• 제목/요약/키워드: Allowable limit

검색결과 324건 처리시간 0.028초

복합 건축물 연결 통로에서의 기류형성에 관한 수치적 해석 연구 (A NUMERICAL STUDY ON FLOW PATTERN IN CONNECTING PASSAGEWAY OF A COMPOSITE BUILDING)

  • 전병진;장병윤;최형권
    • 한국전산유체공학회지
    • /
    • 제15권3호
    • /
    • pp.81-86
    • /
    • 2010
  • In this paper, a three-dimensional numerical study on flow pattern in winter along connecting passageway of a composite building was conducted using a commercial CFD package. The incompressible Navier-Stokes equation coupled was solved by using SIMPLE algorithm in order to find steady solutions. It was shown that a upward flow is generated inside the building in winter due to buoyancy effect and that the air inside connecting passageway flows from the shorter building to the taller one regardless of the slope of the passageway. Further, it was found that the magnitude of air velocity inside connecting passageway increases as the uphill slope to the taller building increases and decreases as the downhill slope to the taller one increases, although the variation in the magnitude of fluid velocity is not substantial. Lastly, it was shown that the maximum air velocity inside connecting passageway is less than the allowable limit for all the cases considered in this study.

원전 증기발생기 관리프로그램 (Steam Generator Management Program)

  • 조남철;김무수;이광우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.610-616
    • /
    • 2003
  • Recently, the common concern of nuclear power industry in the development of technology mitigating and preventing the aging of steam generator tubes prevails, because the trends of steam generator flaws at Uljin unit #1,2 and KSNP(Korea Standard Nuclear Power Plant) impose a burden on the operation of nuclear power plant. While the regulatory agency is demanding the establishment of the advanced general performance maintenance system, the steam generator management program adapting advanced technology is being developed which may comply with EPRI PWR SG Guidelines based on NEI 97-06 ‘ General Guidelines including all the maintenance aspects consist of the tube integrity assessment criteria, repair limit, allowable leakage level, water chemistry will be composed in order to obtain the approval of regulatory agency and be applied to Nuclear power plant early 2005. This presentation is to introduce maintenance state including SG tube degradation and main contents of advanced SG management program being developed, and futhermore update present and future plan, and estimate the alternation after the completion.

  • PDF

볼 엔드밀을 이용한 금형가공에 있어서 이송 속도 최적화에 대한 연구 (A Study on Feed Rate Optimization in the Ball End-milling Process Regarding of Tool Path and Workpiece Shape)

  • 김성윤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.102-106
    • /
    • 1996
  • In the ball end-milling process of a 3-dimensional mold, it is important to select cutting conditions and tool path considering the geometrical shape of a workpiece to reduce machining time. In this study, experiments were performed to decide allowable feed rate not breaking stability of system for different geometrical shapes. It was found that downcut is more stable than upcutting in machining side wall and downward is preferable to upward in inclined part depending on the angle of the inclination and depth of cut.

  • PDF

절삭공정의 적응제어에 관한 연구 (A Study on the Adaptive Control in Machining Process)

  • 송지복;이만형;이시복
    • 한국정밀공학회지
    • /
    • 제2권3호
    • /
    • pp.77-83
    • /
    • 1985
  • Adaptive control technique for a milling process is developed and implemented in an NC milling machine retrofitted to enable the micro-computer control. The control algorithm has the objects to guarantee the optimal tool life which can give the predetemined allowable lower limit of surface roughness. The experimental results show 1) that the extended tool life equation has good reliability in normal tool wear conditions. 2) and that the proposed adaptive control technique, which determine the optimal cutting condition by basing on the tool life equation modified continually according to the tool wear measured in real time, performs well.

  • PDF

저비중 SMC 외장패널의 피로특성 평가 (An Evaluation of the Fatigue Properties for External Panel Using Low Density SMC)

  • 김은성
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.830-835
    • /
    • 2012
  • A research for application of LDSMC(Low Density Sheet Molding Compound) composite is in progress for lightening the weight. This paper has performed fatigue test and simulation of external panel for Korean commercial vehicle. Before the fatigue test, static test was carried out. From the test, the structural safety was investigated using Goodman diagram. After the static test performance, the fatigue test was conducted at a range of load frequency 5Hz, a stress ratio(R) of 0.05 and an endurance limit of $10^6$ to obtain the S-N curve. The S-N curve is applied to the fatigue analysis of the external panel assembly. The result of FEM analysis was in accord with the experimental result within 83% confidence. It showed that the process to set up the safety range of allowable error is required in process of the design and simulation verification.

습분분리재열기 배수관 진동저감방안 (Vibration Reduction Method for Discharge Line of Moisture Separator Reheater)

  • 이준신;손석만;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

여객선에서의 진동과 Atrium Stairway (Vibration and an Atrium Stairway in a Passenger Ship)

  • 박주현;오정한;엄재광;한성용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.81-84
    • /
    • 2005
  • A passenger ship has some differences compared with a general commercial ship from the viewpoint of the structural arrangement. It is difficult to reinforce wide panels and local structures of a passenger ship because of its interior design when they have vibration problems. Moreover, the allowable vibratory limit for a passenger ship is much lower than that of a commercial ship. In this study, it is introduced that the procedure of the vibration analysis and the structural improvement for prevention of vibration with consideration of interior design for the Atrium stairway, one of the local structure installed in public space.

  • PDF

반도체 초정밀장비의 진동허용규제치를 고려한 지지구조의 동특성 개선에 관한 연구 (A Study on the Structural Dynamic Modification of Sub-structure of Clean Room Considering Vibration Criteria)

  • 손성완;이홍기;백재호
    • 반도체디스플레이기술학회지
    • /
    • 제2권2호
    • /
    • pp.25-30
    • /
    • 2003
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. This high technology equipments require very strict environmental vibration criteria in proportion to the accuracy of the manufacturing. In this paper, the dynamic analysis and modal test were performed to evaluate the dynamic properties of the constructing clean room structure. Based on these results, a structural dynamic modification(SDM) were required to satisfiy the vibration allowable limit for pression machine. Therefore, in order to improve the dynamic stiffness of clean room structure, the VSD system which can control the force applied on structure, were adopted and its utility were proved from dynamic test results of the improved structure after a modification work.

  • PDF

고속열차 동력차의 센터피봇 상대 회전각 계측에 관한 연구 (A Study on the Measurement of Relative Rotation of Center Pivot in Power Car of KTX)

  • 서승일;정우진
    • 한국철도학회논문집
    • /
    • 제9권3호
    • /
    • pp.277-281
    • /
    • 2006
  • The center pivot in the power car of KTX carries the traction force of the motor bogie to the carbody. The damage to the center pivot due to failure of swivel joint causes a serious hazard of the train. To prevent the hazard, information on the relative motion between bogie and carbody is necessary. In this paper, a method to measure the relative rotation of the center pivot is proposed and an actual test to verify the method and safety is conducted. The test results show that the rotation of the center pivot is within the allowable limit and the damage due to the relative motion doesn't take place.

틸팅열차의 원곡선부 주행시 안전성 평가 (Safety evaluation of tilting train on circular curve)

  • 김상수;엄기영;배재형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1703-1712
    • /
    • 2010
  • The safety of tilting train running on curved track is, in general, evaluated with a derailment coefficient calculated by the ratio of wheel load and lateral force, Particularly on curve, the wheel load and lateral force on rail may cause trackbed to be deformed, depending on their intensity, and moreover, often result in critical accident such as derailment. This study hence was intended to identify the cause of wheel load and lateral force so as to suggest the allowable wheel load reduction rate, lateral force limit and derailment coefficient, thereby quantitatively evaluating the operational safety of tilting train. This study therefore was aimed to analyze the wheel load and lateral force occurred during tilting train's operation on circular curve in such a way of comparing with traditional trains, by axle and speed, in a bid to eventually evaluate the operational safety of tilting train.

  • PDF