• Title/Summary/Keyword: Amplatzer occluder

Search Result 13, Processing Time 0.02 seconds

The hybrid perventricular closure of apical muscular ventricular septal defect with Amplatzer duct occluder

  • Kim, Soo Jin;Huh, June;Song, Jin Young;Yang, Ji-Hyuk;Jun, Tae-Gook;Kang, I-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • Purpose: Apical muscular ventricular septal defects (MVSDs), especially in small infants, can be difficult to manage using surgical and percutaneous closure. An intraoperative perventricular procedure is a good option for closing apical MVSDs in small children with or without associated cardiac anomalies. We evaluated the results of hybrid perventricular closure of apical MVSDs performed using an Amplatzer duct occluder (ADO). Methods: We retrospectively reviewed the medical records of 5 patients who underwent hybrid perventricular closure of MVSDs with ADOs, from March 2006 to May 2011. The median patient age at the time of the procedure was 12 months (range, 25 days to 25 months), and the median body weight was 9.1 kg (range, 4.3 to 15 kg). Two patients had multiple ventricular septal defects (VSDs; additional perimembranous VSD in 1 patient and multiple MVSDs in the other) and 3 patients had associated cardiac anomalies; complete transposition of the great arteries in 1 patient and an atrial septal defect in 2 patients. All the procedures were performed on beating hearts, exception in 1 case. The ADO selected for the aortic side was at least 1 to 2 mm larger than the largest VSD in the left ventricle side. Results: The procedure was successful in all patients and each device was well positioned. During the median follow-up of 2.4 years, a small residual VSD was noted in 2 patients who had multiple VSDs and no leakage was seen in the other 3 patients. Conclusion: Perventricular closure of MVSD with an ADO is a good option for patients with apical MVSD. However, careful manipulation is important, especially in the case of small infants.

Late Migration of Amplatzer Septal Occluder Device to the Descending Thoracic Aorta

  • Kim, Hyo-Hyun;Yi, Gi-Jong;Song, Suk-Won
    • Journal of Chest Surgery
    • /
    • v.50 no.1
    • /
    • pp.47-49
    • /
    • 2017
  • Percutaneous closure of atrial septal defect (ASD) has become an increasingly common procedure. Serious complications of the procedure, such as cardiac migration, are rare, and usually occur <72 hours after device placement. In this report, we present the case of a patient who underwent successful surgical treatment for the migration of an ASD occluder device to the thoracic aorta 12 months after ASD closure.

Percutaneous Transcatheter Closure of Congenital Ventricular Septal Defects

  • Jinyoung Song
    • Korean Circulation Journal
    • /
    • v.53 no.3
    • /
    • pp.134-150
    • /
    • 2023
  • Ventricular septal defects (VSDs) are the most common kind of congenital heart disease and, if indicated, surgical closure has been accepted as a gold-standard treatment. However, as less-invasive methods are preferred, percutaneous device closure has been developed. After the first VSD closure was performed percutaneously by Lock in 1988, both techniques and devices have developed consistently. A perventricular approach for closure of muscular VSD in small patients and the closure of perimembranous VSD using off-label devices are key remarkable developments. Even though the Amplatzer membranous VSD occluder (Abbott) could not be approved for use due to the high complete atrioventricular conduction block rate, other new devices have shown good results for closure of perimembranous VSDs. However, the transcatheter technique is slightly complicated to perform, and concerns about conduction problems after VSD closure with devices remain. There have been a few reports demonstrating successful closure of subarterial-type VSDs with Amplatzer devices, but long-term issues involving aortic valve damage have not been explored yet. In conclusion, transcatheter VSD closure should be accepted as being as effective and safe as surgery but should only be performed by experienced persons and in specialized institutes because the procedure is complex and requires different techniques. To avoid serious complications, identifying appropriate patient candidates for device closure before the procedure is very important.

Transcatheter Closure of a Residual Shunt after Surgical Repair of Traumatic Ventricular Septal Defect (외상성 심실중격결손 수술 후 잔존하는 심실중격결손에 대한 중재적 심도자술을 이용한 폐쇄)

  • Jeong, Hee Jeong;Lim, Han Hyuk;Yu, Jae Hyun;Lee, Jae Hwan;Kil, Hong Ryang
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1143-1143
    • /
    • 2005
  • The traumatic ventricular septal defect (VSD) is a rare but potentially life threatening complication of chest wall injury. The traumatic VSD occurs in up to 4.5% of penetrating cardiac trauma. Most of the patients are usually operated on because of heart failure and/or significant left-to-right shunt. The feasibility of surgical repair under cardiopulmonary bypass may be affected by coexisting pulmonary, cerebral or other vascular injuries. Transcatheter closure of VSD is being considered as an alternative therapeutic modality to surgery in order to avoid the potential risk of cardiopulmonary bypass. We report a patient who underwent a successful transcatheter closure of VSD with an $Amplatzer^{(R)}$ VSD occluder. The patient had a residual VSD with significant left-to-right shunt after surgical repair of post-traumatic VSD using cardiopulmonary bypass.

Fistula of Ascending Aorta and Right Atrium Following Percutaneous Transcatheter Atrial Septal Defect Closure (경피적 카테타 심방중격결손 폐쇄술 후 발생한 상행 대동맥-우심방루)

  • Um Hong Gook;Seo Hong Joo;Kim Chong Whan;Kim Jun Seok;Lee Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.150-153
    • /
    • 2006
  • Percutaneous transcatheter closure of atrial septal defects as a therapeutic alternative in appropriate patients provides superior cosmetic results, is less invasive, and allows for shorter hospital stays. Unfortunately, however, such percutaneous procedures can be associated with catastrophic procedure complications that may require immediate surgical intervention. We report a case of aorta-to-right atrial fistula two months after transcatheter occlusion of an atrial septal defect by an Amplatzer septal occluder. Revealed by dyspnea, palpitation and hemolysis, this complication needed an emergency surgical operation. The fistula between the noncoronary Valsalva sinus of the aorta and the right atrium was repaired. The atrial septal defect was closed by patch. The cause of this serious complication appears to be erosion into the aorta by the right atrial disk.

Endovascular Treatment of Congenital Portosystemic Shunt: A Single-Center Prospective Study

  • Ponce-Dorrego, Maria-Dolores;Hernandez-Cabrero, Teresa;Garzon-Moll, Gonzalo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.2
    • /
    • pp.147-162
    • /
    • 2022
  • Purpose: To design a prospective study on endovascular closure of congenital portosystemic shunts. The primary endpoint was to assess the safety of endovascular closure. The secondary endpoint was to evaluate the clinical, analytical and imaging outcomes of treatment. Methods: Fifteen patients (age range: 2 days to 21 years; 10 male) were referred to our center due to congenital portosystemic shunts. The following data were collected prior to treatment: age, sex, medical history, clinical and analytical data, urine trimethylaminuria, abdominal-US, and body-CT. The following data were collected at the time of intervention: anatomical and hemodynamic characteristics of the shunts, device used, and closure success. The following data were collected at various post-intervention time points: during hospital stay (to confirm shunt closure and detect complications) and at one year after (for clinical, analytical, and imaging purposes). Results: The treatment was successful in 12 participants, migration of the device was observed in two, while acute splanchnic thrombosis was observed in one. Off-label devices were used in attempting to close the side-to-side shunts, and success was achieved using Amplatzer™ Ductus-Occluder and Amplatzer™ Muscular-Vascular-Septal-Defect-Occluder. The main changes were: increased prothrombin activity (p=0.043); decreased AST, ALT, GGT, and bilirubin (p=0.007, p=0.056, p=0.036, p=0.013); thrombocytopenia resolution (p=0.131); expansion of portal veins (p=0.005); normalization of Doppler portal flow (100%); regression of liver nodules (p=0.001); ammonia normalization (p=0.003); and disappearance of trimethylaminuria (p=0.285). Conclusion: Endovascular closure is effective. Our results support the indication of endovascular closure for side-to-side shunts and for cases of congenital absence of portal vein.

Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus (원통형 모양 동맥관의 경피적 폐쇄술에서의 Amplatzer Vascular Plug 의 사용)

  • Choi, Eun-Young;Jang, So-Ick;Kim, Soo-Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.9
    • /
    • pp.1035-1037
    • /
    • 2009
  • Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tubular-type PDAs are difficult to close with ordinary detachable coils or the Amplatzer Duct Occluder; thus, these lesions remain a challenge for transcatheter closure. We attempted to occlude a tubular-type PDA by using an oversized Amplatzer Vascular Plug, which allowed intraluminal packing of the ductus. By using this treatment method, PDA occlusion was achieved safely with an excellent final outcome. We suggest that this approach may be a good option for transcatheter closure of a tubular-type PDA.

Complications of transcatheter closure of atrial septal defects using the amplatzer septal occluder (심방 중격 결손의 경피적 폐쇄술 후 발생한 합병증에 관한 연구)

  • Jea, Seo Jin;Kwon, Hyo Jin;Jang, Gi Young;Lee, Jae Young;Kim, Soo Jin;Son, Chang Sung;Lee, Joo Won
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.401-408
    • /
    • 2008
  • Purpose : Transcatheter closure of atrial septal defects (ASD) is currently established therapy as an alternative to surgery. But rarely, complications are reported in some studies. We report early and intermediate term complications associated with transcatheter closure of atrial septal defects using the Amplatzer septal occluder (ASO). Methods : From June 2003 to May 2006, 64 patients underwent transcatheter closure of secundum ASD or patent foramen ovale using the ASO. The ratio of male to female was 1:2.4, the median age was 17 years (range: 2.6-64 years) and their median weight was 47.5 kg (range: 2.6-64 kg). Results : The median diameter of ASD measured with transthoracic or transesophageal echocardiography was 15 mm (range: 6-28 mm), the median balloon stretched diameter was 18 mm (range: 6.5-34 mm), and the median size of device was 19.5 mm (range: 6-36 mm), was little difference with balloon stretched diameter. There were 10 cases of complications: arrhythmia (2), device malformation (2), aorta to right atrial fistula (1), hemolytic anemia (1), mitral valve encroachment (1), malposition (1), residual shunt (1), and inferior vena cava perforation (1). Conclusion : Transcatheter closure of ASD using ASO is effective and safe therapy. However, significant complications such as aorta to atrial fistula, atrial erosion, or device embolization can happen, so an appropriate selection of patient and device in relevance to size and anatomy of ASD is important for successful closure.

Transvenous proximal closure of large congenital coronary arteriovenous fistula using the single Amplatzer vascular plug in a 3-year-old girl

  • Jang, Hae In;Choi, Young Earl;Cho, Hwa Jin;Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.2
    • /
    • pp.90-93
    • /
    • 2013
  • Congenital coronary arteriovenous fistulas (CCAFs) are rare coronary artery abnormalities in which blood is shunted into a cardiac chamber or great vessel. If the fistula itself is large and tortuous, it is generally recommended to occlude the fistula to prevent several complications. In approaches of transcatheter occlusion, the transvenous approach is preferred over the transarterial approach. The transvenous approach would enable the cannulation of a relatively larger catheter or sheath without potential damage to the femoral vessels or normal coronary arteries, which can occur in the transarterial approach. The transvenous approach may also minimize the blind pouch after releasing the devices. Herein, we report the success of transvenous proximal closure of a CCAF using an Amplatzer vascular plug (AVP) in a 3-year-old patient with cardiomegaly. Complete occlusion was achieved by a single AVP and thrombus formation of the distal aneurysmal portion of the fistula. We suggest that this strategy of closing the proximal end with a dilated fistula using a single AVP by the transvenous approach may be a good option in treating CCAFs in a young child.

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.