• Title/Summary/Keyword: Aneurysm, thoracic aortic

Search Result 294, Processing Time 1.51 seconds

Surgical Treatment of Annuloaortic Ectasia - Review of 4 cases - (Annuloaortic ectasia의 외과적 치험)

  • Lee, S.;Ahn, W.S.;Kim, B.Y.;Lee, J.H.;Yu, H.S.
    • Journal of Chest Surgery
    • /
    • v.24 no.1
    • /
    • pp.36-40
    • /
    • 1991
  • Between November, 1981 and July, 1989, 4 patients, 3 male and 1 female patients ranging in age from 36 to 45 years, were operated on for aortic insufficiency associated with uncomplicated annuloaortic ectasia. All patients were in New York Heart Association class III. Two patients had clinical stigmata of the Marfan syndrome. The surgical treatment consisted of. supracoronary replacement of ascending aorta with vascular graft and replacement of the aortic valve in our first case. and composite graft replacement of the ascending aorta and aortic valve with reimplantation of the coronary arteries in subsequent 3 cases. Our first patient developed aneurysm of proximal aorta and pseudoaneurysm of distal aortic anastomosis 5 years postoperatively. One patient among the three patients with Ben-tall operation, died of ventricular fibrillation and myocardial failure during immediate postoperative period. Remaining 2 patients were in NYHA class I with follow-up of 16 months and 20 months respectively.

  • PDF

Surgical Treatment of the Descending Thoracic Aorta ; An analysis of 22 cases (하행 흉부 대동맥류의 외과적 치료; 22예의 분석)

  • 이홍섭;이선훈;윤영철;구본일;김창호
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.532-535
    • /
    • 1999
  • Background: The purpose of this study was to evaluate and analyze the surgical techniques and postoperative complications in patients undergoing operations for descending thoracic aortic aneurysms. Material and Method: The data of 22 major operations between March 1987 and August 1997 were retrospectively reviewed. Result: There were 18 men and 4 women with a mean age of 49 years (range 33 years to 82 years). The cause of the aneurysm was aortic dissection in 13 patients, atherosclerosis in 3, mycotic in 3, trauma in 2 and uncertain in 1. The operative techniques were resection and graft replacement in 16, axillofemoral bypass graft in 2, femorofemoral bypass graft in 2, exclusion, aneurysmorrhaphy in 1 and transfemoral stent insertion in 1. During the operation, 16 cases were performed under total aortic clamp. Among the 16 patients, femorofemoral bypass was used in 14 cases and previously made shunt in 2 cases. The mean total aortic clamp time was 91 minutes and the mean extracorporeal circulation time was 116 minutes. One death occurred in an excluded patient on the 52 postoperative day due to a rupture of the aneurysm. Postoperative complications were paraplegia in 1 case, acute renal failure in 1 case and acute respiratory failure in 1 case. Conclusion: Although surgical treatment of the descending thoracic aneurysm has many postoperative complications, good surgical results can be achieved with a proper patient selection and fine surgical techniques.

  • PDF

Ruptured Aneurysm of Aortic sinus of Valsalva -A Report of 6 Cases- (대동맥동 동맥루 파열 -수술치험 6예-)

  • 이종명
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.201-208
    • /
    • 1974
  • The purpose of this paper is to present author's experience with 6 cases of ruptured aneurysm of sinus of Valsalva which were treated surgically during last 10 years. Among the 6 cases, 5 were male and one was female. All of them originated from the right coronary sinus and 5 cases were ruptured into the RV while remained one into RA. The diagnosis was obtained in 4 cases by cineangiocardiogram. Clinically, we had difficulties in differential diagnosis with combined cases of VSD with A.I. and had special experience in its differentiation during cardiac catheterization. By simultaneous trans-venous and trans-arterial catheterization, identified two catheter tips in the RV, and pull back tracing obtained aortic pressure directly from RV, and RA from RV pressure which were benefit in confirm ruptured aneurysm of the aortic sinus. Surgical correction was performed by means of direct suture closure or combined Teflon pledget Of patch enforcement graft after aneurysm resection by trans-RA or trans-RV approach. All patients had no history of bacterial endocarditis, syphilis, or tuberculosis and operative findings revealed intact coronary sinus except involved one moreover 3 cases combined with high VSD which uggested congenital in origin although pathologic reports revealed only fibrosis. Post-operative course were uneventful in all cases but one who had bleeding and 2 months to 9 years follow up results were good and spend their usual life in all cases.

  • PDF

Traumatic descending aortic aneurysm -Report of one case- (외상성 하행대동맥류 수술치험 1례)

  • 이신영
    • Journal of Chest Surgery
    • /
    • v.24 no.5
    • /
    • pp.505-509
    • /
    • 1991
  • Rupture or laceration of the aorta is a more common result of nonpenetrating traumatic injury than is generally appreciated. If the lesion is promptly diagnosed, a appropriate surgical treatment may be life-saving. Diagnosis may be difficult and at times the rupture may remain clinically silent for variable period.< A 34 - year old male patient had sustained steering wheel injury to his chest during automobile accident 8 weeks prior to admission. The diagnosis of traumatic aneurysm of the aorta was delayed as he was asymptomatic. Surgical repair of false aneurysm of the descending aorta was successfully performed by partial cardiopulmonary bypass through the femoral artery and vein.

  • PDF

Clinical Analysis of Surgery for Aortic Disease (대동맥 질환 수술의 임상적 고찰)

  • 안정태
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.906-911
    • /
    • 1995
  • From January 1991 to January 1995, 11 patients with aortic diseases underwent various surgical repairs. The age at operation ranged from 26 years to 63 years[ mean=50.9 years . The disease entities included 8 aortic dissections[ type I in 4, type II in 2 and type III in 2 cases , 2 Marfan`s syndrome with annuloaortic ectasia and 1 desecending thoracic aortic aneurysm The operative procedures we tried were 3 Bentall`s operation, 5 graft replacement of ascending aorta, and 3 graft interposition in descending thoracic aorta.Overall hospital mortality rate is 36.3%[4/11 . And causes of death are pump weaning failure in 2 cases and multiorgan failure in 2 cases. It was that 2 sternal dehiscence & mediastinitis, 1 acute renal failure, 2 hypoxic brain damages and 2 postoperative psychosis were complicated. Recently we tried surgical repair of aortic dissection five out of 6 cases using total circulatory arrest with deep hypothermia at 14$^{\circ}C$. Total circulatory arrest time ranged from 18 to 26 minutes[ mean 22.2 minutes , and mean aortic cross-clamping time was 48.2 minutes. One of 5 patient died on the 7th postoperative day due to multiorgan failure. Mortality of patients with TCA was 20%[1/5 , and it of remainders was 50%[3/6 . Our result for surgical repair using total circulatory arrest with deep hypothermia is satisfactory on the basis of our clinical data.

  • PDF

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Total Aortic Replacement - A Case Report - (대동맥 전장 치환 치험 1례)

  • Kim, Doo-Sang;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.173-177
    • /
    • 1998
  • A 28 years old pregnant woman(Gestational age 35 weeks) had been operated emergency Cesarian section for delivery and emergency graft replacement of ascending aorta and total arch for acute type A aortic dissection. 1 year and 6 months later, she underwent aortic graft replacement from descending thoracic aorta to both common iliac arteries because of further progression of aortic dissection. So far she has a complete artificial graft aorta.

  • PDF

Aortopulmonary Fistula after Surgical Intervention of Acute Aortic Dissection (급성 대동맥류 수술후 원위부에 발생한 Aortopulmonary Fistula 치험 1례)

  • Cho, Gwang-Jo;No, Jae-Ook;Woo, Jong-Soo
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.178-181
    • /
    • 1998
  • Among the late postoperative complications of the acute dissection of aorta, the fistula between dilated distal aorta and pulmonary parenchym is so rare that only few case have been reported sporadically. Although the aortopulmonary fistula is one of a fatal condition that needs prompt surgical intervention, with an appropriate management it is well controllable condition. Early diagnosis and urgent surgical intervention is the only way to prevent catastrophic hemorrhage. We experienced a surgical management of aortoplumonary fistula which occurred between upper lobe of the left lung and distal aortic dilatation of previous aortic bypass graft which was performed for Debakey type I acute aortic dissection.

  • PDF

Successful Repair of Type I Endoleak Using the Frozen Elephant Trunk Technique

  • Kim, Seon Hee;Song, Seunghwan;Kim, Sang-pil;Lee, Chung Won;Son, Joohyung
    • Journal of Chest Surgery
    • /
    • v.49 no.4
    • /
    • pp.298-301
    • /
    • 2016
  • Thoracic endovascular aortic repair (TEVAR) has emerged as an effective therapy for a variety of thoracic aortic pathologies. However, various types of endoleak remain a major concern, and its treatment is often challenging. We report a case of type I endoleak occurring 19 months after zone II hybrid TEVAR. The endoleak was successfully repaired by the frozen elephant trunk technique, without removal of a previous stent graft, combined with ascending aorta and total arch replacement.