• 제목/요약/키워드: And temperature

검색결과 86,713건 처리시간 0.08초

온돌난방에서의 자세에 따른 온열생리적 반응의 성차 (Effectsd of posture on physiological thermal responses with Ondol heating system)

  • 신정화;최정화
    • 한국의류학회지
    • /
    • 제22권8호
    • /
    • pp.1020-1031
    • /
    • 1998
  • This study was done to investigate thermal reponses and to obtain the basic information of thermal comfort by sex and posture under the Ondol heating system. Six healthy males and females were exposed to Ondol(Room Temp.: 25$\pm$1$^{\circ}C$, 50$\pm$10%R.H, Floor Temp.:30$\pm$1$^{\circ}C$) on the of posture such as sitting, lying aside and supine on the floor for 30 minutes after 30 minutes' control phase. During the experiment, rectal temperature, skin temperature of 10 areas, local sweating rate, clothing microclimate, subjective sensation were measured. Rectal temperature gradually decreased and mean skin temperature grad-ually increased both male and female in any posture. There was not significant difference between male and female in rectal temperature and mean skin temperature. There were significant difference among the postures in rectal temperature(p<0.001) and mean skin temperature(p<0.001). In lying aside and supine on the floor, appearances of change and changes in rectal temperature and mean skin temperature were large, changes of weight were small. In sitting on the floor, appearances of change and changes in rectal temperature and mean skin temperature were small, changes of weight were large. The trunk skin tem-perature was higher in female than in male, but the extremity skin temperature was higher in male than in female. In sitting on the floor, foot skin temperature(p<0.001) was higher than any other local skin temperature. In supine on the floor, back skin temperature(p<0.001) was higher than any other local skin temperature.

  • PDF

이중관 구조 박막형 순간온도 프로브의 응답성에 관한 연구 (A Study on the Responsibility of Thin film instantaneous surface temperature probe of a Dual-pipe structure)

  • 최석렬;박경석
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.237-242
    • /
    • 2003
  • The measurement study of instantaneous temperature at combustion chamber wall and the temperature of combustion gas has been under lots of research and development to conclude the temperature process in internal combustion engine for combustion characteristics analysis. The measurement with fast responsibility should be used for temperature measurement inside combustion chamber wall since temperature of wall changes, due to the various gas temperature, irregularly during the combustion. Therefore, thin film instantaneous surface temperature probe, which characterizes the fastest and the most accurate responsibility among contact typed temperature measurement, was used for the experiments. This new thin film instantaneous surface temperature probe improved the problems of noise and durability. The optimal coating thickness of thin film instantaneous surface temperature probe was proven to be $10{\mu}m$ for the best responsibility and durability. It also allowed the stable temperature measurement be taken up to $1,200^{\circ}C$ and proven to be read possibly from the combustion chamber wall.

  • PDF

각 환경기온하에서의 성인남자 피부온에 관한 연구 (A study on the variation of skin temperature on the adult male at environment temperature)

  • 심부자
    • 대한인간공학회지
    • /
    • 제15권2호
    • /
    • pp.71-88
    • /
    • 1996
  • For understanding skin temperature based on clothing design from a viewpoint of comfortable wearing, the skin temperature, physiological reactions(body temperature, blood pressure and pulse) and physilolgical response(thermal sensation, comfort sensation and perceptive sweaty sensation) were measured on condition tha t5 naked healthy male exposed to serveral environmental temperatures,( $20{\pm}1.0^{\circ}C$ ,$28{\pm}1.0^{\circ}C$ and $32{\pm}1.0^{\circ}C$). As the results of this testing, the regional skin temperature was varied for 90min just after expose to those the environment but was generally stabilized for the nest 90min. It was proved the difference of the regional skin temperature at low temperature environmental($20{\pm}1.0^{\circ}C$) was larger than at high temperature environmental($32{\pm}1.0^{\circ}C$) and inder serveral environmental temperature,the degree of the regional skin was not equal. Except in case of the thigh, the front of all regional skin temperature turned out higher than the back of them. According to change of environmental temperature, body temperature and pulse were altered. In the pshycological response, 'thermal sensation-comfort sensation' was felt to 'slightly warm - comfortable' at $28{\pm}1.0^{\circ}C$of the environmental temperature, and 'perceptive sweaty sensation', wneh it was said 'sweat' at only $32{\pm}1.0^{\circ}C$ of it.

  • PDF

궤도 관리를 위한 레일 온도의 특성 (The Characteristics of Rail Temperature for Track Maintenance)

  • 구봉근;서사범
    • 한국철도학회논문집
    • /
    • 제3권1호
    • /
    • pp.19-26
    • /
    • 2000
  • The rail temperature is important to preserve the joint gap for standard length of rail and to determine the installation temperature which has direct influence on the rail buckling and failure in welded part for continuous welded rail(CWR), Therefore, we have measured and investigated various characteristics of rail temperature for each kind of rail. As the results of this, the correlation between the atmosphere temperature and the rail temperature which is commonly used by Korean Railway should be reconsidered. Also, the daily highest '||'&'||' lowest rail temperature was occurred when each temperature is higher and when it's lower. For the light rail, the rail temperature by the sun-light increases quickly and decreases late. But the time where the highest temperature is attained is same. There are some differences between the shade and sunny place about 3.0∼4.0$\^{C}$. The temperature of rail web is almost close to the conversion rail temperature for rail expansion. The wind of 1 m/s has an influence on the rail temperature around 5$\^{C}$.

  • PDF

체온측정에 필요한 최단적정시간규명을 위한 실험적 연구 (An Experimental Study on the Shortest optimum time for Body Temperature measurement)

  • 홍여신;이선옥
    • 대한간호학회지
    • /
    • 제5권2호
    • /
    • pp.38-50
    • /
    • 1975
  • This study was conducted to find the shortest optimum time for taking oral temperature and axillary temperature, which does not affect reliability of body temperature. For this purpose, first, the time at which all the samples are reaching maximum temperature is identified Second, the mean maximum temperature is compared with the mean temperature of each consecutive measurement by T-test to find the time at which no significant changes in temperature occurs along time sequence. Third, optimum temperatures are set at points of -0.2℉, -0.4℉, -0.6℉, -0.8℉, -1.0℉, -1.2℉, -1.4℉, from maximum temperature. A point of time at which 90% of samples reach at optimum temperature is identified and defined as optimum time. The study sample, a total of 164 cases were divided into two groups according to their measured body temperature. The group with body temperature below 37 $^{\circ}C$(A group) and above 37$^{\circ}$1'C (B group) were compared on the time required to reach maximum temperature and optimum temperature. The results are as follow. 1. The time required for total sample to reach maximum temperature was 13 minutes in both groups by oral method, 15 minutes in A group and 13 minutes in B group by axillary method. Time required for 90 % of cases reach maximum temperature by oral method was 10 minutes in both group. By axillary method, 12 minutes in A group. (Ref: table 2) 2. Statistical analysis by means of T-test, the time which does not show a significant change by oral method were 12 minutes in A group and 11 minutes in B group, and by axillary method 14 minutes in A group and 11 minutes in B group. (Ref: table 5, 6.) 3. Where optimum temperature was defined as maximum temperature minus 0.2 ℉, optimum time was found 8 minutes in both groups by oral method, and 11 minutes in A group and 9 minutes in B group by axillary method 4. Where optimum temperature was defined as maximum temperature minus 0.4 ℉, optimum time was found 7 minutes in A group and 6 minutes in B group by oral method, and 9 minutes in A group and 7 minutes in B group by axillary method 5. Where optimum temperature was defined as maximum temperature minus 0.8 ℉, optimum time was found 6 minutes in A group and 6 minutes in B group by axillary method (Ref: table 7, 8, 9, 10) 6. The commonly practiced temperature taking time, 3 minutes in oral method and 5 minutes in axillary method can be accepted as pertinent when physiological variation of body temperature at the mean level of -1, 2 ℉ is accepted. 7. The difference in time required to resister maximum temperature was compared between the group with body temperature below 37$^{\circ}C$ and above 37$^{\circ}$1'C, and found no significant difference in oral mettled and 1 - 4 minute difference in axillary method with shorter time requirement in feverish group.

  • PDF

기후변화에 따른 지표수의 수온 영향평가 (Projected Climate Change Impact on Surface Water Temperature in Korea)

  • 안종호;한대호
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.133-139
    • /
    • 2010
  • Global human activities associated with the use of fossil fuels have aggravated climate change, increasing air temperature. Consequently, climate change has the potential to alter surface water temperature with significant impacts on biogeochemical cycling and ecosystems in natural water body. In this study, we examined temporal trends on historical records of surface water temperature, and investigated the air temperature/water temperature relationship and the potential water temperature change from an air temperature scenario developed with regional climate model. Although the temporal trends of water temperature are highly variable site-by-site, surface water temperature was highly dependent on air temperature, and has increased significantly in some sub-watersheds over the last two decades. The results presented here demonstrate that water temperature changes are expected to be slightly higher in river system than reservoir systems and more significant during winter than summer for both river and reservoir system. Projected change of surface water temperature will likely increase $1.06^{\circ}C$ for rivers and $0.95^{\circ}C$ for reservoirs during the period 2008 to 2050. Given the potential climatic changes, every $1^{\circ}C$ increase in water temperature could cause dissolved oxygen levels to fall every 0.206 ppm.

인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교 (Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter)

  • 조성환;홍성기
    • 설비공학논문집
    • /
    • 제27권4호
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.

링발진기를 이용한 CMOS 온도센서 설계 (Design of CMOS Temperature Sensor Using Ring Oscillator)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제19권9호
    • /
    • pp.2081-2086
    • /
    • 2015
  • 링 발진기를 이용한 온도센서를 공급전압 1.5volts를 사용하여 0.18㎛ CMOS 공정으로 설계하였다. 온도센서는 온도가 변화하더라도 일정한 출력주파수를 가지는 링 발진기와 온도가 증가하면 출력주파수가 감소하는 링 발진기를 이용하여 설계하였다. 온도를 디지털 값으로 변환하기 위해 온도에 무관한 링 발진기의 출력 신호는 카운터의 클럭 신호로 사용하였으며, 온도에 따라 변화하는 링 발진기의 출력신호는 카운터의 인에이블 신호로 사용하였다. 설계된 회로의 HPICE 시뮬레이션 결과 회로의 동작온도가 -20℃에서 70℃까지 변화할 때 온도 에러는 -0.7℃에서 1.0℃ 이내였다.

Characteristics of soil respiration temperature sensitivity in a Pinus/Betula mixed forest during periods of rising and falling temperatures under the Japanese monsoon climate

  • Oe, Yusuke;Yamamoto, Akinori;Mariko, Shigeru
    • Journal of Ecology and Environment
    • /
    • 제34권2호
    • /
    • pp.193-202
    • /
    • 2011
  • We studied temperature sensitivity characteristics of soil respiration during periods of rising and falling temperatures within a common temperature range. We measured soil respiration continuously through two periods (a period of falling temperature, from August 7, 2003 to October 13, 2003; and a period of rising temperature from May 2, 2004 to July 2, 2004) using an open-top chamber technique. A clear exponential relationship was observed between soil temperature and soil respiration rate during both periods. However, the effects of soil water content were not significant, because the humid monsoon climate prevented soil drought, which would otherwise have limited soil respiration. We analyzed temperature sensitivity using the $Q_{10}$ value and $R_{ref}$ (reference respiration at the average temperature for the observation period) and found that these values tended to be higher during the period of rising temperature than during the period of falling temperature. In the absence of an effect on soil water content, several other factors could explain this phenomenon. Here, we discuss the factors that control temperature sensitivity of soil respiration during periods of rising and falling temperature, such as root respiration, root growth, root exudates, and litter supply. We also discuss how the contribution of these factors may vary due to different growth states or due to the effects of the previous season, despite a similar temperature range.

TDLAS에서 temperature binning 방법을 이용한 온도 측정에 대한 실험적 연구 (Experimental study on TDLAS temperature profile measurement using temperature binning method)

  • 윤성운;김세원;신명철;이창엽
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.27-28
    • /
    • 2012
  • Tunable diode laser absorption spectroscopy(TDLAS) measurement techniques for several gases densities and temperatures have been applied in industrial combustion systems. Accurate measurement of temperature profile is very important, especially in power plants and heating furnaces. So profile fitting and temperature binning methods are new issue for accurate measurement of temperature in laser gas sensing. Temperature binning method is applied in this study for the measurement of temperature profile using tube furnace with three temperature zones. In this study the temperature profiles of tube furnace is accurately measured within 5% error, and this technique is proved to be very promising in the field of temperature profile measurement.

  • PDF