• Title/Summary/Keyword: Ambient Air

Search Result 1,457, Processing Time 0.035 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Experimental Study of Transition to Secondary Acoustic Instability at Downward-Propagating Premixed Flame in a Tube (튜브 내 하향 전파하는 예혼합 화염의 이차 열음향 불안정성 천이에 관한 실험적 연구)

  • Park, Juwon;Kim, Daehae;Park, Dae Geun;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.7
    • /
    • pp.915-921
    • /
    • 2020
  • Thermoacoustic instability caused by air conditioning in a combustion chamber has emerged as a problem that must be solved to establish a stable combustion system. Thermoacoustic instability is largely divided into primary and secondary acoustic instability. In this study, an experimental study of the effects of heat losses was conducted to investigate the mechanism of secondary acoustic instability. To generate the secondary acoustic instability, a quarter-wavelength resonator with one open end and one closed end was used, and the inside of the resonator was filled with premixed gases. Subsequently, secondary acoustic instability with downward-propagating flames could be realized via thermal expansion on the burnt side. To control heat losses qualitatively, an additional co-axial tube was installed in the resonator with air or nitrogen supply. Therefore, additional diffusion flames can be formed at the top of the resonator depending on the injection of the oxidizer into the co-axial tube when rich premixed flames are used. Consequently, secondary acoustic instability could not be achieved by increasing heat losses to the ambient when the additional diffusion flame was not formed, and the opposite result was obtained with the additional diffusion flame.

Evaluation of the Effect of Urban-agriculture on Urban Heat Island Mitigation (도시농업의 도시열섬현상 저감효과에 대한 계량화 평가연구)

  • Eom, Ki-Cheol;Jung, Pil-Kyun;Park, So-Hyun;Yoo, Sung-Yung;Kim, Tae-Wan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.5
    • /
    • pp.848-852
    • /
    • 2012
  • Vegetation can make not only to lower the urban ambient air temperature (UAAT) by crop evapotranspiration (ET) and increasing solar radiation albedo, but also to reduce the urban air pollution by $CO_2$ uptake and $O_2$ emission in addition to the reducing ozone concentrations by aid of lower the UAAT. To evaluate the effect of vegetation on urban heat island mitigation (UHIM), the climate change of 6 cities during 30 years are analysed, and the amount of ET, $CO_2$ uptake, $O_2$ emission and ozone concentrations are estimated in Korea. The most hot season is the last part of July and the first part of August, and the highest average UAAT of a period of ten days was $35.03^{\circ}C$ during 30 years (1979 - 2008). The mean values of maximum ET of rice and soybean in urban area during urban heat island phenomena were 6.86 and $6.00mm\;day^{-1}$, respectively. The effect of rice and soybean cultivation on lowering the UAAT was assessed to be 10.5 and $3.0^{\circ}C$ in Suwon, respectively, whereas the differences between the UAAT and canopy temperature at urban paddy and upland in Ansung were 2.6 and $2.2^{\circ}C$. On the other hand, the urban-garden in Suwon city had resulted in lowering the UAAT and the surface temperature of buildings to 2.0 and $14.5^{\circ}C$, respectively. Furthermore, the amounts of $CO_2$ uptake by rice and soybean were estimated to be 20.27 and $15.54kg\;CO_2\;10a^{-1}day^{-1}$, respectively. The amounts of $O_2$ emission by rice and soybean were also assessed to be 14.74 and $11.30kg\;O_2\;10a^{-1}day^{-1}$, respectively. As other cleaning effect of air pollution, the ozone concentrations could be also estimated to reduce 21.0, 8.8, and 4.0 ppb through rice-, soybean cultivation, and urban gardening during most highest temperature period in summer, respectively.

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.

Dehumidification and Temperature Control for Green Houses using Lithium Bromide Solution and Cooling Coil (리튬브로마이드(LiBr) 용액의 흡습성질과 냉각코일을 이용한 온실 습도 및 온도 제어)

  • Lee, Sang Yeol;Lee, Chung Geon;Euh, Seung Hee;Oh, Kwang Cheol;Oh, Jae Heun;Kim, Dea Hyun
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.337-341
    • /
    • 2014
  • Due to the nature of the ambient air temperature in summer in korea, the growth of crops in greenhouse normally requires cooling and dehumidification. Even though various cooling and dehumidification methods have been presented, there are many obstacles to figure out in practical application such as excessive energy use, cost, and performance. To overcome this problem, the lab scale experiments using lithium bromide(LiBr) solution and cooling coil for dehumidification and cooling in greenhouses were performed. In this study, preliminary experiment of dehumidification and cooling for the greenhouse was done using LiBr solution as the dehumidifying materials, and cooling coil separately and then combined system was tested as well. Hot and humid air was dehumidified from 85% to 70% by passing through a pad soaked with LiBr, and cooled from 308K to 299K through the cooling coil. computational Fluid Dynamics(CFD) analysis and analytical solution were done for the change of air temperature by heat transfer. Simulation results showed that the final air temperature was calculated 299.7K and 299.9K respectively with the deviation of 0.7K comparing the experimental value having good agreement. From this result, LiBr solution with cooling coil system could be applicable in the greenhouse.

Autotrophic Growth of Dendranthema grandiflorum R. 'Bongwhang' Plantlets In Vitro as Affected by PPF, Air Exchange Rate and $\textrm{CO}_2$ Concentration (봉황국화의 자가영양배양시 광도, 환기횟수 및 $\textrm{CO}_2$농도가 기내생육에 미치는 영향)

  • 김영회;정병룡
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.56-66
    • /
    • 1999
  • Growth of Dendranthema grandiflorum R. ‘Bongwhang’plantlets, as affected by three levels of photosynthetic photon flux (PPF), 70, 150 and 220 $\mu$mol. $m^{-2}$ . $s^{-1}$ , three levels of C $O_{2}$ concentration, 400-500 (ambient), 1000 and 2000 $\mu$mol.mo $l^{-1}$ , and two levels of number of air exchanges per hour (NAEH), 0.1 $h^{-1}$ and 2.8 $h^{-l}$, was studied. Explants were obtained from photomixotrophically-micropropagated plantlets. Four explants were planted in each 3.7$\times$10$^{-4}$ $m^{3}$ polycarbonate box containing MS medium supplemented with 1.25 meq. $L^{-1}$ $H_{2}$P $O_{4}$$^{[-10]}$ and no added sugar. Explants were cultured under cool-white fluorescent lamps (16 h. $d^{-1}$ ), at 25$\pm$1$^{\circ}C$ temperature, and 70-80% relative humidity. In treatments of 2.8 $h^{-1}$ NAEH, a 10 mm round hole made on the vessel cap was sealed with a microporous filter For higher C $O_{2}$ concentrations in the culture room, C $O_{2}$ gas was provided from a tank of liquefied C $O_{2}$. Fresh and dry weights, height, length of the longest roots, number of leaves, and leaf area significantly increased with increasing PPF and especially, with increasing C $O_{2}$ concentration. Growth was enhanced with increased number of air exchanges per hour (2.8 $h^{-1}$ ). Overall, treatment of 220$\mu$mol. $m^{-2}$ . $s^{-1}$ PPF combined with 2000$\mu$mol.mo $l^{-1}$ C $O_{2}$ and 2.8 $h^{-1}$ NAEH gave the most vigorous growth of Dendranthema grandiflorum R. ‘Bongwhang’ plantlets in vitro.o.

  • PDF

Physiological responses and subjective sensation of human body wearing Cool Mapsi in air-conditioning environment (냉방환경에서 쿨맵시 착용에 따른 생리적 반응과 주관적 감각)

  • Kang, Noo-Ri;Na, Young-Joo
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.359-370
    • /
    • 2010
  • The purpose of this study is to test the performance of the recommended summer dressing for office man through the analysis of skin temperature changes by air-conditioning temperature. We tested two clothing combinations; formal wear with necktie and casual shirts without necktie as for Cool mapsi. 4 male subjects sat to stabilize for thirty minutes after entering artificial-climate chamber with both temperature of $25^{\circ}C$, $27^{\circ}C$ and $50{\pm}10%$ R.H. And during 60 minute experiments of simulating office work, the subjective feelings including thermal, humidity and comfort sensation, skin temperature, clothing humidity and sweat amount were measured at the equal intervals. The result is that formal wear of $25^{\circ}C$ and Cool mapsi of $27^{\circ}C$ show good values such as low skin temperature, low clothing humidity and neutral thermal sensation. And Cool mapsi of $25^{\circ}C$ shows the risk of low rectal temperature for long and static energy level of office work. Formal wear of $27^{\circ}C$ shows high values of mean skin temperature, clothing humidity and thermal sensation. Second experiment was to find the ambient temperature when the subject wearing formal wear shows the skin temperature corresponding to which he shows on Cool mapsi of $27^{\circ}C$. The air-conditioning temperature on wearing formal wear has to be $2^{\circ}C$ lower to produce the corresponding skin temperature to which shows on wearing Cool mapsi of $27^{\circ}C$. Therefore it is possible to increase room temperature to $27^{\circ}C$, when wear Cool mapsi for summer office, for skin temperature and thermal sensation are produced the same.

  • PDF

Distribution Characteristics of the Concentration of Ambient PM-10 and PM-2.5 in Daegu Area (대구지역 대기 중 PM-10과 PM-2.5의 농도분포 특성)

  • Do, Hwa-Seok;Choi, Su-Jin;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Kim, Eun-Kyung;Song, Hee-Bong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.1
    • /
    • pp.20-28
    • /
    • 2014
  • The three air quality monitoring sites, analysed simultaneously PM-10 and PM-2.5, ie. Ihyeondong in industrial area, Manchondong in residential area, Pyeongnidong in streetside, among 13 air quality monitoring sites in Daegu area, were investigated the concentration distribution characteristics of PM-2.5 and PM-10 in the last 2 years (2011~2012). PM-10 concentrations exceeded annual average reference value ($50{\mu}g/m^3$) in Ihyeondong ($52.5{\mu}g/m^3$) and Pyeongnidong ($60.9{\mu}g/m^3$) but satisfied in Manchondong ($44.9{\mu}g/m^3$). All PM-2.5 concentrations exceeded EPA annual standard value of the United States ($15{\mu}g/m^3$) in three points, but also exceeded new control annual standard value ($25{\mu}g/m^3$) coming into effect in 2015. Seasonal concentration of PM-10 appeared the order of spring > winter > fall > summer, and in the case of PM-2.5, the order was winter > spring > fall > summer. Monthly concentrations of PM-10 and PM-2.5 were highest in February and lowest in September. Diurnal concentrations of PM-10 and PM-2.5 increased from 7:00 AM, and recorded the highest concentration between 10:00 AM and 11:00 AM. And after 6:00 PM it lowered continuously and tended to show fixed concentrations from evening until early morning. In addition, the concentration of fine particles during the week was higher than the weekend. The fluctuation in industrial area was larger than the residential area. At the PM-2.5/PM-10 ratio, summer was generally high, spring was the lowest. And, when yellow sand occurred, it was 0.32 to 0.42. It was very low compared to 0.54 to 0.64 during non-yellow sand times. This paper for the state and the characteristics of Daegu' fine particles (PM-10, PM-2.5) will be valuable to future researches of fine particles and air pollution management.

Mathematical Models of Photosynthetic Rate of Hydroponically Grown Cucumber Plants as Affected by Light Intensity, Air Temperature, Carbon Dioxide and Leaf Nitrogen Content (광도, 온도, $\textrm{CO}_2$ 농도 및 엽중 질소농도의 변화에 따른 양액재배 오이의 광합성속도에 관한 수리적 모형)

  • 임준택;백선영;정현희;현규환;권병선
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.171-178
    • /
    • 2000
  • Gross photosynthetic rats of leaves of hydroponically grown cucumber plants(Cucumis sativus L. cv. Guwoosalichungjang) were measured under various conditions of photosynthetic photon flux(PPF), ambient $CO_2$ concentration, air temperature and leaf nitrogen contents. Light compensation point of leaf photosynthesis appeared to be in the range of 10~20$\mu$mol.m$^{-2}$ .s$^{-1}$ and light saturation point be above 1000$\mu$mol.m$^{-2}$ .s$^{-1}$ . Gross photosynthetic rates increased persistently and asymptotically as air temperature rose from 12$^{\circ}C$ to 32$^{\circ}C$. However, there were only small differences in gross photosynthetic rates in the range of 24-32$^{\circ}C$, so that the range seemed to be optimal for photosynthesis of cucumber plants at the condition of $CO_2$ concentration of 400$\mu$mol.mol$^{-1}$ and PPF of around 400$\mu$mol.m$^{-2}$ .s$^{-1}$ . $CO_2$ compensation point of leaf photosynthesis appeared to be in the range of 20-40$\mu$mol.mol$^{-1}$ and $CO_2$ saturation point be above 1200$\mu$mol.mol$^{-1}$ . Gross photosynthetic rates increased sigmoidally as leaf nitrogen content increased. These environmental factors interacted synergistically to enhance gross photosynthetic rate, so that the rate increased multiplicatively s level of one factor increased progressively with higher levels of he other factors. Mathematical models wer developed to estimate the gross photosynthetic rate in accordance with the variations of these environmental factors. These modes can be used not only to explain he variation of growth or yield of cucumber plants under different environmental conditions but also as building blocks of plant growth model or expert system of cucumber plants.

  • PDF

Characteristics of PM2.5 and PM10 Concentration in Pusan Area (부산지역 PM2.5와 PM10의 농도 특성)

  • Kim, Sang-Youl;Cheong, Jang-Pyo;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1159-1170
    • /
    • 2000
  • It is necessary to improve the ambient air quality through the proper treatment and control of pollutants by designating air pollutants to regulatory ones. Especially, human took a concern for particulate matters which raised visibility reduction, public health effects and injury of property for urban areas. In order to reduce the effect of particulate matters, we need to establish proper control strategies based on the concentration characteristics of particulate matters. In this study. to evaluate the characteristics of $PM_{2.5}$ and $PM_{10}$. thirty-eight samples of $PM_{2.5}$ and $PM_{10}$ were collected at Nam-Gu sampling site where continuous air monitoring system has been operated, from May, 1999 to November, 1999, and their concentrations for the mass and anion components($Cl^-$, $NO_3{^-}$, $SO_4{^{2-}}$) were analyzed. The important conclusions obtained in this study were as followings. Total average mass concentrations of $PM_{2.5}$ and $PM_{10}$ were 35.016 and $50.293{\mu}g/m^3$ respectively. and $PM_{2.5}/PM_{10}$ ratio was calculated 0.692. Total average concentrations of anion components in $PM_{2.5}$ were $1.581(Cl^-)$, $3.690(NO_3{^-})$ and $12.825(SO_4{^{2-}}){\mu}g/m^3$ and those in $PM_{10}$ were $2.471(Cl^-)$, $5.819(NO_3{^-})$ and $14.414(SO_4{^{2-}}){\mu}g/m^3$ respectively. From the correlations analysis. the correlation coefficient between mass concentration of $PM_{2.5}$ and $PM_{10}$ was calculated as 0.945. The correlation coefficients between $PM_{2.5}$ and anion components were analyzed as $Cl^-$(0.025), $NO_3{^-}$(0.788) and $SO_4{^{2-}}$(0.500) respectively, and the correlation coefficients between $PM_{10}$ and anion components were analyzed as $Cl^-$(-0.019), $NO_3{^-}$(0.806) and $SO_4{^{2-}}$)(0.535) respectively.

  • PDF