• Title/Summary/Keyword: Allograft biopsy

Search Result 13, Processing Time 0.031 seconds

TECHNETIUM-99m BONE SCAN FOR EVALUATING AUTOLOGOUS ILIAC BONE GRAFT AND FREEZE-DRIED BONE ALLOGRAFT IN DOG'S MANDIBLE (Technetium-99m 골주사를 이용한 하악골의 자가골 및 동종골 이식의 평가에 대한 실험적 연구)

  • Jin, Sung-Bark;Kim, Soo-Kyung
    • The Journal of the Korean dental association
    • /
    • v.22 no.1 s.176
    • /
    • pp.37-48
    • /
    • 1984
  • Clinical assessment of bone-graft healing in the maxillofacial region is generally limited to clinical evaluation, radiographs, and biopsy. Sequential interpretation of osseous repair, more sensitive than with conventional radiography is possible with a non-invasive, non-destructive radionuclide method. Technetium-99m radionuclide bone scan was used in the evaluation of the progress of osteogenic activity in autologous iliac bone graft and freeze-dried bone allograft of dog's mandible. Bone scan was performed at 1wk, 2wk, 4wk, 6wk, and 8wk after grafting. In autologous graft the activity ratio for the graft bone remained greater than that of the host since 2자 after grafting; however, in lyophilized allograft the activity ratio for graft bone was greater than that of the host at 6자 after grafting.

  • PDF

A Study of Aortic Vasculopathy after Cardiac Allograft (동종 심장이식 후의 대동맥 혈관병증에 관한 연구)

  • Chung, Won-Sang;Chung, Yoon-Sang;Kim, Young-Hak;Kim, Hyuck;Kang, Jeong-Ho;Paik, Seung-Sam;Song, Dong-Seop;Jang, Hyo-Jun
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.135-140
    • /
    • 2009
  • Background: Chronic rejection after a cardiac allograft usually occurs about six months after the operation. Vasculopathy due to chronic rejection causes atherosclerosis in the coronary artery of the transplanted heart and then this causes myocardial injury. We intended to discover and document those findings that occur in a transplanted ascending aorta. Material and Method: In rats weighting $200{\sim}300gm$ (Spraque-Dawley rat), we carried out heterotopic heart allo-transplantation with the modified Ono-Lindsey method and then the rats were administrated cyclosporine (10mg/kg/day). After three months survival, we acquired biopsy materials from the native ascending aorta and the allo-transplanted ascending aorta and we compared them. We classified each severity of 1) intimal thickening, 2) medial hyperplasia, 3) medial calcification, 4) medial inflammation and 5) chondroid metaplasia, which are specific biopsy findings for chronic rejection after a cardiac allograft. Each severity was classified, according to the opinion of one pathologist, in the native ascending aorta biopsies (n=9) and the allo-transplanted ascending aorta biopsies (n=13). The data of the control group and the study group were statistically analyzed with using the Mann-Whitney test (SPSS version 12.0 window). Result: The important changes of the allo-transplanted aorta were intimal thickening (p<0.0001), medial calcification (p=0.045), medial inflammation (p<0.0001) and chondroid metaplasia (p=0.045), but not medial hyperplasia (p=0.36). Conclusion: Cardiac allograft vasculopathy was seen in the transplanted ascending aorta, the same as was seen in the coronary artery, after allograft cardiac transplantation. We have reached the conclusion that chronic rejection also progresses in the aorta.

Disseminated adenovirus infection in a 10-year-old renal allograft recipient

  • Lee, Bora;Park, Eujin;Ha, Jongwon;Ha, Il Soo;Cheong, Hae Il;Kang, Hee Gyung
    • Kidney Research and Clinical Practice
    • /
    • v.37 no.4
    • /
    • pp.414-417
    • /
    • 2018
  • Disseminated adenovirus infection can result in high mortality and morbidity in immunocompromised patients. Here, we report the case of a 10-year-old renal allograft recipient who presented with hematuria and dysuria. Adenovirus was isolated from his urine. His urinary symptoms decreased after intravenous hydration and reduction of immunosuppressants. However, 2 weeks later he presented with general weakness and laboratory tests indicated renal failure necessitating emergency hemodialysis. Adenovirus was detected in his sputum; therefore, intravenous ganciclovir and immunoglobulin therapy were initiated. Renal biopsy revealed diffuse necrotizing granulomatous tubulointerstitial nephritis compatible with renal involvement of the viral infection. Adenovirus was detected in his serum. Despite cidofovir administration for 2 weeks, adenovirus was also detected in the cerebrospinal fluid, resulting in generalized tonic-clonic seizure. The patient died 7 weeks after the onset of urinary symptoms. Adenovirus should be considered in screening tests for post-renal transplantation patients who present with hemorrhagic cystitis.

Preliminary evaluation of a three-dimensional, customized, and preformed titanium mesh in peri-implant alveolar bone regeneration

  • Jung, Gyu-Un;Jeon, Jae-Yun;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • Objectives: The purpose of this preliminary study is to evaluate the effectiveness of a customized, three-dimensional, preformed titanium mesh as a barrier membrane for peri-implant alveolar bone regeneration. Materials and Methods: Ten patients were recruited for this study. At the time of implant placement, all patients had fenestration or a dehiscence defect around the implant fixture. A mixture of particulate intraoral autologous bone and freeze-dried bone allograft was applied to the defect in a 1 : 1 volume ratio and covered by the preformed titanium mesh. A core biopsy specimen was taken from the regenerated bone four months postoperatively. Patients were followed for 12 months after the definitive prosthesis was placed. Results: Satisfactory bone regeneration with limited fibrous tissue was detected beneath the preformed titanium mesh. Histologic findings revealed that newly formed bones were well-incorporated into the allografts and connective tissue. New growth was composed of approximately 80% vital bone, 5% fibrous marrow tissue, and 15% remaining allograft. All implants were functional without any significant complications. Conclusion: The use of preformed titanium mesh may support bone regeneration by maintaining space for new bone growth through its macro-pores. This preliminary study presents the efficacy of a preformed titanium mesh as a ready-to-use barrier membrane around peri-implant alveolar bone defect. This preformed mesh is also convenient to apply and to remove.

Donor Specific Antibody Negative Antibody-Mediated Rejection after ABO Incompatible Liver Transplantation

  • Lee, Boram;Ahn, Soomin;Kim, Haeryoung;Han, Ho-Seong;Yoon, Yoo-Seok;Cho, Jai Young;Choi, Young Rok
    • Korean Journal of Transplantation
    • /
    • v.32 no.4
    • /
    • pp.108-112
    • /
    • 2018
  • Antibody-mediated rejection (AMR) is a major complication after ABO-incompatible liver transplantation. According to the 2016 Banff Working Group on Liver Allograft Criteria for the diagnosis of acute AMR, a positive serum donor specific antibody (DSA) is needed. On the other hand, the clinical significance of the histological findings of AMR in the absence of DSA is unclear. This paper describes a 57-year-old man (blood type, O+) who suffered from hepatitis B virus cirrhosis with hepatocellular carcinoma. Pre-operative DSA and cross-matching were negative. After transplantation, despite the improvement of the liver function, acute AMR was observed in the protocol biopsy on postoperative day 7; the cluster of differentiation 19+ (CD19+) count was 0% and anti-ABO antibody titers were 1:2. This paper presents the allograft injury like AMR in the absence of DSA after ABOi living donor liver transplantation with low titers of anti-ABO antibody and depleted serum CD19+ B cells.

Changes of Kidney Injury Molecule-1 Expression and Renal Allograft Function in Protocol and for Cause Renal Allograft Biopsy (이식신 계획생검 및 재생검에서 Kidney Injury Molecule-1 표현과 이식신 기능 변화)

  • Kim, Yonhee;Lee, A-Lan;Kim, Myoung Soo;Joo, Dong Jin;Kim, Beom Seok;Huh, Kyu Ha;Kim, Soon Il;Kim, Yu Seun;Jeong, Hyeon Joo
    • Korean Journal of Transplantation
    • /
    • v.28 no.3
    • /
    • pp.135-143
    • /
    • 2014
  • Background: Kidney injury molecule-1 (KIM-1) is known as a good ancillary marker of acute kidney injury (AKI) and its expression has also been observed in acute rejection and chronic graft dysfunction. We tested usefulness of KIM-1 as an indicator of acute and chronic renal graft injury by correlating KIM-1 expression with renal graft function and histology. Methods: A total of 133 zero-time biopsies and 42 follow-up biopsies obtained within 1 year posttransplantation were selected. Renal tubular KIM-1 staining was graded semiquantitatively from 0 to 3 and the extent of staining was expressed as the ratio of KIM-1 positive/CD10 positive proximal tubules using Image J program. Results: KIM-1 was positive in 39.8% of zero-time biopsies. KIM-1 positive cases were predominantly male and had received grafts from donors with older age, deceased donors, and poor renal function at the time of donation, compared with KIM-1 negative cases. KIM-1 expression showed correlation with delayed graft function and acute tubular necrosis. In comparison of KIM-1 expression between stable grafts (n=23) and grafts with dysfunction (n=19) at the time of repeated biopsy, the intensity/extent of KIM-1 staining and renal histology at zero-time did not differ significantly between the two groups. Histologically, KIM-1 expression was significantly increased with both acute and chronic changes of glomeruli, tubules and interstitium, peritubular capillaritis, and arteriolar hyalinosis. Conclusions: KIM-1 can be used as an ancillary marker of AKI and a nonspecific indicator of acute inflammation and tubulointerstitial fibrosis. However, KIM-1 expression at zero-time is not suitable for prediction of long-term graft dysfunction.

THE COMPARATIVE STUDY OF GUIDED BONE REGENERATION USING VARIOUS OF BONE GRAFT MATERIALS (다양한 골 이식재를 이용한 골유도재생술의 골 치유에 관한 비교 연구: 예비연구)

  • Kim, Young-Kyun;Kim, Su-Gwan;Lim, Seung-Cheoul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.350-358
    • /
    • 2007
  • The purpose of this study is to evaluate the superficial bony healing after guided bony regeneration using a various bone grafts. Four types of bone grafts were performed by one oral and maxillofacial surgeon to restore the defects around endosseous implants. Group I included the allografts using $Regenaform^{(R)}$. Group 2 included the autograft. Group 3 included the combined grafts using with autogenous symphysis bone and xenograft($BioOss^{(R)}$). Group 4 included the xenograft($BioOss^{(R)}$). After some heling period, superficial bone biopsy was performed with the surgical blade(#15) during the second surgery. Histologic and histomorphmetric examination were carried out by one pathologist. There was the most new bone formation in the group 3, next group 2. However, there were no statistically significant differences. All group except for group 4 showed favorable bone formation and remodeling.

A Case of Hemolysis after Minor ABO Mismatched Kidney Transplantation (ABO 부적합 신이식 후 발생한 용혈 1례)

  • Hahn HyeWon;Ha Il Soo;Cheong Hae Il;Choi Yong
    • Childhood Kidney Diseases
    • /
    • v.6 no.1
    • /
    • pp.120-122
    • /
    • 2002
  • A 9-year-old boy of B blood group with end-stage renal disease due to IgA nephropathy received group O kidney transplantation from his father On day 9, he developed intravascular hemolysis, and anti-B autoantibody formation was confirmed. We diagnosed as immune hemolytic anemia due to passenger lymphocyte from donor, and cyclosporine withdrawl was done. Anemia resolved spontaneously, but on day 18, graft dysfunction developed, and graft biopsy revealed acute allograft rejection. Although hemolysis due to autoantibody is very rare and often mild, and the role of hemoglobinuria on acute rejection in this case is not certain, we recommend consideration of aggressive management on severe hemolysis after minor mismatched kidney transplantation. (J Korean Soc Pediatr Nephrol 2002 ; 6 : 120-2)

  • PDF

An Assessment of Allograft Function in Canine Single Lung Transplantation (일측 폐이식 실험견에서 이식폐의 기능 평가연구)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.28 no.12
    • /
    • pp.1096-1106
    • /
    • 1995
  • We experienced 7 cases of left single lung transplantation in 14 mongrel dogs and analyzed graft lung function by hemodynamics, blood gas analysis, chest X-ray, biopsy and perfusion lung scan. We performed right pulmonary artery cuff[PA cuff for analysis of graft lung function in 3 cases. The donor lungs were flushed with modified Euro-Collins solution[n=3 or low potassium dextran glucose solution[n=4 and preserved for 4 to 5 hours[n=4 or 24 hours[n=3 at 10o C and implanted to the dogs with similar weight . Assessment of left graft lung was done by occluding the right pulmonary artery for 10 minutes using PA cuff. Assessment for graft lung function was done immediately after an operation and after 3 days, 7days and 3 weeks postoperatively. Four dogs survived for 3days, 7days[2 cases and 3 weeks respectively. Other three dogs expired within 3 hours of reperfusion. Immediate perfusion scans of left lung in four survived dogs after reperfusion were 42.1%, 36% , 11% and 5.9% respectively, and another dog with 4.8% perfusion to left lung was dead due to left atrial thrombi after 3 hours reperfusion. In one case among three acute rejections follow-up perfusion scan was done on 3rd and 11th postoperative day and the result decreased from 36% perfusion immediate postoperatively to 21% and 15% respectively. Three expired dogs postoperatively couldn`t tolerate occlusion of right pulmonary artery with above 40 mmHg of mean pulmonary artery pressure. On the other hand, three survival dogs postoperatively tolerated occlusion of right pulmonay artery with less than 30 mmHg of mean pulmonary artery pressure. and one dog couldn`t tolerate same procedure immediate postopertively but in 2 hours reperfusion later tolerated with 29 mmHg of mean pulmonary artery pressure.In conclusion we couldn`t compare the effect of two flushing solutions but low potassium dextran glucose solution showed relatively safe preservation effect in cases with preservation of more than 20 hours. Also canine left single lung transplantation model with PA cuff indicated useful method for the assessment of graft lung function with effect of lung preservation.

  • PDF

Investigation and Standardization on Current Practice of Renal Transplant Pathology in Korea

  • Cho, Uiju;Suh, Kwang Sun;Kie, Jeong Hae;Choi, Yeong Jin;Renal Pathology Study Group of Korean Society of Pathologists,
    • Korean Journal of Transplantation
    • /
    • v.31 no.4
    • /
    • pp.170-176
    • /
    • 2017
  • We need to establish an informative guideline to increase inter-institutional and inter-observer reproducibility of renal transplant diagnosis, and to improve the diagnostic ability of pathologists in Korea. A first nation-wide survey for renal transplant pathology was conducted by Renal Pathology Study Group of the Korean Society of Pathologists in 2016, to provide the continued excellence in the transplantation pathology laboratory, and to improve the diagnostic ability for the best treatment of transplant patients. This survey revealed the significant variations in scale, work load and biopsy indications for the renal transplant pathology in various institutions in Korea. The Banff classification were used by all institutions for the diagnosis of renal transplant pathology, but different formats were used: most institutions (70%) used the "2013 Banff classification" while the others were using "2007 Banff classification" (20%) or even older formats. In daily diagnostic practice of the renal allografts, difficulties that pathologists encounter were quite diverse due to different environments they work in. Most respondents agreed that standardized diagnostic practice guidelines, regular education on renal transplant pathology and convenient ways of consultation are further needed. We are currently working toward the enhancement of the expertise of renal pathologists and to increase inter-institutional and inter-observer reproducibility by 1) development of a set of virtual slides of renal allograft biopsies for the training, 2) validation and gathering expert's consensus on the core variables of rejection diagnosis by using virtual slides, and 3) continued education by the developed virtual slide atlas.