• 제목/요약/키워드: Ambient Air

검색결과 1,460건 처리시간 0.027초

경기도 환경대기중 휘발성유기화합물의 오염실태 조사연구 (III) (A Study on the VOCs Contamination of Ambient Air int Kyonggi-do Area (III))

  • 김종보;김종찬;최승석;임흥빈;최양희;이수문
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.63-70
    • /
    • 2002
  • We investigated the concentration degree of VOCs for ambient air in the air environment control area of Kyonggi-do in 2001. The VOCs showing higher concentration were in the ascending order of Toluene > n-Butane > 1-Butene > Benzene > n-Hexane. The concentration distribution ratio mentioned above showed almost same pattern in each city. The relative concentration ratio of Benzene, Toluene, Ethylbenzene, Xylenes which are aromatic VOCs were 1 : 6.3 : 0.6 : 1.6. It was similar to the pattern in 1999 but different from the pattern in 2000. In the aspect of seasons, the highest B.T.E.X concentration was indicated in fall and in the aspect of areas, the higher concentration showed in the ascending order of Buchon > Ansan > Kwangmyong > Shihung > Sungnam. The average concentration of target VOCs for ambient air in the air environment control area of Kyonggi-do showed lower concentration than the metropolis of Seoul but higher concentration than Kwang-ju city and Dae-gu city. The amount of total VOCs was increasing, comparing with it last year and the more increasing tendency is anticipated so that it will need to establish the proper regulative criteria.

Applying policy and health effects of air pollution in South Korea: focus on ambient air quality standards

  • Ha, Jongsik
    • Environmental Analysis Health and Toxicology
    • /
    • 제29권
    • /
    • pp.11.1-11.7
    • /
    • 2014
  • Objectives South Korea's air quality standards are insufficient in terms of establishing a procedure for their management. The current system lacks a proper decision-making process and prior evidence is not considered. The purpose of this study is to propose a measure for establishing atmospheric environmental standards in South Korea that will take into consideration the health of its residents. Methods In this paper, the National Ambient Air Quality Standards (NAAQS) of the US was examined in order to suggest ways, which consider health effects, to establish air quality standards in South Korea. Up-to-date research on the health effects of air pollution was then reviewed, and tools were proposed to utilize the key results. This was done in an effort to ensure the reliability of the standards with regard to public health. Results This study showed that scientific research on the health effects of air pollution and the methodology used in the research have contributed significantly to establishing air quality standards. However, as the standards are legally binding, the procedure should take into account the effects on other sectors. Realistically speaking, it is impossible to establish standards that protect an entire population from air pollution. Instead, it is necessary to find a balance between what should be done and what can be done. Conclusions Therefore, establishing air quality standards should be done as part of an evidence-based policy that identifies the health effects of air pollution and takes into consideration political, economic, and social contexts.

대규모 도시개발사업에 대한 대기질 평가 사례 연구 (A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development)

  • 김상목;이상훈;박근형;우재균;구윤서;김성태;한진석
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.

Air stable n-type organic field effect transistors using a perfluoropolymer insulator

  • Jang, Jun-Hyuk;Kim, Ji-Whan;Park, Noh-Hwal;Kim, Jang-Joo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.276-279
    • /
    • 2008
  • Air stable n-type organic field effect transistors (OFETs) based on CB60B are realized using a perfluoropolymer as the gate dielectric layer. The devices showed the field-effect mobility of $0.05\;cm^2P/V\;s$ in ambient air. Replacing the gate dielectric material by $SiO_2$ resulted in no transistor action in ambient air. Perfluorinated gate dielectric layer reduces interface traps significantly for the n-type semiconductor even in ambient air.

  • PDF

Trend and Characteristics of Ambient Particles in Seoul

  • Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • 제1권1호
    • /
    • pp.9-13
    • /
    • 2007
  • Various aspects of the air quality problems caused by ambient particles in and around the city of Seoul are discussed. First, the trend of the air quality in Seoul over time is investigated along with the types and quantities of energy consumption in Seoul. It was found that the general air quality in Seoul has improved over the last twenty years because of a change in the primary fuel used in Korea. However, the visibility in Seoul, a representation of the ambient particle concentration, is still worse than in other cities in Korea. In the air around Seoul, secondary particle generation might be as important as particles directly emitted from within the city or transported from outside.

Monitoring of the Distribution of Ambient Air Particles in Seoul Using a Cascade Impactor and the Particle Toxicity

  • Park, Eun-Jung;Kim, Dae-Seon;Park, Kwang-Sik
    • Environmental Analysis Health and Toxicology
    • /
    • 제25권2호
    • /
    • pp.99-109
    • /
    • 2010
  • The distribution of ambient air particles varies according to climate, industries, and other sources. In this study, ambient air particles (less than 12.1 ${\mu}m$) were monitored from February to August, 2007 as 12 different fractions sorted by a cascade impactor. Particles in the size range from 0.33 ${\mu}m$ to 0.76 ${\mu}m$ comprised the main fraction of ambient air particles in Seoul, Korea. On the day of an Asian dust event, the particle fraction size increased to 1.25~2.5 ${\mu}m$. The different sized particle fractions were also monitored for metals and were found to contain toxic heavy metals including Pb, Cd, Hg, Cr and As. Particle preparations were significantly cytotoxic when exposed to cultured BEAS-2B cells. Microarray analysis of the treated cells indicated a significant up-regulation of a number of genes associated with oxidative stress, including metallothionein, heme oxygenase-1, heat shock protein 70, and NAD(P)H dehydrogenase-1.

비교 측정을 통한 PM-10 질량농도의 오차 분석 (Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study)

  • 정창훈;조용성;황승만;정용국;유재천;신동석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

1980년대 초 서울의 실내외 대기질 수준 - Sherwood 교수의 측정 자료 활용 (Historical Data on Indoor and Outdoor Air Quality in Seoul, Korea)

  • 이기영
    • 한국환경보건학회지
    • /
    • 제39권1호
    • /
    • pp.99-103
    • /
    • 2013
  • Objectives: This paper was prepared in memory of Jerry Sherwood, who provided a significant contribution to the Korean environmental and occupational health fields. Methods: Rare air quality data in Seoul were gathered by Jerry Sherwood when he visited Korea in the early 1980s. $SO_2$ and TPM concentrations were measured. These air quality measurements were based on ambient stationary monitoring and indoor air quality monitoring in various locations. Measurement during transportation was also applied. Results: Ambient $SO_2$ and TPM concentrations in Seoul were very high in the early 1980s. Ambient $SO_2$ concentrations were higher at nighttime. While ambient $SO_2$ concentrations varied by location, the Guro industrial area showed high levels. When indoor sources were presented, indoor $SO_2$ concentration was higher than outdoor level. Coal briquettes were closely associated with high indoor $SO_2$ concentration. Conclusion: This paper provided valuable historical information of air quality in Seoul.

몰리브덴 팁 전계 방출 표시 소자의 프릿 실링에 있어서 분위기 기체가 전계 방출 성능에 미치는 영향 (Influence of Ambient Gases on Field Emission Performance in the Frit-sealing Process of Mo-tip Field Emission Display)

  • 주병권;김훈;정재훈;김봉철;정성재;이남양;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권7호
    • /
    • pp.525-529
    • /
    • 1999
  • The influence of ambient gases on field emission performance of Mo-field emitter array(FEA) in the frit-sealing step of field emission display(FED) packaging process was investigated. Mo-tip FEA was mounted on the glass substrate having a surrounded frit(Ferro FX11-137) and fired at $415^{\circ}C$ in the ambient gases of air, $N_2$ and Ar. The Ar gas was proved to be most proper ambient among the used gases through evaluating the turn-on voltage and field emission current of the fired Mo-tip FEA devices. It was confirmed that the Mo surface fired in Ar ambient was less oxidized when compared with another ones annealed in air and Ar ambient by the AFM, XPS, AES and SIMS analysis. Finally, the 3.5 inch-sized Mo-tip FED, which was packaged using frit-sealing process in the Ar ambient, was proposed.

  • PDF

Perturbation of Background Atmospheric Black Carbon/PM1 Ratio during Firecracker Bursting Episode

  • Majumdar, Deepanjan;Gavane, Ashok Gangadhar
    • Asian Journal of Atmospheric Environment
    • /
    • 제11권4호
    • /
    • pp.322-329
    • /
    • 2017
  • Perturbation in ambient particulate matter ($PM_1$, $PM_{2.5}$, $PM_{10}$) and black carbon (BC) concentrations was studied during a firecracker bursting episode in Diwali (Festival of Lights) celebrations in Nagpur, India. Firecracker bursting resulted in greater escalation in fine particulates over coarse particulates while $PM_{2.5}$ was found to be dominated by $PM_1$ concentration. On the Diwali day, daily mean concentration of $PM_{2.5}$ and $PM_{10}$ exceeded Indian National Ambient Air Quality Standards by over 1.8 and 1.5 times, respectively, while daily mean BC concentration on the same day was almost two times higher than the previous day. The BC/$PM_1$ ratio reduced remarkably from about 0.26 recorded before fire-cracker bursting activity to about 0.09 during fire-cracker bursting on Diwali night in spite of simultaneous escalation in ambient BC concentration. Such aberration in BC/$PM_1$ was evidently a result of much higher escalation in $PM_1$ than BC in ambient air during firecracker bursting. The study highlighted strong perturbations in ambient $PM_1$, $PM_{2.5}$, $PM_{10}$ concentrations and BC/$PM_1$ during the firecracker bursting episode. Altered atmospheric BC/$PM_1$ ratios could serve as indicators of firecracker-polluted air and similar BC/$PM_1$ ratios in local and regional air masses might be used as diagnostic ratios for firecracker smoke.