• Title/Summary/Keyword: Anchorage system

Search Result 221, Processing Time 0.024 seconds

SAR Measurements of Surface Displacements at Augustine Volcano, Alaska, Associated with the 1986 and 2006 Eruption

  • Lee, C.W.;Jung, H.S.;Won, J.S.;Lu, Z.;Kwoun, O.I.
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.401-404
    • /
    • 2007
  • Augustine volcano is an active stratovolcano located at the southwest of Anchorage, Alaska. Augustine volcano had experienced seven significantly explosive eruptions in 1812, 1883, 1908, 1935, 1963, 1976, and 1986, and a minor eruption in January 2006. We measured the surface displacements of the volcano by radar interferometry and GPS before and after the eruption in 2006. ERS-1/2, RADARSAT-1 and ENVISAT SAR data were used for the study. Multiple interferograms were stacked to reduce artifacts caused by different atmospheric conditions. Least square (LS) method was used to reduce atmospheric artifacts. Singular value decomposition (SVD) method was applied for retrieval of time sequential deformations. The observed surface displacements from satellite radar interferometry were compared with GPS data. Satellite radar interferometry helps to understand the surface displacements system of Augustine volcano.

  • PDF

Experimental Study on the Behaviore of Anchorage for Externally Prestressed CFRP Laminate (외부긴장 보강을 위한 CFRP 판의 정착부 거동 실험)

  • You Young-Jun;Park Jong-Sup;Park Young-Hwan;Jung Woo-Tai;Kang Jae Yun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.17-20
    • /
    • 2004
  • FRP strengthening system that bonds FRP sheet or laminate underneath structure has been used popularly thesedays. The failure of this bonding system occurs mainly at the interface of bonded surface abruptly. So it is difficult to expect the failure and FRP can't show its full material capacity that makes it uneconomically. By that reason, KICT proposed a system to install FRP aminate to structure for strengthening not by bondging but by unbonding. It is to install both ends of FRP laminate by anchoring underneath structure without bonding. Then, the failure is not an interfacial problem any more, it is governed by mechanical anchoring. This paper includes an experimental study about anchoring system for prestressing CFRP laminate.

  • PDF

Alignment error analysis of KAL KE007 inertial navigation system

  • Park, Chan-Ung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.564-566
    • /
    • 1992
  • It is tragic that the Korean Airline Boing 747, KE007, wandered hundreds of miles off course into Soviet airspace and was shot down on September 1, 1983. The exact cuases are not known yet. Thus, speculation centers on human error or faulty procedure of three Litton LTN-72R inertial navigation systems(INS) with which the KAL KE007 was equipped. The inertial platform must be aligned before the INS can be used as a precision inertial navigation system. This analysis checks a possibility that the navigation errors are caused by a wrong INS alignment procedure assuming it is done at Anchorage. Possible causes for the navigational position error, such as alignment errors and gyro drift errors, are analyzed through inertial navigation system error prapagation simulations. A set of misalignment angle is estimated to determine what degree of alignment errors are required to cause the navigation error assuming that the accident is caused by the INS misalignment.

  • PDF

The Analysis of Prying Action for Equipment Anchor System. (기기 기초 시스템의 지렛대 효과 해석)

  • 김강식;유원진;김갑순;서용표
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.83-90
    • /
    • 2002
  • Prying action caused by the eccentric loads within the equipment itself and the anchors can result in a lack of adequate stiffness and strength within the equipment and in additional moment loadings on the anchors. A typical case of prying action often found in power plants is the angle type anchorage system with expansion bolt. Experimental and analytical studies were performed to investigate the relationship between the amplification factors and various geometrical and material factors. It is revealed that the value of the factor is effected by the stiffness of bolt and angle, lateral stiffness of cabinet, and geometrical parameter of anchor system.

  • PDF

A study of static designation in asynchronous sensor systems (비동기 센서 네트워크에서 정적 지정에 대한 연구)

  • Park, Sangjoon;Lee, Jongchan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.251-252
    • /
    • 2020
  • 본 논문에서는 무선 센서 네트워크에서 이동 싱크에 대한 앵커리지 시스템 지정 방안을 고려한다. 동기식 이동 방식의 경우 싱크 시스템의 진입 지점이 노출되어 정보 제공에 대한 주기가 결정될 수 있지만, 비동기식의 경우 이동 싱크 시스템의 진입 지점이 각기 달라질 수 있기 때문에 이에 대한 대응 방안이 고려되어야 한다. 본 논문에서는 싱크 시스템에 의한 정적 지정방식을 고려하여, 앵커리지 시스템을 지정하는 방안을 제안한다.

  • PDF

Antifouling Effect of an Ultrasonic System Operating at Different Frequencies (주파수 변동에 따른 초음파방오장비의 파울링제거효과)

  • Bae, Jin-Woo;Park, Guan-Sik;Ru, Myung-Lok;Park, Goun-Ha
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.609-616
    • /
    • 2019
  • When the fouling of a vessel occurs, its resistance at sea increases and there is a corresponding increase in fuel consumption. The maintenance cost of the vessel also increases because it is time-consuming to remove the fouling. To solve this problem and minimize environmental contamination of sea-water, there have been recent developments in anti-fouling paints as self-polishing copolymers that not include toxic elements such as tin. When these conventional techniques are applied to vessels, polishing is promoted during the operation whereby friction or vibration with seawater occurs. This leads to enhanced anti-fouling performance. However, when fouling is intensified such as during an anchorage, there is no flow of seawater and polishing is suppressed. This leads to a deterioration of the performance of anti-fouling. To solve these problems, we developed a system that induces vibration in a vessel during anchorage. As such, the deterioration of polishing due to insuf icient flow of seawater is inhibited. The reliability of the ultrasonic antifouling system was evaluated by calculating its repeatability. The removal efficiency of fouling of the proposed system was qualitatively evaluated using test specimens. The test revealed that the value of the coefficient of variation for the reproducibility of the frequency and amplitude was 0.2 % and 4.0 % on average. The degree of fouling of the specimens was the highest at 73.3 g in the No.5 sepcimen. Moreover, efficiency of fouling removal was 93.2 % on average compared to the specimens without the proposed system.

The Effect of Anchorage with Shear Reinforcement in Flat Plate System (플랫 플레이트 구조에서 전단보강체의 정착성능에 따른 전단보강효과)

  • Choi, Chang-Sik;Bae, Baek-Il;Choi, Yun-Cheul;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.667-675
    • /
    • 2012
  • Flat plate are being used more in buildings requiring a high level of technical installations or in buildings needing changeable room arrangements during their life time such as office buildings. The main problem in flat plate is its weak resistance against a punching failure at its slab-column connections. Therefore, in this research, an experimental study on full-scale interior slab-column connection was performed. Three types of shear reinforcements were tested to prevent brittle punching shear failure that could lead to collapse of the structure. A series of four flat plate specimens including a specimen without shear reinforcement and three specimens with shear reinforcements were tested. The slabs were tested up to failure using monotonic vertical shear loading. The presences of the shear reinforcements substantially increased punching shear capacity and ductility of the interior slabcolumn connections. The test results showed that a slab that did not have enough bond length failed before shear reinforcement yielded due to anchorage slip. Also, FEM analyses were performed to study an effect of slab thickness and concrete compressive strength on the flat plate slab. The analytical study results were used to propose a method to calculate performance capacity of shear reinforcement in slab-column connection.

A Study on ship's routing system in the approach waters of Wan-do Port (완도항 인근수역 해상교통 시스템 개선 연구)

  • Im, Nam-Kyun;Jeong, J.Y.;Choi, M.S.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.175-180
    • /
    • 2007
  • Until a recent date Wan-do Port have been made efforts to advance its marine policy toward the base of marine distribution industry. Therefore the administration of Wan-do port have been carried out many projects on improvements of harbour system very actively. The improvement of ship traffic system would be one of them. This research examined the general view of present situations of marine traffic system in Wan-do waters area and suggested improvements in ship route and anchorage.

  • PDF

A cone-beam computed tomography study on strategic uprighting of mandibular molars using a biocreative reverse curve system

  • Kim, Jae-Woo;Choi, Jin-Young;Kim, Min-Ji;Bin, Xu;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.52 no.5
    • /
    • pp.354-361
    • /
    • 2022
  • Objective: To analyze the overall treatment effects in terms of the amount of uprighting with changes in the three-dimensional positions of the mandibular posterior teeth after applying the biocreative reverse curve (BRC) system. Methods: Thirty-four patients (mean age, 20.5 ± 8.56 years) were treated using the BRC system (mean period, 8.17 ± 2.19 months). Cone-beam computed tomography was performed before treatment and after treatment with the BRC system. The three-dimensional movement of each tooth was analyzed in the coordinate system at points on the crown and root apex. A paired t-test was used to analyze the treatment effects of the BRC system. Results: The application of the BRC system spanning from the first premolar to the second molar resulted not only in buccal and distal uprighting, but also in increased buccal and distal tipping of the teeth. The premolars and the first molar were extruded, and the second molar was intruded. Conclusions: When the BRC system is applied, simultaneous distal and buccal uprighting of the premolars and molars can be achieved bilaterally using a temporary skeletal anchorage device without unnecessary movement of the anterior teeth.

Behavior of Large Sized Anchorage System under Shear Loads (직매형 대형매입앵커의 전단거동특성)

  • Kim, Kang-Sik;Kwon, Ki-Joo;Shin, Sung-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.87-88
    • /
    • 2009
  • In this research project, 24 tests are performed to find out a behavior and shear breakout capacity of large anchor system exceeding 2 inch(50mm) in anchor bolt diameter($d_0$) and 25 inch(635mm) in effective embedment($h_{ef}$) not addressed by ACI 349-01 Appendix B (ACI 349 2001). On this report, analysis results are presented that this variables influence on behavior and shear breakout strength through those of test results.

  • PDF