• 제목/요약/키워드: Aluminium Coagulation

검색결과 45건 처리시간 0.028초

응집(凝集)에 의한 탁도물질(濁度物質) 및 용존(溶存) 유기물질(有機物質)의 동시제거(同時除去)에 대한 연구(硏究) (Co-precipitation of Turbidity and Dissolved Organic Matters by Coagulation)

  • 정상기;전항배;김학성
    • 상하수도학회지
    • /
    • 제9권3호
    • /
    • pp.99-107
    • /
    • 1995
  • Various humic substances are widely distributed in natural water body, such as rivers and lakes and cause the yellowish or brownish color to water. The evidence that humic substances are precursors of THMs formation in chlorinated drinking water has been reported m the Jiteratures. For the reason of public health as well as aesthetics, needs for humic substances removal have been increased in the conventional water treatment processes. In this research, the characteristics of aluminium coagulation of humic acids and humic acids were investigated. The optimum pH and coagulants dosage to remove these materials simultaneously by coagulation were alto studied. The results are as followed; 1. UV-254 absorptiometry for measuring the concentration of aquatic humic acids showed good applicability and stable results. 2. The optimal pH range for humic acids removal by aluminium coagulation was 5 to 5.5, however, an increase in aluminium coagulant dosage could enhance the removal rate of humic acids in the wide pH range. 3. Coprecipitation of humic acids in the typical pH range of 6.5 to 8 in water treatment processes may require the sweep coagulation mechanism with the excess aluminium coagulant dosage. 4. Using PAC(poly aluminium chloride) or PASS(poly aluminium silica sulfate) as coagulants was able to expand the operating range for removing humic acids. 5. From the coagulation of humic substances(UV-254) and turbidity at pH range of 5.5 - 6.0 and alum dose of 86 ppm, the removal efficiency of turbidity from the reservoir water was above 90% and that of UV-254 was above 70%. 6. By using the reservoir water, the optimum condition of rapid mixing for simultaneous removal of turbidity and UV-254 absorbance was pH of 5.8 and LAS dose of 86 ppm, in this study.

  • PDF

Alum과 PACl을 이용한 응집처리 (Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제35권1호
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

마그네슘 및 칼슘 이온이 알루미늄 응집에 의한 인 제거에 미치는 영향 (Effect of Magnesium and Calcium Ions on the Phosphorus Removal by Aluminium Coagulation)

  • 전동걸;이범;이영주;전항배
    • 대한환경공학회지
    • /
    • 제33권4호
    • /
    • pp.231-236
    • /
    • 2011
  • 본 연구는 알루미늄 응집에 의한 인 제거 공정에 마그네슘 및 칼슘과 같은 2가의 금속이온을 첨가하였을 경우 인의 응집특성에 미치는 영향을 조사하였다. 인을 제거하기 위한 최적 알루미늄 응집 pH는 약 5~6 사이이며, 그 이상 pH에서는 TP 제거효율이 감소하였다. 마그네슘이나 칼슘과 같은 2가의 금속이온을 알루미늄 응집공정에 함께 사용할 경우 pH 6 이상 에서도 TP 및 $H_nPO_4^{n-3}$ 제거효율은 안정적으로 95% 이상을 유지하였다. 응집초기 $Al^{3+}/H_nPO_4^{n-3}$ (Al/P) 몰비가 3 이상에서 TP 제거효율이 80% 이상 높게 유지되었으며, 응집 후 잔류 TP 농도를 0.2 mg/L 이하로 제어하기 위해서는 Al/P 몰비는 약 6 이상 이었다. 마그네슘이나 칼슘 이온을 알루미늄 응집공정에 함께 사용할 경우 TP 제거를 위한 최적의 알루미늄 대비 마그네슘 및 칼슘 이온의 몰비($Al^{3+}/Mg^{2+}$ or $Ca^{2+}$)는 모두 2이었다. 알루미늄 응집공정에 마그네슘이나 칼슘 이온을 함께 사용하면, 동일한 양의 TP를 제거하기 위한 알루미늄 응집제 주입량이 감소하였고, 결과적으로 최종 슬러지 발생량도 감소하였다.

Treatment of cutting-oily wastewater by electrocoagulation-flotation (ECF) process: Modeling approach

  • Chawaloesphosiya, Nattawin;Mongkolnauwarat, Jittrapa;Prommajun, Chayanin;Wongwailikhit, Kritchart;Painmanakul, Pisut
    • Environmental Engineering Research
    • /
    • 제20권4호
    • /
    • pp.392-396
    • /
    • 2015
  • This work aims to investigate the oily wastewater treatment by the electrocoagulation-flotation (ECF) and propose a mathematical model for the efficiency prediction. Cutting oil was used to prepare the synthetic oily wastewater with submicron droplet sizes. The chemical coagulation by aluminium sulfate was firstly tested following by the electrocoagulation-flotation with aluminium electrodes. Both processes gave the effective treatment performance with the efficiencies higher than 90%. However, the ECF consumed less aluminium dosage as well as produced less sludge, which were its advantage on the chemical coagulation. The performance of the ECF was found to be affected by the current density, oil concentration, and reaction time according to the analysis by the design of experiment (DOE). Finally, the prediction model was proposed by two approaches, including linear and logarithm function. The latter model gave more accuracy prediction results in terms of treatment efficiency and duration in the lag and stable stages.

해수담수화 전처리 공정으로써 잔류 알루미늄 농도를 고려한 응집-UF 공정 연구 (Evaluation of Coagulation-UF Process Considering Residual Aluminuim Concentration as Seawater Desalination Pretreatment)

  • 손동민;강임석
    • 대한환경공학회지
    • /
    • 제35권7호
    • /
    • pp.495-502
    • /
    • 2013
  • 본 연구는 UF공정의 전처리로써 Al(III)계 응집제인 alum과 PACl을 사용한 응집공정 적용 시 두 응집제의 효율 비교 및 잔류 알루미늄 농도를 고려한 최적 운전 조건을 알아보기 위해 응집제 주입농도, 완속교반의 적용 그리고 해수 원수의 pH를 변화하여 UF막 flux 및 잔류 알루미늄 이온 농도를 조사했다. 그 결과 pH 8.0 조건에서 alum의 주입농도가 증가할수록 flux 또한 증가하였으며 완속교반은 UF막 flux를 오히려 감소시킨 것으로 조사된 반면 PACl의 경우 주입농도가 증가할수록 flux는 일부 감소하는 경향을 보였으며 alum과는 반대로 완속교반 적용시 flux 또한 증가하였다. 반면에 pH 6.5 조건에서 alum 주입량이 0.7 mg/L (as Al)일 때 UF막 flux의 효율이 가장 좋았고 잔류 알루미늄 농도는 0.05 mg/L (as Al) 이하로 측정되었다. PACl의 경우 UF막 flux 측면에서는 최적 조건은 pH 8.0, 주입농도 1.2 mg/L (as Al) 그리고 완속교반 시간을 적용하였을 때였으며 잔류 알루미늄 농도를 고려한 최적 주입조건은 pH 6.5 조건에서 주입농도를 1.2 mg/L (as Al)일 때로 조사되었다.

공업용 포리황산알미늄의 제조에 관한 연구 (A Study on Preparation of Industrial Polyaluminium Sulfate)

  • 육창규;이내우
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.203-210
    • /
    • 1996
  • To improve coagulation characteristics and to reduce dossage of chemicals in watertreatment, polyaluminium sulfate was manufactured by reaction of polymerization between aluminium sulfate and sodium aluminate. As the results of affirmation and performance test, the yield of product was about 24% from molecular cut on levels by ultrafilteration method. The type of molecular is nearly affirmated as a kind of complex like AIm(OH)n(3m-n)+ from Scanning Electron Microscopy (S.E.M.) and X-ray diffraction test. Since the synthesized polymer was supposed to be quasi, further study for stabilization was required.

  • PDF

PAC를 이용한 인제거 공정에서 음이온계 고분자 첨가가 입도 분포에 미치는 영향 (Effect of Anionic Polymer on Particle Size Distribution in PAC Coagulation Process for Phosphorus Removal)

  • 김성홍;이동우;김동한;김두일
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.170-175
    • /
    • 2013
  • Achieving very low phosphorus levels in treated wastewater will require the installation of additional treatment. Phosphorus removal experiments by chemical coagulation were carried out for the effluent of wastewater treatment plant in this study. TP (total phosphorus) or phosphate were highly related to the addition of PAC (poly aluminium chloride) which is one of the inorganic coagulants. But, organic polymer did not significantly affect the phosphorus removal efficiency. Polymer affected the flocculation of particle especially particle matter less than 10 micrometer so, the number of micro particles was decreased by polymer dose. Chlorination would not affect on chemical coagulation process and TP and turbidity could be effectively removed by the co-addition of PAC and polymer.

지르코늄 실리케이트를 응집보조제로 이용한 응집공정에 관한 연구 (A Study on Coagulation Process using Zirconium Silicate as a Coagulation-aid)

  • 조재성;윤태일;전유재;조경철
    • 대한환경공학회지
    • /
    • 제31권3호
    • /
    • pp.203-207
    • /
    • 2009
  • 최근 산업화에 따른 다양한 신종 미량유해물질의 등장과 지속적인 오염물질의 증가로 수질오염의 심각성과 그 위해성에 대한 관심이 커지고 있다. 특히 응집공정을 통하여 유기오염물질 제거를 좀 더 효율적으로 증가시킬 수 있는 방법들이 모색되고 있다. 본 연구는 도시하수 및 호소수를 대상으로 실험하였다. 응집공정에 사용하기 위해 응집 보조제로서 사용될 수 있는 지르코늄 실리케이트($ZrSiO_4$)의 특성을 연구 하였다. 응집공정에서의 지르코늄 실리케이트의 주입방법에 따른 유기물 제거율을 PDA (Photometric Dispersion Analyzer)를 통하여 평가하였다. 지르코늄 실리케이트는 pH 7에서 zeta-potential이 -32.22 mv였고 산성에 가까울수록 낮은 음(-)전하 값을 보였으며 지르코늄 실리케이트를 주입하지 않은 도시하수보다 주입하였을 때 $UV_{254}$ 값이 더 높은 특성을 나타내었다. 또한 PDA실험을 통하여 확인한 결과 지르코늄 실리케이트의 주입은 floc의 성장을 도와주는 것을 확인할 수 있었다. Alum을 이용한 응집공정에 대한 지르코늄 실리케이트의 주입방법을 선 주입, 동시 주입, 후 주입의 3가지 방법으로 실험을 수행하였다. 실험 결과 Alum과 지르코늄 실리케이트를 함께 주입한 경우 Alum을 단독으로 주입한 경우보다 유기물 제거율이 15% 이상 증가하였다. 특히 Alum 20 mg/L과 지르코늄 실리케이트 10 mg/L를 함께 사용한 경우 90% 이상의 높은 유기물제거율을 보였다. PAC (Poly Aluminium Chloride)와 PACS (Poly Aluminium Chloride Silicate)를 응집제로 이용하는 경우에도 지르코늄 실리케이트를 함께 주입 시 $COD_{Cr}$의 제거효율이 15% 이상 향상되었다. 결과적으로 지르코늄 실리케이트를 응집제와 동시에 주입한 방법이 전, 후로 주입한 경우보다 $COD_{Cr}$ 제거효율이 5~10% 높게 나타났으나, 용존성 물질은 시주입 시, 더 낮은 제거효율을 보였다.

정수처리 공정에서 Cryptosporidium Tracer의 제거효율 (Removal Efficiency of Cryptosporidium Tracer in Drinking Water Treatment Process)

  • 이순화;김윤희
    • 대한환경공학회지
    • /
    • 제28권12호
    • /
    • pp.1304-1309
    • /
    • 2006
  • 정수처리 과정에서 Cryptosporidium과 유사한 특성을 가지고 있는 C. tracer를 이용하여 공정별 제거효율을 조사하였다. PACI(Poly aluminium chloride, $Al_2O_3$(10%)) 주입량이 10 mg/L일 때 C. tracer는 97.16%로 가장 높은 제거율을 보였으며, 탁도 제거율과 SS 제거율이 높을수록 C. tracer 응집 효율이 높았다. 원수의 pH가 높을수록 C. tracer 제거율이 증가 하였으며 응집 침전 후의 유출수 탁도와 C. tracer 제거율과의 상관성이 $R^2=0.9506$로 높게 나타나 응집 침전 후의 유출수 탁도로 Cryptosporidium 제거 효율을 평가할 수 있음을 알 수 있었다. 또한 여과 실험에서는 유입 탁도에 따른 C. tracer 제거율은 $94.00{\sim}95.83%$ 범위였으며 유출수 탁도와 C. tracer 제거율과의 상관성은 $R^2=0.8704$였다. 최적 응집 조건 하에서 여과수 탁도가 양호할 경우, 예상되는 Cryptosporidium의 제거율은 응집 침전의 경우 1.55 log(97.16%), 급속모래여과의 경우 1.38 log(95.83%), 응집 침전+급속모래여과의 경우 2.31 log(99.51%)로 나타났다.

화학 응집제 투입에 따른 수질항목별 하수처리 반응곡선 (Saturation curves for chemical coagulation of wastewater treatment)

  • 류재나;오재일;이경종
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.537-548
    • /
    • 2010
  • Recently the Government has announced updated water quality standards for wastewater treatment effluent (become effective in 2012). That includes highly enforced regulations for T-P, BOD and COD, and a large budget, in particular for phosphorus removal, was set by the Ministry of environment. Chemical coagulation destabilizes colloidal particles so that particles grow to larger flocs, and solid particles are removed by solid-liquid separation. The efficiency of chemical coagulation depends on a various factors, including coagulant types and costs, construction and operation costs for the treatment facilities and so on. The proper selection should be based on the treatment efficiency of coagulants and underlying costs. The current research was to evaluate the treatment efficiencies of coagulants on a variety of wastewater influents and to develop saturation curves for several water quality parameters. Typical $Al_2(SO_4)_3$ and $FeCl_3$ were tested under a range of coagulant concentrations. The pollutant removal efficiencies of chemical treatment both for the $Al_2(SO_4)_3$ and $FeCl_3$ were especially high for T-P, followed by SS, BOD and COD. Correlation test also proved the highest relationship between SS and T-P.