• Title/Summary/Keyword: Amount of air

Search Result 2,630, Processing Time 0.037 seconds

Refrigerant Amount Detection Technology for System Air-Conditioner Using Design of Experiment (실험계획법을 이용한 시스템에어컨의 냉매량검지 기술개발)

  • Lee, Soo-Young;Takeichi, Hisashi;Tae, Sang-Jin;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.26-32
    • /
    • 2010
  • This paper is suggesting a new technology for refrigerant amount detection of a system air-conditioner installed under various installation conditions. System air-conditioner was introduced to domestic market first in 2000. It consists of one or a series of outdoor units and a number of indoor units connected with single pipe line to the outdoor unit. The system can vary the capacity from 2.0 kW to 186 kW. For the system Installed under long and high-elevated condition, about 100 kg of refrigerant is charged in the whole system. In this paper, the new technology RAD (Refrigerant Amount Detection) with edge technology of refrigerant cycle control and measurement of a system air conditioner was developed and investigated for its application for the various installation conditions.

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

A Study on the Emission Estimate of Pollutants in Pusan (부산지역에서의 오염물 배출량 산정에 관한 연구)

  • 김유근;이화운;전병일;방종선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.361-367
    • /
    • 1996
  • In order to accurately predict air pollution concentration according to reduction of air pollutant emission, a numerical model is needed. And the total emission amount of air pollutants should be estimated to explain the air pollution phenomena. The characteristics of the emission amount from area, line, and point sources in Pusan were studied by using emission data during one year (1992). The result showed that the annual total emission amount of pollutant is about 299,744 tons in Pusan. The emission consists of 31.8% of $SO_2$, 48.4% of CO, 4.6% of HC, 11.0% of NOx and 4.1% of TSP, as well as 52.1% of line, 24.1% of area and 23.7% of point sources. The result also showed that emission amount becomes larger in winter than that of the others.

  • PDF

A Study on the using of the Ventilation System as the Method of Improvement of Air Quality in the Schools (학교건물의 공기질 개선을 위한 환기시스템 적용에 관한 연구)

  • Ahn, Chul-Lin;Kim, Jwa-Jin;Kum, Jong-Soo;Park, Hyo-Soon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • The purpose of this study concerns the improvement of air quality in school classrooms. Polluted indoor air is improved by efficient ventilation systems. So it is important to measure the amount of ventilation needed in classrooms. First, the amount of natural ventilation were measured through a tracer gas method. And we have established a heat recovery ventilation system from 4 cases of airflow in classrooms, and we have measured the change of $CO_2$ density. According to air quality measurements in the classrooms, the density of $CO_2$ is well above environmental standards which are acceptable. When the amount of ventilated airflow increases, indoor air quality is improved. It is surveyed that the most suitable amount of external inducted air is 770 CMH to satisfy $CO_2$ less than 1,000 ppm in classrooms. For improvement of air quality in classrooms, we must consider a suitable ventilation plan and installation of ventilation systems when constructing school buildings.

Quality Characteristics of Jeolpyun with Different Ratios of Loquat Leaf Powder (비파잎가루 첨가 비율에 따른 절편의 품질 특성)

  • Kang, Yang-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.25 no.5
    • /
    • pp.842-849
    • /
    • 2015
  • The purpose of this study was to determine the optimal mixing ratio of hot-air dried loquat leaf powder and optimum conditions for making Jeolpyun containing hot-air dried loquat leaf powder (LLP). Samples of Jeolpyun were prepared with different contents of hot-air dried LLP (0%, 3%, 6%, 9%, 12%) followed by analysis of chemical properties, moisture contents, color, mechanical quality characteristics, amylograph, and sensory tests. Chemical analysis showed that hot-air dried LLP consisted of 11.41% water, 8.34% crude protein, 1.90% crude fat, 7.74% crude ash, and 16.95% crude fiber, with $^{\circ}Brix$ of 2.07, and pH of 5.78. Moisture contents of samples ranged from 52.22 to 50.06%. L-value decreased with addition of hot-air dried LLP, whereas a-value increased with increasing amount of hot-air dried LLP, and no significant differences were observed regarding b-value. In the mechanical evaluation of physical properties, hardness deceased with increasing amount of hot-air dried LLP. The starting temperature amylograph of Jeolpyun was higher in samples with hot-air dried LLP than those without hot-air dried LLP. Set back was slower with increasing amount of hot-air dried LLP, an increasing amount of hot-air dried LLP made set back of Jeolpyun slower. In the sensory test, Jeolpyun with 6% hot-air dried LLP was the most preferred with less bitterness and proper softness, moisture and chewiness. Therefore, addition of 6% hot-air dried LLP to Jeolpyun made with rice flour showed the best overall preference. Based on the results of this experiment, samples with hot-air dried LLP showed slower hardening than those without hot-air dried LLP in textural changes during storage, and Jeolpyun with 6% hot-air dried LLP is expected to increase quality and preference of Jeolpyun.

Analysis of Factors Affecting Air Transport Trade between Korea and ASEAN Countries (한국과 아세안 국가간 항공운송무역 영향요인 분석)

  • Lim, Jae-Hwan;Kim, Young-Rok;Choi, Yun-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.27 no.4
    • /
    • pp.44-51
    • /
    • 2019
  • This study analyzes the trade patterns that occur between Korea and ASEAN countries through air transport, one of Korea's trade transport methods. In order to understand the detailed characteristics of the air transport sector, the dependent variables were analyzed by dividing them into amount and weight. As a result, the amount of exports, imports, and trade was proportional to GDP per capita representing income level, and inversely proportional to GDP representing national economic power. In terms of air transport weight, exports, imports and trade were all proportional to GDP representing economic power and inversely proportional to GDP per capita representing income levels. In addition, the national area acted as a factor to reduce the trade volume, and the number of airports and inland countries did not show any significant results.

Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain (에어커튼형 주방 레인지후드의 배기 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

Precise Air-Fuel Ratio Control on Transient Conditions with the PC-ECU in SI Engine (PC-ECU를 이용한 SI 기관의 비정상상태 정밀공연비 제어)

  • Yoon, S.H.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.9-16
    • /
    • 2000
  • In a SI engine, three-way catalyst converter has the best efficiency when A/F ratio is near the stoichiometry. The feedback control using oxygen sensors in the commercial engine has limits caused by the system delays. So it is necessary to control fuel quantity in accordance with intake air amount in order to reduce exhaust emission and improve the specific fuel consumption. Precise A/F ratio control requires measurement of air amount with respect to the cylinder and injection fuel according to the air amount In this paper, we applied nonlinear fuel injection model and developed the algorithm of A/F ratio control. This algorithm includes the methods of measurement of transient air mass flowing into each cylinder, of calculation of injection pulse width for measured air mass, and the method of feedback and engine control by using lambda sensor. Also we developed control program for IBM-PC by using C++ Builder, and tested it in the commercial engine.

  • PDF

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

Comparison of basic bodice block for adults women by 3D simulation - focus of the DC Suite Program - (3차원 시뮬레이션을 활용한 성인여성용 길 원형 비교 연구 - DC Suite Program을 중심으로 -)

  • Cha, Sujoung;Kang, Yeonkyung
    • Journal of Fashion Business
    • /
    • v.17 no.2
    • /
    • pp.63-81
    • /
    • 2013
  • A Study using compare and analyze about differences among three patterns(shape and size of pattern, fitting and amount of air gap and so on) through 3D simulation. This study use 3D simulation program, DC Suite version 3.0. The results are as a follows: The results of estimation about total appearance, the pattern of Bunka is best of all pattern about total fitting and silhouette of front and back side. The pattern of armstrong and on&on stand low in estimation. As the total fitting, the pattern of Bunka is 4.40, the pattern of Armstrong is 2.60 and the pattern of On&on is 1.60. The result show better pattern of Bunka than pattern of Armstrong and On&on. When we examine about space between body and cloth, the pattern of Bunka is best. The pattern of Armstrong don't have problems about back side but front side have some problem of getting loose. Because it only have a waist dart so dart size is too big. The pattern of On&on have so much space because it don't have a waist dart. On the amount of air gap, the pattern of Bunka squash up body so it have the amount of air gap 0.08 at bust circumference and underbust circumference. Next is the pattern of Armstrong, amount of air gap is 0.14 at bust circumference and 0.23 at underbust circumference. The pattern of On&on's amount of air gap is 0.30 at bust circumference and 0.37 at underbust circumference. So the pattern of Bunka is bodice block of the best closing adhesion and the On&on is a loose-fitting pattern.