• 제목/요약/키워드: Ammonia absorption heat pump

검색결과 12건 처리시간 0.361초

확산형 흡수식 냉동시스템의 기포펌프 성능실험 (Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System)

  • 이재효;정의갑;윤재호;정의갑
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

플레이트-휜형 흡수기의 흡수성능에 대한 연구 (The Study on Absorption Performance of a Plate-Fin Type Absorber)

  • 강인석;김남진;김종보
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.557-563
    • /
    • 2001
  • Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.

  • PDF

암모니아 흡수식 열펌프의 Falling Film Type 흡수기에 대한 수학적 모델링 및 수치모사에 관한 연구 (Mathematical modeling and numerical simulation studies for falling film type absorber in ammonia absorption heat pump)

  • 이찬호;김성현;현재천
    • 청정기술
    • /
    • 제7권2호
    • /
    • pp.151-159
    • /
    • 2001
  • 암모니아 흡수식 열펌프의 falling film type 흡수기에 대한 수학적 모델링 및 수치모사 연구를 수행하였다. 기존의 수학적 모델에 열역학적 물성을 온도의 함수로 적용하여 수치모사를 수행하였고 이로부터 얻은 결과를 실험결과와 비교함으로써 모델의 성능이 향상되는 것을 확인하였다. 그리고 개발된 모델을 이용하여 냉각수의 유량과 온도가 흡수기내에서 일어나는 열 및 물질전달에 미치는 영향을 평가하였다. 수치모사 결과로부터 냉각수 온도가 낮을수록 유량이 증가할수록 열 및 물질전달 효율이 증가하는 것을 알 수 있었다.

  • PDF

GAX 암모니아 흡수식 열폄프의 발생기 일체형 정류기의 열 및 물질전달 해석 (Heat and mass transfer characteristics of generator combined rectification system of the GAX ammonia absorption heat pump)

  • 윤상국
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.431-439
    • /
    • 1999
  • A generator-GAX combined rectification system of an ammonia absorption heat pump was investigated to get the optimum design values. The mass and heat transfer phenomena of the rectification system were analysed. The number of column plates, equilibrium temperature of solution on each plate and flow rates of solution and vapor generated were predicted. The characteristics of mass and heat transfer of the generator-GAX combined rectification system, i.e. concentration difference of leaving solution and vapor on each column plate, were found to be mainly governed by the pressure of generator, reflex ratio and temperature difference of analyser coolant. The number of rectification column plates for each different pressure in generator was obtained. The optimum locations for installing the feeder from solution-cooled absorber and GAX desorber in generator were predicted. The improvement of COP was followed by the increase of the rectifier efficiency and the number of column plate, and the decrease of reflex ratio.

  • PDF

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

암모니아-물 기포분사형 흡수과정에서의 흡수열 제거를 위한 열전달 특성 연구 (A Study on Heat Transfer Characteristics for Removal of Absorption Heat in Absorption Process of Ammonia-Water Bubble Mole)

  • 이재철;이기봉;전병희;이찬호;하종주;김성현
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.273-280
    • /
    • 2001
  • 흡수기는 흡수식 열펌프 시스템에서 중요한 구성요소일 뿐만 아니라 흡수기의 성능은 전체 시스템에 중요한 영향을 미친다. 본 연구에서는 기포분사형 흡수기에서의 암모니아기체의 흡수열의 효과적 제거를 위한 냉각수 방향으로의 열전달에 대해 실험적 연구를 수행하였다. 흡수기에 유입되는 암모니아 기체의 유속, 암모니아 수용액의 유속, 농도, 온도, 흡수기의 지름, 높이, 기체와 용액의 유입 방향등 여러 가지 변수에 대하여 열전달 성능의 특성을 살펴본 결과, 기체의 주입량, 용액의 주입량 증가는 열전달 성능 향상에 기여하며, 용액의 온도나 농도의 상승은 열전달 성능에 방해요소로 작용하였으며 흐름방향이 향류인 경우 열전달 성능에 향상이 있었다. 본 실험의 데이터를 이용하여 상관관계식을 유도하여 열전달에 대한 복잡한 관계를 일반화 하였다.

  • PDF

산업폐수열원 이용 증기압축식/흡수식 하이브리드 히트펌프 시스템의 시뮬레이션 (Simulation of Compression/Absorption Hybrid Heat Pump System using Industrial Wastewater Heat Source)

  • 백영진;박성룡;장기창;라호상
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1117-1125
    • /
    • 2004
  • In this study, in order to utilize the waste heat of industrial wastewater in the range of the relatively low temperature of 40~5$0^{\circ}C$ as a heat source, a hybrid heat pump system was considered by computer simulation method. In the simulation, an absorber, desorber and solution heat exchanger were modelled by UA values while a compressor and pump performance were specified by an isentropic efficiency. Simulation results show that the performance of hybrid heat pump can be up to 80% higher than that of conventional R134a heat pump when it makes a process hot water of 9$0^{\circ}C$ while the wastewater is cooled down to 2$0^{\circ}C$. As the absorber pressure increases, the system performance and deserter pressure increase with a favorable effect of a compressor discharge gas temperature drop.

증기압축식/흡수식 하이브리드 히트펌프 사이클에 관한 최적화 연구 (Optimization Study of the Compression/Absorption Hybrid Heat Pump Cycle)

  • 전관택;박춘건;정동수
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.48-58
    • /
    • 2001
  • For the past few decades the vapor compression cycle with a solution circuit (VCCSC) has been known to provide high efficiency and variable capacity. In this study performance of a VCCSC cycle is examined through computer simulation. In the simulation heat exchangers were modelled by specifying UA or effectiveness values while the compressor performance was specified by an isentropic efficiency. Aqua/ammonia solution was chosen as the working fluid which can be used in the high temperature range. The results show that there exists an optimum operation condition which is dependent upon the temperatures of the external heat transfer fluids(HTFs). Besides the HTF\`s temperature, the maximum system pressure and the size of the solution heat exchanger are shown to have an influence on the optimum operation condition. Finally, as compared to a simple vapor compression heat pump with HFC134a, the COP of the VCCSC is shown to be 2∼22% higher.

  • PDF

화학식 냉동기의 성능 및 반응기 거동에 관한 연구 (A Study on Performance and Reactor Behavior of Chemical Refrigerator)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • 에너지공학
    • /
    • 제6권1호
    • /
    • pp.87-95
    • /
    • 1997
  • 금속염화물과 암모니아간의 가역반응을 이용한 화학열펌프는 비프레온계 냉동 냉장시스템으로서 환경규약의 제한이 없고 가스, 전기 및 산업폐열 등 다양한 구동열원을 사용할수 있으며 축열에 의한 에너지 저장이나 산업공정에서의 대용량 에너지관리 시스템 등 응용분야가 다양한 장점을 갖고 있다. 통상 소규모의 실험실 장치에서 파일롯트 플랜트(pilot plant)로 전환하는 과정에서 시스템의 성능에 대한 해석이 필요하며 화학반응기의 거동에 대한 컴퓨터 모사도 필수적이다. 따라서 본 연구에서는 작동조건에 따라 화학식 냉동기 성능계수가 어떻게 변하는지를 예측하였고 반응기 모델링에 의한 동적모사를 수행하여 반응기의 온도거동, 작동조건에 따른 전화율 변화, 반응혼합물의 제조변수가 냉동기 성능에 미치는 영향 등을 고찰하였다.

  • PDF