A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF

일부 음식점 주방의 부유세균 및 부유진균 조사연구 (Assessment of Bacterial and Fungal Aerosols in the Kitchens of Restaurants)

  • 김종규;박정영;김중순
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.98-104
    • /
    • 2014
  • Objectives: The purpose of this study was to determine airborne bioaerosols such as bacteria and fungi in the kitchens of restaurants, and to assess the effects of thermal factors on the levels of the bioaerosols. Methods: Air samples were taken from kitchens of nine restaurants. An Anderson type air sampler was used for sampling and measurements. Petri dishes filled with a microbiological culture medium (trypticase soy agar for bacteria and Sabouraud dextrose agar for fungi) were used as the sampling surface. Results: The levels of bacterial aerosol measured were $10-10^3CFU/m^3$ and fungal aerosol $10-10^2CFU/m^3$, respectively The mean values of air temperature and relative humidity in the kitchens were $24.6^{\circ}C$ and 46.4%, respectively. Overall, the levels of bacterial aerosol varied by the restaurant type, and fungal aerosol by the business period (p < 0.05). The main effect of air temperature and interaction effect of air temperature and relative humidity onto the bacterial level were significant (p < 0.05), whereas the effects were not significant onto the fungal level. Conclusions: The results indicate a wide variation in the levels of bioaerosols among different kitchens. The observed differences in bioaerosol levels in the kitchens reflect different periods of use. The interactions of air temperature and relative humidity onto the bacterial level suggest that constant attention should be paid to avoid peaks of contamination during the summer season.

화장실 공기 중 미생물 분포 조사연구 (Assessment of Bioaerosols in Public Restrooms)

  • 김종규;김아혁;김중순
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.304-312
    • /
    • 2014
  • Objectives: This study was performed to examine bioaerosols in indoor air in public restrooms, as well as to assess the effects of air temperature and relative humidity on bioaerosol levels. Methods: A cross-sectional survey was performed in ten male and ten female restrooms. An air sampler (Anderson type) was used for sampling total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram-positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The levels of TSB were $10-10^2CFU/m^3$ and TSF $10-10^2CFU/m^3$, respectively. The GNB level was $0-10CFU/m^3$, and GPB and OP levels were $10-10^2CFU/m^3$. Staphylococcus aureus and methicillin-resistant S. aureus (MRSA) were detected in 90% of the restrooms. The GPB level was higher in the female restrooms than in the male restrooms (p < 0.05). TSB, GNB, and TSF showed higher levels in restrooms in buildings over 30 years old (p < 0.01). The main effect of air temperature or relative humidity and interaction effect of the two factors on the TSB level were significant (p < 0.05), while the effect of relative humidity on the TSF level was significant (p < 0.001). Conclusions: These results indicate that there is a wide variation in the bioaerosol levels among different restrooms. The observed differences in bioaerosol levels reflect different building histories. The effects of air temperature and/or relative humidity reveal that bioaerosol levels may vary according to season or time of day. Future research is needed to further characterize the relation between the bioaerosol levels and surface contamination in restrooms.

대기 중 다환방향족 탄화수소류의 오염도 변화 특성 (Variations and Trends in Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Air)

  • 정용;박성은;황만식;홍지연
    • Environmental Analysis Health and Toxicology
    • /
    • 제13권1_2호
    • /
    • pp.43-53
    • /
    • 1998
  • Ambient air levels of polycyclic aromatic hydrocarbons(PAHs) are of concern because of their potential for adverse health effects including transformation of some of these substances to mutagens and carcinogens by mammalian microsomal enzyme system. Airbone particulate samples were collected by a conventional high-volume sampler and by an Anderson cascade impactor on 2 to 3 days in each month over a period of 1 year at a representative site of the heavy traffic area of Seoul from beptember 1994 to August 1995. Ten individual PAHs in sizable air particulates of each stage of two months were separated and analyzed by gas chromatography/mass spectrometry. As a results of analysis, the gross concentrations of PAHs in the fine and coarse particles were higher in the winter month than in the spring, followed in descending order by in the fall and summer. In a study of dependency of 10 PAHs compounds on size distribution of particles at heavy traffic area found that about 85% of the total PAHs content was associated with particles less than 2.0um (fine particles) in diameter of winter sampling period. while 79% were associated with this size fraction during summer period. In according to the mean concentrations of the 10 PAHs in 7 size classification from < 0.38 to> 10.1, the 'size was the smaller, PAHs concentration was the higher. Thus it was found that PAHs concentration was greatly affected by air particle size. Annual mean benzo(a)pyrene equivalents was 5.88ng/m$^3$ and obtained by applying, toxic equivalency factor developed by Nisbet and Lagoy.

  • PDF

Respiratory Disorders Among Workers in Slaughterhouses

  • Kasaeinasab, Abbasali;Jahangiri, Mehdi;Karimi, Ali;Tabatabaei, Hamid Reza;Safari, Sonia
    • Safety and Health at Work
    • /
    • 제8권1호
    • /
    • pp.84-88
    • /
    • 2017
  • Background: Workers in slaughterhouses are exposed to a wide range of biological contaminants, such as bacteria and fungi, due to their working environment. This study aimed to assess the prevalence of respiratory disorders among workers in slaughterhouses. Methods: This study was conducted on 81 workers in slaughterhouses and 81 healthy office workers as a reference group. The American Thoracic Society standard respiratory symptoms questionnaire was used to determine the prevalence of respiratory disorders. Besides, lung function tests were conducted using a calibrated spirometer at the beginning (preshift) and at the end (postshift) of the $1^{st}$ working day. Single-stage Anderson sampler was used to measure the concentration of bioaerosols in different parts of slaughterhouses. Results: The prevalence of respiratory disorders, such as cough, productive cough, breathlessness, phlegm, and wheezing, was 3.17, 4.02, 3.07, 4.66, and 3.94 times, respectively, higher among workers in slaughterhouses compared with the reference group. Conclusion: The prevalence of respiratory disorders was significantly higher among workers in slaughterhouses. Thus, the significant reduction in the percentage predicted lung function among workers in slaughterhouses might be associated with exposure to bioaerosols in their work environment.

성남시 대기정유분새중 호흡성 분여에서 중금속의 농도 및 입경분포 (The Heavy Metals and Size Distribution of Respirable Suspended Particulate Matter at Sungnam City)

  • 권우택;유영식
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1994
  • Sungnam city, as a major satellite town, is located in the southeast of Seoul. Atmospheric conditions are so stable that air pollutants from various emissions are tend to resist change because Sungnam city is located in the Namhansansung valley. The industrial distribution of Sungnam city are composed of various manufactories such as foods, fibers, chemicals, machinery and electronics etc. The heavy metal concentrations and size distribution are the most important parameters influencing among the way in which respirable suspended particulate matter interact with the human respiratory system. Respirable suspended particulate matter was collected on glass fiber filters from April 1993 to February 1994 according to particle size using Anderson sampler during 10 days per month at Sungnam city. 6 heavy metals, Fe, Zn, Pb Mn, Cu and Cd, were analyzed by particle size with atomic absorption spectrophotometry . The results could be summarized as follows: 1. The annual arithmetic mean concentration of total suspended particulate was 116.3$\mu $g/m$^{3}$ m', seasonal variation was the highest in spring season(196.5$\mu $g/m$^{3}$) and the lowest in Summer Season(72.9$\mu $g/m$^{3}$). 2. The ratio of airborne particulate concentrations respirable to nonrepairable( Res/Non- Res) of annual arithmetic mean value was 5.8'1, seasonal variation was highest in the spring season(6.3 : 1) and lowest in the summer season(4.6 : 1). 3. During the spring season the shape of the size distribution was trimodal which showed peaks at 3 size groups, which were below of 0.43$\mu $m, 3.3∼4.7$\mu $m and above of 11.0$\mu $g/m$^{3}$ respectively. 4. Respirable suspended particulate matter concentrations of Zn, Pb Cu and Cd were the highest in below of 0.43$\mu $m as follows; 0.517$\mu $g/m$^{3}$, 0.411 $\mu $g/m$^{3}$, 0.062$\mu $g/m$^{3}$ and 0.0310$\mu $g/m$^{3}$ , respectively, Fe and Mn were the highest in the particle size range of 4.7 ∼ 7.0$\mu $m as follows; 2.504$\mu $g/m$^{3}$ and 0.095$\mu $g/m$^{3}$, respectively. 5. The Pt Cd, Zn, Cu, Fe and Mn concentrations of annual arithmetic mean value respirable to non- respirable( Res/Non- Res ) were 33.65, 19.27, 17.74, 10.54, 3.20 and 5.20, respectively.

  • PDF

일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자 (Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities)

  • 황성호;조현우;박동욱;윤충식;류경남;하권철
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.