• Title/Summary/Keyword: Amplified spontaneous emission

Search Result 54, Processing Time 0.022 seconds

A Streak Camera Study of Amplified Spontaneous Emission in Polyfluorene Thin Film

  • Shin, Hee-Won;Kim, Yong-Rok
    • Rapid Communication in Photoscience
    • /
    • v.4 no.4
    • /
    • pp.76-78
    • /
    • 2015
  • We report on the photoluminescence (PL) properties of poly[2,7-(9-9-dioctylfluorene)] (PF) thin film under strong optical pumping using a streak camera system. When the excitation energy density increases above $72{\mu}J{\cdot}cm^{-2}$, the emission spectrum becomes narrower and PL decay curve comes to be faster simultaneously. These behaviors are clear evidence of Amplified Spontaneous Emission (ASE) due to a waveguided Stimulated Emission in slab structure of thin film. ASE threshold of $72{\mu}J{\cdot}cm^{-2}$ is comparable with previous reports and PF is attractive as a gain medium for plastic lasers.

Measurement of Multimode Fiber Bandwidth by the Fourth-Order Spectra of Amplified Spontaneous Emission

  • Moon, Sucbei;Kim, Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • We present a novel bandwidth measurement scheme for multimode optical fibers. Amplified spontaneous emission (ASE) radiation was utilized for a source of intrinsically modulated light with a wide modulation bandwidth. In our measurement scheme, the continuous-wave (CW) ASE light that passed through a multimode fiber (MMF) under test was analyzed by the fourth-order power with a high-speed photodetector and an electric spectrum analyzer. The modulation transfer function of the multimode fiber could be directly measured with the photoelectric spectra in the modulation frequency domain. The measurement result of our method was experimentally compared to that of the conventional measurement scheme based on the impulse response measurement. It has been found that our scheme provides a stable measurement means of MMF characterization that is suitable for the field testing due to the simplicity of the system.

The Parameter Extraction of DFB-type Structures using ASE Spectrum (ASE 스펙트럼을 이용한 DFB 유형의 구조 파라미터의 추출)

  • Kim Minnyun;Cha Kyusu;Lee Jungho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.11a
    • /
    • pp.118-120
    • /
    • 2004
  • We propose the algorithm for parameters extraction through measured subthreshold amplified spontaneous emission (ASE) spectra for various DFB-type LDs. we compare spectra for extraction parameters through its algorithm with for original parameters.

  • PDF

Effect of Amplified Spontaneous Emission on the Gain Recovery of a Semiconductor Optical Amplifier

  • Lee, Hojoon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.32-39
    • /
    • 2018
  • The impact of the amplified spontaneous emission (ASE) on the gain recovery time of a bulk semiconductor optical amplifier (SOA) is investigated. The gain-recovery time is obtained by determining the time evolution of the gain, carrier density, and ASE in an SOA, after the propagation of a short pump pulse and continuous-wave (CW) probe of gain dynamics. In the simulation, a wide-band-semiconductor model, which can be characterized by the material gain coefficient over a wide wavelength range, is used, because the gain bandwidth of a practical SOA is very wide. The pump pulse and counterpropagating CW probe field are considered in the simulation, with the ASE noise spectrum equally divided.

Cryogenic Temperature Measurement Using Amplified Spontaneous Emission of Erbium-Doped Fiber (오븀 첨가 광섬유의 증폭 자발 방출을 이용한 저온 측정)

  • Lee, Yong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1992-1994
    • /
    • 2007
  • In this paper we propose a cryogenic sensor system which can measure the temperature at higher resolution at low temperature using temperature-dependent amplified spontaneous emission of erbium-doped fiber pumped by a 1480 nm laser diode. The measurement resolution of the sensor system could be enhanced through the modulation of injection current of the pump laser diode. The measurement resolution considering the fluctuation of the light source in the sensor system was ${\sim}0.4$ K in the room temperature regime and ${\sim}0.07$ K in the liquid nitrogen temperature regime.

Parameter extraction using the ASE spectrum Modelling for various DFB-type LDs (여러 가지 형태의 DFB 유형 레이저의 ASE 스펙트럼 모델링과 파라메터 추출)

  • Chae Gyoo-Soo;Kim Min-Nyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.46-51
    • /
    • 2006
  • We present simulation results for a method designed to extract key parameter values of DFB-type LDs based on ASE spectrum measurements. Comparisons were made between the given (actual) and the extracted (estimated) parameters, as well as the associated spectra, fur a variety of DFB-type LDs, and the two sets of results were found to be in excellent agreement.

  • PDF

Optical Coherence Tomography Based on a Continuous-wave Supercontinuum Seeded by Erbium-doped Fiber's Amplified Spontaneous Emission

  • Lee, Ju-Han;Jung, Eun-Joo;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • In this study, the use of a continuous-wave (CW) supercontinuum (SC) seeded by an erbium-doped fiber's amplified spontaneous emission (ASE) for optical-coherence tomography imaging is experimentally demonstrated. It was shown, by taking an in-depth image of a human tooth sample, that due to the smooth, flat spectrum and long-term stability of the proposed CW SC, it can be readily applied to the spectral-domain optical-coherence tomography system. The relative-intensity noise level and spectral bandwidth of the CW SC are also experimentally analyzed as a function of the ASE beam power.