• 제목/요약/키워드: Amount of air

검색결과 2,630건 처리시간 0.03초

인버터 열펌프의 주파수 및 냉매봉입량 변화에 따른 시스템 성능특성의 실험적 연구 (An Experimental Study on the Performance of an Inverter Heat Pump with a Variation of Frequency and Refrigerant Charging Amount)

  • 최득관;김경천;김주상
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.66-71
    • /
    • 2001
  • In the air-conditioning industry, the refrigerant charging amount is one of the most important parameters affecting the energy efficiency ratio of heat pumps. An experimental study was performed on the characteristics of an inverter driven air-to-air heat pump system with a variation of compressor frequency and charging amount of refrigerant. The frequency was altered from 40Hz to 70Hz and the charging amount was changed from 1.6kg to 2.8kg in tests. The variation of performance was measured with switching of the expansion valve on each frequency and charging amount. All the tests were performed at the Korean Standard and test conditions of the air conditioners. As results, it was found that there existed the charging amount and the level of the suction gas superheat which provided the highest energy efficiency ratio at all the frequency bands.

  • PDF

시스템에어컨의 냉매충전량에 따른 사이클 운전특성 및 냉매량 판독 프로그램 개발 (Effect of Charged Refrigerant Amount on Operating Characteristics and Development of Detecting Program for System Air-Conditioner)

  • 태상진;김훈모;문제명;김종엽;권형진;조금남
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.427-432
    • /
    • 2005
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant were ranged from 60% to 140% with 10% increasement. Fuzzy algorithm were emploeed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. membership function were determined for whole ranges of experimentally measured data and rulebase were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.

  • PDF

중유의 연소에 필요한 소요공기량과 발생가스량의 산식에 관한 연구 (A Study on the Calculation Formulae of Required Air and Burning Gas Amount of Heavy Fuel Oil)

  • 이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.34-40
    • /
    • 1982
  • The characteristics of typical 17 kinds of fuel oils are studied to fine the calculation formulae for the required amount of air and the combustion gas amount. 1) The author's calculation formulae are as follows; (1) Theoretically required amount of air (2) Theoretical amount of combustion gas 2) Theoretical amount of the required air in combustion and combustion gas of fuel oils are always estimated less with Rosin's formula than with author's one. 3) Theoretical amount of the required air and the amount of combustion gas of fuel oils are more reasonable with author's formula than Rosin's one in comparison with results of actual analysis.

  • PDF

배압에 따른 에어커튼형 냉동용 전시케이스의 성능변화 (Performance Variation of the Refrigerated Display Case with Air Curtain in Accordance with Back Pressure Condition)

  • 성순경;안교철
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.578-584
    • /
    • 2013
  • Vertical open display cases are widely used in shopping malls, supermarkets, or retail stores to sell frozen and refrigerated products. Open display cases use air curtains to maintain a reasonable temperature within the storage space, prevent insects from breaking in, and reduce energy usage. In this research, computational fluid dynamics was used to find the optimal condition for reducing energy by considering various conditions such as discharge speed or temperature of air curtains. Results of the study showed that the amount of energy consumed in the display cabinet is influenced by the discharge speed and temperature of the slots installed on the upper area and the amount of air supplied to the storage area inside the shelf. This shows that the amount of discharged air supplied from the storage area influences the formation of air curtain and also the amount of energy consumption. As a result of this study, we learned that the amount of energy used can be reduced by increasing the amount of discharged air within the storage area and enhancing back pressure.

공랭식 미소유로 응축기의 R410A 충전량 예측에 관한 수치적 연구 (A Numerical Study on R410A Charge Amount in an Air Cooled Mini-Channel Condenser)

  • 박창용
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.710-718
    • /
    • 2010
  • A numerical study was performed to predict refrigerant charge amount in a mini-channel condenser for a R410A residential air-conditioning system. Multi-channel flat tubes with 12 mini-channels of 1.17 mm average hydraulic diameter for each tube were applied to the condenser. The condenser consisted of 3 passes, and the first, second, and third pass had 44, 19, and 11 tubes, respectively. Each pass was connected by a vertical header. In this study, the condenser was divided into 410 finite volumes, and analyzed by an $\varepsilon$-NTU method. With thermophysical properties and void fraction models for each volume element, the R410A amount distribution and a total charge amount in the condenser were calculated. The predicted total charge amount was compared with the experimentally measured charge amount under a standard ARI A condition. The developed model could predict the charge amount in the mini-channel condenser within prediction errors from -23.9% to -3.0%. Air velocity distribution at the condenser face was considered as non-uniform and uniform by the simulation model, and its results showed that the air velocity distribution could significantly influence the charge amount and vapor phase distribution in the condenser.

소형 냉각식 천정형 제습기의 증발기 전면 풍속에 관한 연구 (A Study on Evaporator Front Air Velocity of Small Refrigeration Ceiling Dehumidifier)

  • 김진철;정경태;금종수;김동규
    • 수산해양교육연구
    • /
    • 제28권4호
    • /
    • pp.1107-1113
    • /
    • 2016
  • In the environment with high humidity causes negative influence on human's body and living condition. As the weather gets more humid, people's interest of dehumidifier for household arising recently. The cooling dehumidifier dehumidify the air by using refrigeration cycle technology which means it removes vapor by let the humid air pass through the cold surface. The amount dehumidified of refrigerating method dehumidifier affected by multiple factors. However, the refrigerating method dehumidifier for household in the market controls pass wind velocity technology to adjust the amount of dehumidification. As the pass wind velocity increases, the amount of wind increases hence the heat exchange amount increases accordingly. However, the amount of dehumidification decreases because the temperature difference between the air and vaporization decreases. Therefore, simply by increasing air velocity does not increase the amount of dehumidification. This research examined the effect of air velocity out of all variety of factors to the amount of dehumidification for refrigerating method dehumidifier.

화재 시뮬레이션(FDS)을 이용한 거실제연설비 개선에 관한 연구 (A Study on Improvenment of Livingroom Smoke-control System using the FDS)

  • 김미선;백은선
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.26-34
    • /
    • 2017
  • 본 논문은 거실제연설비의 인접구역 상호제연방식의 성능 확인 및 향상을 위한 논문으로써 국가화재안전기준(NFSC)과 NFPA 연기제어에 관한 규정을 비교 분석하였다. 분석방법은 화재 시뮬레이션(FDS)을 통해 모델링을 실시하여, 급기량 변화, 제연경계의 폭, 화재실내 가연물 변화, 유입공기의 풍속차이를 통해 이루어졌다. 그 결과 청결층 확보를 위해 급기량을 배출량 이하로 하였을때 화재실에서의 청결층 확보에 유리한 것으로 나타났으나 급기실에서는 급기량을 배출량 이상으로 하였을때 청결층 확보에 유리한 것으로 나타났으며, 제연경계의 폭이 길어질수록 성능 확보에 유리한 것으로 나타났다. 또한 가연물의 종류에 따라 급기량과 배출량을 고려해야 하며, 공기유입구 풍속은 급기량을 감소시킴과 동시에 공기유입구 풍속을 낮게 하므로써 화재실의 청결층 확보에 유리한 것으로 나타났다.

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발 (Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm)

  • 태상진;최창식;김훈모;조금남;문제명;김종엽;권형진
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

조리대에 급기구를 가진 주방 레인지후드의 배기 성능 (Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table)

  • 성순경
    • 설비공학논문집
    • /
    • 제28권12호
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.