• Title/Summary/Keyword: Angular measurement

Search Result 340, Processing Time 0.023 seconds

LABORATORY EXPERIMENTS OF OFF-AXIS MIRROR OPTICS OF ALUMINUM FOR SPACE INFRARED MISSIONS

  • Oseki, Shinji;Oyabu, Shinki;Ishihara, Daisuke;Enya, Keigo;Haze, Kanae;Kotani, Takayuki;Kaneda, Hidehiro;Nishiyama, Miho;Abe, Lyu;Yamamuro, Tomoyasu
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.359-361
    • /
    • 2017
  • We report our research on aluminum mirror optics for future infrared astronomical satellites. For space infrared missions, cooling the whole instrument is crucial to suppress the infrared background and detector noise. In this aspect, aluminum is appropriate for cryogenic optics, because the same material can be used for the whole structure of the instrument including optical components thanks to its excellent machinability, which helps to mitigate optical misalignment at low temperatures. We have fabricated aluminum mirrors with ultra-precision machining and measured the wave front errors (WFEs) of the mirrors with a Fizeau interferometer. Based on the power spectral densities of the WFEs, we confirmed that the surface accuracy of all the mirrors satisfied the requirements for the SPICA Coronagraph Instrument. We then integrated the mirrors into an optical system, and examined the image quality of the system with an optical laser. As a result, the total WFE is estimated to be 33 nm (rms) from the Strehl ratio. This is consistent with the WFEs estimated from the measurement of the individual mirrors.

A STUDY OF THE SOFTWARE ON SCHEDULING, DIAGNOSIS, GROWTH AND TREATMENT ANALYSIS (교정환자의 관리, 진단, 성장과 치료결과 분석을 위한 software 개발에 관한 연구)

  • Yang, Won-Sik;Suhr, Cheong-Hoon;Nahm, Dong-Seok;Chang, Young-Il;Kim, Tae-Woo;Kim, Keun-Man
    • The korean journal of orthodontics
    • /
    • v.22 no.4 s.39
    • /
    • pp.755-778
    • /
    • 1992
  • It is prerequisite of orthodontists to diagnose malocclusion correctly and make treatment plans accurately for treating maloccluded patients efficiently and earning more stable and better results. Recently computers were introduced in orthodontic diagnosis steps, which enabled orthodontists to get more precise diagnosis, to make more accurate treatment planning and to provide better orthodontic cares for more patients. The authors studied on the diagnostic analysis methods which have been used frequently in Korea and made a diagnostic computer program including the horizontal and/or vertical measurement of length, degrees and proportions in lateral cephalometric radiographs, the analysis of the skeletal and soft-tissue features and the evaluation of the treatment results. We also made a scheduling program for arrangement and management of patients. 40 skeletal and 24 soft-tissue landmarks were selected in a lateral cephalometric radiographs. The available analysis methods in this program are Angular analysis, Linear analysis, Ricketts analysis, Profilogram , Steiner analysis, Tweed analysis, MacNamara analysis, Open bite analysis, Kim's diagnosis, Skeleto-dental cephalometric analysis and Height & weight analysis. We suggested that this diagnostic computer program make it possible for orthodontists to get more rapid and accurate diagnostic analysis and treatment planning and for patient to earn better and more efficient orthodontic service.

  • PDF

The kinematic analysis of the ankle joint and EMG analysis of the lower limbs muscle for the different walking speed (보행 속도 변화에 따른 발목 관절의 운동학적 분석과 하퇴 근육의 근전도 분석)

  • Moon, Gon-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.177-195
    • /
    • 2005
  • The purpose of this study was to analyze the kinematic variables of ankle joints and EMG signal of the lower limbs muscle activity for the different walking speed. The subjects were 6 males of twenties. It was classified into three different walking speed-0.75m/s, 1.25m/s, 1.75m/s. The walking performances were filmed by high speed video camera and EMG signal was gained by ME3000P8 Measurement Unit. Tibialis anterior(TA), Gastrocnemius medial head(GM), Gastrocnemius lateral head(GL), Ssoleus(SO) were selected for the dorsiflexion and plantarflexion of the ankle joint. The result of this study were as follows: 1. In the gait cycle, The time parameters for the phases were showed significant difference without the terminal stance phase and terminal swing phase for the different walking speed. 2. The angle of ankle joint was no significant difference for each time point and MDF, MPF but increasing walking speed the angle had the increasing pattern slightly. 3. The angular velocity of ankle joint was showed the significant difference for LHC, RTO, RKC, LHU, MPF and MDF point along the walking speed. 4. TA was showed about 2-3 times muscle activity at the 1.75m/s than 1.25m/s in some phases. And it was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 0.75m/s. GM was showed about 2-3 times muscle activity in the 1.75m/s than 1.25m/s, and even much muscle activity at the 0.75m/s than 1.25m/s in some phases. GL was showed increasing pattern of muscle activity specially in the initial swing phase as the walking speed increased. SO was showed about 3 times muscle activity in the 1.75m/s than 1.25m/s during the plantarflexion of ankle joint. It was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 1.25m/s.

Advances in Ultrasonic Testing of Austenitic Stainless Steel Welds

  • Moysan, J.;Ploix, M.A.;Corneloup, G.;Guy, P.;Guerjouma, R. El;Chassignole, B.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.3
    • /
    • pp.245-253
    • /
    • 2008
  • A precise description of the material is a key point to obtain reliable results when using wave propagation codes. In the case of multipass welds, the material is very difficult to describe due to its anisotropic and heterogeneous properties. Two main advances are presented in the following. The first advance is a model which describes the anisotropy resulting from the metal solidification and thus the model reproduces an anisotropy that is correlated with the grain orientation. The model is called MINA for modelling anisotropy from Notebook of Arc welding. With this kind of material model1ing a good description of the behaviour of the wave propagation is obtained, such as beam deviation or even beam division. But another advance is also necessary to have a good amplitude prediction: a good quantification of the attenuation, particularly due to grain scattering, is also required as far as attenuation exhibits a strong anisotropic behaviour too. Measurement of attenuation is difficult to achieve in anisotropic materials. An experimental approach has been based both on the decomposition of experimental beams into plane waves angular spectra and on the propagation modelling through the anisotropic material via transmission coefficients computed in generally triclinic case. Various examples of results are showed and also some prospects to continue refining numerical simulation of wave propagation.

An Estimation on Two Stroke Low Speed Diesel Engines' Shaft Fatigue Strength due to Torsional Vibrations in Time Domain (시간영역에서 과도 비틀림 진동에 의한 저속 2행정 디젤엔진의 축계 피로강도 평가)

  • Lee, Don-Chool;Kim, Sang-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.572-578
    • /
    • 2007
  • Two stroke low speed diesel engines are widely used for marine propulsion or as power plant prime mover. These engines have many merits which includes higher thermal efficiency, mobility and durability. Yet various annoying vibrations occur sometimes in ships or at the plant itself. Of these vibrations, torsional vibration is very important and dictates a careful investigation during the engme's initial design stage for safe operation. With the rule and limit on torsional vibration in place, shaft strength fatigue due to torsional vibration however demands further analysis which possibly can be incorporated in the classification societies' rule and limit. In addition, the shaft's torsional vibration stresses can be calculated equivalently from accumulated fatigue cycles number due to transient torsional vibration in time domain. In this paper, authors suggest a new estimation method combined with Palmgren-Miner equation. A 6S70MC-C ($25,320ps{\times}91rpm$) engine for ship propulsion was selected as a case study. Angular velocity was measured, instead of shaft's strain, for simplified measurement and it was converted to torsional vibration stress for accumulated fatigue cycle numbers in shafting life time. Likewise, the accumulated fatigue calculation was compared with shaft fatigue strength limit. This new method can be further realized and confirmed in ship with two stroke low speed diesel engine.

CEPHALOMETRIC MEASUREMENT ACCORDING TO SKELETAL MATURITY STAGE OF THE HAND AND WRIST (수완부골성숙단계에 따른 두부방사선계칙학적 연구)

  • Choi, Hae-Woon;Kim, Jae-Hyung
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.135-148
    • /
    • 1987
  • To investigate the relationship between craniofacial growth and bone maturity of the hand wrist in normal occlusion, the author took cephalogram and handwrist radiogram of 391 students (male 192, female 199) and assessed the measurements of cephalogram according to skeletal maturity stages of the hand and wrist. In this study, four skeketal stages and 36 linear, angular measurements of the cephalometrics were selected. In hand-wrist X-ray the bones used to determine skeletal maturity were the middle phalanges of the third finger, and distal epiphysis of the radius. In cephalogram, the landmark used to measure the angle and length were N, S, Po., Ar., Go., Me., Gn., Pog., Point B, Point A, ANS, PNS, Or., U1, L1, U6, L6 etc.. The results were as follows, 1. The table of mean, standard deviation, p-value from measurements were made in each group and both sex. 2. The increased measurements according to skeletal maturity were anterior cranial bese length, posterior cranial base length, ramus height, anterior facial height, posterior facial height, L1 to mandibular plane (mm), facial plane angle. In contrast to, decreased measurements were genial angle, facial cnvexity and facial plane angle. 3. Denture pattern measurements (IMPA, FMIA, occlusal plane to Go-Gn, interincisal angle, U1 to SN plane, U1 to SN plane, U1 to facial plane, L1 to facial plane etc.) .had nothing to do with skeletal maturity. 4. Skeletal maturity had close relationship with craniofacial growth, but had little to do with tooth development.

  • PDF

A STUDY 01 OEEP ()VER81TE AND OPEN BITE BY VERTICAL CEPHALOMETRIC ANALYSIS (수직두개계측법에 의한 과개교합 및 개교에 관한 연구)

  • Jun, Youn Sic;Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.11 no.2
    • /
    • pp.109-123
    • /
    • 1981
  • The author studied and analyzed statistically 112 adults female ranging in age from 18 to 20 years with normal occlusion, 56 adults female ranging in age from 18 to 24 years with deep overbite and 53 adults female ranging in age from 18 to 28 years with open bite by vertical cephalometric analysis. The results were as follows; 1. In comparing normal occlusion with deep overbite and open bite, skeletal linear measurements were more significant than dentoalveolar linear measurements. SN-MP angle, SN-OP angle, PP-OP angle and Xi angle (ANS-Xi-Pog) were significant in anglular measurements. 2. Upper posterior facial height (SE-PNS), upper anterior alveolar height, lower posterior alveolar height, lower posterior alveolar height/lower anterior alveolar height and SN-PP angle were non significant between deep overbite and open bite. 3 The most significant items between deep overbite and open bite were lower anterior facial height (ANS-ME) and SN-MP angle. 4. Correlation coefficients of angular measurements were higher in deep overbite, while that of linear measurement total anterior facial height (N-ME) was higher in open bite. 5. In the multiple regression equation, significant variables were total anterior facial height (N-ME), lower anterior alveolar height, upper anterior alveolar height, upper posterior alveolar height, Xi angle (ANS-Xi-Pog) and ramus height (AR-Go) in deep overbite, and total anterior facial height (N-Me), lower anterior alveolar height, ramus height (AR-Go), lower posterior alveolar height, PP-MP angle and upper posterior facial height (SE-PNS) in open bite.

  • PDF

Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation (후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정)

  • 송성진;권성덕;정용무;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • The guided wave has been widely employed to characterize thin plates and layered media. The dispersion curves of phase and group velocities are essential for the quantitative application of guided waves. In the present work, a fully automated system for the measurement of backward radiation of LLW has been developed. The specimen moves in two dimensional plane as well as in angular rotation. The signals of backward radiation of LLW were measured from an elastic plate in which specific modes of Lamb wave were strongly generated. Phase velocity of the corresponding modes was determined from the incident angle. The generated Lamb waves propagated forward and backward with the leakage of energy into water. Backward radiated LLW was detected by the same transducer and its frequency components were analyzed to extract the related information to the dispersion curves. The dispersion curves of phase velocity were measured by varying the incident angle. Moving the specimen in the linear direction of LLW propagation, group velocity was determined by measuring the transit time shift in the ultrasonic waveform.

A Study for Vision-based Estimation Algorithm of Moving Target Using Aiming Unit of Unguided Rocket (무유도 로켓의 조준 장치를 이용한 영상 기반 이동 표적 정보 추정 기법 연구)

  • Song, Jin-Mo;Lee, Sang-Hoon;Do, Joo-Cheol;Park, Tai-Sun;Bae, Jong-Sue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.315-327
    • /
    • 2017
  • In this paper, we present a method for estimating of position and velocity of a moving target by using the range and the bearing measurements from multiple sensors of aiming unit. In many cases, conventional low cost gyro sensor and a portable laser range finder(LRF) degrade the accuracy of estimation. To enhance these problems, we propose two methods. The first is background image tracking and the other is principal component analysis (PCA). The background tracking is used to assist the low cost gyro censor. And the PCA is used to cope with the problems of a portable LRF. In this paper, we prove that our method is robust with respect to low-frequency, biased and noisy inputs. We also present a comparison between our method and the extended Kalman filter(EKF).

Analysis on Vehicle Tracking Error due to Radio Refraction (전파굴절에 의한 비행체 추적오차 분석)

  • Oh, Chang-Yul;Lee, Hyo-Keun;Oh, Seung-Hyeub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11A
    • /
    • pp.1078-1084
    • /
    • 2010
  • The tracking performance of a big parabola tracking antenna system for tracking and receiving of the signal from the vehicle is impacted by many factors of the internal and the external of the system. In this paper, we analyze the tracking error due to the radio refraction in the application of the tracking and positioning of the vehicle by using radio frequency. The real measurement data are used for the analysis which had been acquired by using GPS and the tracking systems of C- and S-band frequencies in NARO Space centre. To verify the correlation between the tracking errors measured and the radio refraction, we review the error factors and the accuracies of the tracking systems, and the characteristics of the refractivity. The analysis shows that there are angular errors which are due to the radio refraction and not to be neglected, compared to the accuracies of the tracking systems, in case of low elevation angle less than 10 degrees. Also, the tracking errors depend on the target altitude as well as the elevation angle for the case of the target in the troposphere. It is recommended to correct the tracking angle considering the target altitude and elevation angle for the precise target positioning.