• 제목/요약/키워드: Analysis Response Spectrum

검색결과 741건 처리시간 0.025초

입력운동 생성방법과 강진지속시간에 따른 면진원전의 거동 분석 (Behavior Analysis of a Seismically Isolated NPP Structure by Varying Seismic Input Generation Method and Strong Ground Motion Duration)

  • 김현욱;주광호;노상훈;정창균
    • 한국지진공학회논문집
    • /
    • 제17권4호
    • /
    • pp.187-195
    • /
    • 2013
  • In this paper, firstly, acceleration-time histories were generated by varying strong motion duration in the frequency domain for application to a seismically isolated nuclear power structure, so as to examine the effects of strong motion duration on the behavior of the structure. Secondly, real recorded earthquakes were modified to match the target response spectrum based on the revised SRP 3.7.1(2007) and the modified time histories were applied to the analysis of a seismically isolated nuclear power structure. The obtained values of acceleration and displacement responses of the structure were, finally, compared with the values obtained in case of applying acceleration-time histories generated in the frequency domain to the structure.

변동풍속의 파워 스펙트럴 밀도에 관한 평가 (Estimation on the Power Spectral Densities of Daily Instantaneous Maximum Fluctuation Wind Velocity)

  • 오종섭
    • 한국방재안전학회논문집
    • /
    • 제10권2호
    • /
    • pp.21-28
    • /
    • 2017
  • 시공간적으로 불규칙하게 작용하는 변동 풍속 난류의 자료는 풍공학적으로 돌풍계수 평균풍속 변동 풍하중등의 계산에서 요구되지만, 내풍 및 사용성에 따른 동적응답의 평가에서는 변동 풍속의 파워 스펙트럴 밀도함수가 요구된다. 본 논문에서는 1987-2016.12.1일까지의 일순간최대풍속 자료를 확률과정으로 가정했고, 이 실측된 자료와 확률이론을 근거로 평균류방향 파워 스펙트럴 밀도 함수에 대한 기초적 자료를 얻고자 대표지점(6개 지점)을 선정했다. 선정된 각 지점에 대한 일순간최대풍속자료는 기상청으로부터 획득했다. 해석결과 본 논문에서 평가된 스펙트럼 모델은 저진동수 영역에서는 Solari, 고진동수 영역에서는 von Karman의 모델과 근접한 현상을 나타냈다.

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

Experimental investigations on seismic responses of RC circular column piers in curved bridges

  • Jiao, Chiyu;Li, Jianzhong;Wei, Biao;Long, Peiheng;Xu, Yan
    • Earthquakes and Structures
    • /
    • 제17권5호
    • /
    • pp.435-445
    • /
    • 2019
  • The collapses of curved bridges are mainly caused by the damaged columns, subjected to the combined loadings of axial load, shear force, flexural moment and torsional moment, under earthquakes. However, these combined loadings have not been fully investigated. This paper firstly investigated the mechanical characteristics of the bending-torsion coupling effects, based on the seismic response spectrum analysis of 24 curved bridge models. And then 9 reinforced concrete (RC) and circular column specimens were tested, by changing the bending-tortion ratio (M/T), axial compression ratio, longitudinal reinforcement ratio and spiral reinforcement ratio, respectively. The results show that the bending-torsion coupling effects of piers are more significant, along with the decrease of girder curvature and the increase of pier height. The M/T ratio ranges from 6 to 15 for common cases, and influences the crack distribution, plastic zone and hysteretic curve of piers. And these seismic characteristics are also influenced by the compression ratio, longitudinal reinforcement ratio and spiral reinforcement ratios of piers.

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

Determination of critical excitation in seismic analysis of structures

  • Kamgar, Reza;Rahgozar, Reza
    • Earthquakes and Structures
    • /
    • 제9권4호
    • /
    • pp.875-891
    • /
    • 2015
  • Earthquake can occur anywhere in the world and it is essential to design important members in special structures based on maximum possible forces that can be produced in them under severe earthquake. In addition, since the earthquake is an accidental phenomena and there are no similar earthquakes, therefore the possibility of strong earthquakes should be taken into account in earthquake-resistant design of important structures. Based on this viewpoint, finding the critical acceleration which maximizes internal forces is an essential factor in structural design. This paper proposes critical excitation method to compute the critical acceleration in design of important members in special structures. These critical accelerations are computed so that the columns' internal shear force at the base of the structure at each time step is maximized under constraints on ground motion. Among computed critical accelerations (of each time step), the one which produces maximum internal shear force is selected. A numerical example presents to show the efficiency of critical excitation method in determining the maximum internal shear force and base moment under variety of constraints. The results show that these method can be used to compute the resonant earthquake which have large enough effective duration of earthquake strong motion (between 12.86 sec to 13.38 sec) and produce the internal shear force and base moment for specific column greater than the same value for selected earthquakes in constructing the critical excitation (for different cases about 2.78 to 1.29 times the San Fernando earthquake). Therefore, a group of them can be utilized in developing the response spectrum for design of special structures.

촉각자극에 의한 자율신경계 및 뇌파 반응과 감성 (Emotional Preference Modulates Autonomic and Cortical Responses to Tactile Stimulation)

  • Estate Sokhadze;Lee, Kyung-Hwa;Imgap Yi;Park, Sehun;Sohn, Jin-Hun
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1998년도 추계학술발표 논문집
    • /
    • pp.225-229
    • /
    • 1998
  • The purpose of the current study was comparative analysis of autonomic and electrocortical responses to passive and active touch of the tektites with different subjective emotional preference. Perspective goal of the project is development of a template for classification of tactile stimuli according to subjective comfort and associated physiological manifestations. The study was carried out on 36 female college students. Physiological signals were acquired by Grass and B10PAC 100 systems with AcqKnowledge III software. Frontal, parietal and occipital EEG (relative power spectrum /percents/ of EEG bands - delta, theta, slow and fast alpha, low and fast beta), and autonomic variables, namely heart rate (HR), respiratory sinus arrhythmia (RSA), pulse transit time (PTT), respiration rate (RSP) and skin conductance parameters (SCL, amplitude, rise time and number of SCRs) were analyzed for rest baseline and stimulation conditions. Analysis of the overall pattern of reaction indicated that autonomic response to tactile stimulation was manifested in a form of moderate HR acceleration, RSP increase, RSA decrease (lowered vagal tone), decreased n and increased electrodermal activity (increased SCL, several SCRs) that reflects general sympathetic activation. Parietal EEG effects (on contra-lateral side to stimulated hand) were featured by short-term alpha-blocking, slightly reduced theta and significantly increased delta and enhanced fast beta activity with few variations across stimuli. The main finding of the study was that most and least preferred textures exhibited significant differences in autonomic (HR, RSP, PTT, SCR, and at less extent in RSA and SCL) and electrocortical responses (delta, slow and fast alpha, fast beta relative power). These differences were recorded both in passive and active stimulation modes, thus demonstrating reproducibility of distinction between most and least emotionally preferred tactile stimuli, suggesting influence of psychological factors, such as emotional property of stimulus, on physiological outcome. Nevertheless, development of sufficiently sensitive .and reliable template for classification of emotional responses to tactile stimulation based on physiological response pattern may require more extensive empirical database.

  • PDF

비탄성 정적해석을 이용한 격자강판 전단벽 보강 RC구조물의 내진성능평가 (Seismic Performance Evaluation of RC Structure Strengthened by Steel Grid Shear Wall using Nonlinear Static Analysis)

  • 박정우;이재욱;박진영;이영학;김희철
    • 한국전산구조공학회논문집
    • /
    • 제26권6호
    • /
    • pp.455-462
    • /
    • 2013
  • 최근에 지어진 건축물의 경우 지진에 대한 안전성을 확보하고 있지만, 내진설계 도입 이전의 건축물은 지진에 대해 매우 취약하다. 본 연구에서는 내진성능이 부족한 기존 저층 RC구조물의 지진 발생 시 안전성 확보를 위한 내진보강 방안으로 격자강판 전단벽을 제안하고 내진성능평가를 수행하였다. 횡력저항요소로 사용된 격자강판 전단벽의 탄소성 이력특성값은 실험결과를 토대로 횡력저항 기여도등을 평가하여 작성된 이선형곡선을 적용하였다. 비탄성 정적해석을 통해 대상구조물의 성능점을 찾아내어 적용 지진하중에 대한 응답과 성능수준을 평가하였다. 격자강판 전단벽을 적용한 경우, 보강 전에 비하여 응답변위가 약 42% 저감되는 것을 확인할 수 있었으며, 성능점에서 거의 탄성거동을 보여주고 있어 목표성능인 인명안전수준을 만족시켰다. 또한 반응수정계수를 산정하여 내진보강 효과를 검증하였으며, 보강 전과 후에 각각 2.17에서 3.25로 증가하여 설계기준을 초과하였다. 따라서 격자강판 전단벽에 의해 대상 구조물의 강도 및 강성보강이 적절히 수행된 것으로 판단된다.

부유식 파력-해상풍력 복합 발전시스템의 등가설계파 기법 적용에 관한 연구 (A Study on Equivalent Design Wave Approach for a Wave-Offshore Wind Hybrid Power Generation System)

  • 손정민;신승호;홍기용
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권3호
    • /
    • pp.135-142
    • /
    • 2015
  • 부유식 해양구조물은 설계수명 동안 조우할 수 있는 가장 극심한 환경하중을 고려하여 설계되어야 한다. 본 연구의 해석 대상인 부유식 파력-해상풍력 복합 발전시스템에 가장 큰 영향을 미치는 환경하중은 파랑하중이다. 파랑하중의 주요 매개변수는 파장, 파고, 파향이며, 이들의 조합에 따라 구조물의 거동특성에 미치는 영향은 판이하다. 이에 따라, 대상 해역이 가지는 파랑의 특성과 구조물이 가지는 응답 특성을 기반으로 극한 응답을 주는 파랑인자를 탐색하는 과정이 필요하다. 즉, 환경조건 범위에서 발생할 수 있는 모든 파랑조건을 탐색하여 최대 응답을 발생시키는 등가설계파를 추출해야 한다. 이는 특정 하중의 최대 설계 응답과 동일한 응답 수준을 주는 규칙파를 탐색하는 일련의 과정을 통해 계산 가능하다. 본 연구에서는 부유식 파력-해상풍력 복합 발전시스템에 작용하는 특정 하중 인자에 대해 등가설계파를 산정하였으며, 전체구조해석에 활용하였다.

Monte Carlo 시물레이션에 기초한 포획모드 중성자-감마 스펙트럼 존데 설계 및 반응 분석 (Neutron Induced Capture Gamma Spectroscopy Sonde Design and Response Analysis Based on Monte Carlo Simulation)

  • 원병호;황세호;신제현;김종만;김기석;박창제
    • 지구물리와물리탐사
    • /
    • 제18권3호
    • /
    • pp.154-161
    • /
    • 2015
  • 본 연구에서는 중성자-감마 스펙트럼검층 존데 설계를 목적으로 Monte Carlo 시물레이션을 이용하여 열중성자 반응의 우세한 영역 파악 및 포획감마 스펙트럼의 에너지피크 값에 기초한 지층 구성 원소 구분을 수행하였다. 14 MeV 에너지준위의 중성자를 방출하는 중성자발생장치를 선원으로 이용하여 선원으로부터 10 cm 간격으로 12개의 중성자 검출기들을 배열함으로써 거리에 따른 열중성자 양을 측정하였다. 시추공 영향 저감을 위해 존데모형에 차폐재를 적용하여 보다 정확한 열중성자 측정을 수행하여 열중성자 반응이 우세한 위치를 분석한 뒤, 이 위치에서 검출된 포획감마 에너지 스펙트럼을 분석하여 지층을 구성하는 주요 원소 및 그 양을 확인하였다. 본 연구 결과는 중성자-감마 스펙트럼검층 존데의 신호대잡음 비 향상과 포획감마 검출기 최적 위치 선정에 도움이 될 것으로 판단된다.