• Title/Summary/Keyword: Alveolar Bone

Search Result 1,304, Processing Time 0.029 seconds

Lung Complications After Allogenic Bone Marrow Transplantaion (동종골수이식 후 폐합병증)

  • JeGal, Yang-Jin;Lee, Je-Hwan;Lee, Kyoo-Hyung;Kim, Woo-Kun;Shim, Tae-Sun;Lim, Chae-Man;Koh, Youn-Suck;Lee, Sang-Do;Kim, Woo-Sung;Kim, Won Dong;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.207-216
    • /
    • 2000
  • Background : The occurrence of lung complications after allogenic bone marrow transplantation(BMT) has been reported as 40-60 percent. The risk factors for lung complications are whole body irradiation, high dose chemotherapy, graft versus host disease, old age and CMV infection. The prevalence of graft versus host disease is less in Korea than in Western countries, but frequency of CMV infection is higher. Therefore, the pattern of lung complications may be different in Korea from those in Western countries. Methods : A retrospective cohort study was performed on one hundred consecutive adult patients who underwent allogenic bone marrow transplantation from December, 1993 to May, 1999 at Asan Medical Center. Lung complications were divided into two groups by the time of development, within 30days (pre-engraftment) and beyond 30 days (post-engraftment), and then subdivided into infectious and non-infectious complication. Infectious complications were defined as having the organism in blood, BAL fluid, pleural fluid or sputum, or compatible clinical findings in patients, which improved with antibiotics or an anti-fungal therapy. Result: 1) Eighty three episodes of lung complications had occurred in 54 patients. 2) Within thirty days after BMT, non-infectious complications were more common than infections, but this pattern was reversed after 30 days. After one year post-BMT, there was no infectious complication except in cases of recurrence of underlying disease or development of chronic GVHD. 3) Among the non-infectious complications, pleural effusion (27 episodes) was most common, followed by pulmonary edema (8 episodes), bronchiolitis obliterans(2 episodes), diffuse alveolar hemorrhage (1 episode) and bronchiloitis obliterans with organizing pneumonia (1 episode). 4) The infectious complications were pneumonia (bacterial: 9 episodes, viral: 4 episodes, fungal : 5 episodes, pneumocystis carinii : 1 episode), pulmonary tuberculosis(3 episodes) and tuberculous pleurisy (3 episodes). 5) Lung complications were more frequent in CMV positive patients and in patients with delayed recovery of neutrophil count. 6) The mortality was higher in the patients with lung complications. Conclusion : Lung complications developed in 54% after allogenic BMT and were associated with higher mortality.

  • PDF

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.

Effects of mechanical stress and interleukin-$1{\beta}$ on collagenase and TIMP-1 expression in human periodontal ligament fibroblasts (기계적 자극과 interleukin-$1{\beta}$가 치주인대 섬유아세포의 collagenase와 TIMP-1의 발현에 미치는 영향)

  • Kim, Myung-Lip;Bae, Chang
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.165-174
    • /
    • 1998
  • The turnover of collagen is controlled by the balance between collagen synthesis and degradation. The production of collagenase (matrix metalloproteinase-1) and its inhibitor, tissue inhibitor of matrix metallopmteinase-1 (TIMP-1) are one of the substances which regulate this balance. The periodontal ligament fibroblast plays an important role in collagen metabolism during orthodontic treatment and is believed to be an origin of the osteoblast in the alveolar bone. The collagenase secreted by the periodontal ligament fibroblast and the osteoblast initiates the bone resorption by removing the osteoid layer in the alveloar bone. The interleukin-$1{\beta}$ is secreted by the macrophage during orthodontic treatment. The present study was undertaken to assess the effect of mechanical stress and interleukin-$1{\beta}$ on the expression of collagenase and TIMP-1 in the periodontal ligament fibroblasts using reverse transcription polymerase chain reaction and immunohistochemical staining. The periodontal ligament fibroblasts were stitched by placing the $Petriperm dish^{\circledR}$ dish on the top of spheroidal convex watch glass ($5\%$ surface increase) and tented with interleukin-$1{\beta}$ (1.0 ng/ml), or treated with both of them. Treatment with mechanical stress and/or interleukin-$1{\beta}$ resulted in increased collagenase mRNA expression. The mechanical stress treated group (1.61, 1.62, 1.37 fold increase), the interleukin-$1{\beta}$, tented group (1.68, 1.60, 3.78 fold increase), the mechanical stress and interleukin-$1{\beta}$ treated group (1.89, 1.72, 5.48 fold increase) induced increases in collagenase mRNA compared with the control group after 2, 4, 8 hours respectively. But TIMP-1 mRNA expressions at experimental groups were decreased after 2, 4 hours and increased after 8 hours. The mechanical stress treated group (0.16, 0.49 fold decrease and 3.77 fold increase), the interleukin-$1{\beta}$ treated group (0.15,0.44 fold decrease and 4.46 fold increase), the mechanical stress and interleukin-$1{\beta}$ tented group (0.15, 0.69 fold decrease and 4.81 fold increase) induced changes in TIMP-1 mRNA compared with the control group after 2, 4, 8 hours, respectively. Immunohistochemical stain showed that increased collagenase and TIMP-1 staining of the mechanical stress tented group, the interleukin-$1{\beta}$ treated group, and the mechanical stress and interleukin-$1{\beta}$ treated group compared with that of the control group after 8 hours. These findings suggest that mechanical stress and interleukin-$1{\beta}$ regulate expression of collagenase and TIMP-1.

  • PDF

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

Replicative Senescence of Periodontal Fibroblasts Induces the Changes in Gene Expression Pattern

  • Yi, Tac-Ghee;Jun, Ji-Hae;Min, Byung-Moo;Kim, Moon-Kyu;Kim, Gwan-Shik;Baek, Jeong-Hwa
    • International Journal of Oral Biology
    • /
    • v.32 no.1
    • /
    • pp.35-43
    • /
    • 2007
  • Tooth loss in elderly is mainly caused by alveolar bone loss via severe periodontitis. Although the severity of periodontitis is known to be affected by age, the aging process or the genetic changes during the aging of periodontal tissue cells are not well characterized. In this study, we investigated the effect of in vitro aging on the change of gene expression pattern in periodontal fibroblasts. Gingival fibroblasts (GF) and periodontal ligament fibroblasts (PDL) were obtained from two young patients and replicative senescence was induced by sequential subcultivation. When more than 90% cells were positively stained with senescence-associated ${\beta},-galactosidase$, those cells were regarded as aged cells. In aged GF and PDL, the level of phosphorylated retinoblastoma (RB) and $p16^{INK4A}$ protein was significantly decreased and increased, respectively. However, the protein level of p53 and p21, well known senescence-inducing genes, did not increase in aged GF and PDL. Although $p27^{Kip1}$ and $p15^{INK4B}$, another cyclin-dependent kinase inhibitors, were reported to be involved in replicative senescence of human cells, they were decreased in aged GF and PDL. Because senescent cells showed flattened and enlarged cell shape and are known to have increased focal adhesion, we examined the protein level of several integrins. Aged GF and PDL showed increased protein level of integrin ${\alpha}2$, ${\alpha}v$, and ${\beta}1$. When the gene expression profiles of actively proliferating young cells and aged cells were compared by cDNA microarray of 3,063 genes and were confirmed by reverse transcription-polymerase chain reaction, 7 genes and 15 genes were significantly and commonly increased and decreased, respectively, in aged GF and PDL. Among them, included are the genes that were known to be involved in the regulation of cell cycle, gene transcription, or integrin signaling. The change of gene expression pattern in GF and PDL was minimally similar to that of oral keratinocyte. These results suggest that $p16^{INK4A}/RB$ might be involved in replicative senescence of periodontal fibroblasts and the change of gene expression profile during aging process is cell type specific.

A study on the effect of the magnitude of the gable bends on the tooth movement pattern during on-masse space closure in the maxillary dentition (상악전치 후방 견인시 견인 loop후방에 부여한 gable bend 양에 따른 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon;Jung, Sang-Hyuk;Kim, Hui-Jung
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.33-45
    • /
    • 2004
  • The purpose of this experimental study was to determine appropriate magnitude of the Gable bends to produce maximum retraction of the anterior teeth. The Calorific Machine was used to illustrate the tooth movement in three dimension. The experimental teeth except the first premolar were embedded in the artificial alveolar bone part. In a series of experiments, the extraction space was closed using arch wires with bull loops into which the gable bends of $10^{\circ},\;20^{\circ},\;30^{\circ}$ degrees were incorporated. The experiments were repeated three times for each degree of the gable bend. Before and after the space closure, radiographs were taken in the sagittal and occlusal directions using occlusal films. Analysis of variance and Scheffe post hoc test were used to determine significant differences among the three groups. The following results were obtained. 1. As magnitudes of the gable bends increased, more bodily anterior tooth movement was seen and the distance of retraction also increased. 2. As magnitudes of the gable bends increase, the amount of posterior tooth protraction decreased while intrusive and buccal movement increased. 3. The arch was coordinated by distal-in rotation of the canine and mesial-in rotation of the second premolar adjacent to the extraction space.

Mandibular implant supported overdentures with two different mini-implant systems: A case report (두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례)

  • Park, Jin-Hong;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.267-272
    • /
    • 2016
  • This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator's metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.

Full-mouth rehabilitation of the patient with severe tooth wear using all ceramic restorations (과도한 마모를 보이는 환자에서 완전도재관을 이용한 구강회복 증례)

  • Kim, Tae Su;Lee, Jae Hyun;Lee, Chul Won;Lee, Won Sup;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.306-313
    • /
    • 2016
  • Tooth wear is known as a normal physiological process which gradually progresses. It is reported that vertical dimension can be kept stable because amount of physiologically worn loss could be compensated by growth of alveolar bone and tooth eruption. However, excessive tooth wear as pathologic wear can cause pathologic pulp, disharmony with occlusal plane, functional disorders and esthetic problems so that full mouth rehabilitation could be needed in these cases. Recovery of function and esthetic improvement should be considered for alteration of the vertical dimension. Determination of the vertical dimension of occlusion is needed to be in harmony with the neuromuscular system. This clinical report describes 36 year-old female patient who had chief complaint of severely worn dentition and esthetic discomfort. An increase of 2.0 mm at maxillary incisal edge was done to restore vertical dimension. It was based on the degree of tooth wear and esthetics.

Esthetic removable partial denture with implants and resin clasp: Case report (임플란트와 레진 클래스프를 이용한 심미 가철성 국소의치 증례)

  • Kim, Su-Min;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.58-65
    • /
    • 2015
  • For the rehabilitation of fully edentulous patients, implant-supported removable partial dentures can be considered as one of the treatment options with complete dentures or implant-supported overdentures. If removable partial dentures are used in combination with a small number of implants placed in strategically important positions, it can offer additional stability, retention and support through implants and reduce a burden of surgical procedures compared with fixed implant-supported prostheses with extensive implant placement. Moreover, the economical benefit can be expected as well. The purpose of this case report is to present a treatment in which an implant-supported removable partial denture was fabricated considering residual alveolar bone status and demands after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area, fixed prostheses were fabricated with implant placement and in posterior area, short implants provide only support for the removable partial denture. In addition, denture base and clasp were made of thermoplastic acrylic resin. Finally, functionally and aesthetically satisfying treatment results can be achieved.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.