• Title/Summary/Keyword: Anatomical Landmarks

Search Result 92, Processing Time 0.024 seconds

New insight into the vasto-adductor membrane for safer adductor canal blockade

  • Yanguk Heo;Miyoung Yang;Sung Min Nam;Hyun Seung Lee;Yeon-Dong Kim;Hyung-Sun Won
    • The Korean Journal of Pain
    • /
    • v.37 no.2
    • /
    • pp.132-140
    • /
    • 2024
  • Background: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB). Methods: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume. Results: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery. Conclusions: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

Evaluation of Palatal Rugae Following Orthopedic Treatment Using Rapid Maxillary Expander and Facemask (구개확장장치와 facemask를 이용한 교정치료 환자의 구개주름 평가)

  • Park, Sehee;Choi, Namki;Kim, Seonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.167-175
    • /
    • 2020
  • The purpose of this study was to determine whether the palatal rugae could be used as an appropriate reference area for serial model superimposition following Rapid maxillary expansion(RME) and facemask treatment. A total of 52 pediatric patients who had undergone RME and facemask treatment were selected. Palate and palatal rugae in the pre- and post- treatment casts from the patients were measured. In spite of dentoalveolar changes occurred by RME and facemask, anteroposterior changes in palate and palatal rugae were not significant. Anatomical changes of palate and palatal rugae were mostly shown in the transverse dimension. The soft tissue of the palatal rugae stretches in adaptation to hard tissue movement. Among the evaluated landmarks, the medial point of the third palatal rugae seemed to be the most stable. The observed alterations in the palatal rugae demonstrated the potential of medial points of third palatal rugae as a reference point in model superimpositions to evaluate dental movement within the maxillary arch following RME and facemask treatment.

New Standards for Measurement in Meridians & Acupoints by Taking the Size of Normal Male Legs (정상 성인 남자(男子) 하지부위(下肢部位)의 수혈(?穴) 정위(定位)를 위한 도량형(度量衡) 산출)

  • Yu, Shin-Jong;Kwon, Oh-Sang;Ahn, Seong-Hoon;Kim, Young-Jin;Kim, Kyung-Sik;Sohn, In-Chul;Kim, Jae-Hyo
    • Journal of Pharmacopuncture
    • /
    • v.13 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Objective : Standard of measurement in Korean Medicine has been changed in dynasty and location. Thus, cun (寸) and chi (尺) as unit of measurement for meridians and acupoints could be recognized as the length of equally divided portions of a certain long bone or the distance between two anatomical landmarks and as an symbolical meaning to date. The goal of this study is to propose a new standard measurement in the metric system for the relative measurement of cun and chi as unit of measurement for meridians and acupoints in normal male legs. Methods : This study was conducted by gauging each parts of normal male legs in the metric system and comparing to the relative measurement of cun and chi as follows; to calculate 1 cun, the length of each parts was divided into the unit of cun referred to Measurement of the Bone in Neijing Lingshu (靈樞 骨度篇); it was compared the unit of cun referred to Measurement of the Bone in Neijing Lingshu with cun which was calculated by dividing subject's height into 75 cun, respectively. Result : There has no significant difference in length of 1 cun among each leg's areas based on a standard of subject's height. The unit of cun by the metric length in the legs was similar to the unit of cun referred to Measurement of the Bone in Neijing Lingshu based on each subject's height. Conclusion : It is suggested that an unit of cun as the measurement for meridians and acupoints in the male legs should be considered to the ranges from 2.4cm to 2.6cm.

Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders (운동성 장애에 대한 감마나이프 시술의 초기경험)

  • Hong, Joon Ki;Kim, Moo Seong;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF

Tc-99m EHIDA Scintigraphic Demonstrability of Biliary Elements and Liver Function Tests in Hepatobiliary Diseases (몇가지 간담도질환에서 간기능에 따른 Tc-99m EHIDA의 담도영상능)

  • Kim, Choon-Yul;Lee, Myung-Hee;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.71-80
    • /
    • 1982
  • In the present communication, the results will be reported on a clinical study of how well scintigraphic visualization of the hepatobiliary elements and several commonly used clinical liver function tests correlate each other in various diseases oft hepatobiliary system. The demonstrability of the biliary tract, gallbladder (GB) and duodenum was rather closely paralleled to serum bilirubin level and less closely to alkaline phosphatase and rather poorly to SGOT and SGPT. The biliary tree could not be visualized scintigraphically when bilirubin exceeded 10.5mg/dl. The usefulness of Tc-99m EHIDA [N-(2,6-diethylacetanilido) iminodiacetic acid, made by Amersham, England] hepatobiliary scintigraphy (Tc EHIDA HBS) in settling diagnostic controversy and ambiguity raised by oral cholecystography, intravenous cholangiography and ultrasonography in many hepatobiliary diseases is well known. The purpose of this investigation was to semiquantitatively evaluate the scintigraphic demonstrability of the hepatobiliary tract, GB and duodenum following intravenous injection of Tc-99m EHIDA in normal subjects and in patients with a disturbed liver function from various hepatobiliary diseases. The hepatobiliary scintigraphy was performed in 10 normal subjects and 39 patients with various hepatobiliary diseases (Table 1) at the Dept. of Radiology, St. Mary's Hospital Catholic Medical College, Seoul, Korea during 2 years period from September 1979. Scintigraphic examination was started at end of 3 minutes after intravenous injection of Tc-99m EHIDA in the amount of $50{\mu}Ci/kg$ and was continued until after 30 minutes at 5 minutes interval. The imaging was usually terminated when the tracer could be seen in the duodenum. Late scintigrams were obatained at 1 1/2, 3, 4 and 6 hours when reeded. Scintigrams were analyzed in terms of promptness and clarity of visualization of the biliary tree, GB and duodenum and demonstrability of these anatomical landmarks was correlated with the values of liver function tests. The demonstrability of the common hepatic duct, common bile duct, GB and duodenum was closely paralleled to the level of serum bilirubin when it is less than 10.5 mg/dl as shown in figure 1. However when the bilirubin exceeded 10.5 mg/dl the time of visualization between protracted reaching a flat curve or plateau around 10.5 mg/dl. The biliary tract could not be visualized when the bilirubin was higher than 10.5 mg/dl. The correlability between scintigraphic demonstration and serum alkaline phosphatase was less strong and between scintigraphic demonstration and SGOT and SGPT was rather poor. The present clinical study confirmed the usefulness and limitation of Tc-99m EHIDA hepatobiliary scintigraphy in visulizing and diagnosing the biliary system and duodenum when radiogrpahy and ultrasonography failed to provide useful informations. Scintigraphy was very helpful in the diagnosis of neonatal hepatitis, biliary atresia, cholecystitis and extrahepatic biliary obstruction. The hepatobiliary system and duodenum were visualized when serum bilirubin level was less than 10.5 mg/dl, SGOT 135 units, SGPT 114 units and alkaline phosphatase 52.2 KAU.

  • PDF

Development of portable digital radiography system with device for sensing X-ray source-detector angle and its application in chest imaging (엑스선촬영 각도를 측정할 수 있는 장치 개발과 흉부 X선 영상촬영에서의 적용)

  • Kim, Tae-Hoon;Heo, Dong-Woon;Ryu, Jong-Hyun;Jeong, Chang-Won;Jun, Hong Young;Kim, Kyu Gyeom;Hong, Jee Min;Jang, Mi Yeon;Kim, Dae Won;Yoon, Kwon-Ha
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.01a
    • /
    • pp.235-238
    • /
    • 2017
  • This study was to develop a portable digital radiography (PDR) system with a function measuring the X-ray source-with-detector angle (SDA) and to evaluate the imaging performance for the diagnosis of chest imaging. The SDA device consisted of an Arduino, an accelerometer and gyro sensor, and a Bluetooth module. According to different angle degrees, five anatomical landmarks on chest images were assessed using a 5-point scale. Mean signal-to-noise ratio and contrast-to-noise ratio were 182.47 and 141.43. Spatial resolution (10% MTF) and entrance surface dose were 3.17 lp/mm ($157{\mu}m$) and 0.266mGy. The angle values of SDA device were not significant difference as compared to those of the digital angle meter. In chest imaging, SNR and CNR values were not significantly different according to different angle degrees (repeated-measures ANOVA, p>0.05). The visibility scores of the border of heart, 5th rib and scapula showed significant differences according to different angles (rmANOVA, p<0.05), whereas the scores of the clavicle and 1st rib were not significant. It is noticeable that the increase in SDA degree was consistent with the increase of visibility score. Our PDR with SDA device would be useful to be applicable to clinical radiography setting according to the standard radiography guideline at various fields.

  • PDF

Surgical Repair of Inferior Sinus Venosus Defect - A Report Four Cases- (하정맥동형 심방중격결손의 외과적처지 -4례 보고-)

  • 최형호;김천석;윤향석;최종범;최순호
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.168-172
    • /
    • 1998
  • Inferior sinus venosus defect is a rare lesion in which there is a large interatrial communication adjacent to the atrial connection of the inferior caval vein. The defect is located posteriorly and inferiorly, outside the confines of the true atrial septum, and partial anomalous pulmonary venous connections are the rule. We underwent surgical repair in four patients with inferior sinus venosus defect and partial anomalous pulmonary venous return. There were three males and one female with an age range from four months to 25 years. A cross- sectional echocardiogram and cardiac catheterization had been performed preoperatively in all patients, but the correct diagnosis had been made in only one case. Surgical repair was indicated due to congestive heart failure, and one patient of 4-month-old needed urgent operation. The repair was accomplished by suturing a untreated autologous pericardial patch to the right of the pulmonary veins, so that the defect was closed and all the pulmonary venous blood was directed to the left atrium. The preoperative knowledge of the unusual anatomy allows the surgeon to repair the anomaly without difficulties. For the patients in whom interatrial communication and anomalous pulmonary venous return are suggested, surgeon has to pay careful attention to the anatomical landmarks to avoid incorrect placement of the patch.

  • PDF

Changes in atlas position with Class ll activator treatment in Class II malocclusion patients (II급 부정교합자에서 액티베이터 사용에 따른 atlas의 위치 변화에 관한 연구)

  • Cho, Moon-Ki;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.44-55
    • /
    • 2007
  • Objective: Previous studies have reported that morphological features of the first cervical vertebra (atlas) have been associated with mandibular growth direction. The purpose of this study was to show the possible positional and morphological changes of the Atlas from activator treatment in Class II malocclusion patients. Methods: Lateral cephalometric radiograph tracings were made at initial, middle and final stages of treatment. Angular and linear measurements of skeletal and morphological features were measured on the anatomical landmarks and reference planes. Results: The skeletal effects of activator treatment on Class II malocclusion patients were evident on ramal height, body length, effective body length, ANB, and overjet. Clockwise rotation of the long axis of the Atlas was found in Group 1, but there was no inclination change of the Atlas in groups 2 and 3. There was no significant correlation between anterior and posterior positions of the atlas or morphological change in all groups. - except for posterior movements of the Atlas found in group 1. Conclusion: Clockwise rotation of the atlas axis resulted from activator treatment in Cl II malocclusion patients. Change in atlas axis can be thought of as an indicator for success of activator treatment.

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.