• Title/Summary/Keyword: Angle of plate

Search Result 1,125, Processing Time 0.04 seconds

A Study on Vibration Intensity of Laminated Composite Plate (복합적층판의 진동인텐시티에 관한 연구)

  • Seo, Jin;Kim, Dong-Young;Hong, Do-Kwan;Choi, Seok-Chang;An, Chan-Woo;Han, Geun-Jo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.892-895
    • /
    • 2002
  • In this study, to grasp the effect of vibration intensity fur the laminated composite plate, the two-dimension plate was shaken by a harmonic point excitation with the natural frequency using the finite element method. As the result, it shows that the vibration intensity according to the change of angle-ply is various and it flows to the direction of length rather than width in the plate. Also this paper represents those results to the vector flow.

  • PDF

An Experimental Study on the Performance of a Brazed Plate Heat Exchanger (용접식 판형 열교환기의 성능에 관한 실험적 연구)

  • 김종하;권오경;윤재호;이창식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

Experimental study on the performance of a brazed plate heat exchanger (용접식 판형 열교환기의 성능에 관한 실험적 연구)

  • Kim, Jong-Ha;Yun, Jae-Ho;Kwon, Oh-Kyung;Kim, Jong-Hun;Ryu, Hae-Sung;Lee, Chang-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.477-482
    • /
    • 2001
  • An experimental study on the performance evaluation of a brazed plate heat-exchanger with 10RT of normal cooling capacity has been carried out. In the present study, a brazed type plate heat exchanger was tested at a chevron angle $25^{\circ}$ with refrigerant R-22. Mass flux was ranged from $23\;to\;58kg/m^{2}s$ in condensation, and from $22\;to\;53kg/m^{2}s$ in evaporation. The heat transfer coefficient and pressure drop increased with the mass flux increases. The water side pressure drop increased with the cooling water flow rate and chilled water flow rate increases, while mass flux has little affect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

  • PDF

Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture (흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과)

  • Shim, Byeoung-Su;Kim, Keun-Su;Lee, Jung-Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

An Experimental Study on Heat Transfer Characteristics in Plate Heat Exchangers with R134A (R134A를 이용한 판형 열교환기의 열전달 특성에 관한 실험적 연구)

  • Hong,, S.B.;Han, D.H.;Lee, K.J.;Park, S.Y.;Chang, K.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.503-508
    • /
    • 2001
  • Experiments on the condensation and evaporation heat transfer characteristics inside plate heat exchanger with R134A are performed in this study. The test plate heat exchangers in 45o, 55o and 70o shevron angle are used. Varying the mass flux of the refrigerant and the saturation temperatures, the average heat transfer coefficients are investigated. It is shown that the heat transfer is increased with increasing shevron angle. Experiments results show that average condensation heat transfer coefficients are decreased with increasing condensation temperature but those of evaporation are increased with increasing evaporation temperature.

  • PDF

Control of Tilt Angle in the Nematic Liquid Crystal on the Homeotropic Polyimide Surface as a Function of the Baking Condition (소성 조건 변화에 따른 수직 폴리이미드 표면에서 이용한 네마틱 액정의 틸트 제어)

  • Hwang, Jeoung-Yeon;Lee, Kyung-Jun;Kim, Kang-Woo;Seo, Dae-Shik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.661-667
    • /
    • 2004
  • The control of tilt angle for nematic liquid crystal (NLC) with negative and positive dielectric anisotropy on the rubbed homeotropic polyimide (PI) using baking method by hot plate equipment was investigated. LC tilt angle decreased with increasing baking temperature and time. Especially, the low LC tilt angle of positive type NLC (Δ$\varepsilon$>0) on the rubbed homeotropic PI surface by increasing temperature and time was measured. The tilt angle of positive type NLC(Δ$\varepsilon$>0) is smaller than that of the negative type (Δ$\varepsilon$>0) on rubbed PI with increasing baking temperature and time. We consider that the tilt angle of NLC is decreased due to increasing the steric interaction between horizon component of permittivity $\varepsilon$ = of NLC and the stress of polymer side chain by high temperature. As the increase of baking temperature, we obtain that AFM (atomic force microscope) image of rubbed PI surface using Hot-plate method has formed better solid micro-groove structure than oven method.

A study on the static stability of the otter board in relation to the angle of attack (영각의 변화에 대한 전개판의 정적 안정성 연구)

  • Park, Chang-Doo;An, Heui-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.234-240
    • /
    • 2002
  • The static stability of the otter board in relation to the angle of attack ($\alpha$) was studied analytically and experimentally from the moments of tensions and hydrodynamic force acting on it. Three flat plates of 0.5, 1.0, and 1.5 aspect ratios (λ) and four cambered plates of 5, 10, 15, and 20% camber ratios (CR) with the same aspect ratio (λ=1.5) were tested in a circulating water tank for measuring the hydrodynamic forces and moments relevant to the position of hydrodynamic center. And, center-of-pressure coefficients ($C_p$) and moment coefficients ($C_M$) of each plate as a function of the angle of attack were calculated for estimating the static stability from hydrodynamic forces. The obtained results are summarized as follows ; 1. When the angle of attack for otter board is changed from equilibrium for some reason, moments depending upon tensions of warp and sweep line always act in order to have the static stability, respectively. 2. Position of center-of-pressure of each flat plate moves from leading edge to center of plate with the increase of the angle of attack. It means that the moment of hydrodynamic force acting on flat plates also increases the static stability of plate. 3. With the increase of the angle of attack for cambered plates, the positions of center of-pressure move from trailing to leading edge, and then turn toward center of plate. As the camber ratios increase, the ranges of the angle of attack of the static un stability depending on moment of hydrodynamic force become wide.

Influence of temperature on the beams behavior strengthened by bonded composite plates

  • Bouazza, Mokhtar;Antar, Kamel;Amara, Khaled;Benyoucef, Samir;Bedia, El Abbes Adda
    • Geomechanics and Engineering
    • /
    • v.18 no.5
    • /
    • pp.555-566
    • /
    • 2019
  • The purpose of this paper is to investigate the thermal effects on the behaviour reinforced-concrete beams strengthened by bonded angle-ply laminated composites laminates plate $[{\pm}{\theta}n/90m]_S$. Effects of number of $90^{\circ}$ layers and number of ${\pm}{\theta}$ layers on the distributions of interfacial stress in concrete beams reinforced with composite plates have also been studied. The present results represent a simple theoretical model to estimate shear and normal stresses. The effects the temperature, mechanical properties of the fibre orientation angle of the outer layers, the number of cross-ply layers, plate length of the strengthened beam region and adhesive layer thickness on the interfacial shear and normal stresses are investigated and discussed.

A Novel ECB cell using bend structure for Nematic Liquid Crystal on Rubbed Polyimide Surface

  • Hwang, J.Y.;Kim, K.W.;Seo, D.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1137-1141
    • /
    • 2004
  • In this paper, we have improved a novel ECB mode using bend structure with high tilt angle in the unique condition by Hot plate equipment. The new control of tilt angle for nematic liquid crystal (NLC) with negative and positive dielectric anisotropy on the rubbed homeotropic polyimide (PI) using baking method by Hot plate equipment was investigated. LC tilt angle decreased with increasing baking temperature and time. We suggest that the development of the novel ECB cell using control of tilt angle on the homeotropic surface is a promising technique for the achievement of fast response time and high contrast ratio.

  • PDF

Flutter performance of central-slotted plate at large angles of attack

  • Tang, Haojun;Li, Yongle;Chen, Xinzhong;Shum, K.M.;Liao, Haili
    • Wind and Structures
    • /
    • v.24 no.5
    • /
    • pp.447-464
    • /
    • 2017
  • The flutter instability is one of the most important themes need to be carefully investigated in the design of long-span bridges. This study takes the central-slotted ideal thin flat plate as an object, and examines the characteristics of unsteady surface pressures of stationary and vibrating cross sections based on computational fluid dynamics (CFD) simulations. The flutter derivatives are extracted from the surface pressure distribution and the critical flutter wind speed of a long span suspension bridge is then calculated. The influences of angle of attack and the slot ratio on the flutter performance of central-slotted plate are investigated. The results show that the critical flutter wind speed reduces with increase in angle of attack. At lower angles of attack where the plate shows the characteristics of a streamlined cross-section, the existence of central slot can improve the critical flutter wind speed. On the other hand, at larger angles of attack, where the plate becomes a bluff body, the existence of central slot further reduces the flutter performance.