• Title/Summary/Keyword: An advanced research reactor

Search Result 226, Processing Time 0.027 seconds

Plant-scale experiments of an air inflow accident under sub-atmospheric pressure by pipe break in an open-pool type research reactor

  • Donkoan Hwang;Nakjun Choi;WooHyun Jung;Taeil Kim;Yohan Lee;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1604-1615
    • /
    • 2023
  • In an open-pool type research reactor with a downward forced flow in the core, pipes can be under sub-atmospheric pressure because of the large pressure drop at the reactor core in the atmospheric pool. Sub-atmospheric pressure can result in air inflow into the pipe from the pressure difference between the atmosphere and the inside of the pipe, which in a postulated pipe break scenario can lead to the breakdown of the cooling pump. In this study, a plant-scale experiment was conducted to study air inflow in large piping systems by considering the actual operational conditions of an advanced research reactor. The air inflow rate was measured, and the entrained air was visualized to investigate the behavior of air inflow and flow regime depending on the pipe break size. In addition, the developed drift-flux model for a large vertical pipe with a diameter of 600 mm was compared with other correlations. The flow regime transition in a large vertical pipe under downward flow was also studied using the newly developed drift-flux model. Consequently, the characteristics of two-phase flow in a large vertical pipe were found to differ from those in small vertical pipes where liquid recirculation was not dominant.

수출전략형 연구로의 1차 냉각계통 개념설계 (The Conceptual Design of Primary Cooling System for an Advanced Research Reactor)

  • 박용철;김경련
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.503-508
    • /
    • 2005
  • An advanced Research Reactor (ARR) consists of an open-tank-type reactor assembly within a light water pool and generates thermal power of 20 MW. The thermal power is including a fission heat in the core, a fuel generated heat temporary stored in the pool, a circulating pumps generated heat and a neutron reflecting heat in the reflector vessel of the reactor. In order to remove the heat load, the primary cooling system will be installed. In this study, the conceptual design of the primary cooling system has been carried out using a design methodology of HANARO within a permissible range of safety. As results, it has been established that the conceptual design of the primary cooling system including design requirements, performance requirements, design restrictions, system descriptions and system operation to maintain the system functions.

  • PDF

Impact of axial power distribution on thermal-hydraulic characteristics for thermionic reactor

  • Dai, Zhiwen;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3910-3917
    • /
    • 2021
  • Reactor fuel's power distribution plays a vital role in designing the new generation thermionic Space Reactor Power Systems (SRPS). In this paper, the 1/12th SPACE-R's full reactor core was numerically analyzed with two kinds of different axial power distribution, to identify their impacts on thermal-hydraulic and thermoelectric characteristics. In the benchmark study, the maximum error between numerical results and existing data or design values ranged from 0.2 to 2.2%. Four main conclusions were obtained in the numerical analysis: a) The axial power distribution has less impact on coolant temperature. b) Axial power distribution influenced the emitter temperature distribution a lot, when the core power was cosine distributed, the maximum temperature of the emitter was 194 K higher than that of the uniform power distribution. c) Comparing to the cosine axial power distribution, the uniform axial power distribution would make the maximum temperature in each component of the reactor core much lower, reducing the requirements for core fuel material. d) Voltage and current distribution were similar to the axial electrode temperature distribution, and the axial power distribution has little effect on the output power.

An Investigation of Thermal Margin for External Reactor Vessel Cooling(ERVC) in Large Advanced Light Water Reactors(ALWR)

  • Park, Jong-Woon;Jerng, Dong-Wook
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.473-478
    • /
    • 1997
  • A severe accident management strategy, in-vessel retention corium through external reactor vessel cooling(ERVC) is being studied worldwide as a means to prevent reactor vessel failure following a core melt accident. An evaluation of feasibility of this ERVC for a large Advanced Light Water Reactor (ALWR) is presented. To account for the coolability of corium and metal in the reactor vessel, a thermal analysis is performed using an existing method. Results show that the peak heat flux along the inner surface of the reactor vessel lower head has a relatively smaller margin than a small capacity reactor such as AP600 in regards with the critical heat flux attainable at the outer surface of the reactor vessel lower head.

  • PDF

원자로 사고 또는 과도상태시 공기방출현상에 대한 연구 (Study of Air Clearing during Severe Transient of Nuclear Reactor Coolant System)

  • 배윤영;김환열;송철화;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.835-838
    • /
    • 2002
  • An experiment has been performed using a facility, which simulates the safety depressurization system (SDS) and in-containment refueling water storage tank (IRWST) of APR1400, an advanced PWR being developed in Korea, to investigate the dynamic load resulting from the blowdown of steam from a steam generator through a sparser. The influence of the key parameters, such as air mass, steam pressure, submergence, valve opening time, and pool temperature, on frequency and peak toads was investigated. The blowdown phenomenon was analyzed to find out the real cause of the initiation of bubble oscillation and discrepancy in frequencies between the experiment and calculation by conventional equation for bubble oscillation. The cause of significant damping was discussed and is presumed to be the highly tortuous flow path around bubble. The Rayleigh-Plesset equation, which is modified by introducing method of image, reasonably reproduces the bubble oscillation in a confined tank. Right after the completion of air discharge the steam discharge immediately follows and it condenses abruptly to provide low-pressure pocket. It may contribute to the negative maximum being greater than positive maximum. The subsequently discharging steam does not play as at the driving force anymore.

  • PDF

Vessel failure sensitivities of an advanced reactor for SBLOCA

  • Jhung, Myung Jo;Oh, Chang-Sik;Choi, Youngin;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.185-191
    • /
    • 2020
  • Plant-specific analyses of an advanced reactor have been performed to assure the structural integrity of the reactor pressure vessel during transient conditions, which are expected to initiate pressurized thermal shock (PTS) events. The vessel failure probabilities from the probabilistic fracture mechanics analyses are combined with the transient frequencies to generate the through-wall cracking frequencies, which are compared to the acceptance criterion. Several sensitivity analyses are performed, focusing on the orientations and sizes of cracks, the copper content, and a flaw distribution model. The results show that the integrity of the reactor vessel is expected to be maintained for long-term operation beyond the design lifetime from the PTS perspective using the design data of the advanced reactor. Moreover, a fluence level exceeding 9×1019 n/㎠ is found to be acceptable, generating a sufficient margin beyond the design lifetime.

An evaluation on in-pile behaviors of SiCf/SiC cladding under normal and accident conditions with updated FROBA-ATF code

  • Chen, Ping;Qiu, Bowen;Li, Yuanming;Wu, Yingwei;Hui, Yongbo;Deng, Yangbin;Zhang, Kun
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1236-1249
    • /
    • 2021
  • Although there are still controversial opinions and uncertainty on application of SiCf/SiC composite cladding as next-generation cladding material for its great oxidation resistance in high temperature steam environment and other outstanding advantages, it cannot deny that SiCf/SiC cladding is a potential accident tolerant fuel (ATF) cladding with high research priority and still in the engineering design stage for now. However, considering its disadvantages, such as low irradiated thermal conductivity, ductility that barely not exist, further evaluations of its in-pile behaviors are still necessary. Based on the self-developed code we recently updated, relevant thermohydraulic and mechanical models in FROBA-ATF were applied to simulate the cladding behaviors under normal and accident conditions in this paper. Even through steady-state performance analysis revealed that this kind of cladding material could greatly reduce the oxidation thickness, the thermal performance of UO2-SiC was poor due to its low inpile thermal conductivity and creep rate. Besides, the risk of failure exists when reactor power decreased. With geometry optimization and dopant addition in pellets, the steady-state performance of UO2-SiC was enhanced and the failure risk was reduced. The thermal and mechanical performance of the improved UO2-SiC was further evaluated under Loss of coolant accident (LOCA) and Reactivity Initiated Accident (RIA) conditions. Transient results showed that the optimized ATF had better thermal performance, lower cladding hoop stress, and could provide more coping time under accident conditions.

High fidelity core flow measurement experiment for an advanced research reactor using a real scale mockup

  • Taeil Kim;Yohan Lee;Donkoan Hwang;WooHyun Jung;Nakjun Choi;Seong Seok Chung;Jihun Kim;Jonghark Park;Hyung Min Son;Kiwon Song;Huiyung Kim;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제56권9호
    • /
    • pp.3700-3716
    • /
    • 2024
  • Owing to spatial effects and vortex flow, flow in research reactors that use plate-type fuels can be maldistributed to the parallel channels of the core, which significantly impacts the reactor safety. In this study, the core flow of an advanced research reactor was measured in a real-scale facility under various hydraulic conditions. For flow measurement, integrated pressure lines were embedded in the mockups of 22 fuel assemblies and six fission molybdenum assemblies. Each assembly mockup was individually calibrated to obtain the relationship between the pressure drop and flow rate. Real-scale facility, which implements the characteristics of the hydraulic conditions in research reactors, was then used to evaluate the assembly-to-assembly flow distribution under normal operating condition, a partially withdrawn condition for the follower fuel assemblies, no flow for the pool water management system, and 1:1.5 asymmetric inlet flow condition. As a parallel channel system, core flow distribution was analyzed with conventional header design approach. Taking into account the measuring uncertainty, the core flow was uniformly distributed within 5 % under all conditions. This was mainly because the core flow resistance was sufficiently high and the vortex flow was minimized by the perforated plate.

Design and heat transfer optimization of a 1 kW free-piston stirling engine for space reactor power system

  • Dai, Zhiwen;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2184-2194
    • /
    • 2021
  • The Free-Piston Stirling engine (FPSE) is of interest for many research in aerospace due to its advantages of long operating life, higher efficiency, and zero maintenance. In this study, a 1-kW FPSE was proposed by analyzing the requirements of Space Reactor Power Systems (SRPS), of which performance was evaluated by developing a code through the Simple Analysis Method. The results of SAM showed that the critical parameters of FPSE could satisfy the designed requirements. The heater of the FPSE was designed with the copper rectangular fins to enhance heat transfer, and the parametric study of the heater was performed with Computational Fluid Dynamics (CFD) software STAR-CCM+. The Performance Evaluation Criteria (PEC) was used to evaluate the heat transfer enhancement of the fins in the heater. The numerical results of the CFD program showed that pressure drop and Nusselt number ratio had a linear growth with the height of fins, and PEC number decreased as the height of fins increased, and the optimum height of the fin was set as 4 mm according to the minimum heat exchange surface area. This paper can provide theoretical supports for the design and numerical analysis of an FPSE for SRPSs.