열생성물 분석)

  • Choi, Kwang Soon;Sohn, Se Chul;Pyo, Hyung Yeol;Suh, Moo Yul;Kim, Do Yang;Park, Yang Soon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.446-452
    • /
    • 2000
  • The simulated nuclear spent fuel (SIMFUEL) containing the platinum group elements which will not be dissolved in a nitric acid was completely dissolved with a acid digestion bomb. The metallic elements separated in the SIMFUEL were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES). Because the peaks of metallic elements were spectrally interfered by uranium spectrum, uranium and metallic elements were separated by cation exchange resin for Mo, Pd, Rh and Ru and by anion exchange resin for Ba, Ce, La, Nd, Rh, Sr, Y and Zr, respectively. The recovery of Mo, Pd, Rh and Ru after separation by cation exchange chromatography found to be 99-103% and anion exchange separation showed 96.5-107% of recovery except Y with the simulated solution whose concentration was similar to the spent nuclear fuel. The relative standard deviation of this method showed 1.3-6.7% in the SIMFUEL whose concentrations of metallic elements were between several $10^2-10^3$ppm.

  • PDF