• Title/Summary/Keyword: Anatomical Axis

Search Result 65, Processing Time 0.03 seconds

A Study on Variation Types in Celiac Axis and Superior Mesenteric Artery using 3D Volume Rendering of MDCT (MDCT의 3차원 볼륨렌더링을 이용한 복강축과 위창자간막동맥의 변위 형태에 관한연구)

  • Lee, Jeong-Keun;Jang, Young-Ill;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.131-139
    • /
    • 2013
  • The aim of this study was to evaluate the variation which based on Celiac axis and SMA using by CT volume rendering images. 613 patients underwent abdominal CTA, there were 552 patients (99.05%, TypeI, II) with normal anatomical form and 61 (9.95%, Type III~XII) with variation. TypeI was 339(55.31%), Type II was 213 (34.74%), Type III was 18 (2.93%), Type IV was 12 patients (1.95%), Type V was 11 patient (1.79%), Type VI was 9 patients (1.46%), Type VII was 6 patients (0.97%), Type VIII was 1 patient (0.16%), Type IX was 1 patient (0.16%), Type X was 1 patient (0.16%), Type XI was 1 patient (0.16%), and Type XII was 1 patient (0.16%) into totally new types of variation. In conclusion, we could found 9 new types of variation by classifying based on celiac axis and superior mesenteric artery. These results were considered to be an important opportunity for a new vessel map.

A study of incisive canal using a cone beam computed tomography (cone beam형 전산화 단층촬영장치를 이용한 절치관의 연구)

  • Kim Gyu-Tae;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • Purpose: To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. Materials and Methods: 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. Results: The mean length of incisive canal was 15.87 mm±2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm±0.76 and 3.89 mm± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3°±6.96 and 117.45°±7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r= 0.258). Conclusion : This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  • PDF

Development of Schizogenous and Lysigenous Aerenchyma in Rice Root

  • Kang, Si-Yong;Wada, Tomikichi;Choi, Kwan-Sam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 1998
  • Aerenchyma development in rice (Oryza sativa L.) roots is quite important for adaptation to waterlogged or reduced soil conditions. Anatomical observations were carried out to clarify the development of schizogenous and lysigenous aerenchyma in elongating crown roots of rice. The crown roots of 3rd and 4th phytomer were taken from rice plants of the 8th leaf stage grown by hydroponic culture. The schizogenous intercellular spaces in the cortex of crown root tip were observed using a light microscope with semi ultra-thin sections and the lysigenous aerenchyma in mature tissue of crown root were observed using a cryo scanning electron microscope (cryo-SEM) with freezing fracture method. The schizogenous intercellular spaces in the root tip exist obviously in the middle portion of cortical cell layers close to the root-root cap junction, but not in root cap, stele and outer cell layers of cortex. The air spaces were formed at the junction of four neighbouring cells of inner cortex in the transverse sections, and between longitudinal cell layer connected along the root axis. Although many of those spaces were filled with liquid, some spaces seem to exist as air spaces. The lysigenous aerenchyma in the cortex, which hardly filled with liquid, emerged at 3-4 cm segment from the root tip and increased toward the basal region of root axis. The developing process of lysigenous aerenchyma was primarily separation of a radial row of cells caused by the shrinking and collapsing of cortical cells and then formation of septa along the radial cell rows by the fusion of cell wall with each other. These results suggest that the schizogenous and lysigenous aerenchyma playa role as a passage for the movement of oxygen into the root tip region where oxygen is required for respiration.

  • PDF

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

Computerized Tomographic Measurements of Morphometric Parameters of the C2 for the Feasibility of Laminar Screw Fixation in Korean Population

  • Kim, Young-June;Rhee, Woo-Tack;Lee, Sang-Bok;You, Seung-Hoon;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.1
    • /
    • pp.15-18
    • /
    • 2008
  • Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (${\pm}1.0$) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was $43.2^{\circ}$ and mean slope angle was $32.9^{\circ}$. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.

Radiological Study of Interphalangeal Sesamoid Bones on Hallux in Korean Subjects (한국인에서 족무지 지관절의 종자골에 대한 방사선학적 연구)

  • Moon, Sang-Ho;Kim, Dong-Joon;Suh, Byoung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.242-246
    • /
    • 2006
  • Purpose: Frequency of sesamoid bone on hallucal interphalangeal joint has been described to be low probability in orthopaedic and anatomical literature. We have, however, experienced two cases of interphalangeal joint dislocation giving difficulty to usual manipulative reduction because of presence of sesamoid bone recently. In order to ascertain existence of sesamoid bone on interphalangeal joint of hallux in Korean adults, radiological study have been performed with feet of patients Materials and Methods: Between May 2003 and October 2006, 974 patients with 1098 radiographs of feet which were reached skeletal maturity over 18-year-old were examined. Unilateral or bilateral anteroposterior, lateral and oblique radiographs were observed by one same person and presence was recorded if there was sesamoid in films. Distance of long and short axes were measured in lateral view and cases of two sesamoids in interphalangeal joint were recorded. Statistical differences between left and right side or between men and women were evaluated by chi-square test. Results: Frequency of sesamoid was 980 cases (89.3%) and no occurrence in 118 cases (10.7%). Two sesamoids were observed in 3 cases. Average distance of long axis was 4.9 mm (range, 0.5-11.4) and average distance of short axis was 3.5 mm (range, 0.3-9.3). Unilateral sesamoid was observed in 7 patients (5.6%), bilateral absence was 7 patients (5.6%) and bilateral sesamoids in 110 patients (88.8%) out of 124 patients who took bilateral feet radiographs. Men has less frequency than women significantly (p=0.014) while there was no significant difference in frequency according to side(p>0.05). Conclusion: Sesamoid bone was seen in 980 feet (89.3%) out of 1098 normal Korean radiological studies of feet. We report 3 cases of two seamoids which was extremely rarely reported in literature. Korean frequency is similar with Japanese, but much higher than Caucasians and black Africans.

  • PDF

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

Diagnosis and Pathophysiology of Hallux Valgus (무지 외반증의 진단 및 병태생리)

  • Jang, Kyu-Sun;Kim, Tae Wan;Kim, Hak Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.43-47
    • /
    • 2014
  • Hallux valgus is a lateral deviation of the first phalanx and medial deviation of the first metatarsal at the first metatarsophalangeal (MP) joint. Its incidence has increased due to developing footwear. The etiologies include fashion footwear, genetic causes, anatomical abnormality around the foot, rheumatoid arthritis, and neuromuscular disorders. Physiologic alignment of the first MP joint is maintained by congruent and symmetric alignment of the articular surface of the first proximal phalanx and first metatarsal head, physiologic relationship of the distal first metatarsal articular surface and the first metatarsal shaft axis, and stable balance of soft tissue around the first MP joint and stable tarsometatarsal joint. Several factors have been associated with hallux valgus, including pes planus, hypermobility of the first tarsometatarsal joint, flattened shape of the first metatarsal head, increased distal metatarsal articular angle, and deformation of the medial capsular integrity. History and physical examination are very important to diagnosis of hallux valgus. Simple radiography provides information on deformity, particularly in weight-bearing anteroposterior and lateral radiographs. Understanding the etiologies and pathophysiology is very important for success in treatment of patients with hallux valgus.

Generation of contrast enhanced computed tomography image using deep learning network

  • Woo, Sang-Keun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.41-47
    • /
    • 2019
  • In this paper, we propose a application of conditional generative adversarial network (cGAN) for generation of contrast enhanced computed tomography (CT) image. Two types of CT data which were the enhanced and non-enhanced were used and applied by the histogram equalization for adjusting image intensities. In order to validate the generation of contrast enhanced CT data, the structural similarity index measurement (SSIM) was performed. Prepared generated contrast CT data were analyzed the statistical analysis using paired sample t-test. In order to apply the optimized algorithm for the lymph node cancer, they were calculated by short to long axis ratio (S/L) method. In the case of the model trained with CT data and their histogram equalized SSIM were $0.905{\pm}0.048$ and $0.908{\pm}0.047$. The tumor S/L of generated contrast enhanced CT data were validated similar to the ground truth when they were compared to scanned contrast enhanced CT data. It is expected that advantages of Generated contrast enhanced CT data based on deep learning are a cost-effective and less radiation exposure as well as further anatomical information with non-enhanced CT data.

Percutaneous Microwave Ablation of Desmoid Fibromatosis

  • Alberto Martinez-Martinez;Jade Garcia-Espinosa;Antonio Jesus Lainez Ramos-Bossini;Fernando Ruiz Santiago
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.944-950
    • /
    • 2021
  • Objective: To demonstrate the feasibility of percutaneous microwave ablation in desmoid fibromatosis with respect to tumor volume control and improvement in the quality of life. Materials and Methods: Twelve microwave ablations were performed in 9 patients with a histological diagnosis of desmoid fibromatosis between January 2010 and January 2019. The study population included 6 female and 3 male, with an age range of 21-76 years (mean = 46.6 years; standard deviation [SD] = 19.3 years). The mean major axis of the tumors was 10.9 cm (SD = 5.2 cm) and mean lesion volume was 212.7 cm3 (SD = 213 cm3). Their anatomical distribution was as follows: 3 lesions in the thigh, 2 in the gluteus, 2 in the leg and 2 in the periscapular region. We evaluated the reduction in tumor volume and improvement in the quality of life based on the Eastern Cooperative Oncology Group (ECOG) scale. Results: An average tumor volume reduction of 70.4% (SD = 24.9) was achieved, while the quality of life (ECOG scale) improved in 88.9% of patients. Conclusion: Percutaneous microwave ablation may potentially be a safe, effective, and promising technique for controlling tumor volume and improving the quality of life in patients with desmoid fibromatosis.