A study on the development of a simulator for a boiler control system in order to test a back-up controller (백업(Back-up) 제어기의 성능 시험을 위한 보일러 제어시스템의 시뮬레이터 개발에 관한 연구)

  • 황동환;김지홍;변증남
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.603-606
    • /
    • 1987
  • A simulator is designed in order to evaluate the performance a f a lockup controller. The original analog controller and boiler plant are transformed into digital form model, in which the plant is modeled as a 2 input-2 output system connected to first order peripheral units. The experimented results show that the simulated system renders the same steady state characteristics as data and show usability of simulator.

  • PDF

PanelLink Digital Flat Panel Display Receiver for TFT LCD Test (TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 수신부 구현)

  • Baek, Woon-Sung;Lee, Seon-Bok;Park, Chang-Soo;Hong, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.618-620
    • /
    • 1998
  • We implemented PanelLink flat panel display receiver which can be used for testing SXGA($1280{\times}1024$) TFT LCD panel. We've got optimal analog input voltage to get stable image according to cable length. And we commented the way to reduce EMI.

  • PDF

Direct Observation of an Antihomoaromatic Bicyclooctadienyl Cation

  • Shin Jung-Hyu
    • Bulletin of the Korean Chemical Society
    • /
    • v.3 no.2
    • /
    • pp.66-70
    • /
    • 1982
  • The question of the bicyclohomoaromatic stabilization and destabilization is examined. The chemistry of bicyclo(3.2.1)octa-3,6-dienide anion has been studied on order to test these concepts. The bicyclooctadienide anion is shown to be stable delocalized ion which undergoes a facile proton-deuterium exchange reaction. The solvolysis of bicyclo(3.2.1)octa-3,6-dienyl p-nitrobenzoate is much slower than the monoene analog. We have made direct observation of the bicyclooctadienyl and octenyl cations by $^{19}F$-nmr spectroscopy, and were able to demonstrate that the bicyclooctadienyl cation was bishomoantiaromatic.

Field Test Results of Terrestrial Digital TV in Korea (한국의 지상파 DTV 필드테스트 결과)

  • 목하균;서영우;황해섭
    • Journal of Broadcast Engineering
    • /
    • v.5 no.2
    • /
    • pp.140-158
    • /
    • 2000
  • Testing of terrestrial Digital TV(DTV) broadcasting in Seoul and Kyung-gi region was started in May 1999. Tasks of the committee for DTV technical evaluation were to implement test procedures for DTV transmitting systems, to analyze various technical aspects of DTV and to complete a field test. This paper summarizes the field test results. The field test vehicle was designed and constructed to measure field data. We chose over 200 test points to verify the receiving status of DTV signals and compared them with the analog TV signals at the same site. The results showed stable and satisfactory reception of DTV signals over 70%. The system performance index was over 80%.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF

The Study on the Development of the HD(High Definition) Level Triple Streaming Hybrid Security Camera (HD급 트리플 스트리밍 하이브리드 보안 카메라 개발에 관한 연구)

  • Lee, JaeHee;Cho, TaeKyung;Seo, ChangJin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.252-257
    • /
    • 2017
  • In this paper for developing and implementing the HD level triple streaming hybrid security camera which output the three type of video outputs(HD-SDI, EX-SDI, Analog). We design the hardware and program the firmware supporting the main and sub functions. We use MN34229PL as image sensor, EN778, EN331 as image processor, KA909A as reset, iris, day&night function part, A3901SEJTR-T as zoom/focus control part. We request the performance test of developed security camera at the broadcasting and communication fusion testing department of TTA (Telecommunication Technology Association). We can get the three outputs (HD-SDI, EX-SDI, Analog) from the developed security camera, get the world best level at the jitter and eye pattern amplitude value and exceed the world best level at the signal/noise ratio, and minium illumination, power consumption part. The HD level triple streaming hybrid security camera in this paper will be widely used at the security camera because of the better performance and function.

A Development of Eddy Current Testing System for Steam Generators Inspection in Nuclear Power Plants (원전 증기발생기 와전류검사 시스템 개발)

  • Moon, Gyoon-Young;Cho, Chan-Hee;Yoo, Hyun-Joo;Lee, Tae-Hun;Cho, Yong-Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.40-47
    • /
    • 2013
  • The capacity factor of nuclear power plant in Korea is the highest level in the world. However, the integrity assessment of nuclear power plant is depended on foreign country. Especially, most eddy current testing systems for inspecting steam generators in nuclear power plant are currently imported from USA, Canada, and so on. Therefore, the eddy current testing system can react more active and adaptive from economic and managerial standpoint for actual nuclear power plants in Korea is required. In this paper, an eddy current testing system for inspecting steam generators in nuclear power plants is introduced. Frequency generator, analog circuit, analog digital converter circuit, and digital control circuit are composed in eddy current testing system. A benchmarking of acquisition system and acquisition software, eddynet 11i made by Zetec, and modifications are carried out based on the test environment of Korea nuclear power plants. Finally, all eddy current apparatus are integrated to inspect steam generator tubes in nuclear power plants.

Validity, Reliability and Efficiency of Pain Self-report Scale in Elderly with Dementia (치매노인의 통증사정에 대한 자가보고 도구의 타당도, 신뢰도 및 효율성 검증)

  • Ryoo, Eon-Na;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.23 no.2
    • /
    • pp.111-122
    • /
    • 2011
  • Purpose: The aim on this study was to establish the validity, reliability and efficiency of a Pain Self-Report Scale for elderly with dementia and compare these results with an observational pain rating scale. Methods: Study subjects were 136 elderly with dementia who were residents in a nursing home, geriatric hospital, or day care center. The subject's pain was measured by five self-report scales and observational scale. DS-DAT (discomfort scale-dementia of the Alzheimer's type) was used for pain behavior observational measure. Cognitive state was assessed using the MMSE (Mini-Mental State Examination). Results: Observational rating correlated moderately with self-report (r=.225~.585, p<.05) and tended to underestimate pain intensity. Test-retest reliability was high for all five self-report scales, and the correlation between these scales was very strong (r=.735~.856, p<.05). Comprehension rate of VDS (verbal descriptor scale) was 88.3%, and NRS (numeric rating scale) 69.9%, FPS (face pain scale) 66.9%, HVAS (horizontal visual analog scale) and VVAS (vertical visual analog scale) 65.4%. Conclusion: Nurses should not apply observational scales routinely in demented patients as many of these are capable of reporting their own pain. Self-report, the highest standard of pain measurement can be reliably performed in a large proportion of demented elderly.

Efficient distribution support of Shipping Request Data based on Digitalized Character Recognition (디지털 문자 판독기술을 적용한 선적요청서 데이터의 효율적인 유통지원)

  • Park, Joon-Hyuk;Goh, Hyun-Woo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.31 no.2
    • /
    • pp.112-121
    • /
    • 2008
  • Nowaday the supply chain competitiveness is emphasized more and more than a company's own competitiveness. One of the most important processes in import and export is a publication over the Bill of Loading. In the publication of those bills S/R(shipping request) and check B/L for reviewing are circulated among consignors, forwarders, shipping companies and airlines by fax and e-mail. Or there should be expensive a One to One system, like an EDI. Each party has to re-input S/R data to their own systems and check it several times. The S/R data are converted digital to analog type and analog to digital repeatedly to check in the process. As the process goes by there can be not only input data errors but also waste of time and cost. ECR(electronic character recognition) is a technology can solve the Problem. Considering the data structure of documents in many systems used ECR samples SIR data from documents written in the digital type. But it is not enough with it only. To make N to N composition in reality more efficient we make a documents hub on the web reengineering the existing process to One to One relation. The ECR documents hub system has given us beneficial effects over a year throughout a field test.