흰쥐에 삽입된 인공성형삽입물의 생체내 물리, 조직학적 변화의 비교 (Comparison of Physical & Histological Change of Alloplastic Implants after Implantation in Rat)

  • 김성남;노복균;김의식;황재하;김광석;이삼용;조백현
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.219-224
    • /
    • 2006
  • Augmentation rhinoplasty is one of the most popular aesthetic procedure in Asians. Numerous alloplastic implants have been used until now, but no accurate comparative analysis about the implant materials has been reported yet. This study in animal model was designed to determine the safety and effectiveness of various implant materials in augmentation rhinoplasty. The $15{\times}15{\times}2mm$ sized square shaped plate of $Gore-Tex^{(R)}$, silicone rubber, and $15{\times}15{\times}1.5mm$ sized $Medpor^{(R)}$ were implanted under panniculus carnosus of the abdomen wall of rat. And tissue specimens including the implant and surrounding soft tissue were obtained by en bloc excision in 6 months after implantation. The implants were estimated in weight and volume, and also the specimens were examined grossly and microscopically. The results revealed that increase of average weight 26.9%, decrease of average volume 55.4% in $Gore-Tex^{(R)}$ implant, increase of each average weight and volume 62.6%, 8.7% in $Medpor^{(R)}$ implant and very slight increase of both average weight and volume 4.7%, 1.1% in silicone rubber implant. Grossly, the $Gore-Tex^{(R)}$ was deformed, $Medpor^{(R)}$ was strongly adherent to surrounding soft tissue and the silicone rubber was well encapsulated and easily peeled off. Microscopically, silicone rubber showed foreign body reaction slightly and there were no inflammatory responses in all alloplastic implants. In our study, silicone rubber showed very proper alloplastic features for augmentation rhinoplasty due to causing no inflammatory response, no physical change, and no deformity.

Delayed Orbital Hemorrhage around Alloplastic Implants after Blowout Fracture Reduction

  • Ryu, Yong Ah;Park, Jae Beom;Kyung, Hyun Woo;Song, Seung Han;Kang, Nak Heon
    • 대한두개안면성형외과학회지
    • /
    • 제16권1호
    • /
    • pp.35-38
    • /
    • 2015
  • Alloplastic implants have been used to repair orbital wall fractures in most cases. Orbital hemorrhage is a rare complication of these implants and has been reported rarely in Korea. The purpose of this article is to report a late complication case focusing on their etiology and management. A 20-year-old male patient underwent open reduction with Medpor (porous polyethylene) insertion for bilateral orbital floor fractures. The initial symptom occurred with proptosis in the right side as well as vertical dystopia, which had started 4 days earlier, 8 months after surgery. Any trauma history after the surgery was not present. We performed an exploration and removal of hematoma with Medpor titanium meshed alloplastic implant. A case of delayed orbital hematoma following alloplastic implant insertion was identified. It occurred within the pseudocapsule of the implant. One week after surgery, overall symptoms improved successfully, and no complications were reported during the 11-month follow-up period. Although rare, orbital hemorrhage is a potential complication of alloplastic orbital floor implants, which may present many years after surgery. As in the case presented, delayed hematoma should be included in the differential diagnosis of late proptosis or orbital dystopia.

Late Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction

  • Lee, Chi An;Kang, Seok Joo;Yun, Ji Young;Sun, Hook
    • 대한두개안면성형외과학회지
    • /
    • 제18권2호
    • /
    • pp.137-140
    • /
    • 2017
  • Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.

Silicone Implant 삽입 후에 발생한 안와내 거대 낭종 (Large Intraorbital Cyst after Silicone Implant Insertion: A Case Report)

  • 하상욱;이혜경;유원민;탁관철
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.659-662
    • /
    • 2006
  • Purpose: Alloplastic implants, such as methylmethacrylate, Teflon, silicone, Supramid are commonly used to cover the floor defect and to prevent reherniation of the displaced orbital tissue in orbital floor fracture. Silicone implant has been used for reconstruction of orbital wall defects because of pliability, advantage of carving and chemically inert nature. However, silicone implant also has complications including infection, extrusion, pain, dystopia and tissue reaction. Cyst formation around the silicone implant is a very rare complication. According to many reports, cysts around alloplastic implant in an orbital area are mostly hemorrhagic cysts consisted of blood breakdown product with fibrous capsule cell in histologic examination. Methods: The authors report atypical case and successful treatment of intraorbital hemorrhagic cyst around silicone implant of a 37-year-old male patient. Results: Preoperative symptoms of diplopia, exophthalmos, proptosis, vertical dystopia and ectropion of lower eyelid were resolved after surgical removal of implants with surrounding capsule. Conclusion: Clinical suspicion of plastic surgeon is important in diagnosis of intraorbital cyst of patients who have history of silicone implantation and computed tomography is the standard tool of diagnosis. During the operation, caution must be taken on delivering the whole capsule of intraorbital cyst along with silicone implant to prevent recurrence of the cyst.

Cranioplasty Using Three-Dimensional-Printed Polycaprolactone Implant and Free Latissimus Dorsi Musculocutaneous Flap in a Patient with Repeated Wound Problem following Titanium Cranioplasty

  • Hee Tae Koo;Jeongseok Oh;Chan Yeong Heo
    • Archives of Plastic Surgery
    • /
    • 제49권6호
    • /
    • pp.740-744
    • /
    • 2022
  • Titanium mesh is an alloplastic material widely used for the reconstruction of moderate-to-large skull defects. Repeated wound problems or infection following these reconstructions inevitably lead to the replacement of the cranioplasty material. Among the various alloplastic materials, polycaprolactone implants are usually used for the coverage of small defects such as burr holes. Herein, we present a case of a large cranial defect successfully reconstructed with three-dimensional-printed polycaprolactone implant and a free latissimus dorsi musculocutaneous flap. Until 1-year followup, the patient showed a favorable esthetic outcome with no complications or wound relapse.

Gingival Sulcus Incision으로 제거된 Silicon Implant 삽입 후 발생한 안와내 낭종 (Removal of Silicon-associated Intraorbital Cyst with Gingival Sulcus Incision)

  • 권용석;김명훈;허정;이장호;이근철;김석권
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.29-32
    • /
    • 2009
  • Purpose: Alloplastic implants, such as $Silastic^{(R)}$, $Supramid^{(R)}$, Porous polyethylene, $Teflon^{(R)}$ have been used to prevent reherniation of orbital tissue and are known to be inert for many years, though complications are infrequently reported many years after their insertion. Complications associated with implants are infrequent, but infection, orbital hemorrhage, implant extrusion, motility restriction, migration of implant causing dacryocystitis, cystic formation have been described. The latter was known as a rare late complication of blow-out fracture repair. Methods: We report the case of a discovery of a intraorbital hemorrhagic cyst which developed after silicon implant insertion. This patient developed diplopia, unilateral proptosis, exophthalmos, vertical dystopia, ectropion 10 years after repair of blow-out fracture. In this case, orbital CT scan revealed intraorbital cyst surrounding the orbital implant. At surgery, a fibrous capsule surrounded the silicon implant and was filled with mucin pools. Results: Proptosis, diplopia, exophthalmos, ectropion, vertical dystopia were resolved after surgical removal of the cyst and implant. Conclusion: This case illustrate that it is important for us to be aware of the complication of cyst formation around the silicon implants.

인체 치간부위 치조골 결손에 사용된 합성골의 효과에 관한 연구 (THE EFFECTS OF POROUS HYDROXYAPATITE AND NATURAL CORAL ON HUMAN PERIODONTAL DEFECTS)

  • 심정민;최광춘;손성회
    • Journal of Periodontal and Implant Science
    • /
    • 제23권2호
    • /
    • pp.345-351
    • /
    • 1993
  • Various alloplastic materials have been used on the periodontally diseased ossous defects. Hydroxyapatite, which is used the most common alloplastic material is a non-resorbable form of calcium phosphate and natural coral which is a biodegradable by carbonic anhydrase in osteoclast was introduced recently. The purpose of the present study was to evaluate the clinical effects of porous hydoxyapatite and natural coral on the human periodontal defects. Four males and three females who had adult periodontitis were selected for this study. The teeth that had similar bone loss radiographically and periodontal pocket deeper than 5mm were selected. Gingival recession, pocket depth, plaque index(Silness & Loe), sulcus bleeding index and tooth mobility (measured by Periotest$^{(r)}$) were examined before graft. Before insertion of alloplastic materials, the depth from CEJ to bone crest and from CEJ to base of the osseous defect was recorded. Porous particulate hydroxyapatite(Interpore 200$^{(r)}$, A group) was place on the defect and natural coral(Biocoral$^{(r)}$, B group) was placed on the defect of the opposing tooth. Six months post-surgically the same parameters were recorded by reentry procedures. A and B group showed 0.6mm of mean recession. Mean reduction of pocket depth were 5mm for A group and 4.9mm of B group. Reduced SBI and tooth mobility were recorded. Osseous defect fills of the original defects were 2.9mm for A and 3mm for B group. Percentage defect fills were 71% for A and 59% for B group. The difference of defect fill between pre- and post-insertion was statstically significant(p<0.05). But the difference between the two groups was not significant statistically(p<0.05). The clinical impression at 6 month re-entry and the numerical date indicate that natural coral as well as porous particulate hydoxyapatite has a definite potential as an alloplastic implant in the treatment of periodontal osseous defects.

  • PDF

3D Printed Titanium Implant for the Skull Reconstruction: A Preliminary Case Study

  • Choi, Jong-Woo;Ahn, Jae-Sung
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권2호
    • /
    • pp.99-102
    • /
    • 2014
  • The skull defect can be made after the trauma, oncologic problems or neurosurgery. The skull reconstruction has been the challenging issue in craniofacial fields for a long time. So far the skull reconstruction with autogenous bone would be the standard. Although the autogenous bone would be the ideal one for skull reconstruction, donor site morbidity would be the inevitable problem in many cases. Meanwhile various types of allogenic and alloplastic materials have been also used. However, skull reconstruction with many alloplastic material have produced no less complications including infection, exposure, and delayed wound healing. Because the 3D printing technique evolved so fast that 3D printed titanium implant were possible recently. The aim of this trial is to try to restore the original skull anatomy as possible using the 3D printed titanium implant, based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. And we fabricated Titanium implant to reconstruct three-dimensional orbital structure in advance, using the 3D printer. This prefabricated Titanium-implant was then inserted onto the defected skull and fixed. Three dimensional printing technique of titanium material based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

Influence of wound closure on volume stability with the application of different GBR materials: an in vitro cone-beam computed tomographic study

  • Naenni, Nadja;Berner, Tanja;Waller, Tobias;Huesler, Juerg;Hammerle, Christoph Hans Franz;Thoma, Daniel Stefan
    • Journal of Periodontal and Implant Science
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2019
  • Purpose: To assess the influence of using different combinations of guided bone regeneration (GBR) materials on volume changes after wound closure at peri-implant dehiscence defects. Methods: In 5 pig mandibles, standardized bone defects were created and implants were centrally placed. The defects were augmented using different combinations of GBR materials: xenogeneic granulate and collagen membrane (group 1, n=10), xenogeneic granulate and alloplastic membrane (group 2, n=10), alloplastic granulates and alloplastic membrane (group 3, n=10). The horizontal thickness was assessed using cone-beam computed tomography before and after suturing. Measurements were performed at the implant shoulder (HT0) and at 1 mm (HT1) and 2mm (HT2) below. The data were statistically analysed using the Wilcoxon signed-rank test to evaluate within-group differences. Bonferroni correction was applied when calculating statistical significance between the groups. Results: The mean horizontal thickness before suturing was $2.55{\pm}0.53mm$ (group 1), $1.94{\pm}0.56mm$ (group 2), and $2.49{\pm}0.73mm$ (group 3). Post-suturing, the values were $1.47{\pm}0.31mm$ (group 1), $1.77{\pm}0.27mm$ (group 2), and $2.00{\pm}0.48mm$ (group 3). All groups demonstrated a loss of horizontal dimension. Intragroup changes exhibited significant differences in group 1 (P<0.001) and group 3 (P<0.01). Intergroup comparisons revealed statistically significant differences of the relative changes between groups 1 and 2 (P=0.033) and groups 1 and 3 (P=0.015). Conclusions: Volume change after wound closure was minimized by using an alloplastic membrane. The stability of the augmented horizontal thickness was most ensured by using this type of membrane irrespective of the bone substitute material used for membrane support.

Lateral alveolar ridge augmentation procedure using subperiosteal tunneling technique: a pilot study

  • Kakar, Ashish;Kakar, Kanupriya;Sripathi Rao, Bappanadu H.;Lindner, Annette;Nagursky, Heiner;Jain, Gaurav;Patney, Aditya
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.3.1-3.8
    • /
    • 2018
  • Background: In this research article, we evaluate the use of sub-periosteal tunneling (tunnel technique) combined with alloplastic in situ hardening biphasic calcium phosphate (BCP, a compound of β-tricalcium phosphate and hydroxyapatite) bone graft for lateral augmentation of a deficient alveolar ridge. Methods: A total of 9 patients with deficient mandibular alveolar ridges were included in the present pilot study. Ten lateral ridge augmentation were carried out using the sub-periosteal tunneling technique, including a bilateral procedure in one patient. The increase in ridge width was assessed using CBCT evaluation of the ridge preoperatively and at 4 months postoperatively. Histological assessment of the quality of bone formation was also carried out with bone cores obtained at the implant placement re-entry in one patient. Results: The mean bucco-lingual ridge width increased in average from 4.17 ± 0.99 mm to 8.56 ± 1.93 mm after lateral bone augmentation with easy-graft CRYSTAL using the tunneling technique. The gain in ridge width was statistically highly significant (p = 0.0019). Histomorphometric assessment of two bone cores obtained at the time of implant placement from one patient revealed 27.6% new bone and an overall mineralized fraction of 72.3% in the grafted area 4 months after the bone grafting was carried out. Conclusions: Within the limits of this pilot study, it can be concluded that sub-periosteal tunneling technique using in situ hardening biphasic calcium phosphate is a valuable option for lateral ridge augmentation to allow implant placement in deficient alveolar ridges. Further prospective randomized clinical trials will be necessary to assess its performance in comparison to conventional ridge augmentation procedures.