• Title/Summary/Keyword: Alternative bracket

Search Result 11, Processing Time 0.026 seconds

Eigenfunctions for Liouville Operators, Classical Collision Operators, and Collision Bracket Integrals in Kinetic Theory Made Amenable to Computer Simulations

  • Eu, Byung-Chan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.779-789
    • /
    • 2012
  • In the kinetic theory of dense fluids the many-particle collision bracket integral is given in terms of a classical collision operator defined in the phase space. To find an algorithm to compute the collision bracket integrals, we revisit the eigenvalue problem of the Liouville operator and re-examine the method previously reported [Chem. Phys. 1977, 20, 93]. Then we apply the notion and concept of the eigenfunctions of the Liouville operator and knowledge acquired in the study of the eigenfunctions to cast collision bracket integrals into more convenient and suitable forms for numerical simulations. One of the alternative forms is given in the form of time correlation function. This form, on a further manipulation, assumes a form reminiscent of the Chapman- Enskog collision bracket integrals, but for dense gases and liquids as well as solids. In the dilute gas limit it would give rise precisely to the Chapman-Enskog collision bracket integrals for two-particle collision. The alternative forms obtained are more readily amenable to numerical simulation methods than the collision bracket integrals expressed in terms of a classical collision operator, which requires solution of classical Lippmann-Schwinger integral equations. This way, the aforementioned kinetic theory of dense fluids is made fully accessible by numerical computation/simulation methods, and the transport coefficients thereof are made computationally as accessible as those in the linear response theory.

On the Design of the Brackets without Flange in Ships' Structure (플랜지가 없는 선체 브라켓의 설계에 관한 연구)

  • Lee, Joo-Sung;Lee, Dong-Bu;Han, Doo-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.2 s.146
    • /
    • pp.197-205
    • /
    • 2006
  • In general, brackets found at tank boundary are design according to the Classification Society Rule. Since much man power is needed in manufacturing the brackets stiffened by flange, it is necessary to suggest alternative designs, of which flanges are removed, through the rigorous structural analysis. In this paper non-linear structural analysis for brackets with and/or without flange have been carried out to examine their structural behavior and ultimate strengths. Alternative designs for brackets are suggested based on the results of ultimate strength analysis so that the alternative brackets have the similar level of strength and stiffness to the original brackets. It has been seen that the structural safety of alternative brackets proposed in this paper are beyond the appropriate level. The primary benefit of replacing the original brackets by the alternatives is the reduction of man power in manufacturing brackets and 10 to 15% weight saving can be expected in additional. This paper ends with some comments about the extension of the present study.

Treatment of Class I crowding using simple tubes bonded with customized resin coverings: A case report

  • Jeong, Seo-Rin;Kim, Hye-In;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.116-123
    • /
    • 2019
  • As an alternative to the conventional fixed appliance that uses orthodontic brackets, a simple round tube without a bonding base can be bonded to the tooth surface by covering the tube with flowable resin. In this technique, bent wires cannot be inserted into the simple tubes; therefore, repositioning of the simple tubes is often required for adjustments. To reduce repositioning of simple tubes, a dome-shaped resin covering of the simple tube can be designed with a customized in-and-out compensation, using three-dimensional computer-aided design software based on digital simulation of orthodontic tooth movement. In the present case, the use of simple tubes bonded with customized resin coverings in a Class I nonextraction case is described in a 17-year-old male, in whom moderate crowding of the anterior teeth was treated over an 8-month period. This case shows that simple tubes can be used as an alternative to brackets in some Class I nonextraction cases, with the potential benefit of reducing decalcification.

Development of a Inspection System for Automotive Part (자동차 부품 누락 방지를 위한 자동 선별 시스템)

  • Shin, Seok-Woo;Lee, Jong-Hun;Park, Sang-Heup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.756-760
    • /
    • 2017
  • Meeting the growing demand deadlines, reducing the production cost and upgrading the quality control measurements are the reasons why the automotive part manufacturers are venturing into automation. Attaining these objectives is impossible with human inspection for many reasons. Accordingly, the introduction of inspection system purposely for door hinge bracket inspection is presented in this study as an alternative for human inspection. This proposal is designed to meet the demands, features and specifications of door hinge bracket manufacturing companies in striving for increased throughput of better quality. To improve demerits of this manual operation, inspection system is introduced. As the inspection algorithm, template matching algorithm is applied to distinguish the articles of good quality and the poorly made articles. Through the verification test of the inspection process algorithm and the similarity metric matching algorithm, the detection accuracy was 98%, and it was applied to the production site to contribute to the improvement of the productivity due to the decrease of the defective product.

Evaluation of friction of ceramic brackets in various bracket-wire combinations (브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정)

  • Cha, Jung-Yul;Kim, Kyung-Suk;Kim, Dong-Choon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.125-135
    • /
    • 2006
  • The purpose of this study was to measure and compare the level of frictional resistance generated from three currently used ceramic brackets; 1, Crystaline $V^{(R)}$, Tomy International Inc., Tokyo, Japan; 2, $Clarity^{(R)}$, 3M Unitek, Monrovia, CA, USA; 3, $Inspire^{(R)}$, Ormco, Orange, CA, USA; with composite resin brackets, Spirit, Ormco, Orange, CA, USA; and conventional stainless steel brackets, Kosaka, Tomy International Inc., Tokyo, Japan used as controls. In this experiment, the resistance to sliding was studied as a function of four angulations $(0^{\circ},\;5^{\circ},\;10^{\circ}\;and\;15^{\circ})$ using 2 different orthodontic wire alloys: stainless steel (stainless steel, SDS Ormco, Orange, CA, USA), and beta-titanium (TMA, SDS Ormco, Orange, CA, USA). After mounting the 22 mil brackets to the fixture and $.019{\times}.025$ wires ligated with elastic ligatures, the arch wires were slid through the brackets at 5mm/min in the dry state at $34^{\circ}C$. Silica-insert ceramic brackets generated a significantly lower frictional force than did other ceramic brackets, similar to that of stainless steel brackets. Beta-titanium archwires had higher frictional resistance than did stainless steel, and all the brackets showed higher static and kinetic frictional force as the angulation increased. When the angulation exceeded $5^{\circ}$, the active configuration emerged and frictional force quickly increased by 2.5 to 4.5-fold. The order of frictional force of the different wire-bracket couples transposed as the angle increased. The silica-insert ceramic bracket is a valuable alternative to conventional stainless steel brackets for patients with esthetic demands.

Cutting Force Measuring System Using the Load Cell for a Milling Process (로드셀을 이용한 밀링 가공시의 절삭력 측정시스템)

  • Kang, E. G.;Park, S. J.;Lee, S. J.;Kwon, H. D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.6
    • /
    • pp.133-140
    • /
    • 2001
  • This paper suggests another system for a cutting force measuring tool in a milling process. Generally, tool dynamometer is taken into account for the most appropriate cutting force measuring tool in the analysis of cutting mechanism. However, high price and limited space make it difficult to be in-situ system for controllable milling process. Although an alternative method using AC current of servo-motor has been suggested, it is unsuitable for cutting force control because of small upper frequency limit and noise. The cutting force measuring system is composed of two load cells placed between the moving table bracket and the nut flange part of ballscrew. It has many advantages such as low cost and wide range measurement than tool dynamometer because of the built-in moving table and the low cost load cell. The static and dynamic model of the measuring system using imbeded load cell is introduced. Various Experiments are carried out to validate both models. By comparing the cutting forces from a series of end milling experiments on the tool dynamometer and the system developed in this paper, the accuracy of the cutting force measuring system is verified. Upper frequency limit is measured by the experiment of dynamic characteristics.

  • PDF

WHIP SPRING FOR THE TREATMENT OF LOCALIZED TOOTH MALPOSITION IN MIXED DENTITION (혼합치열기의 국소적 치열부정을 위한 Whip Spring)

  • Kim, Min-Hee;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.758-762
    • /
    • 1997
  • There are various types of localized tooth malpositions in the mixed dentition, such as abnormal tooth axis, anterior crossbite of some incisors, impaction, midline diastema, ectopic eruption, and so forth. We, Pediatric Dentists, have usually used removable appliances for these instances. But, removable orthodontic appliances, as is known, have marked limitations in some situations, for example, severe rotation, intrusion and extrusion, root torque, closure of large diastema, traction of impacted tooth, etc. In such cases, Whip spring, combined with fixed or removable appliance, can increase utilities of removable orthodontic appliances. The authors have applied whip springs to some cases showing localized positional and arrangement problems, and have witnessed the results as follows; 1. The refined and elaborate control of direction and magnitude of force by the operator, and accurate compliance of the patients were requisite for the treatment with it. 2. It showed special effectiveness for de rotation of incisors. Although it yields some benefit for root movement, the special consideration for incomplete roots in this age bracket was required. 3. In the localized malalignment cases in mixed dentition, uncurable with traditional removable appliances but practically unrealistic with fixed appliance therapy, the whip spring was thought to be a good alternative.

  • PDF

The effect of using laser for ceramic bracket bonding of porcelain surfaces (세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과)

  • An, Kyung-Mi;Sohn, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.275-282
    • /
    • 2008
  • Objective: The purpose of this study was to investigate the effect of using laser for ceramic bracket bonding of porcelain surfaces and to compare it with conventional treatment of porcelain surfaces. Methods: Ninety feldspathic porcelain specimens were divided into 9 groups of 10, with each group having different surface treatments performed. Surface treatment groups were orthophosphoric acid, orthophosphoric acid with silane, hydrofluoric acid, hydrofluoric acid with silane, sandblasted, sandblasted with silane, laser etched, laser etched with silane, and glazed surface served as a control group. In the laser etched groups, the specimens were irradiated with 2-watt superpulse carbon dioxide ($CO_2$) laser for 20 seconds. Ceramic brackets were bonded with light-cure composite resin and all specimens were stored in water at $37^{\circ}C$ for 24 hours. Shear bond strength was determined in megapascals (MPa) by shear test at 1 mm/minute crosshead speed and the failure pattern was assessed. For statistical analysis, one-way ANOVA and tukey test were used. Results: Statistical analysis showed significant differences between the groups. The HFA + S group showed the highest mean shear bond strength ($13.92{\pm}1.94\;MPa$). This was followed by SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA ($10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), G ($2.46\;{\pm}\;1.36\;MPa$), Bond failure patterns of HFA and silane groups, except L + S, were cohesive modes in porcelain while adhesive failure was observed in the control group and the rest of the groups. Conclusions : A 2-watt superpulse $CO_2$ laser etching of porcelain surfaces can provide a satisfactory result for porcelain surface treatment for ceramic bracket bonding. Laser irradiation may be an alternative conditioning method for the treatment of porcelain surfaces.

A study on Cause Analyses of Fatal injuries by the Mobile Cranes (이동식 크레인 사고사망재해 심층분석 연구)

  • Shin, Woon-chul;Yeo, Hyun-Wook;Kwon, Jun-hyuck;Yi, Kwan-Hyung
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • In this study, the current regulations to be adequate in industrial site have to be renew in order to prevent the fatal injuries by mobile cranes. Fatal injury analyses were conducted with several accident cases by the mobile cranes. For each accident, the causes of the injuries were examined and proper safety measures were proposed. This study proposed a revision of the standard guideline as an accident prevention measures through in-depth analysis of fatal accidents. First, fatality rate per 10,000 persons by the mobiles cranes was 0.57 in 2011. Second, the in-depth analysis of the mobile crane accidents showed that the main factors of the accidents were the overturn of mobile crane, the fracture of connection part between mobile crane boom and rope, the breaking of rope and the misunderstanding over the signal between a mobile crane driver and workers around a mobile crane. Third, the order of high defection of connecting parts was bucket bolt, bracket and extension parts. Fourth, since there were several cases of overturn of mobile crane by itself in the in-depth analysis of the mobile crane, the over slop-proof device was proposed as the main alternative in this study. Fifth, the revision of standards of safety factor that shall be more than 10, of connecting parts of mobile crane was proposed.

THE EFFECTS OF CRYSTAL GROWTH ON SHEAR BOND STRENGTH OF ORTHODONTIC BRACKET ADHESIVES TO ENAMEL SURFACE (Crystal growth에 의한 법랑질 표면처리가 교정용 브라켓 접착제의 전단결합강도에 미치는 영향)

  • Lee, Young-Jun;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.839-852
    • /
    • 1997
  • It has been submitted that different ion solutions containing sulfate induce crystal growth and might substitute conventional acid etching for pretreatment of enamel in orthodontic bonding(${\AA}rtun$ et al., Am. J. Orthod. 85, 333, 1984). This investigation was designed to evaluate the relevance of crystal growth on the enamel surface as an alternative to conventional acid etching in direct bonding of orthodontic brackets. Annexing Li2SO4, MgSO4, K2SO4 respectively in the solution with $25\%$ polyacrylic md 0.3M sulfuric acids were employed to enhance the crystal growth. Human bicuspids were treated with various parameters as combinations of crystal growth and glass ionomer cement, crystal growth and orthodontic resin, acid etching and orthodontic resin for an investigative purpose. Crystal growth solution containing MgSO4 showed the highest shear bond strength(15.6MPa) within the groups of bonding brackets with glass ionomer cement(p<0.01). Bonding with glass ionomer cement on the surface of crystal growth demonstrated higher shear bond strength than with orthodontic resin(p<0.001). Bonding with glass ionomer cement on the surface treated with crystal growth solution containing MgSO4 or K2SO4 was not different shear bond strength statistically from bonding with orthodontic resin on the acid-etched surface. It suggests that bonding brackets with glass ionomer cement on the surface treated with crystal growth solution containing MgSO4 or K2SO4 is a potential alternative to bonding with resin on the acid etched sufrace.

  • PDF