The kinematic analysis of the ankle joint and EMG analysis of the lower limbs muscle for the different walking speed (보행 속도 변화에 따른 발목 관절의 운동학적 분석과 하퇴 근육의 근전도 분석)

  • Moon, Gon-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.177-195
    • /
    • 2005
  • The purpose of this study was to analyze the kinematic variables of ankle joints and EMG signal of the lower limbs muscle activity for the different walking speed. The subjects were 6 males of twenties. It was classified into three different walking speed-0.75m/s, 1.25m/s, 1.75m/s. The walking performances were filmed by high speed video camera and EMG signal was gained by ME3000P8 Measurement Unit. Tibialis anterior(TA), Gastrocnemius medial head(GM), Gastrocnemius lateral head(GL), Ssoleus(SO) were selected for the dorsiflexion and plantarflexion of the ankle joint. The result of this study were as follows: 1. In the gait cycle, The time parameters for the phases were showed significant difference without the terminal stance phase and terminal swing phase for the different walking speed. 2. The angle of ankle joint was no significant difference for each time point and MDF, MPF but increasing walking speed the angle had the increasing pattern slightly. 3. The angular velocity of ankle joint was showed the significant difference for LHC, RTO, RKC, LHU, MPF and MDF point along the walking speed. 4. TA was showed about 2-3 times muscle activity at the 1.75m/s than 1.25m/s in some phases. And it was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 0.75m/s. GM was showed about 2-3 times muscle activity in the 1.75m/s than 1.25m/s, and even much muscle activity at the 0.75m/s than 1.25m/s in some phases. GL was showed increasing pattern of muscle activity specially in the initial swing phase as the walking speed increased. SO was showed about 3 times muscle activity in the 1.75m/s than 1.25m/s during the plantarflexion of ankle joint. It was showed the similar muscle activity between the 0.75m/s and 1.25m/s but, showed a little much muscle activity in the 1.25m/s.

The Effect of Wear ing Spandex Wear with Compression Band on Biomechanical Parameters during a Golf Drive Swing (골프 드라이브 스윙 시 압축 밴드를 적용한 기능성 의류가 신체의 운동역학적 변인에 미치는 영향)

  • Chae, Woen-Sik;Kang, Nyeon-Ju
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.345-352
    • /
    • 2011
  • The purpose of this study was to determine how spandex wear with compressive band affects biomechanical parameters during a golf swing. Nine male golf players, each with at least 6 years golf experienc(handy 4.5${\pm}$5.4), were recruited as the participants. Eight pairs of surface electrodes were attached to the left and right side of the body to monitor the pectoralis major(PM), external abdominal oblique(AO), erector spinae(ES), and vastus lateralis(VL). This study showed that the angular velocity of the club in EG were increased during the down swing phase but X-Factor and X-factor Stretch were reduced. Average and maximum nEMG (normalized EMG) values of the left AO(external abdominal oblique) were less in EG(experimental group) compared with CG(control group) during the back swing, whereas those of left PM(pectoralis major) in EG were greater than CG. It is more likely that EG performed effectively golf swing without excess muscle activity. Thus, the spandex wear with compressive band played an important role in improving swing performance with injury prevention. This has led to suggestions of the need for further kinetic and kinematic analyses to evaluate its function.

Comparison to Cone Models for Halo Coronal Mass Ejections

  • Na, Hyeon-Ock;Moon, Yong-Jae
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.28.3-28.3
    • /
    • 2011
  • Halo coronal mass ejections (HCMEs) are mainly responsible for the most severe geomagnetic storms. To minimize the projection effect of the HCMEs observed by coronagraphs, several cone models have been suggested. These models allow us to determine the geometrical and kinematic parameters of HCMEs : radial speed, source location, angular width, and the angle between the central axis of the cone and the plane of the sky. In this study, we compare these parameters form two representative cone models (the ice-cream cone model and the asymmetric cone model) using well-observed HCMEs from 2001 to 2002. And we obtain the root mean square error (rms error) between observed projection speeds and calculated projection speeds for both cone models. It is found that the average rms speed error (89 km/s) of the asymmetric cone model is a little smaller than that (107 km/s) of the ice-cream cone models, implying that the radial speeds from both models are reasonably estimated. We also find that the radial speeds obtained from two models are similar to each other with the correlation coefficient of about 0.8.

  • PDF

A Comparative Analysis of the Finger Pressure and Kinematic Variables in the Forehand Hairpin Net Shot According to Proficiency (배드민턴 포핸드 헤어핀 동작 시 숙련 정도에 따른 손가락 압력 및 운동학적 변인 비교 분석)

  • Lee, Haeng-Seob;Chae, Woen-Sik;Jung, Jea-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.4
    • /
    • pp.387-394
    • /
    • 2012
  • The purpose of this study was to compare and analyze the finger pressure and kinematic variables in the forehand hairpin net shot between skilled elite players and less skilled recreational players. Eight elite players(age: $18.1{\pm}0.8yrs$, height: $176.8{\pm}1.5cm$, weight: $640.9{\pm}48.6N$) with minimum of 6 years of experience and eight recreational players(age: $27.9{\pm}1.6yrs$, height: $177.1{\pm}6.1cm$, weight: $820.5{\pm}62.8N$) with less than one year experience were recruited in this study. For each trial being analyzed, four critical instants were identified from the video recordings: Right heel contact1 (E1), Right toe-off (E2), Right heel contact2 (E3), and Shuttlecock Impact (E4). Each hairpin net shot was broken into consecutive phases: E1~E2 (Right Landing Phase: RLP), E2~E3 (Sliding Step Phase: SSP), and E3~E4 (Impact Phase: IP). Temporal parameters, shuttlecock speed, linear and angular kinematics of body segments, and finger pressures were computed for this study. The results showed that The finger pressure of the ring finger and the middle finger for the skilled group during an impact had significantly greater than those of unskilled group. It is possible that all fingers were not used in the same manner when the racket was gripped in forehand hairpin. The result also suggested that the ring finger and the middle finger pushed the racket from top to bottom while having the mid-phalanx and proximal phalanx of index finger as an axis.

New Portable System for Measuring the Spasticity of Injury in Central Nervous System (중추신경계 손상에 의한 경직의 이동형 측정 시스템)

  • Song, Chul-Gyu;Seo, Jeong-Hwan;Han, Sang-Hyung;Kim, Keo-Sik;An, Yang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1180-1185
    • /
    • 2009
  • Spasticity is a velocity-dependent stretch reflex disorder of the body motor system developing after the injury of the central nervous system, in which certain muscles are continuously contracted involuntarily. Conventional methods such as the modified Ashworth scale, Spasm frequency scale, pendulum test and isokinetic dynamometer had some disadvantages: limitation in discriminating the increase of resistance, immovable and expensive device, not enough study parameters. Therefore, it is necessary to introduce clinically more useful instrument, which can produce objective data and are more convenient on spasticity measurement. Spasticity measuring methods were reviewed and a new measuring instrument was designed and introduced. The new measuring system is a portable spasticity-measurement system, which encompass various scopes of spasticity-related human signals such as electrophysiologic, kinematic and biomechanical data. Our device was designed in order to measure the joint angle, angular velocity, electromyographic signals and force. We suggest that this new system can diagnose the spasticity of the muscles, objectively.

Auto-dump Design of Postharvest Bulk Handling Machinery System for Onions

  • Park, Jongmin;Choi, Wonsik;Kim, Ghiseok;Kim, Jongsoon
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.379-385
    • /
    • 2018
  • Purpose: Postharvest handling of onions (harvesting, cleaning, grading, cooling, storing, and transport) should be performed continually to reduce costs and improve quality. The purpose of this study is to a) determine the design parameters and operating conditions of anion auto-dumping that constitutes a key component of the postharvest bulk handling machinery system, and b) to perform a performance test with the auto-dump prototype system. Methods: Kinematic analyses and computer simulations of the auto-dump mechanism were applied to analyze the operating conditions and design parameters. Results: The optimum working condition for the auto-dump was determined from kinetic analyses. In addition, the interaction between the velocity of the hydraulic cylinder and the angular velocity of the auto-dump were analyzed in order to control the bulk handling machinery system. The acting forces and optimum operating conditions of the hydraulic cylinder were determined by analyzing the forces related to the mass of inertia of the auto-dump assembly during rotation. The method of controlling the feeding rate of onions in terms of the uniformity of the stacking pattern and the control of the entire system was better than the two-stage method of controlling the rotational speed of the auto-dump. Based on the performance test with the prototype for the auto-dump, the stacking pattern and rigidity of the system were analyzed. Conclusions: These results would be of great importance in the postharvest bulk handling machinery system for onions.

The Comparative Analysis of Wearing Roller Shoes and Jogging Shoes on Kinematic Characteristics in the Lower Extremity during Walking (롤러 신발과 조깅 신발 착용 후 보행 시 하지 분절의 운동학적 특성 비교 분석)

  • Jang, Jae-Ik;Chae, Woen-Sik;Kang, Nyeon-Ju;Yoon, Chang-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.399-406
    • /
    • 2009
  • The purpose of this study was to compare the effect of wearing roller shoes and jogging shoes on kinematic characteristics in lower extremity during walking. Eight male middle school students(age: $15.0{\pm}0.0^{\circ}$ yrs, height $175.9{\pm}6.6cm$, weight: $616.3{\pm}84.9$ N) who have no musculoskeletal disorder were recruited as the subjects. Temporal parameters, step length, stride length, center of mass, velocity of CM, angle of segment, angular velocity and range of motion were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions(p < .05). The results showed that stride length and velocity of CM in wearing roller shoes were significantly less than those found in wearing jogging shoes. These indicated that walking patterns may be changed by different shoe conditions and unstable braking condition because of wheel. Angle of ankle joint at LHC1 and LHC2 in wearing roller shoes was greater than the corresponding value for wearing jogging shoes. It seems that the ankle joints are locked in an awkward fashion at the heel contact to compensate for imbalance. Otherwise, dorsi flexion was not produced at the heel contact point in wearing roller shoes.

Kinematical Analysis of Side Kick Motion in Taekwon Aerobics (태권에어로빅스 옆차기동작의 운동학적 분석)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.33-42
    • /
    • 2008
  • The purpose of this study was to analyze kinematic variables during Side kick motion in Taekwon Aerobics. The subjects of this study were the 7 skilled and 7 unskilled female college students. A QTM and an Auto Track were used to acquire raw data. The sampling rates camera was 100 Hz. The parameters were calculated and analyzed with Visual3D and SPSS 12.0. The results were as following; 1. In the elapsed time, there was no significance difference statically between a skilled and unskilled group. 2. In the cases of knee angle, there was significant difference statically at Maximum Knee Flexion2(p=0.046, F=4.925). 3. In the cases of knee angular velocity, there was significant difference statically at Maximum Knee Flexion1(p=0.031, F=5.940). 4. In the flexion/extension of hip angle, there was significant difference statically at Maximum Knee Flexion2(p=0.012, F=8.668). 5. In the abduction/adduction of hip angular velocity, there was significant difference statically at Minimum Knee Flexion (p=0.019, F=7.324). 6. In the external rotation/internal rotation of hip angular velocity, there was significant difference statically Minimum Knee Flexion(p=0.005, F=11.87).

A Kinematical Characteristic Analysis of a Iron fade-shot with a Golf Swills (아이언 페이드샷의 운동학적 특성 분석)

  • Lee, Kyung-Il;Oh, Jong-Sun;Chung, Jin-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.311-322
    • /
    • 2009
  • Using the 3-D analysis, this study winpared and analyzed the 'fade-shot swing' which is one of the golf technique. The subjects of this study were 3 male pro golfers they experimented with only a 7 iron. The purpose was to enhance their performance by producing the important kinematical parameters, finding out the features in them and providing the data to a coach and players. As a result, the position of the club head showed from the outside orbit to the inside orbit. When position of the center of mass moved backwards, the probability of the failure of the fade-shot increased. Cocking angle had an effect on easing the wrist for a smooth follow-through after the impact. It showed that the changes in the shoulder movement was made first and followed by the waist. The hip joint angular velocity achieved a smooth fade-shot motion due to the hitting delay also the velocity of the club-head was faster when uncocking was released at the time of impact.

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.