• Title/Summary/Keyword: Alternative test method

Search Result 718, Processing Time 0.036 seconds

Temporal Variation of Indoor Air Quality in Daycare Centers (어린이집에서 이산화탄소와 미세먼지의 장기간 시간적인 변이를 활용한 실내환경수준 평가)

  • Kim, Yoonjee;Lee, Sewon;Ban, Hyunkyung;Cha, Sangmin;Kim, Geunbae;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • Objectives: The purposes of the study were to analyze the temporal variation of carbon dioxide ($CO_2$) and particulate matter (PM) in daycare centers and evaluate the appropriateness of the official test method of one-time measurement. Methods: Indoor air quality in 46 daycare centers in the Seoul Metropolitan Area was measured as specified in the official test method of Indoor Air Quality Management law. In addition, indoor air quality in the 46 daycare centers was measured over 37 days using a real-time monitor (AirGuard K). Results: The daily means of $CO_2$ and PM in the 46 daycare centers were $1042.74{\pm}134.45ppm$ and $67.60{\pm}18.25{\mu}g/m^3$, respectively. Indoor air quality in the daycare centers showed significant temporal fluctuation. Measurements for single days were significantly different from the 37-day average exposure. Relative error of short term exposure decreased with an increase in the number of sampling days. The noncompliance rate for $CO_2$ using the official testing method was 2.17%, and none exceeded the $PM_{10}$ standard of $100{\mu}g/m^3$. With monitoring over 37 days, the daily noncompliance rate for $CO_2$ was 50.4% and the daily noncompliance rate for PM was 13.8%. Conclusions: When the official test method evaluates the indoor air at daycare centers one day per year, the results may not represent actual indoor air quality over a longer period of time. Real-time monitoring devices could be an alternative for managing indoor air quality.

Suggestions for Improvement of Performance Assessment according to Achievement Evaluation (성취평가 시행에 따른 수행평가 내실화 방안)

  • Won, Hyo-Heon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.1
    • /
    • pp.203-213
    • /
    • 2014
  • The purpose of this study was to search for the ideal role and performance assessment(PA) in the current school system of Korea, and then to propose some suggestions to improve PA, based on the previous research. The result of the study is presented below. The direction of PA application in school was made to follow the theoretical meaning of PA, to solve the problems related ti its adoption in school, and to help teachers educate students more effectively. The main goal of PA application in term of 'school education' is to help students learn more effectively. That is, the assessment is not only for the evaluation, but also for improving students' learning. PA can be used to assess students' strength and weakness in terms of their academic achievement of various fields of the subject. Also, PA can be used to assess students' academic achievement as an alternative method to the multiple-choice test. Finaly, the results of this study propose some suggestions about how to conduct PA in school to the stakeholders such as educational authorities, schools, teachers, students and parents.

Optimization of the Lowry Method of Protein Precipitation from the H. influenzae Type b Conjugate Vaccine Using Deoxycholic Acid and Hydrochloric Acid

  • Kim, Hyun-Sung;Kim, Sang-Joon;Kim, Hui-Jung;Kim, Han-Uk;Ahn, Sang-Joem;Hur, Byung-Ki
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.3
    • /
    • pp.215-222
    • /
    • 2006
  • The Lowry method was used in this study to measure protein in Haemophilus influenzae type b (Hib) conjugate vaccines (polyribosylibitol phosphate-tetanus toxoid; PRP-TT) using deoxycholic acid (DOC) to induce protein precipitation. Trichloroacetic acid (TCA) did not induce precipitation adequately from the Hib conjugate bulk and the freeze-dried Hib conjugate product. Its yield was approximately 50%. The matrix structure of Hib conjugate inhibits precipitation by TCA. Although the Lowry method can be carried out without precipitation in Hib conjugate bulk when no residual impurities (adipic acid dihydrazide [ADH], 1-ethyl-3-(3-dimethylamino-propyl) carbodiimide-HCI [EDAC], phenol and cyanogens bromide [CNBr], etc.) are present, it cannot be used for Hib conjugate products that contain sucrose 8.5%, because 8.5% concentration of sucrose enhanced the protein concentration. DOC- and HCl-induced precipitation is an alternative method for evaluating the protein content of the Hib conjugate bulk and the Hib conjugate product. The precipitation was optimal with a final concentrate of 0.1% for DOC at $4^{\circ}C$ and pH 2. This Lowry method, using DOC/HCI precipitation to induce protein precipitation, was confirmed a consistent, reproducible, and valid test for proteins in Hib conjugate bulk and its freeze-dried product.

Assessment of lightweight recycled crumb rubber-cement composite produced by preplaced method

  • Shah, Syed Nasir;Mo, Kim Hung;Yap, Soon Poh;Putra, Azma;Othman, Muhammad Nur
    • Advances in concrete construction
    • /
    • v.11 no.5
    • /
    • pp.409-417
    • /
    • 2021
  • The incorporation of non-biodegradable tyre waste in cement-based material has gained more interest towards sustainable construction these days. Crumb rubber (CR) from waste tyre is an alternative for sand replacement in low strength applications. Many researchers have studied CR cement-based materials produced by normal mixing (NM) method and reported a significant decrease in compressive strength due to CR. To compensate this strength loss, this research aims to study the innovative incorporation of CR in cement composite via the preplaced mixing (PM) method. In this investigation, cement composite was produced with NM and PM methods by replacing sand with 0%, 50%, and 100% CR by volume. The test results showed no significant difference in terms of densities of cement composite prepared with both mixing methods. However, cement composite prepared with PM method had lower strength reduction (about 10%) and lowered drying shrinkage (about 20%). In addition, the sound absorption coefficient and noise reduction coefficient of CR cement composite prepared by PM method were in similar range as those prepared with NM method. Overall, the results demonstrate that the PM method is promising, and the maximum replacement level of 50% is recommended for CR in the cement composite.

The Characteristics of Field & Mode Distributions in a Cylindrical Reverberation Chamber (원통형 구조 전자파 잔향실 내 모드 및 필드 분포 특성)

  • 김정훈;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.431-436
    • /
    • 2003
  • In this paper, simulation results of an electromagnetic field and mode distributions in a cylindrical reverberation chamber were presented. Reverberation chamber is an alternative test facility for a semi anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity tests. The method of computing the number of modes in a cylindrical reverberation chamber was presented and the number of modes in a cylindrical reverberation chamber with the same volume was compared with the different ratio of radius to height. The FDTD method was used to produce field characteristics inside of rectangular, right-angled isosceles triangular, and cylinder type reverberation chambers with the same test volume.

A Study on Bearing Capacity Characteristics of Group Crushed-Stone Compaction Piles (군쇄석다짐말뚝의 지지력 특성에 관한 연구)

  • Hwang, Geun-Bae;Lee, Min-Hee;Shin, Hyeon-Cheol;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.705-712
    • /
    • 2005
  • Among soft ground treatment methods with granular soil used in domestic, the sand compaction pile method has been utilized greatly, but, as a result of exhaustion of sand and increase of unit cost, a necessity of an alternative method is suggested. In this study, the static load tests for group crushed-stone compaction piles which were constructed at in-situ site were performed. Pile diameter was 700mm and area of loading plates were changed. The static load tests of single and group piles were performed for area replacement ratio of 20, 30 and 40%. Based on test results, bearing capacity of group crushed-stone compaction pile were estimated. The more both single pile and group pile increase, the more yield bearing capacity tended to increase. Also, the yield bearing capacity of a group pile is about 50% less than the yield bearing capacity of a single pile. If the ground reinforced with the crushed-stone compaction pile is replacement ratio of $20{\sim}40%$, RIYB of both single pile and group pile increases qualitative tendency of linear more than original ground

  • PDF

Partial Discharge Measurement in Power Cables using Switching Impulse Voltages (전력케이블에서 개폐충격파를 이용한 부분방전 측정)

  • Lee, J.S.;Jang, E.;Koo, J.Y.;Kim, J.T.;Cho, Y.O.;Kim, S.J.;Song, L.K.;Kim, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.382-384
    • /
    • 1997
  • On-site partial discharge test by use of AC voltage has been considered not to be appropriate for the extruded power cable due to their large capacitance depending on their lengths. Therefore, it is proposed, in this work, to use switching impulse voltage of which the front time is set from 1ms to 10ms. This newly proposed method enables us to simulate the 1/4 period of power frequency at 60 Hz and to obtain similar effect of AC voltage test. Our tentative results show that 51 voltage is proved to be an alternative method, replacing AC voltage, by which partial discharge was well produced from the artificial defects integrated in 22.9kV distribution power cables.

  • PDF

Comparison of Learning Effects using High-fidelity and Multi-mode Simulation: An Application of Emergency Care for a Patient with Cardiac Arrest (High-fidelity와 Multi-mode 시뮬레이션을 이용한 학습 효과 비교 : 심정지 환자 응급간호 적용)

  • Ryoo, Eon-Na;Ha, Eun-Ho;Cho, Jin-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.43 no.2
    • /
    • pp.185-193
    • /
    • 2013
  • Purpose: Simulation-based learning has become a powerful method to improve the quality of care and help students meet the challenges of increasingly complex clinical practice settings. The purpose of this study was to identify the learning effects using high-fidelity SimMan and multi-mode simulation. Methods: Participants in this study were 38 students who were enrolled in an intensive course for a major in nursing at R college. Collected data were analyzed using Chi-square, t-test, and independent t-test with the SPSS 18.0 for Windows Program. Results: There were no statistically significant differences in learning effects between high-fidelity SimMan and multi-mode simulation group. However, skills in clinical performance in the high-fidelity SimMan group were higher than in the multi-mode group (p=.014), communication in clinical performance in multi-mode simulation group was higher than in the high-fidelity SimMan group (p<.001). Conclusion: Multi-mode simulation with a standardized patient is an effective learning method in many ways compared to a high-fidelity simulator. These results suggest that multi-mode simulation be offered to students in nursing colleges which cannot afford to purchase a high-fidelity simulator, or offered as an alternative.

Development of Alternative Algorithms to the Decoupled Load Flow (Decoupled Load Flow 알고리즘에 대한 유용한 대안 알고리즘들의 개발)

  • Lee, Seung-Chul;Park, Sang-Soo;Park, Kyung-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1514-1519
    • /
    • 1999
  • This paper presents two flexible alternatives to the decoupled load flow(DCL) method. The proposed load flow methods can improve the convergence profiles of the DCL by reflecting in part the effects of the off-diagonal terms in the Jacobian at minimal costs. They can improve the convergence characteristics especially when the power system operating states deviate from the conditions required for stable convergence of the DCL and the P-Q coupling becomes significant. Two algorithms are obtained from the expression of the full Newton-Raphson load flow (NRL) method by successively diminishing the effects of the off-diagonal submatrices in the Jacobian. In the process of simplification, the Neuman series expansion is utilized. Test results show promising performances of the proposed algorithms in their convergence characteristics both in number of iterations and overall convergence speeds. Proposed algorithms are expected to provide flexible alternatives to the NRL when the DCL experiences convergence problems.

  • PDF

An Analytic Network Process(ANP) Study on the Evaluation of Software Development Methods for Maintainability (유지보수성 목표하의 소프트웨어 개발방법 평가에 관한 실증연구 : ANP 기법을 중심으로)

  • Yoon, Min-Suk;Lee, Young;Sung, Sam-Kyung
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.4
    • /
    • pp.141-156
    • /
    • 1999
  • Recently expanded and enhanced software system inevitably demands serious managerial considerations on its maintenance cost. This study proposes a systematic and thorough assessment model for software development methods to the end of maintainability, incorporation ISO 9126 quality standards-based criteria. The Analytic Network Process (ANP) is employed in our model to find the effect of any dependency among the items of the criteria and the alternative methods. This study then applies the model empirically in order to evaluate the efficacies of the Structured Method and the Objected-Oriented Method. At first, this study performs the test on the existence and direction of any dependency under the three types of assumptions, and then determines the relative dominance of the two methods.

  • PDF