• 제목/요약/키워드: Anatomical Reconstruction

검색결과 218건 처리시간 0.031초

유리 견갑 피판 이식술 (Scapular Free Flap)

  • 정덕환;한정수;임창무
    • Archives of Reconstructive Microsurgery
    • /
    • 제5권1호
    • /
    • pp.24-34
    • /
    • 1996
  • There are many kinds of free flaps for management of extensive soft tissue defect of extremities in orthopaedic field. Free vascularized scapular flap is one of the most useful and relatively easy to application. This flap has been utilize clinically from early eighties by many microsurgical pioneers. Authors performed 102 cases of this flap from 1984 to 1995. We have to consider about the surgical anatomy of the flap, technique of the donor harvesting procedures, vascular varieties and anatomical abnormalities and success rate and the weak points of the procedure. This flap nourished by cutaneous branches from circumflex scapular vessels emerges from the lateral aspect of the subscapular artery 2.5-5cm from its lateral origin passing through the triangular space(bounded by subscapularis, teres minor, teres major, long head of triceps). The terminal cutaneous branch runs posteriorly around the lateral border of the scapular and divided into two major branches, those transeverse horizontally and obliquely to the fascial plane of overlying skin of the scapular body. We can utilize these arteries for scapular and parascapular flap. The vascular pedicle ranged from 5 to 10 cm long depends on the dissection, usually two venae comitantes accompanied circumflex scapular artery and its major branches. The diameter of the circumflex scapular artery is more than 1mm in adult, rare vascular variation. Surgical techniques : The scapular flap can be dissected conveniently with prone or lateral decubitus position, prone position is more easier in my experience. There are two kinds of surgical approaches, most of the surgeon prefer elevation of the flap from its outer border towards its base which known easier and quicker, but I prefer elevation of the flap from its outer border because of the lowering the possibilities of damage to vasculature in the flap itself which runs just underneath the subcutaneous tissue of the flap and provide more quicker elevation of the flap with blunt finger dissection after secure pedicle dissection and confirmed the course from the base of the pedicle. There are minimal donor site morbidity with direct skin closure if the flap size is not so larger than 10cm width. This flap has versatility in the design of the flap shape and size, if we need more longer and larger one, we can use parascapular flap or both. Even more, the flap can be used with latissimus dorsi musculocutaneous flap and serratus anterior flap which have common vascular pedicle from subscapular artery, some instance can combined with osteocutaneous flap if we include the lateral border of the scapular bone or parts of the ribs with serratus anterior. The most important shortcoming of the scapular free flap is non sensating, there are no reasonable sensory nerves to the flap to anastomose with recipient site nerve. Results : Among our 102 cases, overall success rate was 89%, most of the causes of the failure was recipient site vascular problems such as damaged recipient arterial conditions, and there were two cases of vascular anomalies in our series. Patients ages from 3 years old to 62 years old. Six cases of combined flap with latissimus dorsi, 4 cases of osteocutaneous flap for bone reconstruction, 62 parascapular flap was performed - we prefer parascapular flap to scapular. Statistical analysis of the size of the flap has less meaningful because of the flap has great versatility in size. In the length of the pedicle depends on the recipient site condition, we can adjust the pedicle length. The longest vascular pedicle was 14 cm in length from the axillary artery to the enter point cutaneous tissue. In conclusion, scapular free flap is one of the most useful modalities to manage the large intractable soft tissue defect. It has almost constant vascular pedicle with rare anatomical variation, easy to dissect great versatility in size and shape, low donor morbidity, thin and hairless skin.

  • PDF

한국인의 슬관절에 위치한 신경-혈관 다발의 해부학적 위치: 자기공명영상 연구 (Anatomic Localization of Neurovascular Bundle at the Level of the Korean Knee Joint: A Magnetic Resonance Imaging Study)

  • 김영진;김태균;양환덕;김형준;심성우
    • 대한관절경학회지
    • /
    • 제12권2호
    • /
    • pp.102-106
    • /
    • 2008
  • 목적: 자기공명영상을 이용하여 한국인 슬관절 부위에 위치한 신경-혈관 다발의 해부학적 위치를 연구하여 슬관절의 관절경 수술 시에 발생하는 신경-혈관 다발 손상의 발생을 예방하고자 하였다. 대상 및 방법: 100례의 한국인 슬관절에 대한 자기공명영상 축스캔에 횡축과 중앙축을 그려서 신경-혈관 다발과 중앙축의 거리를 측정하였고, 성별과 좌, 우측을 구분하여 분석하였다. 통계학적인 검증은 SPSS(ver. 10.1)을 이용하였고, 성별의 차이는 t-test를, 좌, 우측 위치에 따른 차이는 paired t-test를 이용하여 유의 수준 0.05에서 판정하였다. 결과: 한국인 슬관절의 신경-혈관 다발은 94례에서 중앙축의 외측에 위치하였고, 중앙축에 6례 위치하였고, 중앙축의 내측에는 한례도 관찰되지 않았다. 성별과 좌-우측 에 대한 비교 연구에도 통계학적으로 특별한 차이가 없었다(P>0.05). 결론: 관절경을 이용한 후방십자인대 재건술이나 연골판의 후각부 수술 시에 자기공명영상으로 신경-혈관 다발의 위치를 미리 파악하여, 중심축에 있다면 신경-혈관 다발의 손상에 대해서 주의가 요하리라 사료된다.

  • PDF

사진 주사(走査)를 이용한 치과용 모형재의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF DENTAL CAST AND DIE MATERIALS USING PHOTO-SCANNING)

  • 양성욱;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.320-334
    • /
    • 1996
  • Dental cast and die materials are essential material using in almost dental prsthodontic procedure and it's most important requirement is accuracy for reqorducing the oral anatomical structures. In this study, 5 abutments A, B, C, D, E were fabricated on the metal master model to simulate the arch form and specimens were poured with 4 cast materials. Inter-abutment distances, A-B, A-C, A-D, A-E, B-C, B-D were calculated using the photo-scanning and the deviations from the metal master model were also evaluated. The results were as follows; 1. The distance between A-B, A-C, A-D, A-E, B-C, B-D of the abutments A, B, C, D, E of each cast material was calculated. And after comparing the deviations between the metal master model. $Fujirock^{(R)}$ showed the lowest value with $0.20{\pm}0.22mm$, and the deviation increased in the order of $Suprastone^{(R)}$, Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Epoxy $Die^{(R)}$, Die $Keen^{(R)}$. 2. In each calculation area, the difference in measurements between cast material and metal master model showed singificant difference between A-B and Cross arch measure-ments of A-D, B-D, A-E(p<0.05). 3. The difference in measurements between cast material and metal master model in the A-B area showed $Fujirock^{(R)}$ to be the lowest with $0.05{\pm}0.04$mm and increased in the order of Die $Keen^{(R)}$, $Suprastone^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and $Suprastone^{(R)}$, Epoxy $Die^{(R)}$ (p<0.05). 4. The difference in measurements between cast material and metal master model in the B-C area showed $Fujirock^{(R)}$ to bo the lowest with $0.17{\pm}0.11$mm and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$, Epoxy $Dies^{(R)}$. There was significant difference between $Fujirock^{(R)}$ and Die $Keen^{(R)}$, Epoxy $Die^{(R)}$(p<0.05). 5. The difference in measurements between cast material and metal master model in the B-D area showed $Fujirock^{(R)}$ to bo the lowest with $0.13{\pm}0.07$mm, Epoxy $Dies^{(R)}$and increased in the order of $Suprastone^{(R)}$, Die $Keen^{(R)}$. There was significant difference between $Fuji-rock^{(R)}$ and Die Keen(p<0.05). 6. In this experiment, Epoxy $Dies^{(R)}$ showed mean contraction in every calculation area. And when reconstruction cross arch restorations it is thought that distortion should be considered in every cast material.

  • PDF

견봉쇄골 관절탈구의 수술적 치료의 비교 (A Clinical Analysis of Acute Acromioclavicular Dislocation)

  • 김영규;이범구;문도현;고진홍;이수찬;박홍기;최상규
    • Clinics in Shoulder and Elbow
    • /
    • 제1권1호
    • /
    • pp.26-34
    • /
    • 1998
  • The management of acute acromioclavicular dislocations has usually followed the accepted principles of obtaining an anatomical reduction of the joint and maintaining it until soft tissue healing has occurred. So, the preferred treatment for acute acromioclavicular dislocation is controversial. We analysed operatively treated twenty-eight cases for acute acromioclavicular dislocation between February 1994 and January 1997 and reviewed postoperatively to evaluate the results of three different methods. We collected retrospectively the data via clinical history, associated injury, type of injury, radiographic review, Taft score, and final results. Follow up time averaged 14 months. (range, 12 to 21 ) In according to Rockwood's classification, ]7 cases were type Ⅲ, 1 case was type IV, and 10 cases were type V. Ten cases were treated with the modified Phemister method, ten cases with the modified Bosworth method and eight cases with the modified Weaver-Dunn method. ]n patients treated by modified Phemister method, the Taft score was 9.4 points and 8 cases achieved good or excellent results. In patients treated by modified Bosworth method, the Taft score was 9.8 points and 8 cases achieved good or excellent results. In patients treated by modified Weaver-Dunn method, the Taft score was 10.3 points and 7 cases achieved good or excellent results. The overall Taft score was 9.9 points and 23 cases achieved good or excellent results. There were four complications, such as calcification or metallic loosening or breakage of K-wire, but did not influence late results. In conclusions, there was no significant difference of results regarding the different three methods. However, our results indicated that the coracoclavicular ligament reconstruction by transfer of coracoacromial ligament produced better results.

  • PDF

폐쇄성 혈관 질환을 가진 환자의 고식적 치료에 관한 임상적 고찰 (Clinical Analysis of Palliative Treatments in Occlusive Vascular Disease)

  • 김학제;조원민;류세민;황재준;송영상;최영호
    • Journal of Chest Surgery
    • /
    • 제35권4호
    • /
    • pp.283-289
    • /
    • 2002
  • 배경: 폐쇄성 혈관 질환을 가진 환자에서 폐쇄된 혈관 자체의 문제를 해부학적으로 해결하기에는 환자의 상태나 병변의 종류, 수술 위험도 등이 문제가 된다. 이때 환자의 연령이나 상태에 따라 선택할 수 있는 고식적인 치료 방법으로 extra-anatomic bypass나 교감신경 절제술 등이 있다. 우리는 이러한 고식적 치료의 장기 성적과 적응증에 관하여 관찰하고자 하였다. 방법: 1996년부터 2000년까지 고식적 치료가 필요했던 폐쇄성 혈관 질환을 가진 38명의 환자를 대상으로 수술의 결과를 후향적으로 고찰하였다. 남자가 32명, 여자가 6명 이었으며 평균 연령은 60.37$\pm$17.65세이다. 이 중 원인 질환으로는 동맥경화증이 32명으로 가장 많았으며, Buerger씨 병이 4명, Raynaud씨 증후군과 상대정맥 증후군이 각각 1명씩이었다. 결과: 수술은 extra-anatomic bypass가 40회, 요추 교감신경 절제술이 17회, 혈전제거술이 7회, 대퇴동맥 혈관 간치술이 1회 등이었고, 혈관 우회술 없이 요추 교감신경 절제술 혹은 혈전 제거술만을 시행한 환자는 7명이었다. 수술 후 6명에서 재수술이 필요하였는데, 이 중 5명은 원위부 혈류 폐쇄 혹은 약화로 발목 관절이나 족지 절단 혹은 요추 교감신경 절제술을 시행한 경우이었고, 1명은 혈관 우회술 1달 후에 인조혈관 원위부의 동맥류가 발생하여 다시 우회술이 필요한 경우였다. 폐쇄성 혈관 질환에 대한 고식적 치료 3년 후의 1차 혈관 개통률은 78.29 $\pm$ 3.81%이었으며, 수술 방법과 혈관 개통률 사이의 통계적 유의성은 없었다. 결론: 여러 논란에도 불구하고 폐쇄성 혈관 질환 환자의 일부에서는 여러 고식적 수술이 이루어지는데, 적절한 환자의 선택과 수술 전후의 적절한 환자 교육, 추적 관찰이 이루어진다면 좋은 결과를 얻을 수 있을 것으로 생각된다.

PET/CT 장치의 감마선 검출과정 (Gamma Ray Detection Processing in PET/CT scanner)

  • 박성옥;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.125-132
    • /
    • 2006
  • SPECT camera와 PET scanner 그리고 PET/CT 장치는 감마선을 검출하여 얻어진 자료(data)를 정보화 한다. 특히 PET/CT 장치는 PET영상에서 나타나는 해부학적 불선예함을 CT로 보완하여 선예한 해부학적 구조의 영상 묘출능력이 뛰어나 양질의 진단정보를 제공하고 있게 되었다. 신속 정확한 자료의 획득과 정보화를 위하여 우선적으로 검출기(detector)에서의 효율적인 감마선검출은 매우 예민하고 중요한 역할 중의 하나이다. 섬광체(scintillator)의 개발과 함께 data 처리를 위한 software의 발전은 영상재구성처리시간의 단축은 물론 영상의 질적인 향상을 초래하였다. PET scanner에서는 SPECT camera의 $100{\sim}200\;keV$와는 달리 511 keV의 고에너지 감마선을 검출한다. 섬광체 GSO, LSO는 PET scanner의 섬광체로 비교적 많이 이용되고 있다. 고에너지 감마선에너지를 빛으로 전환하여 여러 단계를 거쳐 정보화하는 과정은 결과적으로 고화질의 영상을 비롯한 정확하고 신속한 진단정보획득에 목적을 두고 있다. 화질의 질적향상은 획득한 정보량에 대한 영상의 재구성 방법과 기술에 따라 영향을 받는다. 본 연구는 PET/CT 장치에서 특히 PET부분에서 섬광체(scintillator)의 특성과 감마선의 검출과정에서부터 영상 재구성단계까지 문헌적 고찰을 통하여 요약 설명하였다.

  • PDF

핵의학 영상 물리 및 기기의 최신 동향 (Current Status of Imaging Physics & Instrumentation In Nuclear Medicine)

  • 김희중
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.83-87
    • /
    • 2008
  • 지난 몇 년 동안 핵의학 영상 물리 및 기기 관련 융합영상기기 분야에 많은 발전이 있었다. 최근 몇 년 동안 국내 PET/CT 설치의 급속한 증가는 이들의 임상에서의 역할 및 그 중요성을 입증하고 있다. 그러나 PET/CT는 고가이고, 임상적으로 아직도 그 유용성이 입증되는 과정에 있으며, 특히 치료계획을 위한 장비로는, 미국의 경우 다소 많이 설치되었다는 평가가 공존하고 있다. 또한 저가로 해 결할 수 있는 소프트웨어 융합도 가능하기 때문에 PET 대신 반드시 PET/CT가 필요하다는 주장에는 위의 관점에서 그 한계가 있을 수 있다. 그림에도 불구하고 PET/CT 설치는 계속 증가하고 있어 영상획득 또는 영상판독 모두 PET과 CT 분야의 훈련과 교육이 매우 중요하며 이에 대한 지침서가 발간되었다. PET/CT에 비하여 SPECT/CT는 발전속도가 다소 떨어지지만 이에 대한 지침서도 발간되었다. PET/CT와 SPECT/CT 모두 CT는 앞 부분에 PET과 SPECT는 뒷부분에 설치된다. 이는 환자 영상을 얻을 때 동시에 얻는 것이 아니고 CT영상을 얻은 후 PET과 SPECT영상을 얻게되는 단점이 있다. 이와는 달리 MRI/PET경우 뇌영상을 얻을 때 동시에 MRI와 PET영상을 얻을 수 있어 뇌영상 연구에 큰 도움이 될 것으로 예상하고 있다. 앞으로 기술이 발전함에 따라 전신용 MRI/PET과 유방영상을 위한 PET/US 융합영상장치의 개발 가능성이 매우 높다. 이와 함께 SPECT/CT, PET/CT 및 MRI/PET 기기의 발전도 계속될 것으로 판단된다. 핵의학 영상 물리 및 기기 분야는 최첨단 융합영상 장치의 개발과 함께 하드웨어, 소프트웨어 물리적 특성에 대한 보정기술, 영상 재구성 분야의 다양한 연구도 많은 진전이 필요하다. 또한 영상기기의 설계 및 정량화 기법을 연구하기 위한 몬테카를로 시뮬레이션, 영상장비의 성능평가, 동력학 분석, 선량평가, 움직임 보정 및 융합영상의 정량화 및 분석 기법에 대한 연구도 더욱 활발히 진행될 것으로 예측된다.

외측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술술기 - (Arthroscopic All Inside Repair of Lateral Meniscus Root Tear -Technical note-)

  • 안진환;이동훈;장문종
    • 대한관절경학회지
    • /
    • 제11권1호
    • /
    • pp.63-68
    • /
    • 2007
  • 목적: 전방 십자 인대 손상과 동반된 외측 반월상 연골 경골 후방 부착부 완전 방사상 파열 환자에서 전외측 및 전내측 도달법을 통한 all-inside 봉합 술기를 시술하여 온 바, 이를 소개하고자 한다. 수술 술기: 관절경을 전내측 도달법으로, 봉합용 갈고리(suture hook, $Linvatec^{TM}$, Largo, Florida, USA)를 전외측 도달법으로 관절에 삽입한 상태에서 봉합용 갈고리를 틀어서 외측으로 전위된 외측 반월상 연골 후각부 파열단의 대퇴골측 면에서 경골측 면으로 수직으로 통과시킨다. 갈고리 내로 PDS No. 1 ($Ethicon^{TM}$, Somerville, NJ, USA)를 통과시킨 후 봉합용 갈고리를 빼내고 전외측 도달법 입구로 봉합사의 양끝을 뽑아낸다. MAXON 2-0 ($Syneture^{TM}$, Norwalk, Connecticut, USA)를 봉합용 갈고리를 이용하여 경골 부착부 파열단 경골측 면에서 대퇴골측 면으로 봉합사를 수직으로 통과시켜 양끝을 전외측 도달법 입구로 빼내어 두 봉합사의 경골 측 끝 중 PDS를 MAXON에 결찰하여 MAXON의 대퇴골측 끝을 전외측 도달법으로 당겨 이를 PDS로 교체한 뒤 SMC(Samsung Medical Center) knot를 이용하여 결찰한다. 결론: 본 술기를 시행하여 외측 반월상 연골 후방 부착부 파열을 해부학적으로 봉합할 수 있으며 또한 반월상 연골의 연골 장력(hoop tension)을 효과적으로 회복시켜 줄 수 있을 것으로 생각된다.

  • PDF

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • 제50권3호
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Ebstein 기형의 외과적 치험 (Surgical Treatment of Ebstein Anomaly)

  • 이종호;김병렬
    • Journal of Chest Surgery
    • /
    • 제32권1호
    • /
    • pp.5-9
    • /
    • 1999
  • 배경: Ebstein 기형은 삼첨판, 우심실 및 우심방의 특징적인 변형을 보이는 희귀한 선천성 심질환이다. 이 질환의 외과적인 치료는 삼첨판성형술과 판막치환술로 두가지가 시행되고있으나 가장 좋은 술식에 대해서는 의견이 일치되고 있지는 않다. 대상 및 방법: 본원에서 1984년 1월부터 1996년 12월까지 Ebstein기형의 수술적 교정을 한 8례를 대상으로 하였으며 대상 환자의 연령 및 성별분포, 임상증상, 흉부 방사선학적 소견, 술전 검사소견, 수술소견, 수술방법, 수술 결과등을 비교검토하였다. 결과: 성비는 남자 5명, 여자 3명이었고, 연령분포는 최소 2세에서 최고 28세로 평균연령은 17.6세였다. 모든예에서 전형적인 삼첨판의 변형을 보였으며 동반된 심기형으로는 개방성 난원창, 심방중격 결손증, 폐동맥 협착증이 있었다. 수술적 방법으로는 삼첨판막 치환술과 삼첨판륜 성형술 및 주름 성형술을 각각 4례씩 실시하였다. 술후 합병증으로 Danielson 술식을 받은 2례에서 빈맥이 있었으며 삼첨판 치환술을 받은 2례에서 완전 방실차단이 생겨 인공심박동기를 설치하였다. 2례의 술후 사망례가 있었으며 생존한 6례에서는 술후 평균 64.83 개월간 추적 관찰결과 NYHA class I-II로 별문제 없이 지내고 있고 술전보다 양호한 심기능을 보였다. 술후 5례에서 심초음파를 실시하였고 삼첨판의 역류정도는 술전 중등도이상에서 술후 경증도로 개선되었다. 결론: Ebstein 기형의 수술적 방법의 선택은 각환자의 해부학적 특성에 따라 다르지만, 삼첨판의 기형과 변형이 작고 판막치환이 필요하지않다면 삼첨판륜성형과 주름성형술이 좋은 술식이라고 판단된다.

  • PDF