• 제목/요약/키워드: Aluminium foil

검색결과 46건 처리시간 0.021초

이온교환수지에 의한 철의 선택적 분리 및 정량 (Selective Separation and Determination of Iron with Ion-Exchange Resins)

  • 정용순;김동원;김성호;이대운
    • 대한화학회지
    • /
    • 제31권1호
    • /
    • pp.45-54
    • /
    • 1987
  • Calcon carboxylic acid[2-hydroxy-1-(2-hydroxy-4-sulfo-1-naphthylazo)-3-naphthoic acid;CCA)]를 이온교환시킨 Dowex 1-X8수지(CCA-Dowex 1-X8)와 2-methyl-8-hydroxyquinoline(MHQ)을 침윤시킨 Amberlite XAD-4 수지(MHQ-XAD-4)를 여러가지 매질중에 있는 철(Ⅲ)이온의 분리-농축에 사용하였다. 이들 수지의 안정성을 검토하고 철(Ⅲ)이온에 대한 흡착능을 측정하였다. 매트릭수의 주성분인 Al(Ⅲ), Ca(Ⅱ), 및 Fe(Ⅲ)들의 수지에 대한 흡착성을 pH를 변화시키며 조사하여 최적 pH범위를 결정하였다. 용리법으로 알루미늄호일과 초정약수중 미량의 철분을 매트릭스 이온으로부터 분리-농축하였다. 농축된 Fe(Ⅲ)는 소량의 강산으로 용리시켜 불꽃 원자흡광광도법으로 정량하였다. 초정약수중의 Fe(Ⅱ)와 Fe(Ⅲ) 이온들은 SP-Sephadex C-25컬럼으로 농축하고, ferrozine용액과 1% ascorbic acid-ferrozine용액으로 단계적 용리법에 의해 용리시킴으로써 각각을 분리할 수 있었다. 분리된 각 이온들은 Fe(Ⅲ)-ferrozine착물의 분석 파장인 562nm에서 분광 광도법으로 정량하였다.

  • PDF

Color stability of thermochromic pigment in maxillofacial silicone

  • Kantola, Rosita;Lassila, Lippo V.J.;Tolvanen, Mimmi;Valittu, Pekka K.
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSE. Maxillofacial silicone elastomer is usually colored intrinsically with color pigments to match skin colors. The purpose of this study was to investigate the color stability of a maxillofacial silicone elastomer, colored with a thermochromic, color changing pigment. MATERIALS AND METHODS. Disc-shaped maxillofacial silicone specimens were prepared and divided into 3 groups: a conventionally colored control group, one group additionally colored with 0.2 wt% thermochromic pigment, and one group with 0.6 wt% thermochromic pigment. Half of the surface of each specimen was covered with an aluminium foil. All of the specimens were exposed to UV radiation in 6 hour cycles over 46 days. In between the UV exposures, half of the specimens were stored in darkness, at room temperature, and the other half was stored in an incubator, at a humidity of 97% and a temperature of $+37^{\circ}C$. Color measurements were made with a spectrophotometer and registered according to the CIELAB $L^*a^*b^*$ color model system. The changes in $L^*$, $a^*$ and $b^*$ values during artificial aging were statistically analyzed by using paired samples t-test and repeated measures ANOVA. P-values <.05 were considered as statistically significant. RESULTS. The UV exposure resulted in visually noticeable and statistically significant color changes in the $L^*$, $a^*$ and $b^*$ values in both of the test groups containing thermochromic pigment. Storage in the incubator lead to statistically significant color changes in the $a^*$ and $b^*$ values of the specimens containing thermochromic pigment, compared to those stored at room temperature. CONCLUSION. The specimens containing thermochromic pigment were very sensitive to UV radiation, and the thermochromic pigment is not suitable, as such, to be used in maxillofacial prostheses.

포장 소재에 따른 전자레인지 가열 조리 패턴 조사 (Investigation on the Heating Patterns Depending on the Packaging Materials During Microwave Cooking)

  • 이화신;조아름;문상권;윤찬석;이근택
    • 한국포장학회지
    • /
    • 제21권1호
    • /
    • pp.27-34
    • /
    • 2015
  • 전자레인지 가열용 제품에서 마이크로파에 의한 불균일한 가열이 일어남에 따라 포장재의 특정 부위에 열 변형이 발생하여 전자레인지 포장 소재에 따른 가열조리 패턴을 조사하였다. 전자레인지 가열용 포장재의 내면으로 이용되는 CPP의 grade에 따른 인장강도, 내열성 및 신장률을 비교하였다. High retortable CPP는 일반 CPP 재질과 비교하여 강한 열 접착강도 및 내열 저항성을 가지고 있었다. 국외 및 국내 CPP 제품의 인장강도 및 신장율은 차이가 있지만 대부분 $160^{\circ}C$ 정도 수준의 내열성을 가지고 있는 것으로 조사되었다. 하지만 소스의 높은 점도와 염분을 함유하는 hot spicy 제품에서는 전자파의 침투가 원활하지 못하여 전자레인지 조리 시 내용물의 균일한 가열이 어려워 국지적 또는 액위선 부위에 포장재의 열 변형이 관찰되었다. G-PET/PET/PET/CPP와 G-PET/PET/NY/CPP로 구성된 포장재를 레토르트 처리했을 때와 레토르트 후 전자레인지 가열 처리하였을 때 상태변화 및 합지강도에 대한 분석결과 합지강도의 차이는 없었으나 레토르트 처리 후 CPP 층의 변형이 관찰되었다. $TiO_2$가 포함된 유백 파우치와 투명 파우치의 열 변형 정도를 비교하였을 때는 $TiO_2$가 포함된 포장재의 열 변형이 더 심하였고, 알루미늄 호일을 부착한 후 전자레인지 가열하였을 때에는 액위선에서 열 변형이 발생되지 않았지만 바닥면에서 열 변형이 관찰되었다. 제품의 내면인 CPP 층의 개질/개선을 통한 내열안정성 확보 및 포장재의 전자파 투과-반사능을 조절하여 포장 내 전자파의 집중을 방지하는 등의 기술 도입 가능성의 검토가 필요할 것으로 판단된다.

  • PDF

Rheogram으로 본 실혈시 신장혈액유통 변화 (Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage)

  • 장세구;신동훈
    • The Korean Journal of Physiology
    • /
    • 제5권1호
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

기계적 노출치수의 Nd:YAG 레이저 조사효과에 대한 연구 (A STUDY ON THE EFFECT OF THE ND:YAG LASER IRRADIATION ON THE MECHANICALLY EXPOSED PULP)

  • 이상호;이창섭;김수관
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.146-158
    • /
    • 2002
  • 이 연구는 기계적으로 노출된 성견의 치수에서 치수내 염증성 변화와 상아질교의 형성과 잔존 생활치수의 섬유모세포의 구조적 변화를 포함하는 치유과정에서의 Nd:YAG laser의 효과를 평가하였다. 실험 1군은 레이저로 3W, 30Hz, 0.2sec 조사조건으로 광섬유를 치수에 직접 접촉시켜 $2{\sim}3$초동안 조사하였다. 실험 2군은 노출된 치수를 레이저로 동일한 조건으로 $2{\sim}3$초 동안 치수에 접촉하여 조사한 후 수산화칼슘 분말을 도포 하였다. 실험 3군은 노출된 치수를 레이저로 $2{\sim}3$초 동안 광섬유를 치수에 접촉시키지 않고 조사한 후 수산화칼슘 분말을 도포 하였다. 표본은 3, 7, 14, 30일에 광학 현미경과 전자 현미경으로 관찰한 바, 다음과 같은 결론을 얻었다. 1. 치수의 염증양상은 대조군, 제 2군과 제 3군이 제 1군에 비해 감소하였으며 제 2군과 제 3군은 염증의 정도가 비슷하나 제 3군에서 치수의 더 깊은 부위까지 염증이 관찰되었다. 2. 제 2군과 제 3군이 대조군에 비해 14일, 30일 표본에서 상아질교의 형성이 전반적으로 균일하게 나타났으며 조상아세포의 배열상태도 더 균일하게 나타났다. 3. 레이저만을 조사한 실험 2군은 시술 3일, 7일째에 치수의 천부에 조직의 괴사 및 빈 공간이 많이 관찰되었으며 세포막의 소실, 세포의 공포화 등 세포의 변형이 관찰됨으로써 다른 군에 비해 조직의 손상이 더 많은 것으로 나타났다. 4. 레이저조사와 수산화칼슘을 도포한 제 2군과 제 3군은 대조군과 제 1군에 비해 섬유아세포의 활성화도가 증가됨으로써 조직의 치유가 상대적으로 빠른 것으로 나타났다.

  • PDF

넙치(Paralichthys olivaceus) Terrine 제품의 제조 및 품질특성 (Processing and Property of Olive Flounder Paralichthys olivaceus Terrine)

  • 윤문주;이재동;박시영;권순재;박진효;강경훈;최종덕;주종찬;김정균
    • 수산해양교육연구
    • /
    • 제27권4호
    • /
    • pp.1084-1091
    • /
    • 2015
  • 5겹 편뜨기한 넙치 육 50 g을 chopper로 마쇄한 후 계란 흰자, 생크림, 레몬즙, 브랜디, 소금 및 후추를 첨가하여 반죽하였다. 랩 위에 평평하게 편 반죽(25 g) 위에 치즈(4 g)를 올리고 다시 반죽(25 g)을 덮은 후 랩으로 돌돌 말고 호일로 감싸서 끓는 물에 5분간 익혀 폴리에틸렌 필름($20{\times}30{\times}0.05mm$)에 진공 포장한 제품을 Terrine-1, 끓는 물에 익히지 않고 바로 진공 포장한 제품을 Terrine-2로 하였다. 동결 상태의 Terrine-1을 전자레인지로 해동하고 데운(2분간) Sample-1과 동결상태의 Terrine-2를 해동한 후 끓는 물에 5분간 익힌 Sample-2의 이화학적 성질과 관능적 특성에 대하여 살펴보았다. Sample-1과 Sample-2 모두 생균수가 검출되지 않았으며, 일반성분의 경우 수분함량은 각각 31.0 및 30.4%, 조단백질은 각각 17.7 및 18.6%, 조지방은 두 시료 모두 8.3%, 조회분은 각각 1.4 및 1.5%로 거의 차이가 없었다. pH는 각각 6.48 및 6.37로 거의 차이가 없었다. 조직감의 경우 Sample-1이 $16.67g/cm^2$, Sample-2가 $23.00g/cm^2$으로 Sample-2가 더 높은 값이었다. Sample-1과 Sample-2의 TBA 값은 큰 차이가 없었다. Sample-1과 Sample-2의 총유리아미노산 함량은 각각 2050.5 및 2065.2 mg/100 g으로 비슷하였으며, 두 시료 모두에서 glutamic acid가 16.6%로 가장 많은 함량이었으며, 다음으로 lysine, leucine 및 aspartic acid 순이었다. 관능검사 결과 Sample-2의 관능적 기호도가 Sample-1보다 조금 높았다.