• 제목/요약/키워드: Ambient Air

검색결과 1,456건 처리시간 0.026초

열펌프-잠열축열 온돌 시스템 연구 (A Study on the Heat Pump-Latent Heat Storage Type)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • 제26권4호
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

열(熱)펌프시스템에서 각종(各種) 설계인자(設計因子)들에 따른 응축기(凝縮器)의 최적설계(最的設計)에 관한 연구(硏究) (A Study on the Optimization of Condenser according to Design Factors in Heat Pump System)

  • 이영수;김남국
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.408-417
    • /
    • 1988
  • This study optimized the condenser dimension of heat pump system with the heat sources which are solar irradiation and ambient air. At first, the author selected the principal design factors influencing the performance of heat pump system. And the author considered the variation of condenser dimension according to the variation of the selected design factors, that is, ambient air temperature, condenser temperature, degree of superheating, degree of sub-cooling and irradiation. As a result this study, among refrigerants R12, R22 and R500, refrigerant R22 has more heating output than R12 and R500, and the coefficient of performance on this heat pump system is not greatly influenced by the degree of superheating and degree of sub cooling. The ambient air temperature is below $5^{\circ}C$ at balance point and the optimal tube length of condenser dimension is about 3.8 m. Also the author gained the optimal design diagram for the optimization of condenser dimension according to various design factors.

  • PDF

스파크점화직분식 CNG의 점화성 및 연소화염 특성에 대한 연구 (An Experimental Study on the Ignition Probability and Combustion Flame Characteristics of Spark-Ignited Direct-Injection CNG)

  • 황성일;정성식;염정국;전병열;이진현
    • 한국분무공학회지
    • /
    • 제21권1호
    • /
    • pp.37-46
    • /
    • 2016
  • For the SI engines, at only full load, the pumping loss has a negligible effect, while at part load conditions, the pumping loss increases. To avoid the pumping loss, the spark-ignited engines are designed to inject gasoline directly into the combustion chamber. In the spark-ignited direct-injection engines, ignition probability is important for successful combustion and the flame propagation characteristics are also different from that of pre-mixed combustion. In this paper, a visualization experiment system is designed to study the ignition probability and combustion flame characteristics of spark-ignited direct-injection CNG fuel. The visualization system is composed of a combustion chamber, fuel supply system, air supply system, electronic control system and data acquisition system. It is found that ambient pressure, ambient temperature and ambient air flow velocity are important parameters which affect the ignition probability of CNG-air mixture and flame propagation characteristics and the injected CNG fuel can be ignited directly by a spark-plug under proper ambient conditions. For all cases of successful ignition, the flame propagation images were digitally recorded with an intensified CCD camera and the flame propagation characteristics were analyzed.

승온조건의 SEAS(surfactant-enhanced air sparging) 기술을 이용한 대수층 NAPL(n-decane)의 휘발제거 (Removal of NAPL from Aquifer Using Surfactant-enhanced Air Sparging at Elevated Temperature)

  • 송영수;권한준;김헌기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권6호
    • /
    • pp.87-94
    • /
    • 2009
  • 대수층에 존재하는 휘발성 오염물질을 제거하는 새로운 공법으로서 Surfactant-enhanced air sparging(SEAS)은 지하수의 표면장력을 감소함으로써 지하수 폭기효율의 증대를 도모한다. 그러나 SEAS기술도 기본적으로 오염물질의 휘발에 의한 물질이동에 의존함으로써 휘발성이 낮은 오염물질의 제거에는 매우 제한적이다. 본 연구는 승온된 조건에서 SEAS기술을 준휘발성 물질인 n-decane에 대하여 적용함으로써 SEAS기술의 확장여부를 시험하였다. 지하수 폭기실험은 내경 5 cm, 길이 80 cm의 1차원 토양(모래)컬럼을 사용하여 실시하였다. 실험은 총 3회 실시하였으며, 상온에서 증류수로 포화된 조건에서 1회, 상온($23^{\circ}C$)에서 음이온계 계면활성제(sodium dodecylbenzene sulfonate, SDBS) 수용액으로 포화된 조건에서 1회(상온 SEAS), 그리고 승온상태($73^{\circ}C$)에서 SDBS수용액으로 포화된 조건에서 1회(승온 SEAS) 실시하였다. 계면활성제가 적용된 경우의 폭기에 의한 공기포화율(57%)은 증류수로 포화된 조건의 공기포화율(10%)보다 높게 측정되었다. 승온 및 상온조건에서의 공기포화율은 거의 차이가 없었으나 n-decane의 제거속도는 현저한 차이를 나타내었다. 토양유출 가스에 포함된 n-decane의 농도는 상온조건에 비하여 승온조건에서 10배 이상 높았으며, 따라서 제거속도도 10배 이상의 차이를 나타내었다. 본 연구 결과에 따라 상온에서 휘발성이 낮으나 수 십도의 온도상승으로 증기압이 획기적으로 늘어날 수 있는 준휘발성 물질에 대하여 SEAS 기술이 효과적으로 응용될 수 있을 것으로 보인다.

Air pollution and hospital admissions for chronic obstructive pulmonary disease: are their potentially sensitive groups?

  • Tsai, Shang-Shyue;Yang, Ya-Hui;Liou, Saou-Hsing;Wu, Trong-Neng;Yang, Chun-Yuh
    • Advances in environmental research
    • /
    • 제1권1호
    • /
    • pp.57-68
    • /
    • 2012
  • Recent studies showed that air pollution is a risk factor for hospitalization for chronic obstructive pulmonary disease (COPD). However, there is limited evidence to suggest which subpopulations are at higher risk from air pollution. This study was undertaken to examine the modifying effect of specific secondary diagnosis (including hypertension, diabetes, pneumonia, congestive heart failure) on the relationship between hospital admissions for COPD and ambient air pollutants concentrations. Hospital admissions for COPD and ambient air pollution data for Taipei were obtained for the period from 1999-2009. The relative risk of hospital admissions for COPD was estimated using a case-crossover approach. None of the secondary diagnosis we examined showed much evidence of effect modification.

태양열공기가열기의 성능실험 (Performance of Solar Air Heaters)

  • 차종희;송희열
    • 대한설비공학회지:설비저널
    • /
    • 제5권2호
    • /
    • pp.91-97
    • /
    • 1976
  • This study was concerned with performance of 2 types of black painted solar air heaters, one is finned type better, the other is mesh type. The performance test of heaters was made under the different operating conditions during winter season of December in Seoul area. It was analized and discussed by comparing the overall efficiency of 2 solar heaters at the same mass flow rate and ambient temperature. Experimental results show that finned type solar heater is better than mesh type from the point of view of design and heat removal efficiency. Finned-type solar air heater supplies hot air up to 30 degree centigrade above ambient temperature with an overall efficiency of 47 percent whilemesh type was 44 percent.

  • PDF

캐니스터와 Tedlar-bag 시료채집법을 이용한 대기 중의 휘발성유기황화합물의 측정 (Measurement of Volatile Organic Sulfur Compounds in Ambient Air by Canister and Tedlar-bag Sampling Method)

  • 전선주;허귀석
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.417-428
    • /
    • 1999
  • The measurement of VOSCs(volatile organic sulfur compounds) in the air is nowadays a very important environmental research field. It is, however, very difficult because the concentration of the VOSC in ambient air is usually very low and the high reactivity makes it difficult to keep in container without loss of recovery. In this study, sampling method with cryogenic preconcentration is evaluated for analysis of atmospheric VOSC such as $CH_3SH,\;CH_3CH_2SH,\;CH_3SCH_3,\;CS_2,\;CH_3SSCH_3,\;CH_3SCH_2SCHA_3,\;and\;C_2H_5SSC_2H_5$ analyzed by GC-MS or GC-FID. Repeatabilities of measurement accompanied with preconcentration for 3-successive runs were in the range of 0.2~1.0% as a relative standard deviation. Stabilities up to 13 days were measured in 6 L canister and 10 L tedlar bag filled with VOSCs in ppb level. Higher stability was observed in tedlar bag as compared to canister with glass coated inner walls, and thiol compounds show dramatic losses in canister within 2~3 days. It is found that recovery over 70% was obtained in a week for all tested VOSCs when the compounds from ambient air matrix were stored in tedlar bag. It is also found that the stabilities of VOSCs are depending on humidity and coexisting compounds in matrix gas due to sample adsorption onto inner surface and reactivity. The results indicate the possibility and limitations of VOSC analysis in ambient air using container sampling method with cryogenic preconcentration.

  • PDF

과실부위 송풍이 참외의 품질 및 발효과 발생에 미치는 영향 (Effect of Forced-air circulation of ambient Fruit on the Occurrence Fermented-fruit and Fruit Quality of Oriental Melon(Cucumis melo L. var. makuwa Mak.))

  • 연일권;최성국;최부술;신용습
    • 생물환경조절학회지
    • /
    • 제8권2호
    • /
    • pp.99-107
    • /
    • 1999
  • 참외 과실부위 송풍이 칼슘흡수와 발효과 발생에 미치는 영향을 구명하기 위하여, 풍속 0.3m/sec로 10시부터 13시까지 1일 3시간 과실부위에 송풍을 하였다. 송풍은 착과 10일후, 20일후, 30일 후부터 수확까지 송풍처리구와 무송풍구로 나누어 비교한 결과, 과중은 착과 30일후 송풍처리에서 가장 무거웠으며, 과육두께는 착과 30일후 송풍구에서 가장 두꺼웠다. 과실의 경도는 착과 10일후 송풍구에서 가장 높았으며, 과육 및 태좌의 당도는 착과 20일 후 송풍 처리에서 가장 높았다. 과실의 L값은 착과 10일후 송풍구, a값 및 Y. I값은 착과 30일후 송풍구에서 좋아 무송풍에 비하여 송풍 처리에서 과실의 착색이 우수하였다. 과육 및 태좌의 Ca 함량은 송풍처리에 비하여 무송풍처리에서 많았으나, 발효과 발생은 송풍처리구에서 적었다. 특히 착과 20일후 송풍처리구에서 발효과율 및 기형과율의 발생이 적었고 상품과율은 증가하였다.

  • PDF

공단지역 대기 중 PCBs의 오염농도 및 발생원 추정 (Source Estimation and Concentration Levels of PCBs in Ambient Air of an Industrial Area)

  • 김경수;송병주;박석운;김종국
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.385-389
    • /
    • 2005
  • 공단지역 대기 중 PCBs의 오염 수준을 조사하기 위하여 시화 및 반월 공단 지역에서 PCBs를 측정하였다. 총 농도 및 WHO-TEQ 농도는 각각 $2,080{\sim}5,820$ (중앙값 2,760) $pg/m^3$$0.19{\sim}1.01$ (중앙값 0,42) $pgTEQ/m^3$으로 검출되었다. 동족체 조성에 있어서는, 고염소화 동족체(6염화물에서 10염화물까지)의 존재 비율이 다른 지역의 일반 대기시료에 비하여 높았다. 측정된 대기 시료를 PCBs의 발생원으로 알려진 소각로 배가스 및 Aroclor시료와의 연관성을 조사하기 위하여 군집분석을 행하였다. 각 동족체 중 각각의 이성질체의 비율을 입력변수로서 이용하였다. 그 결과, 공단지역 대기 시료는 발생원으로 입력한 시료들과는 거리가 먼 하나의 그룹으로 형성되었다. 이것은 시화와 반월 공단 지역의 대기 시료는 지금까지 알려진 소각로 배가스나 Aroclor의 영향보다는 지역적인 특정 발생원의 영향을 받고 있음을 시사한다. 이러한 결과는 이성질체의 패턴 비교를 통해서도 알 수 있었다. 따라서, 이 지역의 PCBs 발생원을 밝히기 위해서는 추가적인 모니터링 조사가 필요할 것으로 사료된다.