• Title/Summary/Keyword: Angle measurements

Search Result 1,336, Processing Time 0.047 seconds

INDIVIDUALIZED RECONSTRUCTION OF THE LOWER OCCLUSAL PLANE ACCORDING TO SKELETAL PATTERN (안면 골격 형태에 따른 하악 교합평면의 재구성)

  • Hyun, Seong-Wook
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.465-485
    • /
    • 1995
  • The purpose of this study is to locate the proper position of the lower occlusal plane according to individual skeletal pattern. Cephalometric films of 234 subjects of the control group, 358 of the pretreatment group and 358 of the treated group were analyzed to study proper relationships between vertical dimension ratio(VDR) and lower occlusomandibular plane angle(LOM). The control group was divided into two subgroups by the age. The first subgroup consisted of 113 subjects of the age 14 years and under and with the mean age of 10.82 years. The other subgroup consisted of 113 subjects of the age 18 years and above with the mean age of 23.76 years. The pretreatment group was divided into three subgroups by the age. The first subgroup consisted of 274 subjects of the age 14 years and under with the mean age of 11.36 years. The second subgroup consisted of 54 subjects of the age 14 through 18 years with the mean age of 15.4 years. The last subgroup consisted of 30 subjects of the age 18 years and above with the mean age of 21.35 years. The treated group was also divided into three subgroups by the age. The first subgroup consisted of 145 subjects of the age 14 years and under with the mean age of 12.91 years. The second subgroup consisted of 166 subjects of the age 14 through 18 years with the mean age of 15.64 years. The last subgroup consisted of 47 subjects of the age 18 years and above with the mean age of 21.61 years. Cephalometric films of the sample were traced. Measurements were made to a hundredth using a program specifically prepared for this study, and the results were entered into a 486DX PC. Means and Standard deviations of all the veriables were calculated for each group. Correlation coefficients between pertinent variables were calculated. Significance tests on those coefficients, one-way ANOVA and t-tests between variables or groups were performed. On the basis of the results studied above, certain subjects were selected from the control and the treated groups to locate the proper position of the occlusal plane, and designated as the optimal occluaion group. The subjects of this optimal occlusion group had 1-3 mm overbite, 1-3 mm of overjet and less than 1.75 mm of curve of Spee. A total subjects of 187 in this group consisted 104 treated subjects and 83 control group. Regression analysis was carried out between VDR and LOM, and regression equations were tabulated for this optimal occlusion group. The results were as follows : 1. Highly significant correlations were observed between various variables useful for identifying vertical component of skeletal frame, but any one particular variable did not accurately indicate the magnitude of anterior vertical overbite. 2. Of the variables useful identifying vertical component of skeletal frame, The VDR showed the highest correlation to the LOM. 3. Of the total sample, 80 percent had overbite within the normal range, irrespective of VDR. 4. The optimal occlusion group was divided into 9 subgroups by the age and the anteroposterior skeletal pattern, and correlation coefficient and determination coefficient between VDR and LOM of each group were calculated. Correlation coefficients and determination coefficients were found to be significantly high in all groups. 5. Regression equation was induced for each of the optimal occlusion group to find proper LOM according to the VDR. 6. It was found that the mean value of the cant of occlusal plane itself is not enough for a diagnosis and a treatment plan. Rather, It is very important to locate the proper occlusal plane for an Individual skeletal pattern.

  • PDF

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

An evaluation of the adequacy of pont's index (Pont 지수의 임상적 적합성에 대한 평가)

  • Kim, Seong-Hun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.115-126
    • /
    • 2000
  • Dental arch expansion is one of the method used to solve the dental crowding problem by non-extraction. Many formulae using tooth size have been suggested to predict ideal inter-premolar and inter-molar width. The purpose of this study was to evaluate the adequacy of some upper dental arch width prediction methods, namely Pont's method, Schmuth's method and Cha's method. The sample consisted of the casts of 119 Korean young adults who had no muscular abnormality, no skeletal discrepancy, and Angle's Class I molar relationships. Measurements were obtained directly from plaster casts; they Included mesiodistal crown diameters of the four maxillary incisors, as well as maxillary inter-first-premolar and inter-first-molar arch widths as specified by Pont. The correlation coefficients between the sum of incisors(SI) and upper dental arch width were calculated. The differences between predicted width and actual width were classified as overestimated, properestimated, and underestimated. The data obtained from each group were analyzed for statistical differences. The results were as follows : 1. Upper dental arch width indices were calculated from SI in normal occlusion (81.96 : premolar index, 62.55 : molar index). 2. Low correlations between SI and arch width were noted in normal occlusion (0.50 in the inter-premolar width, 0.39 in the inter-molar width). 3. Pont's formula and Schmuth's formula tended to overestimate the inter-premolar width. A more even distribution of estimates was noted in Cha's fomula. 4. Cases within $\pm$1 mm range of observed inter-premolar width were $45\%$ in the Cha's formula, $40\%$ in the Pont's formula, and $39\%$ in the Schmuth's formula. 5. All formulae had a tendency to underestimate the inter-molar width, but Cha's formula had better predictability than others. 6. Cases within $\pm$1 mm range of observed inter-molar width were $40\%$ in the Cha's formula, $29\%$ in the Pont's formula, and $13\%$ of Schmuth's formula. The data presented in this study does not support the clinical usefulness of ideal arch width prediction methods using the mesiodistal width of maxillary incisors.

  • PDF

Cephalometric differences in obstructive sleep apnea between obese and non-obese Korean male patients (한국인 성인 남성 폐쇄성수면무호흡 환자의 측모 두부 방사선계측학적 비교)

  • Hwang, Sang-Hee;Park, In-Suk;Nam, Ki-Young;Kim, Jong-Bae;Cho, Yong-Won;Suh, Young-Sung;Ahn, Byung-Hoon;Park, Shin-Goo;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.38 no.3
    • /
    • pp.202-213
    • /
    • 2008
  • Objective: The purpose of this study was to compare the cephalometric measurements of obese and non-obese Korean male patients with obstructive sleep apnea syndrome (OSA). Methods: Eighty-seven adults who had visited the Sleep Disorder Clinic Center in Keimyung University, Daegu, Korea were examined and evaluated with polysomnography (PSG) and lateral cephalogram. They were divided into 4 groups (non-obese simple snorers, obese simple snorers, non-obese OSA patients, obese OSA patients) according to AHI (Apnea-Hypopnea Index) and BMI (Body Mass Index). Results: The obese OSA group had the highest AHI among the 4 groups. The non-obese OSA group had a significantly steeper mandibular angle and shorter tongue length than the obese OSA group. The hyoid bone of the obese OSA group was positioned anterior and inferior as compared with the non-obese OSA group. Multiple regression analysis showed that tongue length in the obese OSA group and retroposition of hyoid bone in the non-obese OSA group were significant determinants for the severity of AHI. Conclusions: From a cephalometric point of view, the obese and non-obese pateints with OSA may be characterized by different pathogeneses. Therefore, they have to be managed by individualized treatment. For the obese OSA patients, weight control must be advised as a first choice and for the non-obese OSA patients, oral appliance, nasal CPAP, UPPP and others could be chosen according to the obstructive sites.

The compensatory adaptation of anterior teeth according to the skeletal relation (악골관계에 따른 전치부교합의 보상적 적응에 관한 연구)

  • Oh, Chang-Keun;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.175-183
    • /
    • 2000
  • The purpose of this study was to identify the compensatory adaptation of dentoalveolar structure according to the various skeletal relation through the statistical correlation between the anteroposterior, vertical skeletal and dentoalveolar relation. For this study, the sample were consisted of 101 adult subjects (51male and 50 female, mean age; male 23.6 years, female 21.5 years) who had good occlusion with the range of normal overjet and overbite and acceptable Angle's class I molar relationship which had not been related orthodontically The results were as follows : 1. Even though acceptable normal occlusion, the range of measurements which represent anteroposterior, vertical skeletal relation and dentoalveolar relation were very wide. 2. Upper and lower incisor axis were significantly correlated with anteroposterior skeletal relation, which means the mote lingual inclination of upper anterior teeth and the more labial inclination of lower anterior teeth according to the more anterior position of mandible to the maxilla (P<0.01). 3. Upper and 1ower anterior alveolar bone height was statistically correlated with the lower anterior vertical skeletal height. 4. Upper and 1ower alveolar bone height were not correlated with anteroposterior skeletal relation (P>0.05). 5. The correlation between the incisor axis and vertical skeletal was more closely related in upper anterior teeth than the lower anterior teeth. To summarize the above results, even though acceptable normal occlusion, skeletal and dentoalveolar relation was very widely ranged, and there were close relationship between the anteroposterior skeletal relation and the inclination of upper and lower anterior teeth and between the vertical skeletal relation and upper and lower anterior alveolar bone height. These finding can be concluded as compensatory adaptation to the different skeletal relationship.

  • PDF

Skin Damage Sustained During Head-and-Neck and Shoulder Radiotherapy Due to the Curvature of Skin and the Use of Immobilization Mask (머리-목 그리고 어깨의 방사선 치료 시 피부곡면과 고정장치로 인한 피부손상연구)

  • Kim, Soo-Kil;Jeung, Tae-Sig;Lim, Sang-Wook;Park, Yeong-Mouk;Park, Dahl
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.86-92
    • /
    • 2010
  • The purpose of this study was to measure curvature contour skin dose using radiochromic film and TLD for a conventional open field. We also attempted to quantify the degradation of skin sparing associated with use of immobilization devices for high energy photon beams and to calculate the skin dose with a help of Monte Carlo (MC) simulation. To simulate head-and-neck and shoulder treatment, a cylindrical solid water phantom 11 cm in diameter was irradiated with 6 MV x-rays using $40{\times}40\;cm^2$ field at 100 cm source axis distance (SAD) to the center of the phantom. Aquaplastic mesh mask was placed on the surface of the cylindrical phantom that mimicked relevant clinical situations. The skin dose profile was obtained by taking measurements from $0^{\circ}$ to $360^{\circ}$ around the circumference of the cylindrical phantom. The skin doses obtained from radiochromic film were found to be 47% of the maximum dose of $D_{max}$ at the $0^{\circ}$ beam entry position and 61% at the $90^{\circ}$ oblique beam position without the mask. Using the mask (1.5 mm), the skin dose received was 59% at $0^{\circ}$ incidence and 78% at $80^{\circ}$ incidence. Skin dose results were also gathered using thin thermoluminescent dosimeters (TLD). With the mask, the skin dose was 66% at $0^{\circ}$ incidence and 80% at $80^{\circ}$ incidence. This method with the mask revealed the similar pattern as film measurement. For the treatments of the head-and-neck and shoulder regions in which immobilization mask was used, skin doses at around tangential angle were nearly the same as the prescription dose. When a sloping skin contour is encountered, skin doses may be abated using thinner and more perforated immoblization devices which should still maintain immoblization.

Feasibility of MatriXX for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료의 품질관리를 위한 이온전리함 매트릭스의 유용성 고찰)

  • Kang, Min-Young;Kim, Yoen-Lae;Park, Byung-Moon;Bae, Yong-Ki;Bang, Dong-Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.91-97
    • /
    • 2007
  • Purpose: To evaluate the feasibility of a commercial ion chamber array for intensity modulated radiation therapy (IMRT) quality assurance (QA) was performed IMRT patient-specific QA Materials and Methods: A use of IMRT patient-specific QA was examined for nasopharyngeal patient by using 6MV photon beams. The MatriXX (Wellhofer Dosimetrie, Germany) was used for IMRT QA. The case of nasopharyngeal cancer was performed inverse treatment planning. A hybrid dose distribution made on the CT data of MatriXX and solid phantom all of the same gantry angle (0$^\circ$). The measurement was acquired with geometrical condition that equal to hybrid treatment planning. The $\gamma$-index (dose difference 3%, DTA 3 mm) histogram was used for quantitative analysis of dose discrepancies. An absolute dose was compared at the high dose low gradient region. Results: The dose distribution was shown a good agreement by gamma evaluation. A proportion of acceptance criteria was 95.8%, 97.52%, 96.28%, 98.20%, 97.78%, 96.64% and 92.70% for gantry angles were 0$^\circ$, 55$^\circ$, 110$^\circ$, 140$^\circ$, 220$^\circ$, 250$^\circ$ and 305$^\circ$, respectively. The absolute dose in high dose low gradient region was shown reasonable agreement with the RTP calculation within $\pm$3%. Conclusion: The MatriXX offers the dosimetric characteristics required for performing both relative and absolute measurements. If MatriXX use in the clinic, it could be simplified and reduced the IMRT patient-specific QA workload. Therefore, the MatriXX is evaluated as a reliable and convenient dosimeter for IMRT patient-specific QA.

  • PDF

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF

THE EFFECT OF DISTAL MOVEMENT OF UPPER MOLAR USING THE PENDULUM APPLIANCE (Pendulum 장치의 상악대구치의 원심이동에 대한 효과)

  • Lee, Chang-Seop;Kim, Jae-Gwang;Kang, Dug-Il;Song, Kwang-Chul;Jung, Hyun-Ku;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.488-495
    • /
    • 2001
  • Treatment of class II malocclusions require distalization of maxillary molars into class I relationship. Intraarch distal molar movement techniques have recently assumed an important role in young patients. In this study, the dental and skeletal effects of the pendulum appliance were evaluated by means of cephalometric radiographs. The samples were consisted of 19 patients: 11 females and 8 males, mean age $11.68{\pm}1.52$ years. Measurements were obtained from cephalometric prior to and the day of removal of the pendulum appliance. Treatment changes were analyzed. The following results were obtain. 1. The pendulum appliance produced $2.94{\pm}1.54mm$ distal molar movement with a mean intrusion of $1.17{\pm}0.97mm$, mean period $18.13{\pm}7.95$ weeks. 2. The anchor tooth was $1.34{\pm}1.40mm$ forward movement and $0.48{\pm}0.99mm$ extrusion, and labial tilting of incisors. 3. The angle between palatal plane and mandibular plane increased significantly. 4. There was no significant difference in according to 2nd molar position. 5. Total movement was consisted of 74% distal movement of 1st molar and 26% forward movement of the anchor tooth.

  • PDF

A Computer Simulation for Small Animal Iodine-125 SPECT Development (소동물 Iodine-125 SPECT 개발을 위한 컴퓨터 시뮬레이션)

  • Jung, Jin-Ho;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jeong, Myung-Hwan;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.74-84
    • /
    • 2004
  • Purpose: Since I-125 emits low energy (27-35 keV) radiation, thinner crystal and collimator could be employed and, hence, it is favorable to obtain high quality images. The purpose of this study was to derive the optimized parameters of I-125 SPECT using a new simulation tool, GATE (Geant4 Application for Tomographic Emission). Materials and Methods: To validate the simulation method, gamma camera developed by Weisenberger et al. was modeled. Nal(T1) plate crystal was used and its thickness was determined by calculating detection efficiency. Spatial resolution and sensitivity curves were estimated by changing variable parameters for parallel-hole and pinhole collimator. Peformances of I-125 SPECT equipped with the optimal collimator were also estimated. Results: in the validation study, simulations were found to agree well with experimental measurements in spatial resolution (4%) and sensitivity (3%). In order to acquire 98% gamma ray detection efficiency, Nal(T1) thickness was determined to be 1 mm. Hole diameter (mm), length (mm) and shape were chosen to be 0.2:5:square and 0.5:10:hexagonal for high resolution (HR) and general purpose (GP) parallel-hole collimator, respectively. Hole diameter, channel height and acceptance angle of pinhole (PH) collimator were determined to be 0.25 mm, 0.1 mm and 90 degree. The spatial resolutions of reconstructed image of the I-125 SPECT employing HR:GP:PH were 1.2:1.7:0.8 mm. The sensitivities of HR:GP:PH were 39.7:71.9:5.5 cps/MBq. Conclusion: The optimal crystal and collimator parameters for I-125 Imaging were derived by simulation using GATE. The results indicate that excellent resolution and sensitivity imaging is feasible using I-125 SPECT.