• Title/Summary/Keyword: Angiography.

Search Result 1,439, Processing Time 0.027 seconds

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Atypical Patterns of Deep Inferior Epigastric Artery: Clinical Implication of Preoperative CT Angiography (비전형적인 심하복벽동맥의 주행을 파악하기 위한 수술 전 CT Angiography의 유용성)

  • Lee, Taek-Jong;Kim, Sung-Chan;Eom, Jin-Sup;Kim, Eun-Key
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.1
    • /
    • pp.8-13
    • /
    • 2012
  • Purpose: Purpose: The free deep inferior epigastric artery perforator (DIEP) flap is a popular option for autologous breast reconstruction. However, the anatomy of the deep inferior epigastric artery(DIEA) may vary from one individual to another. Unexpected vascular anomaly can confuse the surgeon and affects on the safety of the free DIEP flap. Materials and Methods: Thirty five consecutive patients who underwent free DIEP/TRAM flap for immediate breast reconstruction between Mar. 2010 and Oct. 2010 were enrolled in this study. Computed tomography angiography (CT angiography) of abdomen was evaluated part of our standard preoperative assessment: atypical patterns of DIEA/DIEP were evaluated by preoperative CT angiography and compared with intraoperative finding. Results: Atypical patterns of DIEA/DIEP which may affect preoperative planning were noted as the following: Circummusclar/subfascial DIEA (n=1), DIEA running underneath rectus muscle (n=8), septocutaneous perforator (n=3), peritoneo-cutaneous perforator (n=1), a large branch going into peritoneum (n=1), and very early division and muscle penetration of DIEA (n=1). Conclusion: Atypical DIEA/DIEP that might change the operation plan is not rare, so the individualized planning based on the preoperative CT angiography is recommended. Preoperative CT angiography could help to select reliable and easy-to-dissect perforator in free DIEP/TRAM breast reconstruction.

  • PDF

Comparison of Doppler and CT Angiography as a Predictor of Healing Diabetic Foot Ulcers (당뇨발 치유 가능성의 예측을 위한 도플러와 CT 혈관조영술의 비교)

  • Park, Doug-John;Kim, Hyon-Surk;Han, Seung-Kyu;Kim, Hee-Young;Chun, Kyung-Wook;Kim, Woo Kyung
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.495-500
    • /
    • 2008
  • Purpose: Adequate tissue oxygenation is considered as an essential factor for wound healing. In the non-diabetic population, an uncompromised macrocirculation generally leads to adequate tissue oxygenation. On the contrary, the macrocirculation in diabetic patients may not correlate with tissue oxygenation because of structural changes in the capillary basement membrane. Nevertheless, many medical professionals in Korea rely on macrocirculation evaluation when predicting wound healing potential of the diabetic ulcers. The purpose of this study is to compare reliability of two common macrocirculation assessment methods, Doppler probing and CT angiography, on tissue oxygenation in diabetic foot patients. Methods: Doppler and CT angiography scores were given according to the patency of the anterior and posterior tibial arteries. Tissue oxygenation was measured by transcutaneous partial oxygen tension($TcpO_2$). Doppler and CT angiography scores were statistically analyzed against $TcpO_2$ values. Sixty-eight diabetic foot ulcer patients were included in this study. Results: The test was carried out on Doppler score and $TcpO_2$ variables displayed a p-value of 0.0202, and concluded that the two variables were statistically dependent. The test used to determine for linear trends between Doppler scores and $TcpO_2$ variables displayed a p-value of 0.0149, displaying statistical linear trend between the two variables. On the contrary, the tests between CT angiography scores and $TcpO_2$ variables showed p-values of 0.1242 and 0.6590, that means no correlation between CT angiography and $TcpO_2$ scores. Conclusion: Doppler probing is more reliable than CT angiography in predicting tissue oxygenation of diabetic foot ulcers.

New Carotid Artery Stenosis Measurement Method Using MRA Images (경동맥 MRA 영상을 이용한 새로운 내경 측정 방법)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1247-1254
    • /
    • 2003
  • Currently. the north american symptomatic carotid endarterectomy trial, european carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidate for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiography. rotational angiography, computed tomography angiography and magnetic resonance angiography. A new computerized carotid stenosis measuring system was developed using MR angiography axial image to overcome the drawbacks of conventional carotid stenosis measuring methods, to reduce the variability of inter-observer and intra-observer. The gray-level thresholding is one of the most popular and efficient method for image segmentation. We segmented the carotid artery and lumen from three-dimensional time-of-flight MRA axial image using gray-level thresholding technique. Using the measured intima-media thickness value of common carotid artery for each cases, we separated carotid artery wall from the segmented carotid artery region. After that, the regions of segmented carotid without artery wall were divided into region of blood flow and plaque. The calculation of carotid stenosis degree was performed as the following; carotid stenosis grading is(area measure of plaque/area measure of blood flow region and plaque) * 100%.

Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography (두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안)

  • Park, Chan Woo;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.399-406
    • /
    • 2019
  • This study aims to find geometric parameters that the radiologist can change from time to time to reduce dose in angiography examinations. Depending on the geometric characteristics, the values calculated by effective dose were compared, while filming in fluoroscopy mode and Digital subtraction angiography, respectively. The study found that the lower the dose was in FPS mode, the lower the dose was reduced to 30-40%. Doses according to the X-ray angle were measured highest in AP View and lower as the angle went in the head direction. The greater the FOV, the higher the dose was 1.2-1.6 times, and the closer the distance between the X-ray tube and the table, the greater the dose was about 10%. Source-image intensifier distance (SID) get longer to 100 mm, dose of each fluoroscopy and Digital subtraction angiography increase up to 25-30%. In conclusion, various geometric characteristics in angiography examinations are parameters that can be applied by radiographers as frequently as possible, and appropriate geometric properties can be considered and applied in various situations, resulting in appropriate dose reduction.

Analysis and Evaluation of Pathogen Contamination Status in Interventional Angiography Room (인터벤션실의 오염실태 분석 및 평가)

  • Kim, Kyung-Wan;Im, In-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.233-239
    • /
    • 2022
  • In the radiology department, where radiation is used in medical institutions to perform examinations with various equipment, the field of surgical treatment is the intervention angiography room. Accordingly, strict infection control is required. The purpose of this study was to determine the contamination status by detecting pathogens before and after disinfection in the intervention angiography room, and to determine the degree of death by using a disinfectant, sodium dichloride isocyanurate, which is mainly used in the intervention angiography room. The subjects were 10 medical institutions of general hospital level or higher with an intervention angiography room in the P city, and 12 places with high contact frequency during examinations and procedures were sampled and requested to an analysis institution. As for the sample collection method, up/down, left/right directions were used to increase precision. Before disinfection, all procedures were completed, and after disinfection, exposure was performed using a disinfectant for at least 10 minutes, and detection was performed using a transport medium. As a result, in the pathogen analysis, most pathogens were detected in a humid environment or in a place with high contact frequency for microorganisms to thrive. The detected pathogens were found in the general environment or were human flora. It is a pathogen that does not cause disease under normal healthy host conditions. However, it was found to be an opportunistic infection that causes opportunistic infection depending on the case or situation in which the body's resistance is weakened. In addition, as a result of using the disinfectant mainly used in the intervention angiography room, it was found that more than 93.3% of them died. Therefore, the data of this study will be used as good basic data for the evaluation of pathogens in the intervention angiography room and will be of great help in infection control.

The Evaluation of Carotid Artery Stenosis Using Spiral CT. (Spiral CT를 이용한 경동맥 질환의 평가)

  • Yoon, Hee-Suk;Hwang, Yun-Chean;Shin, Hyun-Kil;Beak, Cheon-Ki;Yoon, Suck-Min
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

Development of 'De novo' Aneurysm after Therapeutic Carotid Occlusion

  • Jin, Sung-Chul;Choi, Choong-Gon;Kwon, Do-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.236-239
    • /
    • 2009
  • Carotid occlusion is an inevitable therapeutic modality for the treatment of complex aneurysms such as giant, traumatic, and intracavernous aneurysms. Late complications of carotid occlusion include 'de novo' aneurysm formation at a distant site because of hemodynamic changes in the circle of Willis. We report a case of de novo aneurysm in a vessel that appeared to be normal on initial angiography. The patient developed an anterior communicating artery aneurysm and marked growth of a basilar bifurcation aneurysm 9 years after trapping of the left internal carotid artery for the treatment of a ruptured large saccular aneurysm involving ophthalmic and cavernous segments. We propose that patients who undergo therapeutic carotid occlusion should be periodically followed by magnetic resonance angiography or computed tomographic angiography to evaluate the possibility of de novo aneurysm formation; this advice is in line with previous reports.

Magnetization Transfer Contrast Angiography for Organized Thrombosed Intracranial Aneurysm in TOF MR Angiography: a Case Report

  • Kang, Dong-Hun;Lee, Hui Joong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • A 66-year-old woman was referred for treatment of incidental detection of two intracranial aneurysms. Time-of-flight MR angiography (TOF MRA) revealed two aneurysms at the M1 segment of the right middle cerebral artery, and clinoid segment of left internal carotid artery, respectively. On digital subtraction angiography, there was a saccular aneurysm on the left internal carotid artery, but the other aneurysm was not detected on the right middle cerebral artery. Based on comprehensive review of imaging findings, organized thrombosed aneurysm was judged as the most likely diagnosis. In the presented report, magnetization transfer (MT) pulse to TOF MRA was used, to differentiate aneurysm-mimicking lesion on TOF MRA. We report that MT technique could be effective in differentiating true aneurysm, from possible T1 high signal artifact on TOF MRA.

Transient Global Aphasia with Hemiparesis Following Cerebral Angiography : Relationship to Blood Brain Barrier Disruption

  • Kim, Dong-Ha;Choi, Chang-Hwa;Lee, Jung-Hwan;Lee, Jae-Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.524-527
    • /
    • 2010
  • Temporary disruption of the blood-brain barrier (BBB) after cerebral angiography is presumably caused by nonionic radiographic contrast medium (CM). We hereby report a case of 58-year-old woman who developed decreased mentality, global aphasia and aggravated right hemiparesis after cerebral angiography. Brain CT examination demonstrated gyriform enhancement throughout the left cerebral cortex and thalamus. MR diffusion did not reveal acute infarction. MR angiography did not show any stenosis, spasm or occlusion at the major cerebral vessels. Follow-up CT scan after 1 day did not show any gyriform enhancement. Worsened neurologic signs and symptoms were improved completely after 7 days. In the present study, disruption of the BBB with contrast medium after angiography seems to be the causative factor of transient neurologic deterioration.