• Title/Summary/Keyword: Anatomical structures

Search Result 312, Processing Time 0.023 seconds

Patient Setup Aid with Wireless CCTV System in Radiation Therapy (무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발)

  • Park, Yang-Kyun;Ha, Sung-Whan;Ye, Sung-Joon;Cho, Woong;Park, Jong-Min;Park, Suk-Won;Huh, Soon-Nyung
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.300-308
    • /
    • 2006
  • $\underline{Purpose}$: To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. $\underline{Materials\;and\;Methods}$: In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal (${\sim}2.4\;GHz$ and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images to investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. $\underline{Results}$: More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of $1.5{\pm}0.7\;mm$ with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ${\sim}0.17\;sec$. $\underline{Conclusion}$: The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

Primary Radiotherapy of Oropharyngeal Carcinoma : Experience in Korea Cancer Center Hospital (1980. 1-1986. 12) (구강인두 종양의 방사선 치료 성적)

  • Park Young Hwan;Park Woo Yoon;Cho Chul Koo;Koh Kyung Hwan;Yoo Seong Yul;Shim Yoon Sang;Oh Kyoung Kyun;Lee Yong Sik
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.189-198
    • /
    • 1990
  • Sixty-six patients with squamous cell carcinoma of the oropharynx were treated with radiation therapy and retrospectively analyzed to evaluate the treatment result in the Department of Therapeutic Radiology, Korea Cancer Center Hospital between January 1980 and December 1986. There were 42 patients with carcinoma of the tonsil including the fossa and pillar, 9 patients with carcinoma of the base of tongue,12 patients with carcinoma of the soft palate, and 3 patients with carcinoma of the posterior and lateral pharyngeal walls. Considering all oropharyngeal sites of involvement together, response rates for T1, T2, T3, and T4 were 80%, 77%, and 40%, respectively, with a overall response rate of 70%. The response rate for N1, N2, and N3 were 69%, 63%, and 40%, respectively, with the overall regional response rate of 70%. In lower T status, undifferentiated carcinoma and primary tumor arising from the soft palate, higher response rates were obtained. The S year overall and disease-free survival rate were 56%, 55%, respectively. A better prognosis was obtained in early T stage (T1+T2) (p<0.01) and in patients without tumor extension into adjacent structures in carcinomas arising from tonsillar area (p<0.01). Through this study we suggest that, in terms of anatomical and functional preservation, radiation therapy seems to be an effective method for the primary treatment of patients with oropharyngeal carcinoma.

  • PDF

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

EMG AND CEPHALOMETRIC STUDY ON CHANCES IN UPPER AIRWAY STRUCTURES AND MUSCLE ACTIVITIES ACCORDING TO THE USE OF MANDIBULAR REPOSITIONING APPLIANCE AND BODY POSTURE IN OSA PATIENTS (폐쇄성 수면 무호흡증 환자에 있어서 하악 재위치 장치 장착과 체위에 따른 상기도 구조와 근활성도의 변화에 관한 EMG 및 두부방사선학적 연구)

  • Park, Young-Chel;Pae, Eung-Kwon;Lee, Jeung-Gweon;Lee, Jong-Suk;Kim, Tae-Kwan
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.547-561
    • /
    • 1998
  • Obstructive sleep apnea (OSA) is a disorder characterized by repetitive episode of upper airway collapse during sleep. Recent studies showed that not only the anatomic factors but the physiologic factors of the upper airway also have effcts on the occurrence of apnea and that the genioglossus muscle also plays an important role in the maintenance of the upper airway. A variety of therapies were performed to treat OSA, and among them the use of mandibular repositioning appliances showed reasonable results. But there is still a lack of research on the structural and physiological mechanism upon the use of mandibular repositioning appliances. The author selected 26(male 17, female 9) OSA patients that came to the Yonsei University Dental Hospital, Department of Orthodontics, and 20 normal adults (male 10, female 10) and took cephalometric radiographs of them in a supine position before and after the placement of the mandibular repositioning appliance to see the structural changes of the upper airway and compare the therapeutic effects between the two groups. We also studied the waking genioglossus muscle activity in OSA patients and investigated the difference in the electromyogram of the genioglosssus muscle upon the change in body posture and the use of mandibular repositioning appliance. Following results were obtained. 1. Among the cephalometric measurements of the upper airway structure, the length of the soft palate, maximum thickness of the soft Palate and SPAS, MAS, VAL, H-H1, MP-H showed statistically significant differences between the normal and OSA groups, but the IAS and EAS showed no statistically significant differences between the two groups. 2. In both the normal and OSA groups, as the epiglottis moved forward on wearing the mandibular repositioning appliance, the epiglottis level of the upper airway increased and the maximum thickness of the soft palate changed and the hyoid bone also moved forward, but the IAS in both groups showed various results and the effect of the mandibular repositioning appliance on the structure of the upper airway was different in the two groups. 3. Upon changing the position, the electromyogram of the genioglossus muscle showed a increasing tendency but there was no statistically significant differences, and when the mandibular repositioning appliance were worn there was a statistically significant increase in the electromyogram of the genioglossus muscle in both the upright and supine positions. The mandibular repositioning appliances not only have an effect on the anatomical structure of the upper airway but also on the physiology of the upper airway. There are different responses to the use of mandibular repositioning appliance between the normal and OSA groups therefore it could be considered to have the different physiology of the upper airway between the two groups.

  • PDF

High Resolution MR Images from 3T Active-Shield Whole-Body MRI System (3T 능동차페형 전신 자기공명영상 장비로부터 얻어진 고해상도 자기공명영상)

  • Bo-Young Choe;Sei-Kwon Kang;Myoung-Ja Chu;Hyun-Man Baik;Euy-Neyng Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.138-148
    • /
    • 2001
  • Purpose : Within a clinically acceptable time frame, we obtained the high resolution MR images of the human brain, knee, foot and wrist from 3T whole-body MRI system which was equipped with the world first 37 active shield magnet. Materials and Methods : Spin echo (SE) and Fast Spin Echo (FSE) images were obtained from the human brain, knee, foot and wrist of normal subjects using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. For acquisition of MR images of knee, foot and wrist, we employed a homemade saddle shaped RF coil. Topical common acquisition parameters were as follows: matrix=$512{\times}512$, field of view (FOV) =20 cm, slice thickness = 3 mm, number of excitations (NEX)=1. For T1-weighted MR images, we used TR = 500 ms, TE = 10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE = 108 ms. Results : Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.5T system. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter. Conclusion The present results demonstrate that the MR images from 3T system could provide better diagnostic quali\ulcorner of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods.

  • PDF

An Immunological Study Before and After Tonsillectomy (편도적출 전 후의 면역학적 연구)

  • 김순웅;윤병용;김순호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.16.2-16
    • /
    • 1982
  • The palatine tonsils which are located in entrance of digestive and upper respiratory tracts are the most important organ in anatomical and functional structures of the pharyngeal lymphatic tissues. As for function of the tonsil, there have been many suspected theories that were included hematopoietic, hormonal, digestive function and production of vitamin, entry of bacteria with other antigenous materials and defence mechanism of which has taken charge by Virchow in 1860 in past. But among these theories, in recently, defence mechanism of the tonsil was strongly accepted immunologically. For the purpose of elucidating immune response of the tonsil, the author observed serum immunoglobulin levels, peripheral total lymphocyte counts and populations of T, B and Null lymphocytes before and after tonsillectomy in 30 cases of patients with chronic tonsillitis and 29 cases of healthy controls. The results obtained were as follows; 1) Serum Ig M level was significantly higher in patient group than in control group but was not significantly different preoperative from postoperative patient group. 2) Population of T-lymphocyte more significantly decreased in patient group than in control group but it was not significantly different preoperative from postoperative patient group. 3) Population of B-lymphocyte more significiantly increased in patient group than in control group but it was not significantly different preoperative from postoperative patient group. On the basis of these results, it may be suggested that tonsil play partially a role in the immune response of human.

  • PDF

Anatomical Structures of the Aortic Root in Koreans (한국인 대동맥 근부의 해부학적 구조)

  • Kang, Min-Woong;Yu, Jae-Hyeon;Lim, Seung-Pyung;Lee, Young;Kim, Si-Wook;Kim, Su-Il;Chung, In-Hyuk;Na, Myung-Hoon
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.321-328
    • /
    • 2007
  • Background: It is very important to determine the surgical anatomy of the aortic root when performing spreading aortic root preserving heart surgery. This study focuses on the surgical aspect of the aortic root anatomy by performing dissection of Korean cadavers. Material and Method: The subjects were 62 cadavers. We measured the intercommissural distances, heights of the sinuses and the circumference of the sinotubular junction and the aortic annulus. Result: The mean age of death was 61.3 years. The intercommissural distance for the right coronary sinus was $0.73{\pm}2.23mm$, that for the non coronary sinus was $19.34{\pm}2.03mm$, and that for the left coronary sinus was $18.58{\pm}2.15mm$. The height of sinus was $20.59{\pm}2.48mm$ for the right coronary sinus, $18.61{\pm}2.26mm$ for the non coronary sinus and $17.95{\pm}19mm$ for the left coronary sinus. The circumference of the sinotubular junction was $70.73{\pm}5.94mm$ and that of the aortic annulus was $77.94{\pm}5.63mm$. There is no correlation between age and STJ, aortic annulus and the ratio of STJ of aortic annulus respectively (p=0.920, p=0.111, p=0.073). The tilting angle of the sinotubular junction and aortic annulus is from $2.03^{\circ}$ to $7.77^{\circ}$ $(mean=4.90^{\circ})$. Conclusion: The intercommissural distance and the height of the sinus were largest in the right coronary sinus, and the position of the sinotubular junction to the aortic annulus is obliquely tilted levo-posteriorly.

Canine MR Images from 3T Active-Shield MRI System (3T 능동차폐형 자기공명영상 장비로부터 얻어진 개의 자기공명영상)

  • Choe, Bo-Young;Park, Chi-Bong;Kang, Sei-Kwon;Chu, Myoung-Ja;Kim, Euy-Neyng;Lee, Hyoung-Koo;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.113-124
    • /
    • 2001
  • For veterinary imaging diagnosis, we obtained MR images of the canine brain, spine, kidney and pelvis from 3T MRI system which was equipped with the world first 3T active shield magnet. Spin echo (SE) and fast Spin Echo (FSE) images were obtained from the canine brain, spine, kidney and pelvis of normal and sick dogs using a homemade birdcage and transverse electromagnetic (TEM) resonators operating in quadrature and tuned to 128 MHz. In addition, we employed a homemade saddle shaped RF coil. Typical common acquisition parameters were as follows: matrix=512$\times$512, field of view (FOV)=20cm, slice thickness=3 w, number of excitations (NEX)=1. For T1-weighted MR images, we used TR=500 ms, TE=10 or 17.4 ms. For T2-weighted MR images, we used TR=4000 ms, TE=108 ms. Signal to noise ratio (SNR) of 3T system was measured 2.7 times greater than that of prevalent 1.57 system. The high resolution images acquired in this study represent more than a 4-fold increase in in-plane resolution relative to conventional images obtained with a 20 cm field of view and a 5 mm slice thickness. MR images obtained from 3T system revealed numerous small venous structures throughout the image plane and provided reasonable delineation between gray and white matter The present results demonstrate that the MR images from 3T system could provide better diagnostic quality of resolution and sensitivity than those of 1.5T system. The elevated SNR observed in the 3T high field magnetic resonance imaging can be utilized to acquire images with a level of resolution approaching the microscopic structural level under in vivo conditions. These images represent a significant advance in our ability to examine small anatomical features with noninvasive imaging methods. Moreover, MRI technique could begin to apply for veterinary medicine in Korea.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Leaf epidermal structure of the Allium L. and its taxonomic significance (부추속(Allium L.) 잎 표피의 구조와 이의 분류학적 중요성)

  • Choi, Hyeok-Jae;Jang, Chang-Gee;Ko, Sung-Chul;Oh, Byoung-Un
    • Korean Journal of Plant Taxonomy
    • /
    • v.34 no.2
    • /
    • pp.97-118
    • /
    • 2004
  • A comparative anatomical and ultrastructural study was undertaken to investigare on the leaf epidermis by light microscopy (LM) and scanning electron microscopy (SEM). On the basis of results from this study, it was grasped major characters of taxa and variation range of each character on the level of species, section and subgenus respectively. The shape of leaf epidermal cell was oblong to linear, which was varied by each taxon. Epidermal cell of taxa in sects. Microscordum, Anguinum, and Rhizirideum, which had wide leaf blade, oblong instead of linear shape in others examined taxa in this study. The leaf of taxa in sect. Anguinum was hypostomatic, while the rest of taxa had amphistomatic leaf. This was also one of characters which could discriminate taxa of sect. Anguinum from others. The guard cell in investigated taxa had not so much variation in the respect of its size. The number of stomata per unit area reduced by increasing size of epidermal cell, the fewest number of stomata per unit area was found in the taxa of sect. Anguinum. The type of stomatal apparatus of observed all taxa was anomocytic. It was found to know ultrastructural variation in the epidermal cell, like as patterns of sculpture on the cell wall, and features of deposition of wax by SEM. There were no depositions of wax in the taxa of sect. Microscordum and Anguinum, but fine thread-like structures which were parallel or cross to axis was found on the surface of epidermal cell respectively. The patterns of sculpture on the cell were prominent straight in sects. Recticulato-bulbosa and Rhizirideum, discontinuous line in the sect. Oreiprason. The epicuticular wax had been deposited on the surface of its epidermal cell in all taxa except sects. Microscordum and Anguinum.