• Title/Summary/Keyword: An-yang stream

Search Result 145, Processing Time 0.029 seconds

A Proposal of Baseflow using Discharge Measurement Method in the Streams of Island (도서지역 하천의 기저유출량 산정을 위한 유량측정방법 제안)

  • Lee, Jun-Ho;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.561-569
    • /
    • 2014
  • The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 $m^3/s$, whereas the average ADC and Flowmate is 0.709 $m^3/s$. Meanwhile, stream discharge has been calculated 0.709 $m^3/s$ through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers' strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.

Spatial Distribution of Heavy Metals in Geum River after Weirs Construction (금강에서 보 설치 후 퇴적물 중금속 분포)

  • Yang, Yun Mo;Shim, Moo Joon;Oh, Da Yeon;Khan, Jong Beom;Lee, Jun Bae;Hong, Seoun Hwa;Lee, Soo Hyung;Park, Sang Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.1
    • /
    • pp.64-68
    • /
    • 2015
  • BACKGROUND: Heavy metals (Al, As, Cd, Cr, Cu, Li, Hg, Ni, Pb, and Zn) were analyzed to elucidate the impact of weir construction on their concentrations in sediments of Geum River, Korea. We also attempted to investigate the source of the heavy metals in sediments. METHODS AND RESULTS: For this study, sediments were collected from May through June in 2012. The concentrations of heavy metals except Hg were determined by inductively coupled plasma mass spectrometer, and Hg was measured by automatic mercury analyzer. More clay were accumulated in the furthest stations in the upstream direction starting from the weirs. Most of the heavy metals showed higher concentrations in the most upstream located station of Geumnam Weir. However, high concentrations were not observed in the most upstream stations of the other weirs. The concentrations of Hg and As were much higher in sediments of Gap Stream. CONCLUSION: Gap Stream may be a potential source for high deposits of As and Hg. Presence of the dams may not play an important role in controlling heavy metal concentrations in sediments. It is necessary to monitor heavy metal concentrations for a longer time period to study the effect of environmental changes on heavy metal distribution in Geum River.

An Experimental Study on Mode Switching from Air-firing to Oxy-firing in Pilot-scale Combustion Systems (미분탄 순산소 연소 운전 모드 전환 과정에 대한 Pilot 규모 설비에서의 실험적 연구)

  • Choi, Chong-Gun;Na, Ik-Hwan;Lee, Jae-Wook;Chae, Tae-Young;Yang, Won;Kim, Young-Ju;Kim, Jong-An;Seo, Sang-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.12-20
    • /
    • 2011
  • Oxy-coal combustion for $CO_2$ capture in coal power plants entails a mode switching from air-firing to oxyfiring. In this study, procedure of the mode switching was investigated and discussed through experiments in pilot scale facilities: (1) a 0.3 $MW_{th}$ furnace with a vertical single burner and a FGR(Flue Gas Recirculation) system (2) a 1 $MW_{th}$ furnace with horizontal 4 burners and a FGR system. Principle of the mode switching was established and performed with control of FD fan, FGR fan, ID fan and oxygen flow rates. We have found that equivalence ratio in the oxy-firing mode should be increased more than that in the air-firing to achieve stable mode switching. Control of FD, ID and FGR fans should be performed carefully in the mode switching, in the sense of complete combustion and flame attachment. Moisture contents in the ash and the flue gas recycled to the primary oxidizer stream should be removed to prevent condensation, corrosion and duct clogging.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

Daesoon Thought Explained Through the Philosophy of the Book of Change (대순사상의 역학적 조명 - 종지(宗旨)를 중심으로 -)

  • Choi, Young-Jin
    • Journal of the Daesoon Academy of Sciences
    • /
    • v.20
    • /
    • pp.169-191
    • /
    • 2009
  • The Four Tenets of Daesoon thought are the Creative conjunction of the virtues of Eum and Yang, the Harmonious union of divine beings and human beings, the Resolution of grievances for the mutual beneficence of all life and the Realization of the Dao in the world. This article compares the concepts of the "Creative conjunction of the virtues of Eum and Yang", the "Harmonious union of divine beings and human beings" and the "Resolution of grievances for the mutual beneficence of all life" with "EumYangDaeDaeRon", "ShinMyonKiDeok", the Theory of Mutual Giving Life / Mutual Destruction (SangSaeng/SangGeukRon) of the Book of Changes and analyzes their common and different points. The conclusion is that Daesoon thought and the philosophy of the Book of Changes share common fundamental standpoints. However, the Daesoon thought defines the world of SeonCheon (the state before the Heaven and Earth have been created) as Mutual Giving Life (SangSaeng), and the world of HuCheon (the state after the Heaven and Earth have been created) as Mutual Destruction (SangGeuk). According to Daesoon thought the Mutual Destruction (SangGeuk) is seen as negative, while according to the philosophy of the Book of Changes the Theory of Mutual Giving Live/Mutual Destruction (SangSaeng/SangGeukRon) is viewed as a positive relationship of EumYangDaeDae. This is a point of difference between the Daesoon thought and the philosophy of the Book of Changes. According to EumYangDaeDae relationship theory the contradictory "other" is viewed not as an enemy, but as a necessary element that assures one's existence. When Buddhism and Christianity first came to existence, they did not belong to a main stream. Later, through continuous theorization and systematization they became generally accepted religions. The case of Confucianism was not much different. During Song dynasty in China Buddhism has contributed to the systematization and establishment of Neo-Confucianism; in the middle of 20th century the Confucian scholars of Hong Kong and Taiwan interpreted and defined Confucianism a new in the light of Western philosophy. Thus the "Modern Neo-Confucianism" came to existence. That's why the history of Confucianism is also called "the history of advancing and developing a concept". From this point of view the critical acceptance of some elements of Confucian, Buddhist, Taoist etc. traditions, as well as modern philosophy, by Daesoon, in order to achieve the systematization of Daesoon thought, is a very important process. As a part of this process, this essay explains the Daesoon thought from the point of view of the Book of Changes, which may be said to present the original East-Asian view of the world. Daesoon's emphasis of human dignity, the equality of sexes, the critics the hierarchical society etc. are rather "modern" and should be examined from the point of view of social science. Besides, leaving the boundaries of "modern philosophy", the concepts of "Harmonious union of divine beings and human beings", viewing the universe as one organism etc. should be approached from the point of view of Post-Modernism.

  • PDF

Nutrient Uptake by Reeds Growing in Subsurface-flow Wetland Constructed to Purify Stream Water (하천수정화 여과습지에서 성장하는 갈대의 영양염류 흡수량)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.89-99
    • /
    • 2006
  • The growth and biomass of reeds(Phragmites australis) growing in a subsurface treatment wetland system were investigated from April 2003 to October 2003. Nitrogen(N) and phosphorous(P) concentrations in above-ground(AG) and below-ground(BG) tissues of reeds were examined and the removal rate of N and P by reeds were analyzed. The system, 29 m in length, 9 m in width and 0.65 m in depth, was constructed in June 2001 on a floodplain in the down reach of the Kwangju Stream in Korea in order to purify polluted water of the stream. A bottom layer of 45 cm in depth was filled with crushed granites(15~30 mm in diameter) and a middle layer of 10 cm in depth was filled with pea pebbles(10 mm in diameter). An upper layer of 5 cm contained course sand. Reeds were transplanted on the surface of the system, which were dug out of natural wetlands, and their shoots were trimmed 40 cm in height. The height and density of the shoots averaged 237.7 cm and 244.0 shoot/$m^2$, respectively, when the reeds grew fully. The maximum biomass of AG and BG tissues were 1,964 and 1,577 g/$m^2$, respectively, and the AG : BG ratio of biomass was 1.26. Mean AG and BG dry weights were recorded as 1,355 and 748 g/$m^2$, respectively. The AG and BG tissue concentrations of N averaged 12.37 and 10.01 mg/g, respectively, and those of P 2.37 and 2.03 mg/g, respectively. Inflow to the system averaged 40 $m^3$/day. The concentrations of total nitrogen(T-N) in influent and effluent were 8.4 mg/L and 3.2 mg/L, respectively, and those of total phosphorous(T-P) were 0.73 and 0.38 mg/L, respectively. The total removal of T-N and T-P by the system during the investigation period averaged 140.2 and 9.7 g/$m^2$, respectively, and the total uptake of N and P by the reeds were calculated as 24.39 and 4.73 g/$m^2$, respectively. Average removals of about 17% of N and about 49% of P by reeds were recorded. The N and P concentrations in AG tissues were significantly different among the three zones of the system:near to inflow(St1), in the middle of system(St2), and near to outflow(St3). The N and P concentrations in BG tissues were also significantly different among St1, St2 and St3. N and P concentrations in AG and BG tissues of reeds growing in St1 were higher than those in St2 and St3. The height and density of shoots of reeds in St1 were larger than those in St2 and St3. Significant amounts of N and P in the influent were taken up by reeds in St1.

Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water (신양천 하천수정화 연못시스템의 처리수준 및 연못반응)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

A study on CIM construction for the plastic fan design manufacturing (플라스택 팬 설계, 제조의 CIM 구축을 위한 연구)

  • Choi, Yang-Ho;Lee, Yong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1470-1479
    • /
    • 1997
  • In this study, the plastic fan with high efficiency and low noise was designed and the capacity of the wind and the wind pressure were analysed and verified by CAE. After designing the metallic mold using the metallic mold design data, and the the metallic mold design was reformed by analysing the process of the material stream and injection filling by CAE. Also the metallic mold cutting data were formed using the metallic mold design data. These cutting data was used to produce the fan electrode by a machining center and then this electrode were used to manufacture the metallic mold by cutting the fan cavity by an electrical spark machine. The purpose of this study is to find out the sub-optimal condition on the productivity and improvement in quality of the plastic fan by integrating a series of this process with a computer.

Method Validation for the Simultaneous Analysis of Organophosphorous Pesticides in Blood by GC/MS (GC/MS를 이용한 혈액 중 유기인제류 농약의 동시 분석에 관한 방법의 유효화)

  • Park Mee Jung;Yang Ja Youl;Kim Ki Wook;Park Yoo Shin;Chung Hee Sun;Lee Sang Ki
    • Environmental Analysis Health and Toxicology
    • /
    • v.20 no.4 s.51
    • /
    • pp.297-302
    • /
    • 2005
  • The purpose of this study was to provide the standard method for the analysis of organophosphorous pesticides such as chlorpyrifos, diazinon, malathion and parathion in blood. We performed method validation for these pesticides in blood according to EURACHEM (A focus For Analytical Chemistry in Europe) guide. For the analysis of the pesticides, we used solid-phase extraction ,column (Waters Oasis $HLB^{(R)}$. After the extraction, the supernatants were evaporated to dryness under the nitrogen stream. They were analyzed by gas chromatography/mass spectrometry (GC/MS) after reconstituting with ethanol. Terbufos was used as an internal standard. To validate this method, we performed verification procedures with the following parameters: selectivity, linearity of calibration, accuracy, precision, limit of detection and quantification. Validation data according to Eurachem guide were adequate for our purpose for the analysis of chlorpyrifos, diazinon, malathion and parathion in blood.

DISTRIBUTION OF ORGANIC MATTERS AND RELEASE CHARACTERISTICS IN DAM RESERVOIR

  • Lee, Yo-Sang;Kim, Woo-Gu;Koh, Deuk-Koo;Yang, Jae-Rheen
    • Water for future
    • /
    • v.35 no.5
    • /
    • pp.21-30
    • /
    • 2002
  • The inflow into a multi-purpose dam reservoir contains many suspended solids from the upper stream during the rainy season. Concentrations of SS increased to 73.3 mg/l and the TP measurement increased to 0.09 mg/l during the rainy season in 1999. It was discovered that particles less than $10\;\mu\textrm{m}$ in size composed about 50% of the total amount. Some of these particles reduce the reservoir capacity and have an impact on water. In this study, the sediment depth at Daecheong multi-purpose dam was examined. Piston coring was performed at 9 locations At Hoenam 1 out of 9 locations examined showed maximum depth, which was 90 cm and at Muneui 3 showed the minimum depth, which was 35 cm. At Hoenam, the release rate of TN was found to be $62.14~84.72\;mg/\textrm{m}^2{\cdot}day$ in 1998. However, it was found to considerably reduced to $23.20\;mg/\textrm{m}^2{\cdot}day$ in 2001. The release rate of TP was measured at $13.02~14.38\;mg/\textrm{m}^2$.day at 1998, and it was reduced to $6.93mg/\;mg/\textrm{m}^2{\cdot}day$ in 2001.

  • PDF