• 제목/요약/키워드: Analytical precision

검색결과 812건 처리시간 0.032초

An analytical solution to the vibration characteristics for continuous girder bridge-track coupling system and its application

  • Feng, Yulin;Jiang, Lizhong;Zhou, Wangbao;Zhang, Yuntai;Liu, Xiang
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.601-612
    • /
    • 2021
  • To study the vibration characteristics of a high-speed railway continuous girder bridge-track coupling system (HSRCBT), a coupling vibration analysis model of an m-span continuous girder bridge-subgrade-track system with n-span approach bridge was established. The model was based on the energy and its variational method, where both the interlaminar slip and shear deformation effects were considered. In addition, the free vibration equations and natural boundary conditions of the HSRCBT were derived. Further, according to the coordination principle of deformation and mechanics, an analytical method for calculating the natural vibration frequencies of the HSRCBT was obtained. Three typical bridge-subgrade-track coupling systems of high-speed railway were taken and the results of finite element analysis were compared to those of the analytical method. The errors between the simulation results and calculated values of the analytical method were less than 3%, thus verifying the analytical method proposed in this paper. Finally, the analytical method was used to investigate the influence of the number of the approach bridge spans and the interlaminar stiffness on the natural vibration characteristics of the HSRCBT based on the degree of sensitivity. The results suggest the approach bridges have a critical number of spans and in general, the precision requirements of the analysis could be met by using 6-span approach bridges. The interlaminar vertical compressive stiffness has very little influence on the low-order natural vibration frequency of HSRCBT, but does have a significant influence on higher-order natural vibration frequency. As the interlaminar vertical compressive stiffness increases, the degree of sensitivity to interlaminar stiffness of each of the HSRCBT natural vibration characteristics decrease and gradually approach zero.

마이크로 앤드밀의 가공특성분석 및 응용가공 연구 (Micro End-Mill Machining Characters and its Applications)

  • 제태진;이응숙;최두선;홍성민;이종찬;최환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.589-592
    • /
    • 2003
  • In the machining process of micros shape by using high-precision machining system and micro end-mill, it is important for machining characters of tools to be grasped in order to stably use tools of micro end-mill. In this study. we carried out an analytical experiment of basic machining features by using end-mill tools for the purpose of damage prevention and manufacture of high quality when the tools of micro end-mill are used. This experiment used a micro machining system with high precision and a variety of end-mill tools commercialized from tens to hundreds microns in diameter. To establish an optimal machining condition without tool damage, cutting force was analyzed according to the changes of tool diameter and cutting conditions such as cutting speed. feed rate, depth of cut. And an examination was performed for the shape and surface illumination of machining surface according to the changes of machining conditions. Based on these micro machining conditions, micro square pillar, cylinder shaft. thin wall with high aspect ratio, and micro 3-D structures such as micro gear and fan were manufactured.

  • PDF

초정밀 유정압 베어링 이송 테이블의 나노미터 위치결정 제어에 관한 연구 (On Nanometer Positioning Control of Ultra-precision Hydrostatic Bearing Guided Feeding Table)

  • 심종엽;박천홍;송창규
    • 한국정밀공학회지
    • /
    • 제30권12호
    • /
    • pp.1313-1320
    • /
    • 2013
  • An ultraprecision multi-axis machine tool has been designed and developed in our laboratory. The machine tool has four moving axes which are composed of three linear axes and one rotational axis. It has a gantry type structure and the Z-axis is on the X-axis and the C-axis, on which a workpiece is located, is inside the Y-axis. This paper shows control performance improving method and procedure for the ultra-precision positioning control of a hydrostatic bearing guided linear axis. Through improvements of electrical and mechanical components for the control system such as control electronics and oil pumping systems, the control disturbing noise is decreased. Also by the frequency domain analysis of control system those problem-making system components are identified and modified with analytical methods. The controller is analyzed and designed from frequency domain data and system information. In the experimental control results the nanometer order control result is successfully presented.

탄성 힌지 타입 레버 메커니즘을 이용한 자동 초점 조절 미세구동장치에 대한 연구 (A study on fine actuating stage for autofocus by using flexure-hinge type lever mechanism)

  • 이재석;홍석인;김호상;장한기;이경돈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.665-666
    • /
    • 2006
  • In precision laser microfabrication, focusing is essential to acquire good machining precision and uniform machining quality. If it does not perform, laser machining cannot be realized. So, confocal scanning method with high depth resolution is used for focus detection technique. This paper is concerned with a procedure for design, analysis and performance test of an autofocus fine actuating stage, which is composed of flexure-hinge type lever mechanism and piezoelectric actuator. Through series of analytical design, the stage is simplified as a rigid bodies(lever and main body) and springs(flexure hinges). The simplified model was applied to determine the dimension of flexure hinges and lever. After structural analysis confirmed design requirement, an actual stage was made and verified through an experiment on the static and dynamic characteristics(maximum stroke and 1st natural frequency). The fabricated stage was satisfied with the design requirement.

  • PDF

Object Precision 방법을 이용한 복합 구조물의 RCS 해석 (RCS Analysis of Complex Structures Using Object Precision Method)

  • 김국현;김진형;조대승
    • 대한조선학회논문집
    • /
    • 제42권2호
    • /
    • pp.159-164
    • /
    • 2005
  • Monostatic RCS analysis of complex structures has been done with a combined method of physical and geometric optics, commonly applied to high frequency electromagnetic backscattering problems. In the analysis, the complex structure is modeled as a number of flat surfaces and the RCS of whole structure is calculated by summing RCS of each surface, which can be obtained from an analytical solution of flat surface phase integral derived from physical optics. The reflected and hidden surfaces are searched by an object precision method based on adaptive triangular beam method, which can take account for effects of multiple reflections and polarizations of electromagnetic wave. The validity of the presented RCS analysis method has been verified by comparing with exact solutions and measured data for various structures.

A Study on Vehicle-based Durability Evaluation for Weight-reduced Valve Parts of the Dual Clutch Transmission

  • ChanEun Kim;TaeWook Kim
    • Tribology and Lubricants
    • /
    • 제40권1호
    • /
    • pp.24-27
    • /
    • 2024
  • A monotype valve body for a dual clutch transmission has the potential to reduce costs, weight, and manufacturing time by modularizing various parts, including those of existing solenoid packs and valve bodies, into one through the application of super-precision die casting technology. However, this approach may lead to challenges such as reduced rigidity and increased interference due to modularization and compactness, impacting both product performance due to the reduced weight as well as durability and reliability. Unlike existing products, this approach requires a high-precision thin-wall block to avoid more complicated flow line formation, interference between flow lines, and leaks, as well as a strict quality requirement standard and precise inspections including detection of internal defects. To conduct precise inspections, we built an equivalent model corresponding to a driving distance of 300,000 km. Testing involved simulating actual road loads using a real vehicle and a chassis dynamometer in the FTP-75 mode (EPA Federal Test Procedure). The aim of the study was to establish a vehicle load-based part durability model for manufacturing a mono-type valve body and to develop fundamental technology for part weight reduction through preliminary design by introducing analytical weight reduction technology based on the derived results.

원자력 시설 주변 환경 감시를 위한 토양 중 우라늄 동위원소 신속 분석법 확립 (Establishing of a rapid analytical method on uranium isotopic ratios for the environmental monitoring around nuclear facilities)

  • 박지영;임종명;이현우;이완로
    • 분석과학
    • /
    • 제31권3호
    • /
    • pp.134-142
    • /
    • 2018
  • The uranium isotopic ratio in environmental samples around nuclear facilities is important because it reveals information regarding illegal activities or anthropogenic pollution. Determination of uranium isotopes, however, is a challenging task requiring much labor and time because of the complex separation procedures and lengthy process. In this study, a rapid determination method for uranium isotopes in environmental samples was developed using. The sample was completely decomposed using the alkali fusion method. The separation procedure using extraction chromatography (UTEVA) was simplified in a single step without any further removal process for Si and major matrix elements. The established method can be completed within 3 h from sample dissolution to ICP-MS measurement. Most matrix elements and uranium isotopes in the soil samples were well separated and purified. Five types of were used to assess the method's accuracy and precision for a rapid uranium analysis method. The analytical accuracy for all CRM samples ranged from 95.1 % to 97.8 %, and the relative standard deviation was below 3.9 %. From the analytical results, one may draw conclusions that the evaluated method for uranium isotopes using alkali-fusion, the extraction chromatography process, and ICP-MS measurements is fast and fairly reliable owing to its recovering efficiencies. Thus, it is expected that the evaluated method can contribute to the improvement of environmental monitoring ability.

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

  • Lee, Jaeick;Lee, Seunghwa;Kim, Byungjoo;Lee, Joonhee;Kwon, Oh-Seung;Cha, Eunju
    • Mass Spectrometry Letters
    • /
    • 제9권1호
    • /
    • pp.30-36
    • /
    • 2018
  • A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

Development of Jaspine B analysis using LC-MS/MS and its application: Dose-independent pharmacokinetics of Jaspine B in rats

  • Song, Im-Sook;Jeon, Ji-Hyeon;Lee, Jihoon;Lim, Dong Yu;Lee, Chul Haeng;Lee, Dongjoo;Choi, Min-Koo
    • 분석과학
    • /
    • 제34권2호
    • /
    • pp.37-45
    • /
    • 2021
  • A rapid and simple LC-MS/MS analytical method in determining Jaspine B has been developed and validated in rat plasma. The standard curve value was 25 - 5000 ng/mL and the linearity, inter-day and intra-day accuracy and precision were within 15.0 % of relative standard deviation (RSD). The mean recoveries of Jaspine B ranged from 87.5 % to 91.2 % with less than 3.70 % RSD and the matrix effects ranged from 91.1 % to 108.2 % with less than 2.6 % RSD. The validated LC-MS/MS analytical method of Jaspine B was successfully applied to investigate the dose-escalated pharmacokinetic study of Jaspine B in rats following an intravenous injection of Jaspine B at a dose range of 1 - 10 mg/kg. The initial plasma concentrations and area under plasma concentration curves showed a good correlation with intravenous Jaspine B dose, indicating the dose independent pharmacokinetics of Jaspine B in rats. In conclusion, this analytical method for Jaspine B can be easily applied in the bioanalysis and pharmacokinetic studies of Jaspine B, including its administration at multiple therapeutic doses, or for making pharmacokinetic comparisons for the oral formulations of Jaspine B in small experimental animals as well as in vivo pharmacokinetic-pharmacodynamic correlation studies.

Qualitative and quantitative determination of oleanolic acid in a scalp tonic products by HPLC using response surface methodology for extraction optimization

  • Cai, Lin Xi;Cho, Chong Woon;Zhao, Yan;Kang, Jong Seong;Kim, Kyung Tae;Jung, Sang-Hun
    • 분석과학
    • /
    • 제32권2호
    • /
    • pp.48-55
    • /
    • 2019
  • The simple and effective analytical method for the quality control of a novel scalp tonic formulation has been developed and optimized in terms of HPLC conditions and sample preparation method, meanwhile, the optimization of preparation condition was using response surface methodology (RSM) based on central composite design (CCD). Oleanolic acid was selected as marker compound because of its bioactivities for alopecia therapy. The developed analytical method and extraction condition were successfully qualified. Coefficient of determination ($r^2$) for the calibration was 0.9997 with a line passing through the origin point in the range of 0.1-100 mg/mL. The limit of detection (LOD) and the limit of quantitation (LOQ) were 17.5 ng/mL and 55.0 ng/mL, respectively. The intra-day and inter-day precision of the method were 0.5-1.4 % and 0.7-1.8 % in relative standard deviation, respectively, while those accuracy were 99.5-100.9 % and 100.0-102.2 %, respectively. The repeatability of oleanolic acid in samples ranged of 0.3-1.9 % based on peak area and 0.3-0.7 % for retention time. Recoveries from samples were 95.0-99.4 % with lower than 1.8 % in relative standard deviation. Overall, the developed analytical method will be used for quality control of this commercial scalp tonic products successfully.