Reliability and validity of rehabilitative ultrasound images obtained using a hands-free fixed probe in measuring the muscle structures of the tibialis anterior and the gastrocnemius

  • Choi, Mun-Sang;Shin, Jang-Hoon;Park, Hye-Kang;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.194-201
    • /
    • 2019
  • Objective: This study aimed to investigate the reliability and validity of muscle thickness (MT) and pennation angle (PA) measurements of the ankle muscle, including the tibialis anterior (TA) and the medial gastrocnemius (MGCM), using a hands-free fixed probe and to compare it with the conventional linear probe. Design: Observational inter-rater reliability study. Methods: Thirty-three healthy subjects (20 male, 13 female) were included. In all subjects, ultrasound images were acquired from the TA and MGCM using a hands-free fixed probe and a conventional linear probe in random sequence by two examiners at two time-points within a 7-day interval. MT and PA were calculated on the taken images. Intra-class correlation coefficients (ICC), 95% confidence intervals, standard error of measurement and the Pearson's correlation coefficient were used to estimate reliability and validity. And also, Bland-Altman plots were generated for a visual representation of MT and PA at the TA and MGCM. Results: The ICC for all intra-rater reliability was 0.943 to 0.995 and that for all inter-rater reliability was 0.928 to 0.993, indicating excellent reliability. A significantly high correlation was observed between MT and PA at the TA and MGCM with use of the hands-free fixed probe and the conventional linear probe (r>0.938; p<0.001). Conclusions: The hands-free fixed probe provided excellent images for measurement of the MT and PA of the TA and MGCM and is a useful device for making clinical measurements of muscle structure without grasping of the probe.

Effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings (석고 모형재와 고무인상재의 젖음성이 지르코니아 코핑의 변연적합도에 미치는 영향)

  • Kim, Won-Young;Chung, In-Sung;Jeon, Byung-Wook
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.255-262
    • /
    • 2016
  • Purpose: This study examined the effect of wettability of gypsum materials and rubber impression material on the marginal fitness of zirconia copings. Methods: Three commercially available gypsum materials(Fugirock EP, Snow Rock, Tuff Rock) and three zirconia blocks(iJAM Emerald, LUXEN Smile block, ICE Zirkon transluzent) were studied. The zirconia copings were fabricated by using dental CAD/CAM system. Contact angles on the impression materials were measured with contact angle measuring device. Silicone replica method was used to measure the marginal fitness and cutting was performed on the bucco-lingual and mesio-distal sides. It were observed with a stereomicroscope at °ø40 magnification. The data were statistically analyzed with One-way ANOVA. Results: Mean values of contact angles were $58.3{\pm}0.7^{\circ}$ for Tuff Rock, $77.5{\pm}0.5^{\circ}$ for Fugirock EP and $87.8{\pm}0.5^{\circ}$ for Snow Rock and the difference between them was statistically significant(p<0.05). The smallest values of marginal fitness for the JF groups were $30.7{\pm}3.0{\mu}m$ for bucco-lingual direction, $29.3{\pm}3.0{\mu}m$ for mesio-distal direction. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). Conclusion: Tuff rock gypsum material had superior wettability to others. The mean marginal fitness of the Tuff rock gypsum material group were significantly better than other groups. Thus they can be also expected to show clinically satisfactory marginal fitness.

Development of Squat Posture Guidance System Using Kinect and Wii Balance Board

  • Oh, SeungJun;Kim, Dong Keun
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.1
    • /
    • pp.74-83
    • /
    • 2019
  • This study designs a squat posture recognition system that can provide correct squat posture guidelines. This system comprises two modules: a Kinect camera for monitoring users' body movements and a Wii Balance Board(WBB) for measuring balanced postures with legs. Squat posture recognition involves two states: "Stand" and "Squat." Further, each state is divided into two postures: correct and incorrect. The incorrect postures of the Stand and Squat states were classified into three and two different types of postures, respectively. The factors that determine whether a posture is incorrect or correct include the difference between shoulder width and ankle width, knee angle, and coordinate of center of pressure(CoP). An expert and 10 participants participated in experiments, and the three factors used to determine the posture were measured using both Kinect and WBB. The acquired data from each device show that the expert's posture is more stable than that of the subjects. This data was classified using a support vector machine (SVM) and $na{\ddot{i}}ve$ Bayes classifier. The classification results showed that the accuracy achieved using the SVM and $na{\ddot{i}}ve$ Bayes classifier was 95.61% and 81.82%, respectively. Therefore, the developed system that used Kinect and WBB could classify correct and incorrect postures with high accuracy. Unlike in other studies, we obtained the spatial coordinates using Kinect and measured the length of the body. The balance of the body was measured using CoP coordinates obtained from the WBB, and meaningful results were obtained from the measured values. Finally, the developed system can help people analyze the squat posture easily and conveniently anywhere and can help present correct squat posture guidelines. By using this system, users can easily analyze the squat posture in daily life and suggest safe and accurate postures.

A Study on the Captive Model Test of KCS in Regular Waves (KCS 선형의 규칙파 중 구속모형시험에 대한 연구)

  • Choi, Hujae;Kim, Dong Jin;Kim, Yeon Gyu;Yeo, Dong Jin;Yun, Kunhang;Lee, Gyeongjung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.296-305
    • /
    • 2022
  • In order to investigate maneuvering characteristics of KCS in waves, captive model test in regular waves was conducted. Purpose of the test is measuring maneuvering hull forces when ship is maneuvering in waves. Model test was carried out using CPMC (Computerized Planar Motion Carriage) of ocean engineering basin in KRISO (Korea Research Institute of Ships and Ocean engineering). Total 6 degrees-of-freedom motion were fixed by two points supporting captive model test device, which is specially designed for this test. This system estimates 6 degrees-of-freedom forces and moments through 12 strain gauge signals. Mapping matrix from strain gauge signals to 6 degrees-of-freedom forces and moments was derived by a well-organized calibration test. Static drift test was conducted in calm sea and in regular waves with various wave conditions. Hydrodynamic coefficients related to drift angle were extracted for each wave conditions, and the effect of waves on course stability was analyzed.

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

A Freeze-fracture Study on the Odontoblast of Dental Pulp in the Rat Incisor (흰쥐 절치치수의 Odontoblast에 관한 Freeze-Fracture 연구)

  • Kim, Myung-Kook
    • Applied Microscopy
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study was to investigate the morphology and intercellular junctions of the odontoblast of dental pulp in the rat incisor by means of the freeze fracture electron microscopy. Twenty male Sprague-Dawley rats weighing $150{\sim}200g$ were used. After being anesthetized by an intraperitoneal injection of 0.5 ml sodium pentobarbital per kg in body weight(60 mg/ml) the animals were perfused with 2.5% glutaraldehyde-2% paraformaldehyde fixative in 0.1 M cacodylate buffer, pH 7.2 through the ascending aorta for one hour. The incisors were carefully extracted from the jaws and demineralized by suspending them in 0.1 M EDTA in 3% glutaraldehyde (pH 7.2) for two weeks. After demineralization, the specimens were obtained from the portion divided into five equal parts. For freeze-fracture replication, demineralized tissues were infiltrated for several hours with 10%, 25% glycerol in 0.1M cacodylate buffer as a cryoprotectant and then frozen in liquid Freon 22 and stored in liquid nitrogen. Fracturing and replication were done in Balzers BAF 400D high-vacuum freeze-fracture apparatus at $-120^{\circ}C$ under routine $5X10^{-7}$ Torr vacuum. The tissue was immediately replicated with platinum unidirectionally at $45^{\circ}$ angle and reinforced with carbon at $90^{\circ}$ angle unidirectionally or by using a rotary stage. The replication process was monitored by a quartz-crystal device. The replicas were immersed in 100% methanol overnight. The tissue was then digested from the replica by clorox (laundry bleach), placed into 5% EDTA, and washed repeatedly with distilled water. The replicas were picked up on 0.3% formvar-coated 75 mesh grids and examined in the JEOL 100B electron microscope. The results were as follows; 1. Both in thin sections and freeze-fracture replicas, three types of intercellular junctions were recognizable in the plasma membrane of odontoblast: gap junction, tight junction and desmosome-like junction. 2. The nuclear pores were evenly distributed over the nuclear envelope. The pore complex formed a ring about 70 nm in diameter. 3. Gap junctions were found between odontoblasts as well as odontoblasts and neighbouring pulp cells (fibroblast, subodontoblastic cell process, nerve-like fibre). Gap junctions, which were round, ellipsoid and pear-shaped and 600 nm in diameter, were observed in the odontoblast. 4. Numerous round and ellipsoid gap junctions could be frequently seen on the plasma membranes in cell body and apical part of the odontoblasts. On the P face, the junctions were recognized as a cluster of closely packed particles, measuring about 9 nm in diameter, and on the E face, the junctions were recognized as a shallow grooves.

  • PDF

TENSILE BOND STRENGTH OF ALUNMINA CORE TREATED BY ION ASSISTED REACTION (이온보조반응법으로 처리한 알루미나 코아의 인장결합강도에 관한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung;Kwon, Kung-Rock;Choi, Boo-Byung;Choi, Won-Kook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.704-723
    • /
    • 2000
  • This study was undertaken to evaluate the tensile bond strength of In-Ceram alumina core treat-ed by ion assisted reaction(IAR). Ion assisted reaction is a prospective surface modification technique without damage by a keV low energy ion beam irradiation in reactive gas environments or reactive ion itself. 120 In-Ceram specimens were fabricated according to manufacturer's directions and divided into six groups by surface treatment methods of In-Ceram alumina core. SD group(control group): sandblasting SL group: sandblasting + silane treatment SC group: sandblasting + Siloc treatment IAR I group: sandblasting + Ion assisted reaction with argon ion and oxygen gas IAR II group: sandblasting + Ion assisted reaction with oxygen ion and oxygen gas IAR III group: sandblasting + Ion assisted reaction with oxygen ion only For measuring of tensile bond strength, pairs of specimens within a group were bonded with Panavia 21 resin cement using special device secured that the film thickness was $80{\mu}m$. The results of tensile strength were statistically analyzed with the SPSS release version 8.0 programs. Physical change like surface roughness of In-Ceram alumina core treated by ion assistad reaction was evaluated by Contact Angle Measurement, Scanning Electron Microscopy, Atomic Force Microscopy; chemical surface change was evaluated by X-ray Photoelectron Spectroscopy. The results as follows: 1. In tensile bond strength, there were no statistically significant differences with SC group, IAR groups and SL group except control group(P<0.05). 2. Contact angle measurement showed that wettability of In-Ceram alumina core was enhanced after IAR treatment. 3. SEM and AFM showed that surface roughness of In-Ceram alumina core was not changed after IAR treatment. 4. XPS showed that IAR treatment of In-Ceram alumina core was enabled to create a new functional layer. A keV IAR treatment of In-Ceram alumina core could enhanced tensile bond strength with resin cement. In the future, this ion assisted reaction may be used effectively in various dental materials as well as in In-Ceram to promote the bond strength to natural tooth structure.

  • PDF

Lip Closing Force and the Related Factors in Elementary School Children (초등학교 어린이의 평균 구순폐쇄력과 이에 영향을 미치는 요소)

  • Lee, Haney;Baek, Kyounghee;Kim, Jaegon;Lee, Daewoo;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.4
    • /
    • pp.343-352
    • /
    • 2019
  • Abnormal orofacial functions such as lip incompetency in the period of growth and development can cause morphological anomalies of the craniofacial complex. Therefore, it is crucial to make an early diagnosis based on the evaluation of the myofunctional conditions, and to make appropriate treatment plans. The objectives of this study were to quantitatively evaluate the standard lip closing force (LCF) of each age in the elementary school children, and to evaluate the relationships between LCF and affecting factors. The sample consisted of 765 children who were 7 - 12 years old in Jeonju city. Clinical examination about occlusal conditions and lip competency, and LCF measurement were performed by a single examiner. LCF was measured three times for each children with the LCF measuring device. The LCF was correlated positively with age in both sexes. The distribution of LCF groups was correlated significantly with Angle's classes and lip competency (p = 0.016, 0.004). The proportion of children with high LCFs was greater in the "competent lip" group, whereas the proportion of those with low LCFs was greater in the "incompetent lip" group.

Development of Defect Inspection System for Polygonal Containers (다각형 용기의 결함 검사 시스템 개발)

  • Yoon, Suk-Moon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.485-492
    • /
    • 2021
  • In this paper, we propose the development of a defect inspection system for polygonal containers. Embedded board consists of main part, communication part, input/output part, etc. The main unit is a main arithmetic unit, and the operating system that drives the embedded board is ported to control input/output for external communication, sensors and control. The input/output unit converts the electrical signals of the sensors installed in the field into digital and transmits them to the main module and plays the role of controlling the external stepper motor. The communication unit performs a role of setting an image capturing camera trigger and driving setting of the control device. The input/output unit converts the electrical signals of the control switches and sensors into digital and transmits them to the main module. In the input circuit for receiving the pulse input related to the operation mode, etc., a photocoupler is designed for each input port in order to minimize the interference of external noise. In order to objectively evaluate the accuracy of the development of the proposed polygonal container defect inspection system, comparison with other machine vision inspection systems is required, but it is impossible because there is currently no machine vision inspection system for polygonal containers. Therefore, by measuring the operation timing with an oscilloscope, it was confirmed that waveforms such as Test Time, One Angle Pulse Value, One Pulse Time, Camera Trigger Pulse, and BLU brightness control were accurately output.

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.