• 제목/요약/키워드: Angle measuring device

검색결과 114건 처리시간 0.029초

압전작동기 LIPCA로 구동하는 곤충 모방 날갯짓 기구 (Insect-mimicking Flapping Device Actuated by a Piezoceramic Actuator LIPCA)

  • 박훈철;모 사이푸딘;윤광준;구남서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.719-722
    • /
    • 2005
  • In this paper, we present out recent progress in the LIPCA (Lightweight Piezo-Composite Actuator) application for actuation of a flapping wing device. The flapping device uses linkage system that can amplify the actuation displacement of LIPCA. The feathering mechanism is also designed and implemented such that the wing can rotate during flapping. The natural flapping-frequency of the device was about 9 Hz, where the maximum flapping angle was achieved. The flapping test under 5 Hz to 15 Hz flapping frequency was performed to investigate the flapping performance by measuring the produced lift and thrust. Maximum lift and thrust were produced when the flapping device was actuated at about the natural flapping-frequency.

  • PDF

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

  • Jin, Ming-Xu;Hong, Min-Ho;Lee, Kee-Joon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.125-130
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS. In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of $0^{\circ}$. The device was rotated to $10^{\circ}$ in $1^{\circ}$ increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS. From $1^{\circ}$ to $10^{\circ}$, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at $0^{\circ}$. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION. Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from $1^{\circ}$ to $10^{\circ}$ during frontal photography does not affect these ratios.

자세 교정훈련을 위한 체위 변환 감지 센서 디바이스의 개발 (Development of body position sensor device for posture correction training)

  • 최정현;박준호;서재용;김수찬
    • 융합신호처리학회논문지
    • /
    • 제21권2호
    • /
    • pp.80-85
    • /
    • 2020
  • 최근 학생 및 사무직 종사자에게서 근골격계 질환의 발병률이 증가하고 있으며, 바른 자세의 유지 및 교정 훈련의 필요성이 요구되고 있으나, 관련 연구는 부족한 현실이다. 기존 연구에서는 의자 방석부분에 멤브레인 센서 또는 압력센서를 배치하여 무게의 편중을 보거나, 사용자를 구속하는 센서를 부착하여 체위 변환을 측정하였다. 본 연구에서는 착용편의성을 고려한 체위 변환 감지 센서 디바이스를 개발하였으며, 측정한 각도를 분석앱을 통해 확인하였다. 앉은 자세에서 체위 변환을 측정하기 위하여 경추 및 척추에 IMU 센서로 구성된 센서 디바이스를 부착한다. 두 개의 센서에서 측정되는 체위의 변화값을 각도로 변환하였으며, 각도값은 실시간으로 분석앱을 통해 보여 진다. 본 연구에서는 체위 변화에 따른 실시간 변화값의 측정 가능성과, 착용편의성, 각도 측정의 경향성을 확인해 보았다. 향후 연구에서는 보다 정밀한 각도의 연산 및 동잡음의 보정을 위한 연구를 진행해야 한다.

The Effects of Screen Smart Devices on the Neck Flexion Angle

  • Lee, Jun Cheol;Kim, Kyung
    • 국제물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.1051-1055
    • /
    • 2016
  • The purpose of this study was to investigate the effect of the screen size of smart devices on the bending angle of the cervical spine. The subjects of this study were 30 healthy adults(15 men and 15 women) who used smartphones and tablet PC(personal computer). The changes in the bending angle of the upper and lower cervical spine were measured in the subjects after they had used a smartphone and a tablet PC for 300 seconds each. To make sure that all subjects began in the same starting position, an angle-measuring instrument was used to set the angles of the ankle, knee, hip, and arm joints to 90 degree. The subjects were asked to keep the trunk straight. They were asked to hold a smartphone in their hand and to bend their neck so that they could look down at the screen. Once they began using the smartphone in this manner, they were free to change their posture. We used a paired t-test to compare the bending angle of the cervical spine on subjects who used smartphones and tablet PC in the long-term and short-term there production error of cervical and the significance level was cervical. The results showed that, when using a smartphone and a tablet PC for 300 seconds, there was no significant difference in the bending angle of the upper cervical spine(p>.05), although there was a significant difference in the bending angle of the lower cervical spine(p<.05).

전방머리자세 대상자의 머리-척추각과 목 운동범위, 근력, 목빗근 두께와의 상관관계 분석 (Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, and Sternocleidomastoid Thickness)

  • 강민지;박근태;한진태
    • 대한물리치료과학회지
    • /
    • 제31권1호
    • /
    • pp.88-97
    • /
    • 2024
  • Background: This study was to investigate effects of Correlation Analysis between Cervical-Vertebra Angle and Neck Range of Motion, Muscle Strength, Sternocleidomastoid Thickness of Patients with Forward Head Posture Design: Correlation Analysis. Methods: The subjects of this study were a total of 54 people in the forward head position and their ages were between 30 and 50 years old. The subjects cranio-vertebral angles, neck extension, neck flexion, neck rotation angles, neck flexor strength, neck extensor strength, sternocleidomastoid thickness were evaluated through measuring instruments. The thickness of the sternocleidomastoid muscle was measured using an imaging ultrasound diagnostic device (ultra sound, Versana Premier, GE Medical systems, China). CVA was measured by measuring the side photo of the subject was taken with a camera and evaluated.. neck joint range of motion was measured through digital inclinometer for extension, flexion, and neck rotation. neck muscle strength was measured by measuring the using a digital sthenometer. Data analysis in this study was statistically processed using SPSS version 26.0 (IBM SPSS Inc., USA). Correlation analysis was used and the statistical significance level was set at 0.05. Results: The results neck extension(r= 0.70**), neck flexion(r= 0.67**), neck rotation(r= 0.56**), neck extensor muscle strengt(r= 0.85**), neck flexor muscle strength(r= 0.66**), sternocleidomastoid thicknes(r= -0.81**) It indicates that there is a correlation. Conclusion:These results improve the Cervical-vertebra angle of patients with forward head posture should include a program to improve the thickness of the SCM. In the future, study can be used as an evidentiary material for treatment interventions to improve the Cervical-vertebra angle of patients with forward head posture.

차량 원더링 계측을 위한 사선센서 적정 설치각도 결정 (Determining the Appropriate Installation Angle of Skewed Sensor to Measure Vehicle Wandering)

  • 오주삼;장경찬;김민성;장진환
    • 한국도로학회논문집
    • /
    • 제10권3호
    • /
    • pp.79-86
    • /
    • 2008
  • 차량의 동적하중이 도로상에 작용하는 위치를 계측하기 위한 원더링 계측용 사선센서의 적정 설치각도를 제안하였다. 이를 위해서 테이프스위치 센서를 이용하여 원더링 계측용 장비를 개발하였고, 개발된 장비와 실험차량을 이용하여 평가용 자료를 수집하였다. 수집자료 분석 결과, 사선센서의 설치각도가 커질수록 원더링 수집자료의 오차가 감소하였고, 이러한 오차의 감소는 통계적으로도 의미가 있는 것으로 분석되었다. 그러나 사선센서를 $30^{\circ}$ 이상으로 설치할 경우, 탠덤축의 제원상의 이유로 인해 오류자료가 수집되는 것을 확인할 수 있었다. 따라서 본 연구에서는 국내 차량제원 등을 종합하여 원더링 계측용 사선센서의 적정 설치각도를 $20^{\circ}{\sim}25^{\circ}$로 제안하였다.

  • PDF

Cephalometrically assessing the validity of superior, middle and inferior tragus points on ala-tragus line while establishing the occlusal plane in edentulous patient

  • Chaturvedi, Saurabh;Thombare, Ram
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.58-66
    • /
    • 2013
  • PURPOSE. The purpose of this study was to decide the most appropriate point on tragus to be used as a reference point at time of marking ala tragus line while establishing occlusal plane. MATERIALS AND METHODS. The data was collected in two groups of subjects: 1) Dentulous 2) Edentulous group having sample size of 30 for each group with equal gender distribution (15 males, 15 females each). Downs analysis was used for base value. Lateral cephalographs were taken for all selected subjects. Three points were marked on tragus as Superior (S), Middle (M), and Inferior (I) and were joined with ala (A) of the nose to form ala-tragus lines. The angle formed by each line (SA plane, MA plane, IA plane) with Frankfort Horizontal (FH) plane was measured by using custom made device and modified protractor in all dentulous and edentulous subjects. Also, in dentulous subjects angle between Frankfort Horizontal plane and natural occlusal plane was measured. The measurements obtained were subjected to the following statistical tests; descriptive analysis, Student's unpaired t-test and Pearson's correlation coefficient. RESULTS. The results demonstrated, the mean angle COO (cant of occlusal plane) as $9.76^{\circ}$, inferior point on tragus had given the mean angular value of IFH [Angle between IA plane (plane formed by joining inferior point-I on tragus and ala of nose- A) and FH plane) as $10.40^{\circ}$ and $10.56^{\circ}$ in dentulous and edentulous subjects respectively which was the closest value to the angle COO and was comparable with the values of angle COO value in Downs analysis. Angulations of ala-tragus line marked from inferior point with occlusal plane in dentulous subject had given the smallest value $2.46^{\circ}$ which showed that this ala-tragus line was nearly parallel to occlusal plane. CONCLUSION. The inferior point marked on tragus is the most appropriate point for marking ala-tragus line.

Parylene-C 코팅된 의료용 SUS304 소재의 결합력 향상을 위한 플라즈마 처리 효과 (The effect of plasma treatment to improve adhesion strength of parylene-C coated medical grade SUS304)

  • 김동국;송태하;정용훈;강관수;윤덕규;김민욱;우영재;서요한;김경아;노지형
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.390-397
    • /
    • 2022
  • Parylene-C which was mainly used for industries such as electronics, machinery and semiconductors has recently been in the spotlight in the medical field due to its properties such as corrosion resistance and biocompatibility. In this study we intend to derive a plan to improve the bonding strength of Parylene-C coating with the SUS304 base material for medical use which can be applied to various medical fields such as needles, micro needles and in vitro diagnostic device sensors. Through plasma pretreatment the bonding strength between Parylene-C and metal materials was improved. It was confirmed that the coated surface was hydrophobic by measuring the contact angle and the improvement of the surface roughness of the sample manufactured through CNC machining was confirmed by measuring the surface roughness with SEM. Through the above results, it is thought that it will be effective in increasing usability and reducing pain in patients by minimizing friction when inserting medical devices and in contact with skin. In addition it can be applied to various application fields such as human implantable stents and catheters, and is expected to improve the performance and lifespan of medical parts.

Simulation Study on Measuring Pulverized Coal Concentration in Power Plant Boiler

  • Chen, Lijun;Wang, Yang;Su, Cheng
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.189-202
    • /
    • 2019
  • During thermal power coal-fired boiler operation, it is very important to detect the pulverized coal concentration in the air pipeline for the boiler combustion stability and economic security. Because the current measurement methods used by power plants are often involved with large measurement errors and unable to monitor the pulverized coal concentration in real-time, a new method is needed. In this paper, a new method based on microwave circular waveguide is presented. High Frequency Electromagnetic Simulation (HFSS) software was used to construct a simulation model for measuring pulverized coal concentration in power plant pipeline. Theoretical analysis and simulation experiments were done to find the effective microwave emission frequency, installation angle, the type of antenna probe, antenna installation distance and other important parameters. Finally, field experiment in Jilin Thermal Power Plant proved that with selected parameters, the measuring device accurately reflected the changes in the concentration of pulverized coal.