• 제목/요약/키워드: Alveolar bone loss/surgery

검색결과 108건 처리시간 0.027초

임플란트 주위 각화 조직 폭경의 증대를 위한 유리치은 이식술과 세포외 기질 이식술의 임상적 평가 (Clinical evaluation of the effects of free gingival and extracellular matrix grafts to increase the width of the keratinized tissue around dental implants)

  • 정휘성;강준호;장윤영;윤정호
    • 대한치과의사협회지
    • /
    • 제55권1호
    • /
    • pp.30-41
    • /
    • 2017
  • Inadequate keratinized mucosa around dental implants can lead to more plaque accumulation, tissue inflammation, marginal recession and attachment loss. We evaluated the effects of free gingival and extracellular matrix membrane grafts performed to increase the insufficient width of keratinized tissue around dental implants in the posterior mandible. A 47-year-old female patient presented with discomfort due to swelling of the lower right second premolar area. Due to severe destruction of alveolar bone, the tooth was extracted. After 3 months, a guided bone regeneration (GBR) procedure was performed and then a dental implant was placed 6 months later. During the second-stage implant surgery, free gingival grafting was performed to increase the width of the keratinized tissue. After 12 months, a clinical evaluation was performed. A 64-year-old female patient had a missing tooth area of bilateral lower molar region with narrow zone of keratinized gingiva and horizontal alveolar bone loss. Simultaneous implant placement and GBR were performed. Five months after the first-stage implant surgery, a gingival augmentation procedure was performed with an extracellular matrix membrane graft to improve the width of the keratinized tissue in the second-stage implant surgery. After 12 months, a clinical evaluation was performed. In these two clinical cases, 12 months of follow-up, revealed that the increased width of the keratinized tissue and the deepened oral vestibule was well maintained. A patient showed a good oral hygiene status. In conclusion, increased width of keratinized tissue around dental implants could improve oral hygiene and could have positive effects on the long-term stability and survival rate of dental implants. When planning a keratinized tissue augmentation procedure, clinicians should consider patient-reported outcomes.

  • PDF

7-mm-long dental implants: retrospective clinical outcomes in medically compromised patients

  • Nguyen, Truc Thi Hoang;Eo, Mi Young;Cho, Yun Ju;Myoung, Hoon;Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권5호
    • /
    • pp.260-266
    • /
    • 2019
  • Objectives: Dental implants shorter than 8 mm, called short dental implants (SDIs), have been considered to have a lower success rate than standard length implants. But recent studies have shown that SDIs have a comparable success rate, and implant diameter was more important for implant survival than implant length. Also, SDIs have many advantages, such as no need for sinus lifting or vertical bone grafting, which may limit use in medically compromised patients. Materials and Methods: In this study, 33 patients with 47 implants 7-mm long were examined over the last four years. All patients had special medical history and were categorized into 3 groups: systemic disorders, such as diabetes mellitus (controlled or uncontrolled), mental disability, and uncontrolled hypertension; oral cancer ablation with reconstruction, with or without radiotherapy; diverse osteomyelitis, such as osteoradionecrosis and bisphosphonate-related osteonecrosis of the jaw. Most of these patients have insufficient residual bone quality due to mandible atrophy or sinus pneumatization. Results: The implant diameters were 4.0 (n=38), 4.5 (n=8), and 5.0 mm (n=1). Among the 47 implants placed, 2 implants failed before the last followup. The survival rate of 7-mm SDIs was 95.74% from stage I surgery to the last follow-up. Survival rates did not differ according to implant diameter. The mean marginal bone loss (MBL) at 3 months, 1 and 2 years was significantly higher than at implant installation, and the MBL at 1 year was also significantly higher than at 3 months. MBL at 1 and 2 years did not differ significantly. Conclusion: Within the limitations of the present study, the results indicate that SDIs provide a reliable treatment, especially for medically compromised patients, to avoid sinus lifting or vertical bone grafting. Further, long-term follow-up is needed.

치주질환 원인의 심한 골소실을 동반한 발치와에 대한 치조제 증강술과 연조직 대체제를 이용한 조직 재생 효과: 증례보고 (Regeneration of total tissue using alveolar ridge augmentation with soft tissue substitute on periodontally compromised extraction sites: case report)

  • 오예림;이재관;엄흥식;장범석;이종빈
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.276-284
    • /
    • 2023
  • 발치 후 시간이 지남에 따라 치조골이 흡수되는 것은 자연스러운 현상이다. 치조골 소실과 상부 연조직의 감소는 추후 임플란트 식립 및 임플란트의 장기 생존 가능성에 어려움을 준다. 이번 증례보고는 치주질환에 이환된 발치와에 치조제 증강술과 연조직 대체제 중 이종 콜라겐 기질을 함께 이용하여 임플란트 식립 부위의 연조직과 경조직을 증가시키는 데 중점을 둔다. 각각의 증례에서 치조골의 너비가 6 mm, 8 mm, 4 mm로 증가하였고, 임플란트 주변으로 치간 유두의 재생과 각각 4 mm, 6 mm, 4 mm의 협측 각화치은을 보여준다. 증대된 치조골은 임플란트 수술을 용이하게 하며 치간 유두와 각화치은은 심미적인 보철이 가능하게 한다. 이 연구는 치주질환이 이환된 발치와를 가진 환자에게 치조제 증강술을 시행하고 연조직 대체제를 추가로 사용함으로써 임플란트 식립을 위한 보다 나은 환경을 제공하고 심미적이고 예지성 있는 임플란트 수술을 위한 긍정적인 효과를 보여준다.

Short-term, Multi-center Prospective Clinical Study of Short Implants Measuring Less Than 7mm

  • Kim, Young-Kyun;Yi, Yang-Jin;Kim, Su-Gwan;Cho, Yong-Seok;Yang, Choon-Mo;Liang, Po-Chin;Chen, Yu-Yal;I, Lee-Long;Sim, Christopher;Tan, Winston;Ser, Go Wee;Yue, Deng;Yi, Man;Ping, Gong
    • Journal of Korean Dental Science
    • /
    • 제3권1호
    • /
    • pp.11-16
    • /
    • 2010
  • Objective : This prospective study sought to verify the stability of three types of short implants measuring 7mm or less. Materials and methods : Implants measuring 7mm or less were placed in patients at multicenter dental clinics in Korea, China, Taiwan, and Singapore. Initial stability, intraoperative and postoperative complications, crestal bone loss, and survival rate of the implant were prospectively evaluated. Results : The primary stability of a 6-mm implant was lower than that of a 7-mm implant. The marginal bone loss of short implants measuring less than 7mm was minimal. Complications such as wound dehiscence, implant mobility, and peri-implant mucositis developed, and these were associated with initial implant failure. The short-term survival rate of 6-mm implant was 93.7%, and that of 7-mm implant, 96.6%. Conclusion : Short implant for the mandible with insufficient height for the residual ridge can be selectively used. Poor primary stability and wound dehiscence can cause osseointegration failure and alveolar bone loss.

  • PDF

Does apical root resection in endodontic microsurgery jeopardize the prosthodontic prognosis?

  • Cho, Sin-Yeon;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • 제38권2호
    • /
    • pp.59-64
    • /
    • 2013
  • Apical surgery cuts off the apical root and the crown-to-root ratio becomes unfavorable. Crown-to-root ratio has been applied to periodontally compromised teeth. Apical root resection is a different matter from periodontal bone loss. The purpose of this paper is to review the validity of crown-to-root ratio in the apically resected teeth. Most roots have conical shape and the root surface area of coronal part is wider than apical part of the same length. Therefore loss of alveolar bone support from apical resection is much less than its linear length.The maximum stress from mastication concentrates on the cervical area and the minimum stress was found on the apical 1/3 area. Therefore apical root resection is not so harmful as periodontal bone loss. Osteotomy for apical resection reduces longitudinal width of the buccal bone and increases the risk of endo-perio communication which leads to failure. Endodontic microsurgery is able to realize 0 degree or shallow bevel and precise length of root resection, and minimize the longitudinal width of osteotomy. The crown-to-root ratio is not valid in evaluating the prosthodontic prognosis of the apically resected teeth. Accurate execution of endodontic microsurgery to preserve the buccal bone is essential to avoid endo-perio communication.

임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구 (MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION)

  • 박주진;이영수;백두진;박원희;유동엽
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

심하게 흡수된 치조제에 Titanium 강화 Gore-Tex (TRG) 및 Titanium Mesh로 수직적 골증대술을 실시한 증례보고 (Alveolar Ridge Augmentation Using Titanium Reinforced Goretex (TRG) and Titanium Mesh in Severe Alveolar Bone Loss Area: Case Report)

  • 김원직;윤경성;홍수련;최진경;이용욱;김동석;현종오;조효원;최지혜;정태웅;배윤기;권선규;최현준;이현수;양수남
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권1호
    • /
    • pp.66-72
    • /
    • 2011
  • A severely vertical resorbed ridge is a significant challenge in implant dentistry. To solve this problem, several augmentation techniques, such as guided bone regeneration (GBR), onlay bone grafts, distraction osteogenesis, and ridge splitting techniques, have been proposed and used for several years. Among these methods, vertical ridge augmentation using guided bone regeneration aims to build space and guide osteoblasts to this space to promote osteogenesis. The aim of guided bone regeneration is to maintain and stabilize the space and block the proliferation of adjacent soft tissue. In our hospital, we encountered a case of a woman in her forties with an atrophied mandible, who underwent implant surgery in the right mandible. Titanium reinforced Gore-Tex (TRG) was used to augment the mandible and titanium mesh was used in the left mandible. Favorable results were obtained. This report compares the two methods and reviews the relevant literature.

Comparison of peri-implant marginal bone level changes between tapered and straight implant designs: 5-year follow-up results

  • Park, Han;Moon, Ik-Sang;Chung, Chooryung;Shin, Su-Jung;Huh, Jong-Ki;Yun, Jeong-Ho;Lee, Dong-Won
    • Journal of Periodontal and Implant Science
    • /
    • 제51권6호
    • /
    • pp.422-432
    • /
    • 2021
  • Purpose: The aim of this study was to compare straight and tapered implant designs in terms of marginal bone loss, the modified plaque index (mPI), and the modified bleeding index (mBI) for 5 years after functional loading. Methods: Twelve patients were recruited. Two types of implants were placed adjacent to each other: 1 straight implant and 1 tapered implant. Marginal bone loss, mPI, and mBI were measured every year for 5 years after loading. Results: The straight implants showed 0.2±0.4 mm of marginal bone loss at 5 years after loading, while the tapered implants showed 0.2±0.3 mm of marginal bone loss; this difference was not statistically significant (P=0.833). Our analysis also showed no statistically significant differences in mPI (straight implants: 0.3±0.3 vs. tapered implants: 0.2±0.3; P=0.414) or in mBI (straight implants: 0.3±0.4 vs. tapered implants: 0.2±0.3; P=0.317) at 5 years after prosthesis delivery. Conclusions: Straight and tapered implants showed no significant differences with respect to marginal bone loss, mPI, and mBI for 5 years after loading.

Cone-beam computed tomography characterization of the intraosseous vascular canal in the lateral wall of the maxillary antrum

  • Shetty, Shishir Ram;Al Bayatti, Saad Wahby;Marei, Hesham;Shetty, Raghavendra;Abdelmagyd, Hossam Abdelatty;Luke, Alexander Maniangat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권1호
    • /
    • pp.34-39
    • /
    • 2021
  • Objectives: The purpose of the study was to assess the occurrence, location, and dimensions of the intraosseous vascular canal in the lateral wall of the maxillary antrum using cone-beam computed tomography (CBCT). Materials and Methods: In this retrospective study, we examined 400 CBCT scans from our archive of patients who had earlier reported to a dental teaching hospital in the United Arab Emirates. The prevalence, location, and dimensions of the lateral antral intraosseous canal (LAIC) in the maxillary antrum were evaluated by 2 examiners using standardised methods. A third examiner was consulted in cases of disagreement. Results: The prevalence of LAIC was 62.3% (249 maxillary antra) among the study population. The mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC in the posterior maxillary region was 19.83±3.12 mm. There was a significant difference (P=0.05) between the maxillary molar and premolar regions in mean distance from the most inferior point of the alveolar bone and the inferior border of the LAIC. There was no statistically significant difference in mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC between dentulous and edentulous areas (P=0.1). The G3-intrasinusal type canal less than 1mm in diameter was the most common type of LAIC. Conclusion: This study established the approximate location of the LAIC in a United Arab Emirates cohort, which will assist the oral surgeon in selecting the appropriate site for sinus lift procedures with reduced risk of surgical hemorrhage.